netvox R313CC User manual

Model:R313CC
Wireless 2-Gang Door/Window Sensor
Wireless 2-Gang Door/Window Sensor
R313CC
User Manual
Copyright©Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX
Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in
whole or in part, without written permission of NETVOX Technology. The specifications are subject
to change without prior notice.

1
Table of Content
1. Introduction.................................................................................................................2
2.Appearance..................................................................................................................3
3. Main Features .............................................................................................................3
4. Set up Instruction........................................................................................................4
5. Data Report.................................................................................................................5
6. Installation ..................................................................................................................9
7. Important Maintenance Instruction ..........................................................................10

2
1. Introduction
R313CC is connected with two external reed switches which can be used for door and window
switch state detection. The wireless alarm and other functions can be realized through the built-in
wireless module. The device is compatible with LoRaWAN protocol.
LoRa Wireless Technology:
LoRa is a wireless communication technology famous for its long-distance transmission and low
power consumption. Compared with other communication methods, LoRa spread spectrum
modulation technique greatly extend the communication distance. It can be widely used in any use
case that requires long-distance and low-data wireless communications. For example, automatic
meter reading, building automation equipment, wireless security systems, industrial monitoring. It
has features like small size, low power consumption, long transmission distance, strong
anti-interference ability and so on.
LoRaWAN:
LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure
interoperability between devices and gateways from different manufacturers.

3
2. Appearance
3. Main Features
• Compatible with LoRaWAN protocol
• 2 sections of 3V CR2450 button batteries
• Adopt SX1276 wireless communication module
• Frequency hopping spread spectrum
• Configuration parameters can be configured via a third-party software platform, data can be read
and alerts can be set via SMS text and email (optional)
• Applicable to third-party platforms: Actility/ThingPark, TTN, MyDevices/Cayenne
• Low power consumption and long battery life
Note:
Battery life is determined by the sensor reporting frequency and other variables, please refer to
http://www.netvox.com.tw/electric/electric_calc.html
On this website, users can find battery lifetime for varied models at different configurations.
Indicator
Function Key

4
4. Set up Instruction
On/Off
Power on Insert batteries. (users may need a screwdriver to open)
Insert two sections of 3V CR2450 button batteries and close the battery cover.
Turn on Press any function key and the green and red indicator flashes once.
Turn off
(Restore to factory setting)
Press and hold the function key for 5 seconds and the green indicator flashes
20 times.
Power off Remove Batteries.
Note:
1. Remove and insert the battery, the device memorizes previous on/off
state by default.
2. On/off interval is suggested to be about 10 seconds to avoid the interference
of capacitor inductance and other energy storage components.
3. Press any function key and insert batteries at the same time, it will enter
engineer testing mode.
Network Joining
Never joined the network
Turn on the device to search the network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Had joined the network
Turn on the device to search the previous network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Function Key
Press and hold for 5 seconds
Restore to factory setting / Turn off
The green indicator flashes 20 times: success
The green indicator remains off: fail
Press once The device is in the network: green indicator flashes once and sends a report
The device is not in the network: green indicator remains off

5
The device will immediately send a version packet and the report data with the status and voltage.
Data will be reported by default setting before any configuration.
Default setting:
Max Interval: 3600s
Min Interval: 3600s (Detect the reed state every Min Interval by default setting)
Battery Change :0x01 (0.1V)
R313CC status:
When the R313CC status changes, it will send a report.
Window / Door sensor open: 1
Window / Door sensor close: 0
The reported data is decoded by the Netvox LoRaWAN Application Command document and
http://loraresolver.netvoxcloud.com:8888/page/index
Sleeping Mode
The device is on and in the
network
Sleeping period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a data
report according to Min Interval.
Low Voltage Warning
Low Voltage 2.4V
5. Data Report
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Max Interval
(Unit:second) Reportable Change Current Change≥
Reportable Change Current Change<
Reportable Change
Any number
between 1~65535 Any number
between 1~65535 Can not be 0. Report
per Min Interval Report
per Max Interval

6
Example of ConfigureCmd
FPort:0x07
Bytes 1 1 Var (Fix =9 Bytes)
CmdID DeviceType NetvoxPayLoadData
CmdID– 1 byte
DeviceType– 1 byte – Device Type of Device
NetvoxPayLoadData– var bytes (Max=9bytes)
Description Device Cmd
ID
Device
Type NetvoxPayLoadData
Config
ReportReq
R313CC
0x01
0x6C
MinTime
(2bytes
Unit: s)
MaxTime
(2bytes
Unit: s)
Battery
Change
(1byte Unit: 0.1v)
Reserved
(4Bytes, Fixed
0x00)
Config
ReportRsp 0x81 Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
ReadConfig
ReportReq 0x02 Reserved
(9Bytes, Fixed 0x00)
ReadConfig
ReportRsp 0x82
MinTime
(2bytes
Unit: s)
MaxTime
(2bytes
Unit: s)
Battery
Change
(1byte Unit: 0.1v)
Reserved
(4Bytes, Fixed
0x00)
(1) Command Configuration:
MinTime = 1min、MaxTime = 1min、BatteryChange = 0.1v
Downlink:016C003C003C0100000000 003C(Hex) = 60(Dec)
Response:
816C000000000000000000 (Configuration success)
816C010000000000000000 (Configuration failure)
(2) Read Configuration:
Downlink:026C000000000000000000
Response:826C003C003C0100000000(Current configuration)

7
Example for MinTime/MaxTime logic
Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change
i.e.BatteryVoltageChange=0.1V
MaxTime MaxTime
Sleeping(MinTime) Sleeping(MinTime)
Note:
MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration
regardless BtteryVoltageChange value.
Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change
i.e. BatteryVoltageChange= 0.1V.
MaxTime
Sleeping(MinTime) sleeping sleeping sleeping
0H 15th M 30th M 45th M 1H
2H
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
REPORT 2.8V
Wake up and collects data
REPORTS 2.8V
Wakes up and collects data
REPORTS 2.8V
Wakes up and collects data
REPORTS 2.8V
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
REPORT 2.8V

8
Example#3 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change
i.e. BatteryVoltageChange= 0.1V.
MaxTime
sleeping sleeping
0H 15th M 30th M 45th M 1H 1H 10th M 1H 25th M
Notes:
(1) The device only wakes up and performs data sampling according to MinTime Interval.
When it is sleeping, it does not collect data.
(2) The data collected is compared with the last data reported. If the data change value is greater
than the ReportableChange value, the device reports according to MinTime interval.
If the data variation is not greater than the last data reported, the device reports according to
MaxTime interval.
(3) We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is
too low, the device wakes up frequently and the battery will be drained soon.
(4) Whenever the device sends a report, no matter resulting from data variation, button pushed
or MaxTime interval, another cycle of MinTime/MaxTime calculation is started.
Wakes up and collects
data
2.7V |2.7-2.8|=0.1
REPORTS 2.7V Wakes up and
collects data 2.7V
Does not report
Users push the button,
REPORTS 2.7V.
Recalculate MaxTime.
Wakes up and
collects data
2.8V
Does not report
Wakes up and
collects data
REPORT 2.8V
Wakes up and
collects data
2.7V
Does not report
Wakes up and
collects data
2.7V
Does not report
Wakes up and
collects data
2.7V
Does not report

9
6. Installation
1. Tear off the 3M sticker on the back of the
R313CC, and stick the body to a smooth wall.
(Please do not stick it on a rough wall to avoid
the device from falling off after a long time of
use).
Note:
Please wipe the wall clean before installation
to avoid dust on the wall which may affect
the installation of the device.
Do not install the device in a metal shielded
box or in an environment with other
electrical equipment around it to avoid
affecting the wireless transmission of the
device.
2. Tear off the 3M sticker at the bottom of the
reed switch and the magnet (as the red frame
in the figure above).
Then, stick the reed switch and the magnet to
the door or window in parallel (as the figure on
the right).
Note:
The installation distance between the reed
switch and the magnet should be less than
2cm.
3. When the door or window is opened, the reed switch is
separated from the magnet, and the device reports the data
immediately.
4. If it detects that the battery voltage exceeds the
variation during Min Time, the data will be reported
immediately.
5. Whether the state of the reed switch status changes, the
data will be reported regularly when the Max Time.
Note:
When the reed switch is closed, the status is “0”.
When the reed switch is opened, the status is “1”.
R313CC is suitable below scenarios:
Door, window
Drawer
Archives
Closet
Refrigerators and freezers
Cargo ship hatch
The place needs to detect the opening and closing status.
Installation Diagram of R313CC

10
7. Important Maintenance Instruction
Kindly pay attention to the following in order to achieve the best maintenance of the product:
•Keep the device dry. Rain, moisture, or any liquid might contain minerals and thus corrode
electronic circuits. If the device gets wet, please dry it completely.
•Do not use or store the device in dusty or dirty environment. It might damage its detachable
parts and electronic components.
•Do not store the device under excessive heat condition. High temperature can shorten the life
of electronic devices, destroy batteries, and deform or melt some plastic parts.
•Do not store the device in places that are too cold. Otherwise, when the temperature rises to
normal temperature, moisture will form inside, which will destroy the board.
•Do not throw, knock or shake the device. Rough handling of equipment can destroy internal
circuit boards and delicate structures.
•Do not clean the device with strong chemicals, detergents or strong detergents.
•Do not apply the device with paint. Smudges might block in the device and affect the operation.
•Do not throw the battery into the fire, or the battery will explode. Damaged batteries may also
explode.
All of the above applies to your device, battery and accessories. If any device is not working
properly, please take it to the nearest authorized service facility for repair.
Table of contents
Other netvox Security Sensor manuals

netvox
netvox RA08B Series User manual

netvox
netvox RA02A User manual

netvox
netvox R718WB2 User manual

netvox
netvox R313LA User manual

netvox
netvox ZB11D User manual

netvox
netvox S31501 User manual

netvox
netvox RA02C User manual

netvox
netvox R313FC User manual

netvox
netvox S31502 User manual

netvox
netvox R311A User manual

netvox
netvox R718WBA User manual

netvox
netvox RA08B Series User manual

netvox
netvox R311CB User manual

netvox
netvox R718WB User manual

netvox
netvox R718WA2 User manual

netvox
netvox Z801TXB User manual

netvox
netvox RA08D Series User manual

netvox
netvox R718PA7 User manual

netvox
netvox RA0708 User manual

netvox
netvox R718PA9 User manual