VHC200
08/2018 9C385
GB
At the end of a cleaning session
■Stop the vacuum cleaner using tap (1- Fig. 4) and
disconnect the hose from the pneumatic system.
■Empty the container as described in the “Emptying the
container” paragraph.
■Clean the vacuum cleaner as described in the paragraph
“Maintenance, cleaning and decontamination”.
■Wash the container with clean water if aggressive
substances have been vacuumed.
■Store the vacuum cleaner in a dry place, out of reach of
unauthorized persons.
Maintenance, cleaning and
decontamination
WARNING!
To guarantee the safety level of the vacuum cleaner,
only original spare parts supplied by the manufacturer
should be used.
WARNING!
The precautions described below must be taken
during all maintenance operations, including cleaning
and replacing the primary and absolute lters.
WARNING!
The maintenance, cleaning and decontamination
operations must only be performed with the vacuum
cleaner turned o and disconnected from the
pneumatic system.
■If the user is performing the maintenance operations,
the vacuum cleaner must be disassembled, cleaned
and overhauled as far as reasonably possible without
hazards for the maintenance personnel or other people.
The precautions to take include decontamination before
disassembling the vacuum cleaner, ltered ventilation
of the exhaust air from the room in which the vacuum
cleaner is disassembled, cleaning the maintenance area
and suitable protection for personnel.
■A check must be carried out by the manufacturer or the
personnel of the same at least once a year. For example:
check the lters to make sure there are no air leaks
from the vacuum cleaner and the pneumatic system is
operating correctly.
Primary and absolute lter disassembly
and replacement
WARNING!
When the vacuum cleaner is used to vacuum
hazardous substances, the lters become
contaminated, therefore:
■work with care and avoid spilling the vacuumed
dust and/or material;
■place the disassembled and/or replaced lter in a
sealed plastic bag;
■close the bag hermetically;
■dispose of the lter in accordance with the laws
in force.
WARNING!
Filter replacement is a serious matter. The lter must
be replaced with one of identical characteristics,
ltering surface and category.
Otherwise the vacuum cleaner will not operate
correctly.
Primary lter replacement
Figure 7
Before proceeding with these operations, turn the vacuum
cleaner o and disconnect it from the pneumatic system.
■Release the stop (1), unscrew the lter shaker knob (2).
■Release the closing band (3).
■Lift cap (4).
■ Lift lter (5) and unscrew the lter clamp (6) on bearing
ring (7).
■Unscrew cage (8) and overturn the lter, exposing
coupling clamp (9).
■ Release the clamps and detach the cage from the lter.
■ Dispose of the lter according to the laws in force.
■ Fit the new lter and secure it in the cage with special
clamps. Assemble the components in the reverse order
of disassembly.
WARNING!
Take care not to raise dust when this operation is
carried out. Wear a P3 mask and other protective
clothing plus protective gloves (DPI) suited to the
hazardous nature of the dust collected, refer to the
laws in force.
If necessary contact the manufacturer’s Service Centre.