manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. NICOR
  6. •
  7. Lighting Equipment
  8. •
  9. NICOR EMB250 -10-UNV User manual

NICOR EMB250 -10-UNV User manual

NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com June 14, 2018 10:25 AM rev 1.0
EMB250 -10-UNV
INSTALLATION INSTRUCTIONS
Carefully unpack EMB250 from packaging. Inspect prodcut for
defects due to shipping.
1
Turn o power to appropriate circuit at the breaker box.
2
Turn on power to appropriate circuit at the breaker box.
(Time to full charge: 48 hours)
5Check the functionality of the emergency system by
pressing the test button.
6
The NICOR EMB250-10-UNV should be mounted on or
nearby the xture above the ceiling. The ex conduit
marked ‘A’ should be wired into the driven lamp
compartment or to an electrical junction box on the
xture which allows access to the xture connections.
Under no circumstances should the battery pack exceed
a distance of 50’ from the lamp.
3
Connect wiring as shown.
4
IMPORTANT SAFEGUARDS, READ AND FOLLOW ALL SAFETY INSTRUCTIONS
WARNING/AVERTISSEMENT:
1. CAUTION- To prevent electrical shock, do not mate unit connector until installation is complete and AC power is supplied to
the unit.
2. CAUTION-This xture provides more than one power supply output source. To reduce the risk of electrical shock,
disconnect both normal and emergency sources by turning o the AC branch circuit and by disconnecting the unit connector.
3. CAUTION-This is a sealed unit. Components are not replaceable. Replace the entire unit when necessary.
4. CAUTION-Installation and servicing should be performed by qualied personnel only De-energize before opening.
5. DO NOT USE OUTDOORS. The EMB250-10-UNV is for use with grounded, UL Listed, damp location rated, indoor xtures.
Not for use in heated air outlets or hazardous locations.
6. The EMB250-10-UNV requires an unswitched AC power source of 120-277 volts. Properly cap the unused AC lead.
7. The EMB250-10-UNV and xture must be on the same branch circuit.
8. Do not mount near gas or electric heaters.
9. The EMB250-10-UNV should be mounted in locations and at heights where it will not readily be subjected to tampering by
unauthorized personnel.
10. The EMB250-10-UNV will supply 56VDC output at the individual rated specication for 90 minutes.
11. Suitable for use in damp locations.
12. For use in 0°C minimum, 50°C maximum ambient temperatures.
13. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
14. Do not use this equipment for other than intended use.
15. Install in accordance with the National Electrical Code and local regulations.
16. Lighting xture manufacturers, Electricians and end-users need to ensure product system compatibility before nal
installation.
17. CAUTION: Battery is rechargeable LiFePO4 type and must be recycled or disposed of properly.
18. The xture driver should be enclosed and the EMB250 case should be connected to ground.
19. CAUTION: Risk of electric shock, output voltage more than 42.4Vdc.
SAVE THESE INSTRUCTIONS
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com June 14, 2018 10:25 AM rev 1.0
EXPRESS LIMITED WARRANTY
Subject to the exclusions contained below, NICOR Inc. (NICOR) warrants that all NICOR LED branded Solid State Lighting products made by NICOR to be free from defects in materials and workmanship, under normal consumer usage
for a period of 3 years from date of purchase. This limited warranty is a consumer’s exclusive remedy, and applies only to new products purchased and used by consumers in the United States or Canada, which are accompanied by
this written warranty.
This limited warranty extends only to the rst consumer purchaser, and is not transferable. A consumer wishing to invoke the terms of this warranty must rst obtain a RGA number within 30 days of discovery of the defect, and
return the product to NICOR for inspection. Once veried to be covered by this limited warranty, NICOR will, at its discretion, repair, replace or refund the purchase price of any product that does not conform to this limited warranty.
This limited warranty covers only defects in material and workmanship associated with normal installation and intended use of the product.
THIS LIMITED WARRANTY DOES NOT COVER THE FOLLOWING:
• Defects or damages resulting from improper operation, storage, misuse or abuse, accident or neglect;
• Defects or damages resulting from improper service, testing, adjustment, installation, maintenance, alteration, connection to out-of-specication electrical service, corrosive or damp environments, or connection to incompatible
equipment or devices (e.g., connecting non-dimmable lighting products to dimmers);
• Damage which occurs in transit; and
• Labor or other charges or expenses associated with the removal, repair, or re-installation of defective or replacement products.
ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED TO THE DURATION OF THIS LIMITED WARRANTY,
OTHERWISE THE REPAIR, REPLACEMENT OR REFUND AS PROVIDED UNDER THIS EXPRESS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER, AND IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED. IN NO EVENT SHALL NICOR BE LIABLE, WHETHER IN CONTRACT OR IN TORT (INCLUDING NEGLIGENCE) FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, OR FOR ANY INDIRECT, INCIDENTAL, SPECIAL OR
CONSEQUENTIAL DAMAGES OF ANY KIND, OR LOSS OF REVENUE OR PROFITS, LOSS OF BUSINESS OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE ABILITY OR INABLILITY TO USE THE PRODUCT TO THE FULL
EXTENT THESE DAMAGES MAY BE DISCLAIMED BY LAW.
Copyright 2016, NICOR, Inc.
Revised November, 2016
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interfer-
ence that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
While pressing the test button adjust the
output current until the light dims down
(when the light dims down, emergency
driver is in protected mode and its
output current is 100mA). Then back o
No. 1 by 100mA.
Example: If No. 1 is set to 3 and No. 2 is
set to 5 for max light output. Turn No. 1
to 2 and achieve proper settings.
7Attach the appropriate labels
adjacent to the test switch and
charge indicator. Annotate
replacement label for LED array
type and wattage. The caution
and the relamping labels must be
on the xture in a readily visible
location to anyone attempting to
service the xture.
8
Operation
Normal Mode: Line Voltage power is present to the xture and the xture is operating as intended. The EMB250-10-UNV is in the standby charging mode. The Charge
Indicator will be lit providing a visual indication
Emergency Mode: The Line Voltage power fails. The EMB250-10-UNV senses the power failure and automatically switches to Emergency Mode. The xture will be
illuminated at a reduced intensity for a minimum of 90 minutes. When the AC power is restored, the EMB250-10-UNV switches the system back to the Normal Mode and
resumes battery charging. that the battery is being charged.
output current = NO.1 X 100mA + NO.2 X 10mA
e.g.: for the above diagram
output current = 10 X 100 + 5 X 10 + 1050mA
123 4
5
6
7
8
9
10
5
0
No. 1 No. 2
23
EMB250 -10-UNV
INSTALLATION INSTRUCTIONS
WE WOULD LIKE TO HEAR FROM YOU
Scan QR Code or Visit
nicorlighting.com/support/survey
WRITE A REVIEW
Thank You
For Your Purchase!
SAVE THESE INSTRUCTIONS
WE WOULD LIKE TO HEAR FROM YOU
Scan QR Code or Visit
nicorlighting.com/support/survey
WRITE A REVIEW
Thank You
For Your Purchase!
Set output with dial switch

Other NICOR Lighting Equipment manuals

NICOR ECL5 Series User manual

NICOR

NICOR ECL5 Series User manual

NICOR LED EMB4001UNV Series User manual

NICOR

NICOR LED EMB4001UNV Series User manual

NICOR DCR56 Series User manual

NICOR

NICOR DCR56 Series User manual

NICOR ECL21UNVWHR2 User manual

NICOR

NICOR ECL21UNVWHR2 User manual

NICOR EXL6 User manual

NICOR

NICOR EXL6 User manual

NICOR NLCSPCW1WH User manual

NICOR

NICOR NLCSPCW1WH User manual

NICOR EML6 User manual

NICOR

NICOR EML6 User manual

NICOR LED ECL3 User manual

NICOR

NICOR LED ECL3 User manual

NICOR EML7 User manual

NICOR

NICOR EML7 User manual

NICOR VT2 LED VAPORTITE User manual

NICOR

NICOR VT2 LED VAPORTITE User manual

NICOR EXL2 Series User manual

NICOR

NICOR EXL2 Series User manual

NICOR TPE Series User manual

NICOR

NICOR TPE Series User manual

Popular Lighting Equipment manuals by other brands

Global Pool Products SPLASH owner's guide

Global Pool Products

Global Pool Products SPLASH owner's guide

Ledvance FK-B-LED-4/10W Operating instructions manual

Ledvance

Ledvance FK-B-LED-4/10W Operating instructions manual

LIVARNO home 1118-R manual

LIVARNO home

LIVARNO home 1118-R manual

Genaray Powerhouse user manual

Genaray

Genaray Powerhouse user manual

Eaton Sirios O-SLED Instruction and operation manual

Eaton

Eaton Sirios O-SLED Instruction and operation manual

DE MAJO MEMORY R1 Assembly instructions

DE MAJO

DE MAJO MEMORY R1 Assembly instructions

Unex Nex Flex LED operating manual

Unex

Unex Nex Flex LED operating manual

Viking BLK-1A Technical practice

Viking

Viking BLK-1A Technical practice

Indal LIBRA Series installation instructions

Indal

Indal LIBRA Series installation instructions

Century DISCOVERY DSCD-15011040 quick start guide

Century

Century DISCOVERY DSCD-15011040 quick start guide

EuroLite LED TMH-B90 user manual

EuroLite

EuroLite LED TMH-B90 user manual

Draper WL6B Instructions for use

Draper

Draper WL6B Instructions for use

LEGRAND 0 580 10 instructions

LEGRAND

LEGRAND 0 580 10 instructions

Stoane Lighting inter-lux Niche Installation and maintenance instructions

Stoane Lighting

Stoane Lighting inter-lux Niche Installation and maintenance instructions

Piscines Magiline FX30 installation manual

Piscines Magiline

Piscines Magiline FX30 installation manual

Lightolier Lytecel 6 LIA6GPNXR132 specification

Lightolier

Lightolier Lytecel 6 LIA6GPNXR132 specification

EuroLite 51914234 user manual

EuroLite

EuroLite 51914234 user manual

Laserworld PL-5000G user manual

Laserworld

Laserworld PL-5000G user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.