NeuLog NUL-236 User manual

NEULOG RESPIRATION MONITOR BELT LOGGER SENSOR GUIDE
NeuLog respiration monitor belt logger sensor NUL-236
The NeuLog respiration sensor can be used for any science experiment which
involves respiration measurements such as in the fields of Exercise Science, Biology,
Physiology, Human Health, etc.
The sensor comes pre-calibrated so you can start experimentation right out of the box
using this guide.
Among hundreds of possible experimental subjects that can be studied with the NUL-
236 sensor are: exercise studies, human health studies, athlete comparisons,
respiration abnormalities, and many more.
The respiration sensor's measurement units are:
Arbitrary analog units (Arb): An arbitrary unit to demonstrate wave functions without
units.
Using the respiration monitor belt:
To accurately record respiration rates, you must first properly attach the respiration
monitor belt to the user. Note: The belt works through clothing though try to minimize
layers for the best readings possible.
1. Unwrap the respiration belt and locate the Velcro connection pads.
2. Place the respiration belt so the Velcro pads are facing outwards.
3. Wrap the respiration belt tightly, without causing discomfort, around the user’s
lower ribs and diaphragm area.
4. Ensure that the rubber tubing connected directly to the respiration belt is situated
above the user’s naval facing downwards.
5. Close the air pressure release valve by twisting the metallic knob until it tightens.
6. Use the hand-pump to fill the respiration belt’s bladder until it forms a snug but
not uncomfortable fit.
7. Run an experiment following one of the following guides.
Quick start procedure:
PC or Mac Computer
Materials needed:
NUL-236 Respiration Sensor
USB-200 USB Module
USB to mini USB cable (included with the USB-200 module)
Your respiration sensor needs to be connected to a USB-200 module. The USB-200
module then connects to a computer via a USB to mini-USB cable. Please note that
you cannot plug the respiration sensor directly into the computer.
The browser based application can be downloaded for free at www.NeuLog.com as
well as a full application user guide.
Choose "Downloads" on the main menu and then choose "Software and Application".
Procedure:
1. Install the NeuLog application.
2. Connect the USB-200 module to the PC or Mac.
3. Connect the respiration sensor to the USB-200 module (they directly plug
together). Please note that there is no calibration required for this sensor.
4. Open the NeuLog application by clicking on the shortcut on the screen.
5. Once a respiration sensor module box appears on the left side of the screen the
probe has been automatically identified and you can begin experimentation.
6. If the respiration sensor is not automatically identified then click the “Search for
sensors” icon to find the sensor.
7. Select the “On-line experiment” icon; this will open a graph below.
8. Click on the “Module setup” button located in the respiration sensor module box
to change the sensor's settings if need be.
9. Click on the "Experiment set up" icon to change the experiment settings if need
be (experiment duration for example).
10. The respiration sensor will give a live reading in its module box to the left of the
screen while plugged in.
11. To run an experiment and collect data click the “Run experiment” icon.
12. To end data collection early, click the “Stop experiment” icon.

NEULOG RESPIRATION MONITOR BELT LOGGER SENSOR GUIDE
Tablet, smart phone device
Materials needed:
NUL-236 Respiration Sensor
WIFI-201 WiFi Module
BAT-200 Battery Module
Your respiration sensor needs to be connected to a WIFI-201 module. The WIFI-201
module will create a closed NeuLog WiFi network which will stream the NeuLog data
to a device of your choosing. Once your device is wirelessly connected to the NeuLog
network, you can run experiments and collect data through a browser of your
choosing.
Procedure:
1. Connect the respiration sensor directly to the left side of a WIFI-201 (no wires
required).
2. Connect a BAT-200 module to the right side of the WIFI-201 module.
3. Although not required, we recommend plugging the BAT-200 to an outlet using a
USB to mini USB charger (such as a typical cell phone charger). The WIFI-201
module will run for 60-90 minutes (depending on the sensor) without being
plugged in.
4. The WIFI-201 module can be powered directly using a mini to USB cord and
plugging it into your computer or a wall charger. Please note this function is only
available on WIFI-201 modules with the USB icon on the cover.
5. For further WIFI-201 instructions or the WIFI-201 quick start guide please visit:
www.NeuLog.com; Choose "Products" on the main menu,
then choose "WiFi Communication module".
6. The WIFI-201 indicator lights will flash; take no action until the LED to the far left
turns blue; this can take up to one minute.
7. Take your tablet or smart phone, go to the WiFi settings and select the NeuLog
network (NeuLog0184 for example) which matches the ID found on the back of
the WIFI-201 module (0184 for example).
8. Give your device about 20 seconds to connect to the WIFI-201 module.
9. Once the device is connected, go to your browser and type the website
wifi201.com into the URL bar, then wait for 30-60 seconds.
10. You will see a “Control mode” icon in the application, click on it.
11. The application will then load a new screen and begin to auto detect the
sensor(s); this can take a minute. (You can stop the search when the sensor is
found.)
12. If the application does not auto detect the sensor(s), select “Search for sensors”.
13. Once the sensor is found you will see a module box on the left side of the screen
for the respiration sensor. In this box, real time data will be displayed.
14. Click on the “Module setup” button located in the respiration sensor module box
to change the respiration probe settings if need be.
15. Click on the “Experiment setup” icon to change the experiment settings if need
be (Experiment duration for example).
16. To run an experiment and collect data, click on the “On-Line experiment” icon,
then click the "Run experiment" icon.
17. If you have a newer generation WIFI-201 module (with the USB icon on the
cover) this can be used as a USB-200, meaning you can tether the probes
directly to the computer using the WIFI-201. To engage operation in this fashion,
press 3 times on the panel button. Repeating this operation will return the
module to WiFi mode.
Operation with NeuLog Graphic Display Module (viewer)
Materials needed:
NUL-236 Respiration Sensor
VIEW-101 Graphic Display Module
BAT-200 Battery module
Procedure:
1. Connect the respiration sensor to the left side of the viewer.
2. Connect the BAT-200 module to the right side of the viewer.
3. The VIEW-101 will auto detect the sensor and you will see it appear on the left
side of the screen.
4. Once the sensor appears it will be monitoring data in real time.
5. To run an experiment and collect data press the run icon (little green person).
Off-line experiments
(Off-line experiments are when you do not have a sensor connected directly to a
computer, tablet, smartphone, or NeuLog viewer).
Materials needed:
NUL-236 Respiration Sensor
BAT-200 Battery Module
Materials needed to configure your offline experiment:
USB-200 Module, WIFI-201 module or VIEW-101 Module
USB to mini USB cable (included with the USB-200 module).

NEULOG RESPIRATION MONITOR BELT LOGGER SENSOR GUIDE
Procedure:
1. To determine the experiment settings, first connect to your chosen device (PC,
Mac, tablet, smart device) and click on the “Off-line experiment” icon after the
sensor search has ended. (For more information on how to change the
experiment settings, view the quick start procedure section for your chosen
device in this document.)
2. Connect the respiration sensor directly to the left side of a charged BAT-200
module.
3. When ready to collect data press the “Start/Stop” button on the respiration
sensor, a red light will turn on for the duration of the experiment.
4. After the experiment has concluded (the “Start/Stop” button is pressed again or
the data collection period ends) connect the sensor to your chosen device (you
can find full instructions in each device’s quick start procedure section).
5. Open NeuLog application.
6. Click the “Off-line experiment” icon.
7. Click the “Load data from sensors” icon.
8. Select which experimental data to upload (5 experimental runs can be stored at
one time on the NUL-236 respiration sensor).
Restoring sensor’s factory default settings:
Procedure:
1. Connect the USB-200 to a PC, Mac, tablet, or smart device.
2. Connect the respiration sensor to a USB-200 module (they directly plug
together).
3. Open the NeuLog application.
4. Click the “Tools” icon.
5. Click “Restore sensor’s factory defaults” on the menu.
Included with the sensor:
NeuLog NUL-236 Respiration Sensor Guide (this document)
Respiration monitor belt attached directly to the sensor by flexible rubber tubing
Hand pump with pressure release valve attached directly to the respiration monitor
belt
Sensor's specifications
Range and operation
modes
0 to 20,000 arbitrary units
ADC resolution
15 bit
Resolution
1
Max sample rate (S/sec)
100
Experiment Duration: 1 second to 31 days.
Sensor's features:
Fully digital data
Rugged plastic ergonomic case
Respiration monitor belt attached to the sensor body by a flexible rubber hose
Hand pump with pressure valve for increasing and decreasing pressure attached
directly to the respiration monitor belt by a flexible rubber hose
Push button switch for Start/Stop experiments in off line mode
LED indicator of experiment status (blinks while collecting data)
Pre-calibrated sensing equipment
Note: NeuLog products are intended for educational use.
Videos and experiment examples:
Videos, literature and other probes can be found at www.NeuLog.com.
In order to access the respiration monitor belt sensor's page, choose "Products"
on the main menu and then "Respiration monitor belt logger sensor".
In order to find the science experiments, choose "Experiments" on the main
menu of the NeuLog website, then choose "Physics", "Chemistry", "Biology" or
"Environmental Science".
Biology Experiment:
oRespiration Rates (B-43)

NEULOG RESPIRATION MONITOR BELT LOGGER SENSOR GUIDE
Technical background:
The philosophy behind NeuLog’s plug and play technology is based on each sensor’s
ability to store its own data due to an internal flash memory chip and micro-controller
in each plastic NeuLog body. This technology allows the sensor to collect and then
store the digital data in the correct scientific units (oC, oF, Lux, %, ppm, for example).
The sensor is pre-calibrated at the factory. The built-in software in the logger can be
upgraded for free at any time using the provided firmware update.
The respiration sensor uses the piezoresistive effect. The transducer is based on
silicon between metal foils that changes its resistance according to pressure. One side
of it is at complete vacuum that enables to measure the absolute pressure on its other
side.
This transducer is built as a strain gauge with Wheatstone bridge circuit so its output is
a voltage that depends on its absolute pressure.
When the user inhales, a pressure is applied directly to the respiration monitor belt’s
air bladder and it is detected by the internal sensing unit and converted to a voltage.
The voltage reading is easily converted into arbitrary units and the pressure changes
to monitor respiration rate.
Maintenance and storage:
Never submerge the NeuLog plastic body in any liquid.
Do not allow liquid into the respiration sensor’s body.
After use, gently wipe away any foreign material from the respiration sensor.
Store in a box at room temperature out of direct sunlight.
Warranty:
We promise to deliver our sensor free of defects in materials and workmanship. The
warranty is for a period of 3 years from the date of purchase and does not cover
damage of the product caused by improper use, abuse, or incorrect storage. Sensors
with a shelf life such as ion selective probes have a warranty of 1 year. Should you
need to act upon the warranty, please contact your distributor. Your sensor will be
repaired or replaced.
Thank you for using NeuLog!
Flexible, simple, fast, forward thinking.
W: www.neulog.com
E: info@neulog.com
A: 850 St Paul Street, Suite 15, Rochester, NY 14605
P: 1.866.553.8536
V11042014
Table of contents
Other NeuLog Accessories manuals

NeuLog
NeuLog NUL-213 User manual

NeuLog
NeuLog NUL-213 User manual

NeuLog
NeuLog NUL-209 User manual

NeuLog
NeuLog NUL-235 User manual

NeuLog
NeuLog NUL-209 User manual

NeuLog
NeuLog NUL-246 User manual

NeuLog
NeuLog NUL-233 User manual

NeuLog
NeuLog NUL-214 User manual

NeuLog
NeuLog NUL-227 User manual

NeuLog
NeuLog NUL-230 User manual

NeuLog
NeuLog NUL-235 User manual

NeuLog
NeuLog NUL-206 User manual

NeuLog
NeuLog UL-202 User manual

NeuLog
NeuLog NUL-216 User manual

NeuLog
NeuLog NUL-223 User manual

NeuLog
NeuLog NUL-223 User manual

NeuLog
NeuLog NUL-228 User manual

NeuLog
NeuLog NUL-227 User manual

NeuLog
NeuLog NUL-214 User manual

NeuLog
NeuLog NUL-211 User manual