NINGLU Simulator SIM992
3
REPLY LEVEL
The REPLY LEVEL switch varies the replay level from 0.01mV to 50mV. The
AMPL VERNIER must be rotated to the maximum counter clockwise position
(CAL 1X position) for accuracy as indicated.
AMPL VERNIER
The AMPL VERNIER multiplies the setting value of the REPLY LEVEL switch.
If the REPLY LEVEL is set to 2mV and the AMPL VERNIER is set to 1.5, the
actual reply level is 3mV. Actual reply level = AMPL VERNIER × REPLY LEVEL
BOTTOM KEY
Press the BOTTOM key down and the bottom mode will appear, as indicated
by “BT” on the LCD screen. When the SIM992 is in the bottom mode, the
bottom echo frequency, echo width and echo depth can be set by depressing
the BOTTOM key repeatedly. Then the cursor can be moved left or right by
depressing ←/→key in current cursor range and the values can be increased
or reduced by depressing +/-key repeatedly.
Echo frequency range: 0~599.9 kHz, Echo width: 0~3999 x 10 us,
Echo depth: 0~999.99 m
FISH KEY
Press the FISH key down and the fish mode will appear, as indicated by “FI”
on the LCD screen. When the SIM992 is in the fish mode, the fish echo
frequency, echo width and echo depth can be set by depressing the FISH key
repeatedly. Then the cursor can be moved left or right by depressing ←/→
key in current cursor range and the values can be increased or reduced by
depressing +/-key repeatedly.
Fish echo frequency: 00:00~99:99
(E.g. 40:08 means that 8 times fish reply pulse will appear in 40 times transmitting steps)
Fish echo width: 0~3999 x 10 us (less than the value set in BT mode)
Fish echo depth: 0~999.99m (less than the value set in BT mode)
+/-KEY
Increase or reduce the values at current cursor.