netvox R718WB User manual

Model:R718WB
Wireless Water Leak Detector with Rope Sensor
Wireless Water Leak Detector with
Rope Sensor
R718WB User Manual

1
Table of Content
1. Introduction.............................................................................................................................................................2
2. Appearance..............................................................................................................................................................2
3. Main Features..........................................................................................................................................................3
4. Set up Instruction ....................................................................................................................................................4
5. Data Report .............................................................................................................................................................5
6. Installation...............................................................................................................................................................8
7. Information about Battery Passivation .................................................................................................................10
8. Important Maintenance Instruction.......................................................................................................................11

2
1. Introduction
R718WB is a LoRaWAN device compatible with LoRaWAN protocol (ClassA). When the R718WB sensor detects a leak, it will
send an alarm message to the gateway. When the sensor detects no leaks, it will send a message that shows no leak to the
gateway.
LoRa Wireless Technology:
LoRa is a wireless communication technology dedicated to long distance and low power consumption. Compared with other
communication methods, LoRa spread spectrum modulation method greatly increases to expand the communication distance.
Widely used in long-distance, low-data wireless communications. For example, automatic meter reading, building automation
equipment, wireless security systems, industrial monitoring. Main features include small size, low power consumption,
transmission distance, anti-interference ability and so on.
LoRaWAN:
LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure interoperability between devices and
gateways from different manufacturers.
2. Appearance
Indicator
Function Key

3
3. Main Features
Apply SX1276 wireless communication module
2 ER14505 battery AA SIZE (3.6V / section) parallel power supply
Water leakage status detection
The base is attached with a magnet that can be attached to a ferromagnetic material object
IP Ratings: Main part – IP65/IP67 (Optional), Sensor-IP67
Compatible with LoRaWANTM Class A
Frequency hopping spread spectrum
Configuration parameters can be configured via a third-party software platform, data can be read and alerts can be set via
SMS text and email (optional)
Applicable to third-party platforms: Actility/ThingPark, TTN, MyDevices/Cayenne
Low power consumption and long battery life
Note:
Battery life is determined by the sensor reporting frequency and other variables, please refer to
http://www.netvox.com.tw/electric/electric_calc.html
On this website, users can find battery life of various models in different configurations

4
4. Set up Instruction
On/Off
Power on Insert batteries. (users may need a screwdriver to open)
Turn on Press and hold the function key for 3 seconds till the green indicator flashes once.
Turn off (Restore to factory setting) Press and hold the function key for 5 seconds till the green indicator flashes for 20
times.
Power off Remove Batteries.
Note:
1. Remove and insert the battery; the device is at off state by default.
2. On/off interval is suggested to be about 10 seconds to avoid the interference of
capacitor inductance and other energy storage components.
3. Five seconds after power on, the device will be in engineering test mode.
Network Joining
Never joined the network
Turn on the device to search the network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Had joined the network
(Not yet restore to factory setting)
Turn on the device to search the previous network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Fail to join the network
(when the device is on)
Suggest to check the device verification information on the gateway or consult your
platform server provider.
Function Key
Press and hold for 5 seconds
Restore to factory setting / Turn off
The green indicator flashes for 20 times: success
The green indicator remains off: fail
Press once The device is in the network: the green indicator flashes once and sends a report
The device is not in the network: the green indicator remains off
Sleeping Mode
The device is on and in the network
Sleeping period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a data report
according to Min Interval.
Low Voltage Warning
Low Voltage 3.2V

5
5. Data Report
When the device is turned on, it will immediately send a version package and a data report of water leakages/voltage.
Data will be reported once per hour by default setting.
(If there is special customized inquiry, the setting is changed according to customer requirements.)
Default report time:
Maximum time: 3600s
Minimum time: 3600s
Default reportchange:
Battery ---- 0x01 (0.1V)
R718WB sensor is triggered:
When the R718WB status changes, it will send warning report.
No water leak:0
Water leak:1
The reported data is decoded by the Netvox LoRaWAN Application Command document and
http://www.netvox.com.cn:8888/page/index
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Max Interval
(Unit:second) Reportable Change Current Change≥
Reportable Change
Current Change<
Reportable Change
Any number between
1~65535
Any number between
1~65535 Can not be 0. Report
per Min Interval
Report
per Max Interval

6
Example of ConfigureCmd
FPort:0x07
Bytes 1 1 Var(Fix =9 Bytes)
CmdID DeviceType NetvoxPayLoadData
CmdID– 1 bytes
DeviceType– 1 byte – Device Type of Device
NetvoxPayLoadData– var bytes (Max=9bytes)
Description Device Cmd
ID
Device
Type NetvoxPayLoadData
ConfigRepor
tReq
R718WB
0x01
0x12
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Reserved
(4Bytes,Fixed 0x00)
ConfigRepor
tRsp 0x81 Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
ReadConfig
ReportReq 0x02 Reserved
(9Bytes,Fixed 0x00)
ReadConfig
ReportRsp 0x82 MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Reserved
(4Bytes,Fixed 0x00)
(1) Configure device parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v
Downlink: 0112003C003C0100000000
The device returns:
8112000000000000000000 (configuration is successful)
8112010000000000000000 (configuration failed)
(2) Read device parameters
Downlink: 0212000000000000000000
The device returns:
8212003C003C0100000000 (device current parameter)

7
Example for MinTime/MaxTime logic:
Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
MaxTime MaxTime
Sleeping(MinTime) Sleeping(MinTime)
Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange
value.
Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
MaxTime
Sleeping(MinTime) sleeping sleeping sleeping
0H 15th M 30th M 45th M 1H 2H
Example#3 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
MaxTime
sleeping sleeping ...
0H 15th M 30th M 45th M 1H 1H 10th M 1H 25th M 1H 40th M 1H 55th M 2H 10th M
Notes :
1) The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not
collect data.
2) The data collected is compared with the last data reported. If the data variation is greater than the ReportableChange value,
the device reports according to MinTime interval. If the data variation is not greater than the last data reported, the device
reports according to MaxTime interval.
3) We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is too low, the device wakes up
frequently and the battery will be drained soon.
4) Whenever the device sends a report, no matter resulting from data variation, button pushed or MaxTime interval, another
cycle of MinTime/MaxTime calculation is started.
Wakes up and
collects data
3.6V
Does not report
Wakes up and
collects data
3.6V
Does not report
Wakes up and
collects data
3.6V
Does not report
Wakes up and
collects data
REPORTS 3.6V
Wakes up and
collects data
REPORT 3.6V
Wakes up and
collects data
REPORTS 3.6V
Wakes up and collects data
3.5V |3.5-3.6|=0.1
REPORTS 3.5V
Wakes up and
collects data
3.5V
Does not report
Wakes up and
collects data
3.5V
Does not report
Wakes up and
collects data
3.5V
Does not report
Wakes up and
collects data 3.5V
Does not report
Wakes up and
collects data
3.5V
Does not report
Wakes up and
collects data
REPORTS 3.5V
Wake up and collects data
REPORTS 3.6V
Wakes up and collects data
REPORTS 3.6V
Wakes up and collects data
REPORTS 3.6V
Wakes up and
collects data
3.6V
Does not report
Users push the button,
REPORTS 3.5V.
Recalculate MaxTime.

8
6. Installation
This product comes with waterproof function. When using it, the back of it can be adsorbed on the iron surface, or the two ends
can be fixed to the wall with screws.
Note: When installing the battery, use a screwdriver or similar tool to assist in opening the battery cover.
Waterline Structure:
Leakage Rope Length: Up to 300m*
Water contacting alarm:At least 3 cm line length
Alert: Instant report (within 10 seconds)
*The length of the water line has been configured before shipment. If user wants to increase or decrease the length manually, the
device must be returned to the factory for setting.
Installation Suggestions and Examples
fixed by cable clips fixed by vertical hoisting along pipe
(recommend) (recommend)(recommend)

9
binding with mental fixed by glue in front of air-conditioning outlet
(susceptible to interference)(susceptible to damage cable)(damp to false alarm )
R718WB
Time : Instant (Within 10 seconds)
cable clip
>3cm
Soaking water >3cm,Send a Report
Water
Soaking depth > 2mm
Water

10
7. Information about Battery Passivation
Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many advantages
including low self-discharge rate and high energy density.
However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium anode
and thionyl chloride if they are in storage for a long time or if the storage temperature is too high. This lithium chloride layer
prevents rapid self-discharge caused by continuous reaction between lithium and thionyl chloride, but battery passivation may
also lead to voltage delay when the batteries are put into operation, and our devices may not work correctly in this situation.
As a result, please make sure to source batteries from reliable vendors, and the batteries should be produced within the last three
months.
If encountering the situation of battery passivation, users can activate the battery to eliminate the battery hysteresis.
*To determine whether a battery requires activation
Connect a new ER14505 battery to a 68ohm resistor in parallel, and check the voltage of the circuit.
If the voltage is below 3.3V, it means the battery requires activation.
*How to activate the battery
1) Connect a battery to a 68ohm resistor in parallel
2) Keep the connection for 6~8 minutes
3) The voltage of the circuit should be ≧3.3V

11
8. Important Maintenance Instruction
Kindly pay attention to the following in order to achieve the best maintenance of the product:
• Keep the device dry. Rain, moisture, or any liquid, might contain minerals and thus corrode electronic circuits. If the device gets
wet, please dry it completely.
• Do not use or store the device in dusty or dirty environment. It might damage its detachable parts and electronic components.
• Do not store the device under excessive heat condition. High temperature can shorten the life of electronic devices, destroy
batteries, and deform or melt some plastic parts.
• Do not store the device in places that are too cold. Otherwise, when the temperature rises to normal temperature, moisture will
form inside, which will destroy the board.
• Do not throw, knock or shake the device. Rough handling of equipment can destroy internal circuit boards and delicate
structures.
• Do not clean the device with strong chemicals, detergents or strong detergents.
• Do not apply the device with paint. Smudges might block in the device and affect the operation.
• Do not throw the battery into the fire, or the battery will explode. Damaged batteries may also explode.
All of the above applies to your device, battery and accessories. If any device is not working properly, please take it to the nearest
authorized service facility for repair.
Other manuals for R718WB
1
Table of contents
Other netvox Security Sensor manuals

netvox
netvox RA02C User manual

netvox
netvox R718PA7 User manual

netvox
netvox R718WBA User manual

netvox
netvox ZB11D User manual

netvox
netvox R313WA User manual

netvox
netvox S31502 User manual

netvox
netvox R313W User manual

netvox
netvox RA08B Series User manual

netvox
netvox RA08B Series User manual

netvox
netvox R313WA User manual

netvox
netvox R313FA User manual

netvox
netvox R311CB User manual

netvox
netvox R718WB User manual

netvox
netvox R313CB User manual

netvox
netvox ZB11C User manual

netvox
netvox R718WB2 User manual

netvox
netvox R718B User manual

netvox
netvox Z801TXB User manual

netvox
netvox R313CC User manual

netvox
netvox R718WB2 User manual