NetUP Streamer HD v2 8-24x User manual

1/7, Ulofa Palme str., Moscow, Russia
+7 (495)510-1025 |info@netup.tv |http://netup.tv
NetUP Streamer HD v2 8-24x
User manual
20 March 2019

NetUP Streamer HD v2 8-24x. User manual
2
Contents
Introduction ............................................................................ 3
Appearance and illustration................................................................................................... 3
Specifications ......................................................................................................................... 5
Installation guide..................................................................... 6
Device’s installation flow chart.............................................................................................. 6
Packing list check ................................................................................................................... 6
Safety instructions ................................................................................................................. 6
Environment requirement ..................................................................................................... 7
Grounding requirement ......................................................................................................... 7
WEB NMS Operation ............................................................... 8
Login ....................................................................................................................................... 8
Summary → Status................................................................................................................. 9
Parameters → Module 1-6..................................................................................................... 9
Parameters → TS Config ...................................................................................................... 10
Parameters → IP Stream...................................................................................................... 12
Parameters → OSD .............................................................................................................. 13
System → Network .............................................................................................................. 15
System → Password............................................................................................................. 15
System → Configuration ...................................................................................................... 16
System → Firmware............................................................................................................. 16
System → Date | Time ......................................................................................................... 17
System → Log....................................................................................................................... 17
Troubleshooting.........................................................................................18

NetUP Streamer HD v2 8-24x. User manual
3
Introduction
NetUP Streamer HD v2 8-24x is a professional HD audio & video encoding and multiplexing device. It
has 12 HDMI (8/16/20/24 HDMI optional) video input interfaces, supporting MPEG-4 video encoding
and MPEG 1 Layer 2 audio encoding. This device can simultaneously encode 12(8/16/20/24 HDMI
optional) channel HD audio & video; moreover, it has an IP output port can support 1MPTS and
12SPTS (8/16/20/24 SPTS) IP out. In conclusion, its high integration and design make the device
widely used in varieties of digital distribution systems such as cable TV digital head-end, satellite
digital TV broadcasting etc.
Appearance and illustration
Front panel:
1
Reset key
3
ASI output port (Optional)
4
Data port indicator
5
DATA Port (one GE port and one FE for IP stream output)
6
NMS/CAS

NetUP Streamer HD v2 8-24x. User manual
4
Rear panel:
1
Power switch, fuse, power socket and grounding pole
2
24 HDMI input

NetUP Streamer HD v2 8-24x. User manual
5
Specifications
Input 12 HDMI inputs (8/12/16/20/24 input optional)
Video
Encoding
MPEG-4 AVC/H.264
Resolution
input
1920×1080_60P, 1920×1080_60i,
1920×1080_50P, 1920×1080_50i,
1280×720_60P, 1280×720_50P,
720×576_50i,720×480_60i
output
1920×1080_30P, 1920×1080_25P,
1280×720_30P, 1280×720_25P,
720×576_25P,720×480_30P
Bitrate
1Mbps~13Mbps (each channel)
Rate control
CBR/VBR
GOP Structure
IP…P (P Frame adjustment, without B Frame)
Audio
Encoding
MPEG-1 Layer 2
Sample rate
48KHz
Resolution 24-bit
Bitrate
64kbps, 128Kbps, 192kbps, 224kbps, 256kbps,
320kbps, 384kbps
Multiplexing
Maximum PID Remapping
180 input per channel
Function
PID remapping (automatically or manually)
Accurate PCR adjusting
Generate PSI/ SI table automatically
Output
12×SPTS IP or 1MPTS output over UDP/RTP, 1×1000 Base-T Ethernet interface
ASI output (optional) as copy of MPTS
System Network management (WEB)
Ethernet software upgrade
Other
parameters
Dimension (W×L×H)
482mm×410mm×44mm
Approx. weight
8kg
Temperature
0~45℃ (work); -20~80℃ (storage)
Power requirements
AC 100V-220V±10%, 50/60Hz
Power consumption
70W

NetUP Streamer HD v2 8-24x. User manual
6
Installation guide
Device’s installation flow chart
Before installing and connecting the device, carefully read the environment and
grounding requirements, as well as safety instructions for the sake of your safety and for
the safety of the device
Packing list check
Check items according to packing list. Normally it should include the following items:
•NetUP Streamer HD v2 8-24x
•Power Cord
•HDMI cable
Safety instructions
•Before installing and connecting the device make sure that the device was not damaged during
delivery.
•Install the device in an appropriate place. The device is designed to work in a clean and dry room.
It must be operated and maintained free of dust.
•Before switching on the device make sure that it is adjusted to the mains voltage you intend to
use. Make sure that you keep within the specifications – AC 100V-220V±10%, 50/60Hz.
•Check that all the cables are connected properly. Connect cables only to a device that is turned
off.
Packing list
check
Connecting
grounding
wire and
power cord
Installing
device
Connecting
signal cable
Setting
parameter
Running
device

NetUP Streamer HD v2 8-24x. User manual
7
Environment requirement
Item
Requirement
Room space
When installing a rack in the room, make sure the distance between two
rows of racks is 1.2~1.5m and the distance to the wall must be at least 0.8m.
Room floor
Electric isolation. Dust free. The volume resistivity of ground anti-static
material: 1×107~1×1010 Ω. Grounding current limiting resistance: 1M (Floor
bearing should be greater than 450Kg/m2).
Environment
temperature
5~40℃ (sustainable), 0~45℃ (short time).
Installing air-conditioning is recommended.
Relative temperature
20%~80% (sustainable); 10%~90% (short time).
Pressure
86~105KPa
Door & window
Install rubber strip for sealing door-gaps and dual level glasses for windows
Walls
Can be covered with wallpaper or dark paint.
Fire protection
Fire alarm system and extinguisher.
Power
The device requires AC 100V-220V±10%, 50/60Hz.
Please carefully check before running.
Grounding requirement
•Connect the ground wire to the grounding hardware on the device. Ground resistance should be
no more than 1 Ω
Grounding is essential for device’s functionality, surge and electronic interference
protection
•Keep proper contact with the metal housing of the device
•Grounding wire must be made out of copper and as thick and short as possible
•Make sure the two ends of grounding wire conduct electricity and are not rusty
•It is prohibited to use any other devices as a part of grounding electric circuit
•All racks should be connected with a protective copper strip. Ground loops should be avoided
•Grounding wire’s contact area with the rack should be no less than 25mm2

NetUP Streamer HD v2 8-24x. User manual
8
WEB NMS Operation
Use the Web interface to control NetUP Streamer HD v2 8-24x.
Login
Connect a personal computer and the device with net cable, and use ping command to confirm they
are on the same network segment.
Make sure that the computer’s IP address is different from the device’s IP address;
otherwise, it would cause an IP conflict
The default IP address of NetUP Streamer HD v2 8-24x is 192.168.0.136. Thus, set the computer’s IP
address to 192.168.0.X, where X can be from 0 to 255, except 136. Open a web browser, enter the
device’s IP address in the browser address bar and press Enter. If the network is configured correctly,
you will see the login interface (Figure 1).
Enter username and password and click LOGIN to enter the web interface. Default username is
“admin”, default password is “admin”.
Figure-1

NetUP Streamer HD v2 8-24x. User manual
9
Summary →Status
After login, you will get the Status page which displays the current system status (Figure-2).
Figure-2
Parameters →Module 1-6
This encoder supports up from 2 to 6 modules with 8/12/16/20/24 HDMI input. Use the Module 1-6
page to set coding parameters for each channel (Figure-3).
Figure-3
System information
Use this menu to
navigate between the
interface pages
Set
parameters
Select a channel
Confirm changes

NetUP Streamer HD v2 8-24x. User manual
10
Parameters → TS Config
Use the TS Config page to configure the TS output parameters and select one of the following tabs:
Stream Select, General or PID Bypass.
Stream Select
Select the Stream Select tab to select streams that should be sent to Mux out and to modify program
info (Figure-4).
Figure-4
Configure input and output streams with following buttons:
add an input channel
delete an input channel
edit an input channel
delete all input channels
Lose / Locked input signal lock. Green means signal is present
Normal / Overflow
TS overflow status. Red means that TS is overflowing and
you need to decrease number of channels
CA Filter filter or not filter the source CA information
PID Remap enable or disable PID remapping
Refresh input / output refresh an input or an output
===> / <=== move programs between the input and the output areas
All input / output select all input or output programs
Parse program parse programs with a time limit
Input area
Output area

NetUP Streamer HD v2 8-24x. User manual
11
Click on a program in the output area to open the Program information window (Figure-5):
Figure-5
General
Select the General tab to edit common parameter for output streams (Figure-6).
Figure-6

NetUP Streamer HD v2 8-24x. User manual
12
PID Bypass
Select the PID Bypass tab to edit the list of PIDs that should pass through (Figure-7).
Figure-7
Parameters →IP Stream
NetUP Streamer HD v2 8-24x supports TS to output in IP format through the DATA1 and DATA2 port.
Use the IP Stream page to set IP out parameters (Figure-8).
Figure-8
Quick config
Channel config

NetUP Streamer HD v2 8-24x. User manual
13
Parameters →OSD
Use the OSD page to configure the OSD parameters and select one of the following tabs: Logo,
Caption or QRCode.
Logo
Figure-9
Select a tab
Select a module and a
program for applying a
logo or select “ALL” to
apply the logo to all
programs and all modules

NetUP Streamer HD v2 8-24x. User manual
14
Caption
Figure-10
QRCode
Figure-11
Write your
text here

NetUP Streamer HD v2 8-24x. User manual
15
System →Network
Use the Network page to edit networking parameters (Figure-12).
Figure-12
System →Password
Use the Password page to change current password and username (Figure-13).
Figure-13
Confirm changes
Confirm changes

NetUP Streamer HD v2 8-24x. User manual
16
System →Configuration
Use the Configuration page to save or restore the system configuration, to work with backups, to
return to the factory settings and to load the configuration file (Figure-14).
Figure-14
System →Firmware
Use the Firmware page to update firmware for the device (Figure-15).
Figure-15

NetUP Streamer HD v2 8-24x. User manual
17
System →Date | Time
Use the Date | Time page to set date and time for the device (Figure-16).
Figure-16
System →Log
Use the Log page to see system logs (Figure-17).
Figure-17

NetUP Streamer HD v2 8-24x. User manual
18
Troubleshooting
Check the following before troubleshooting:
•Whether the server room is well ventilated and hot air from the back panel of the device is
effectively removed?
•Does the supply voltage meet the power requirements of the device?
•Are all cables connected correctly?
Turn off the device and unplug the power cord in the following cases:
•The power cord or socket is damaged.
•A liquid is splashed on the device.
•A short circuit has occurred.
•The device is in damp environment.
•The device suffered from physical damage.
•Longtime idle.
•After switching on and restoring to factory setting, device still cannot work properly.
•Maintenance needed.
Frequent on and off switching is prohibited; the interval between switching the device on
and off must be more than 10 seconds
Table of contents
Other NetUP Media Converter manuals
Popular Media Converter manuals by other brands

Ltech
Ltech LT-916 Product introduction

Techly
Techly IDATA SCART-HDMI3 user manual

Speaka Professional
Speaka Professional SP-AV2HDMI operating instructions

Techly
Techly IDATA USB2-SER-1 Quick install guide

Weidmuller
Weidmuller WavePak DC/DC operating instructions

Versa Technology
Versa Technology VX-200M-X3 quick start guide

PS Audio
PS Audio PerfectWave DirectStream DAC MK2 Instructions for use

StarTech.com
StarTech.com USB32DVCAPRO instruction manual

KanexPro
KanexPro SP-4KPROSLIM1X4 instructions

LevelOne
LevelOne GVT-2010 user manual

LuxCom
LuxCom 100BASE-TX operating manual

Transition Networks
Transition Networks CBFTF1011-155 user guide