• enter the MENU mode (confirmed by the LED indicator)
8.5 - MENU mode & visual indications:
Dimmer-Control has a MENU with each position indicated by the specied LED indicator colour. In order to enter the menu press the B-button
and hold for at least 2 seconds. While the B-button is still pressed, LED indicator colour will change in the following sequence:
• BLUE - initiate the load calibration procedure
• RED - load calibration procedure with LED Adaptor
• WHITE - activate turning the load on/off using the B-button
• GREEN - reset the energy consumption data memory
• VIOLET - initiate the Z-Wave network range test
• YELLOW - reset the Dimmer-Control to factory defaults
Release the B-button to choose the desired function and conrm your choice with the B-button click.
9CALIBRATION
• Some types of LED and CF lamps are designed to operate in leading edge mode (with conventional dimmers). Information about proper
operation mode of the bulb should be included in its manual. In this case you have to manually force the desired operating mode using
parameter 30.
• During the calibration procedure, radio connection is disabled and Dimmer-Control does not respond to any commands. It may cause
temporary problems with communication in the Z-Wave network. After completing the calibration, communication with the module will be
restored.
Dimmer-Control is equipped with an algorithm of smart light source detection. Depending on the connected type of light source, it automati-
cally adjusts an optimal control mode (leading edge for inductive loads, trailing edge for capacitive or resistive loads). The procedure of learn-
ing the light source type is called calibration.
Calibration automatically adjusts maximum and minimum light levels (parameter 1 and 2). However, the installer is obliged to verify the proper
operation of the device, according to control modes description. There is a small probability that calibration settings will require a manual cor-
rection. In a 2-wire connection for loads other than resistive parameter 1 settings must be adjusted manually.
Calibration procedure is performed always after removing the device from the Z-Wave network. If the device is not included, after each power
on/off calibration will occur. For the included device, calibration is performed in accordance with the parameter 35 settings.
Calibration may be forced:
• by setting parameter 13 to 1 or 2 (without/with LED Adaptor)
• through triple clicking and holding the main light switch (each hold for more than 5 seconds)
• by selecting the appropriate MENU option using the B-button (see “Operating the device” on page 12).
By default, calibration is performed without LED Adaptor. In case of connecting the LED Adaptor, it is required to force the appropriate calibra-
tion procedure using B-button menu or through parameter 13. The device saves the last calibration enforcement mode (with or without LED
Adaptor).
The result of calibration will be conrmed with the LED indicator glowing in one of the following colours:
GREEN - Light source recognized as dimmable, dimming levels set, brightness may be controlled using the S1 switch.
YELLOW - Light source recognized as non-dimmable, possibility to turn ON/OFF connected light with default parameters settings.
RED - Calibration procedure failed. Possible reasons: lack of connected load or connected light source exceeds maximum power, which may
be controlled by Dimmer-Control.
BLINKING RED - Calibration procedure failed. Possible reasons: installation failure or damaged load (causing activation of the overcurrent
protection).
10 POWER AND ENERGY CONSUMPTION
Dimmer-Control allows for the active power and energy consumption monitoring. Data is sent to the main Z-Wave controller, e.g. Home Cen-
ter. Measuring is carried out by the most advanced micro-controller technology, assuring maximum accuracy and precision.
Electric active power - power that energy receiver is changing into a work or a heat. The unit of active power is Watt [W].
Electric energy - energy consumed by a device through a time period. Consumers of electricity in households are billed by suppliers on the
basis of active power used in given unit of time. Most commonly measured in kilowatt-hour [kWh]. One kilowatt-hour is equal to one kilowatt
of power consumed over period of one hour,
1kWh = 1000Wh.
Caution. Dimmer-Control in the 3-wire connection has the power and energy measurement function. In case of the 2-wire connection this
function is available only for load of cosφ ≥ 0.99. In other cases power is estimated and can differ from actual power consumed by the device.
Caution. Dimmer-Control stores periodically (every 5 minutes) the consumption data in the device memory. Disconnecting the module from
the power supply will not erase the energy consumption data.
Resetting consumption memory:
Dimmer-Control allows to erase stored consumption data in three ways:
a) By resetting the device.
b) Using functionality of a Z-Wave controller (see the controller’s manual).
c) Manually clearing the data using the following procedure: