Nitto Kohki delvo DLT1173A User manual

TV06576-2
TORQUE CHECKER OPERATION MANUAL
ANZIEHMOMENTPRÜFER GEBRAUCHSANLEITUNG
VÉRIFICATEUR DE COUPLE MODE D’EMPLOI
CONTROLLATORE DI COPPIA MANUALE DI FUNZIONAMENTO
MOMENTMÄTARE BRUKSANVISNING
TORQUÍMETRO MANUALDE FUNCIONAMIENTO
扭矩测量仪 操作手册
Models DLT1173A, DLT1673A, DLT1973A
Manufactured by:
NITTO KOHKI CO., LTD.
2-9-4, Nakaikegami, Ohta-ku, Tokyo
146-8555, Japan
Tel:(03) 3755-1111
Fax:(03) 3753-8791
Original instructions
GB
D
F
I
S
E
C


1
Thank you very much for purchasing a Delvo Torque Checker. For safe and efficient operation, please
read this Operation Manual through before use, get a good understanding of the operating precautions,
capabilities of this product, how to use it, and other details, and use it correctly.
Contents
1.Safety precautions .......................................................................................................................2
2.Overview .....................................................................................................................................3
3.Designations and dimensions of the components........................................................................4
4.Specifications ..............................................................................................................................5
4-1. Product proper........................................................................................................................5
4-2. Battery charger.......................................................................................................................5
5.Accessories..................................................................................................................................6
6.How to use the product................................................................................................................7
6-1. Getting ready for measurement..............................................................................................7
6-2. How to take measurements....................................................................................................8
6-3. Handling the measuring joints...............................................................................................8
6-4. Memory function .................................................................................................................10
6-5. External output.....................................................................................................................11
6-6. How to output data...............................................................................................................12
6-7. Changing data output speed.................................................................................................12
6-8. Judgment function and peak down setting...........................................................................13
6--9.Maximum, minimum, and average values calculation function..........................................14
6-10. Recharging ......................................................................................................................14
6-11.Resetting of the system........................................................................................................15
7.Examining and calibrating the Torque Checker........................................................................15
Meanings of the "symbols and signal terms"
The meanings of the "symbols and signal terms" indicated at the top of each precaution. Note that even an
item described in ! Caution may lead to a serious result depending on the case. Be sure to observe all
precautions, because every one of them describes something important.
Warning: Aprecaution about the possibility that mishandling may result in the death or serious injury of
the user.
Caution: Aprecaution about the possibility that mishandling may result in personal injury or property
damage.
Note: An important note about the installation, operation, and/or maintenance of the product.
!
!
GB

2
1.Safety precautions
•Be sure to take all "Safety precautions" given here to prevent fires, electric shocks, injury, and other
accidents.
•Read these "Safety precautions" carefully before use and use the product correctly according to the
instructions.
•After reading it, be sure to store this manual at a place where anyone using the product can have access to
the product any time.
- Warnings -
1. Keep the workshop neat and clean at all times.
•A disorderly workshop or work bench may lead to an accident.
2. Consider the surroundings of the workshop as well.
•Do not use the Torque Checker in rain or at a wet or moist place.
•Use it at a place with a constant temperature (about 20C) whenever possible.
•Keep the workshop bright enough.
•Do not use or recharge the product where a combustible liquid or gas is present.
3. Do not let any child come near the product.
•Do not let any person other than the responsible workers come near the workshop.
4. When not in use, store the product neatly.
•Store the product at a dry place and at a height inaccessible to children or in a lockable place. When
transporting it, use the packaging case that originally contained the product.
5. Wear neat clothes when doing work.
•Do not wear loose clothes or a necklace or other ornament.Any such object may get caught in the
rotary part.
6. Do not handle the cord roughly.
•Do not move the product while holding its cord when it is attached to the product. Do not pull the
cord to unplug it.
•Do not let the cord come near heat, oil, or a sharp edge.
7. Fasten the product firmly.
•Before measuring anything that may entail a high torque, fasten the product firmly. That way, you
can handle the product more safely than holding it with a hand. You can also hold the electric tool
with both hands.
8. Do not work in a straining posture.
•Keep your feet firm at all times. Keep the balance.
9. Service the Torque Checker carefully.
•For safe and efficient operation, check the measuring joint regularly. Use one whose thread and other
parts are free from deformation and wear.
•When replacing the accessories, follow the Operation Manual.
•Check the cord and extension cord regularly. If either of them is damaged, replace it.
10. Switch off the product and unplug it from the power source in any of the following cases:
•when the product is expected to remain unused or uncharged for some time
•when it is to be repaired
•in any other case when danger is expected.
11. Remain alert and take enough care when doing work.
•Use the product prudently, watching out for the proper method of handling, method of work,
surroundings, and other circumstances.
•Use common sense.
•Do not use the product when you are tired.

3
12. Check for damaged parts.
•Before use, check sufficiently for damage. Make sure that the product functions normally and
displays specified functionality.
•Check all parts that may affect the product's operation for any abnormality.
•When replacing any part, follow the Operation Manual.
13. Use specified accessories and joints.
•Do not use any part other than the accessories and joints described in this Operation Manual.
14. When you need any repair, commission it to an agency specializing in it.
•Do not remodel the product on your own.
•When you need any repair, be sure to commission it to the shop where you bought the product. If
anyone having no knowledge or expertise about the repair procedures tries to repair the product, the
product will not display its performance fully. Not only that, it may result in an accident or injury.
15. Do not apply a torque exceeding the specified permissible load to the product.
•Applying a torque exceeding the specified permissible load may damage the detector, resulting in an
accident or injury.
•Do not use the product on impact loads.
16. Do not disassemble or apply a strong impact or vibration to the product.
•This product is a precision device. Therefore do not disassemble it. If an excessive impact or
vibration damages the Torque Checker, it not only will fail to display its performance fully but also
may cause an accident or injury.
17. Recharge the product correctly.
•Recharge the product to the specified voltage. Do not use a DC power supply or engine generator.
Any such practice may cause the product to heat up abnormally, resulting in a fire.
•Do the recharging at a well-ventilated place. Do not cover the product with a cloth or anything
similar during the recharge.
18. Protect against electric shocks.
•Do not touch the power plug with a wet hand. That may cause an electric shock.
19. Do not throw the battery (contained in the product) into a fire.
•It may burst or emit a hazardous substance.
2.Overview
This Torque Checker aims to control screwdrivers on a routine basis (by means such as checking the changes in
torque with time).
It stores up to 800 items of data and has many user-friendly functions, including automatic power-off and
automatic clearing of torque display.

4
3.Designations and dimensions of the components
DLT1173A、DLT1673A
DLT1973A
Charge check lamp
Memory display/Data output key
Average calculation key
Judgment setting key
Charge check lamp
Memory display/Data output key
Average calculation key
Judgment
setting key

5
4.Specifications
4-1. Product proper
Model
DLT1173A
DLT1673A
DLT1973A
Measurement range N•m
0.015 - 1.500
0.15 - 10.00
4.00 - 12.00
Maximum allowable torque
N•m
1.800
12.00
18.00
Precision
Within 0.5% (F.S.)
For 0.2N•m or less,
1 digit
Within 0.5% (F.S.)
For 2N•m or less,
1 digit
Within 0.5% (F.S.)
Display
4-digit digital display (single-line) Data sampling: 1,000 times/sec
Display rate: 12 times/sec
Measuring direction
CW and CCW
Measuring mode
3 modes: PD-TR-PP
Measuring unit
N•m /kgf•cm/lbf•in (3 different units can be switched.)
Display reset
In PP and PD: Manual/auto switchover possible
TR: Manual only
Display reset time
Only effective in PP and PD auto: 0.1, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 sec
When PP and PD manual, the display retains its value reading until manually
operated.
Auto power-off
Powered off if left untouched for 10 minutes
Memory
800 data items
External output
As per USB output (single-direction, no procedure)
Mitsutoyo Digimatic (sequential output)
Analog output
Approx. 1.5V max.
Approx. 1.0V max.
Approx. 1.1V max.
No zero offset; identical waveforms produced in PP, PD, and TR modes
Sensor system
Bending system
Spring shape
75×14×1.4(t)
75×14×2.8(t)
75×14×3.8(t)
Measuring jig
Spring cushion system
Method of measurement
Measurements taken with the bit installed
Using NK bit NK35BN
13191075 (TD20457)
Environmental conditions
Storage temperature range
-10 - +40°C
Operating temperature range
+5 - +35°C
Humidity range
+10 - +90% (non-condensing)
Operating Environment
less than 2000m above sea level
Pollution Degree
degree 3 according to IEC60664-1
Over Voltage Category
category I according to IEC60664-1
Rechargeable battery
Nickel metal hydride battery
Rechargeable battery
capacity
1100mAh
Recharge time
4 hours
Continuous use time
20 hours
Outside dimensions
160 (W) ×110 (D) ×47 (H)
200 (W)×112 (D)×48 (H)
Weight
1.1kg
1.4kg
4-2. Battery charger
Article designation
DLE1833A
Rated input voltage
100 - 240VAC , 50/60Hz
Rated output voltage
12 V DC
No-load current
0.1 mA or less
Rated current
500 mA
Rated capacity
6 VA
Weight
75 g

6
5.Accessories
(1) Standard accessories
Model
DLT1173A
DLT1673A
DLT1973A
Measuring joint
Model: DLW4430
with spring for
0.15-1.5N•m (spring
color: golden)
Model: DLW4360
with spring (strong) for
0.15-6.5N•m (spring color:
black)
Model: DLW4000
Soft joint
Accessory spring
Model: DLW4660
Spring (weak) alone for
0.15-1.5N•m (spring color:
golden )
Accessory bit
NK Bit NK35BN
13×19×10×75
(TD20457)
Battery charger
Model: DLE1833A, Input: 100-240V AC, Output: 12VDC, 500mA
Plug for power
supply
A type plug x 1
Fix the measuring
joint
Two M3x6 knurled head screws
Casing
With black polyester casing
(2) List of options
Article
Model
Specification
Applicable models
DLT1173A
DLT1673A
DLT1973A
Holding fixture
DLW1300
Bracket to fix the body
–
Cable for analog signal
output
DLW9080
Cable for analog waveform output
Battery charger
DLE1833A
Overseas use: 100-240VAC, 50/60Hz
Plug for power supply
TV06573
Plug for Japan (Atype)
Plug for power supply
TV06574
Plug for Europe (C type)
Duralumin case
DLW4900
Special-purpose duralumin case
–
Soft joint
DLW4000
torque range: 4.0 to 12.0N•m
–
Bolt for hard joint
DLW4040
torque range: 4.0 to 12.0N•m
–
–
Measuring joint
DLW4330
4mm-diameter type, torque range: 0.015 to 0.25N•m
–
–
Measuring joint
DLW4340
4mm-diameter type, torque range: 0.15 to 1.5N•m
–
Measuring joint
DLW4350
Hex 5 and hex 6.35 types, torque range: 0.15 to 1.5N•m
–
Measuring joint
DLW4360
Hex 5 and hex 6.35 types, torque range: 0.15 to 6.5N•m
–
–
Measuring joint (for screw
type)
DLW4430
No.2 screw type, torque range: 0.15 to 1.5N•m
–
Measuring joint (for screw
type)
DLW4530
No.2 screw type, torque range: 0.15 to 5.0N•m
–
–
Bolt for soft joint
DLW4020
Size of screw for (DLW4000): M8X35-10.9
–
–
Bolt for hard joint
DLW4030
Size of screw for (DLW4040): M8X25-10.9
–
–
Shaft for measuring joint
DLW4610
For 4mm-diameter type (DLW4330), screw size M4
–
–
Shaft for measuring joint
DLW4620
For 4mm-diameter type (DLW4340), screw size M6
–
Shaft for measuring joint
DLW4630
For hex5 and hex6.35 types (DLW4350),screw size M6
–
Shaft for measuring joint
DLW4640
For hex5 and hex6.35 types (DLW4360),screw size M8
–
–
Disc spring for joint
DLW4010
For the torque range of 4.0 to 12.0N•m
–
–
Spring for measuring joint
DLW4650
For the torque range of 0.015 to 0.25N•m, spring color:
golden
–
–
Spring for measuring joint
DLW4660
For the torque range of 0.15 to 1.5N•m, spring color:
golden
–
Spring for measuring joint
DLW4670
For the torque range of 0.15 to 6.5N•m, spring color:
black
-
-
: Comes with the product as standard equipment : Available option –: Unsupported

7
6.How to use the product
6-1. Getting ready for measurement
(1) Stabilize the product.
DLT1173A、DLT1673A
Fasten the product if necessary. To fasten it securely, remove the rubber legs attached to the back side
and use the tap holes.
A holding fixture “DLW1300” is available as a separately sold item.
DLT1973A
Fix the body to a working bench with bolts, or securely fix the flange part of the base plate of the body
with a C-clamp, etc.
(2) Checking the battery level
The remaining battery level is indicated at the top of the display board. If the battery is insufficient,
charge it by inserting the connector of the supplied battery charger “DLE1833A” to the “DC IN”
terminal.
* When the battery charger is connected, there are cases where the battery level becomes FULL.
However, you should keep charging the battery while the lamp next to the “DC IN” terminal is lit.
Caution
As a battery charger, always use a DLE1833A.
Meaning of display on liquid crystal panel
Display on liquid crystal panel
Description
The battery is sufficient. No need to charge the battery.
The battery is low. You should charge the battery before long.
If you use the lamps and buzzers, for instance when performing
judgment, you should charge the battery ahead of time.
The battery is running out. Charge the battery immediately.
When the battery runs out, the power is immediately turned off.
(3) Setting the measurement mode
When you press the measuring mode switch key “MODE” for approx. 1 sec, the measuring mode
displayed on the liquid crystal panel is changed.
Every time you press the key, measuring mode is switched in turn.
There are the following three modes. You can use an appropriate one according to the use purpose.
[1] PP (peak measurement): Usually used to measure the torques of electric screwdrivers.
(Retained at 10 digits or higher.)
[2] TR (track measurement): Used to measure torque changes and to perform zero adjustment.
[3] PD (Peak down measurement): Used to measure the manual direct reading torque wrench, etc.
(Works at 10 digits or higher.)
(4) Zero adjustment
When the power is turned on and when the measuring mode is switched, zero adjustment is
automatically performed.
Although equipped with an automatic zero adjuster, the product may, although very rarely, fail to
display a "0" at power-up. In such a case, follow the steps described below to perform zero
adjustment.
To perform zero adjustment, set the “TR” mode, which measures the track, using the “MODE” key
to switch the measuring mode, and press the “CLEAR” key as no load is applied to the socket unit.
(5) Setting and change of measuring unit
When you press the “UNIT” key for approx. 1 sec, the measuring unit displayed on the liquid
crystal panel is switched.
(6) Setting the automatic reset function
You can set measurement display resetting in manual or auto (time setting). Setting it in auto mode
allows you to save labor in taking continued measurements.
[1] Set the power ON/OFF key to the OFF position.

8
[2] While holding down the CLEAR key, press the power ON/OFF key once. When the liquid
crystal panel displays something, stop pressing the CLEAR key.
[3] Each push of the CLEAR key changes the time reading. (The time reading will change as
shown below.) Select an automatic reset time. If, at that time, you cannot finish the setting
within 3 seconds, repeat the procedure with step 1).
[4] Now the automatic reset setting is over. But you have to reset the 0.0C reading manually.
Selections of the automatic reset times (in seconds)
0.0C0.1C0.5C1.0C
3.0C2.5C2.0C1.5C
6-2. How to take measurements
(1) Set the “PP” mode, which measures the peak, to “MODE”, which is the measuring mode switch key,
and press the “CLEAR” key as no load is applied to the socket unit.
(2) Plug the measuring joint to the socket of the product. Insert the screwdriver into the measuring
joint.
Each joint has a specific measurable torque range. Therefore check the torque range in which you
wish to take measurements and the torque range in which the joints can be measured.
Note Since there is an M3 screw hole at the socket side, fix the measuring joint into
the socket with the attached knurled head screw if necessary.
(3) Reverse the screwdriver to be measured and loosen the spring of the measuring joint.
(4) Press the “CLEAR” key and check that 0 is displayed.
Note If 0 is not displayed, perform zero adjustment.
(5) Turn the screwdriver to be measured in forward direction. Turn it until the screwdriver stops
automatically.
(6) Check that the screwdriver has stopped normally. Take the torque reading on the display. The
measurement is then over.
(7) Reverse the screwdriver again. Then loosen the measuring joint to a specified height.
(8) Repeat the steps (4) through (7) described above to check the output torque.
If pressing the CLEAR button does not reset the torque reading, or if the button will not function, or
if the product malfunctions otherwise, press the RESET button.
Push the RESET button by inserting the tip of a pen or something else with a thin tip into the hole.
Note that pressing that button will clear all data in the memory.
Note Any measurement taken with the Torque Checker may differ from the actual
screw-tightening torque.
6-3. Handling the measuring joints
(1) Replacing the spring
The DLT1673A comes with two kinds of springs: one for 0.15-1.5N•m (weak) and another for
0.15-6.5N•m (strong). The joints are equipped in advance with springs for 0.15-6.5N•m. Therefore
replace the joint with one for 0.15-1.5N•m when measuring low torques.

9
(2) How to use a soft joint or a hard joint (DLT1973A)
Soft joint DLW4000 (included as standard)
According to ISO5393, a screw is defined to turn more than 720in its seated position before it gets the
specified torque when it tightens a soft item (soft joint). Use the proper combination for the tightening
condition.
Attention: Note that some drivers may not be able to measure with a soft joint.
Combination of disc spring (DLW4010) for soft joint (separately sold)
The combination of disc springs (<><><><>) should be as the diagram below indicates. Do not change
the number (8) and the combination (direction) of disc springs in using a soft joint.
(3) Checking the measuring joints
Be sure to grease up the threaded portion of each measuring joint. Check the inside thrust bearing
regularly for damage.
Note In the measurement of ungreased threads, it may be that correct measurement is not possible,
for such reasons as accelerated thread wear. Before storage, be sure to loosen the threads.
Note It is recommended to replace the measuring joints at intervals of 2,500 operations or 1 year
as a guide.
Hard joint DLW4040 (separately sold)
According to ISO5393, a screw is defined to turn 30in its seated position before it gets the specified
torque when it tightens a hard item (hard joint)

10
Combination of bearing ring and bearing
The combination of a bearing ring and a thrust needle bearing should be the diagram below indicates,
and apply grease to the bearing ring and the bearing.
Using a different combination (direction) from the diagram below may cause the damage to the parts.
6-4. Memory function
Before storing data, you must set the automatic resetting to manual in advance as per [6-1]-(6)).
Note Note that data cannot be stored in the TR mode.
(1) How to store data
This product can store measurement data in its memory. Take measurements by following the
procedure described in 6-2.
[1] To save the displayed torque, press the “UP” key, and the data is saved in the memory from the
memory number “001”.
If any data has been already saved in the memory, the data is saved in the next memory number.
Note Up to 800 data can be saved. When data exceeds 800, data is overwritten from the
memory number 001.
(2) How to delete memory data individually
[1] Press the “MEM/OUTPUT” key and “MEM” is displayed at the bottom of the liquid crystal
panel, and the last saved data number and measurement value are displayed in turn.
[2] Press the “UP” key or “DOWN” key, the memory number is changed, and you can search data.
Note When you do not perform any operation for 6 sec, the “MEM” display disappears, and
the machine goes back to the measurement mode.
[3] Press the “CLEAR” key while the memory number and measurement value are displayed in
turn, “CLR” is blinking on the liquid crystal panel.
Note When you do not perform any operation while “CLR” is blinking, the measurement
becomes available. (No data is deleted.)
[4] Press the “CLEAR” key again while “CLR” is blinking, and “- - - -“ is displayed on the liquid
crystal panel, and the selected data is deleted.
(3) Deletion by specifying the range of the memory data
[1] Press the “MEM/OUTPUT” key, and “MEM” is displayed at the bottom of the liquid crystal
panel, and the last saved data number and measurement value are displayed in turn.
[2] Press the “UP” key or “DOWN” key to display the first data of the data that you want to delete.
[3] Press the “CLEAR” key while the memory number and measurement value are displayed in
turn, and “CLR” is blinking on the liquid crystal panel.
[4] When you press the “UP” key, the memory number increases. Press the key until the memory
number of the last data in the range you want to delete is displayed.
[5] When you press “CLEAR” key while the memory number and measurement value are
displayed in turn, “- - - -“ is displayed on the liquid crystal panel, and the data in the selected
range is deleted.
Note When any data in the memory is deleted, the succeeding data moves up to the deleted
memory position.
(4) Deletion of all memory data
[1] Press the “CLEAR” key for 4 sec or more, “ALL” is displayed on the liquid crystal panel.
[2] Pressing the “CLEAR” key a second time while [ALL] is displayed on the liquid crystal panel will make
[CLR] display. Pushing “CLEAR” again will result in [- - - -] being displayed, deleting all data.

11
Note When you perform no operation while “ALL” or “CLR” is blinking on the liquid crystal
panel, the measurement becomes available.
(Data is not deleted.)
6-5. External output
(1) Serial output
This product comes with output terminals connectable to products compliant to the specifications of
Mitsutoyo Digimatic manufactured by Mitsutoyo Corp.
For the details of the serial output specifications, consult us.
Recommended product: Digimatic Mini-Processor manufactured by Mitsutoyo Corp.
•Input tool (IT-012U) by Mitsutoyo Corp.
(2) Analog output
Specifications
Load impedance > 1k
Note As analog outputs, this product always produces identical waveforms regardless of the mode
activated by the measurement mode selector MODE. The output voltages of each model will
be as per the specifications indicated in 4.
This product comes optionally with an analog output cable DLW9080.
(3) USB output
The output data is output in the ASCII format via a USB cable.
You can download the import software “DSS-3” (supported OS: Windows 98 to Windows 7) from
our website www.nitto-kohki.co.jp. Please note that the software might not work in some PCs.
To import the data, you need to install the import software “DSS-3” and driver software.
Download the latest version of “VCP Drivers” from FTDI Chips Virtual COM Port Drivers
http://www.ftdichip.com/Drivers/VCP.htm and make the setting of the driver.
(3-1) Setting of PC
[1] Download “VCP Drivers” and decompress the saved file.
[2] Move the decompressed file to the desktop or other location where you can access easily.
[3] Connect the torque checker to the PC with a USB cable.
* Turn on the power of the torque checker.
[4] The new hardware detection wizard window is displayed on the PC monitor. Select “No. Not
connect now” and click “Next”.
[5] Go to the next page, select “Install from a list or specified location”, and click “Next”.
[6] Go to the next page, select “Include the following locations”, and click “Reference (R)”.
[7] Select the decompressed file in Reference, and press “OK”.
[8] When the installation is completed, the new hardware search wizard completion window is
displayed. Press Finish to exit.
[9] To check that the installation is done, move the cursor on “My Computer” and right-click on it,
select “Manage”, and open the “Manage Computer” window. Select “Device Manager”.
[10]Click “Port (COM and LPT)” in the tree on the right side of Device Manager, and “USB Serial
Port (COM*) ” is displayed.
Note The number after COM varies according to the computer. When you make the setting of
the communication software, you need to specify the COM port. Please check the
setting.
Note If USB Serial Port is not displayed when you select “Port (COM and LPT)”, disconnect
the USB cord and connect it again, and then install the driver again.
(3-2) Communication setting of import software “DSS-3”
[1] Select “Communication condition setting” in “Setting” in the menu.
[2] Set “19200,n,8,2” to the “Communication Speed” setting.
[3] Make the appropriate setting to “COM Port” in accordance with the COM port of your PC.
Note For information on the COM port numbers, refer to [8] to [10] in the setting of the VCD
Drivers.

12
Specifications
Data bit length
Start bit, 1 bit + 8 bits + 2 stop bits + no parity
Baud rate
19200bps
Connector shape
USB (B type)
Format
18
OE
20
±
20
OF
OD
CAN
*
SO
Space
Code
Measurement
Space
SI
Unit
CR
All data 21
CAN : Cancel
* : In memory mode = number of samples / in normal mode = space
SO : Specifies enlarged printout with double width.
± : + tighten/- reverse
Measurement code: Includes a decimal point. If no decimal point, a space at the end.
1 0 . 0 0 10.00
SI : Releases the enlarged printout with double width.
Unit : In N•m or otherwise, the rest is a series of spaces.
N • m N•m ( k g f •C m kgf•cm )
CR : Carriage return
6-6. How to output data
Data is output every time the “CLEAR” key is pressed after measurement is completed. If the auto
reset is set, data is automatically output.
When you save the data using the memory function, the data is output with the procedure given below:
[1] Press the “MEM/OUTPUT” key, and the last saved memory number and measurement value
are displayed in turn.
[2] Press the “MEM/OUTPUT” key while the data number and measurement value are displayed.
[3] After “FA” (First Address) is displayed on the liquid crystal panel, the memory number is
displayed. Select the first memory number you want to output using the “UP” or “Down” key,
and then press the “MEM/OUTPUT” key.
[4] After “LA” (Last Address) is displayed on the liquid crystal panel, the memory number is
displayed. Select the last memory number you want to output using the “UP” or “Down” key,
and then press the “MEM/OUTPUT” key.
[5] “-P-“ is displayed on the liquid crystal panel, and the data is output. When output is finished,
the machine goes back to the measurement mode.
Note When you press the “CLEAR” key for 1 sec or more, the data output mode is cleared.
6-7. Changing data output speed
You can change the speed to output the saved data.
Note When you output the data in the high speed output setting, it might result in an error depending
on your PC and peripherals. If an error occurs, use the normal output mode.
•Normal output: [00] is displayed on the liquid crystal panel. •High speed output …[01] is
displayed on the liquid crystal panel.
* The default setting is [00].
•How to change the output speed
[1] Turn on the power by pressing the “ON/OFF” key as holding down the “PRG” key while the
power is OFF.
[2] When you let go the “PRG” key, “00” or “01” is displayed on the liquid crystal panel. Press the
“UP” key, and the speed setting is switched.
[3] After selecting the speed, press the “PRG” key, “-5-“ is displayed on the liquid crystal panel.
Then, the machine goes back to the torque display, and measurement becomes available.

13
6-8. Judgment function and peak down setting
Whether the measurement result is within the standard values or not judged, and the judgment result is
notified using lamps and/or buzzers.
The judgment is executed only when the measuring mode is PP (peak mode). (The measurement value
must be 10 digits or higher.)
In the case that the measuring mode is PD (peak down), when a higher value than the peak down
setting is detected, it is notified by a green lamp. The green lamp keeps ON and the numeric value is
retained until the “CLEAR” key or “UP” key is pressed.
Judgment
Lower limit or less *
Within upper and
lower limits
Upper limit or more
Over torque
Lamp
Red lamp (NG) is
blinking (slow).
Green lamp (GOOD)
is ON.
Red lamp (NG) is
blinking (fast).
Red lamp (NG) is
ON.
Buzzer
Intermittent sound
(slow)
Continuous sound
Intermittent sound
(fast)
Continuous sound
* Lower limit or less*: It is detected when the load during measurement almost disappears (less than
15 digits) while it does not reach the lower limit value. (It is not detected when the maximum value
does not reach 15 digits.)
(1) Setting of Judgment
[1] Press the “PRG/SET” key for 1 sec, and the green LED (GOOD lamp) is turned ON, and “HI”
is displayed on the liquid crystal panel, and then the upper limit value is displayed.
* The green LED (GOOD lamp) is ON during the setting mode.
[2] To set the upper limit value, select the digit by pressing the “DOWN” key. When the selected
digit is blinking, change the numeric value by pressing the “UP” key. After setting the value,
press the “DOWN” key again, select the digit, and the change the numeric value using the
“UP” key.
[3] When you finish the setting, press the “PRG/SET” key. “LO” is displayed on the liquid crystal
panel, and then the lower limit value displayed.
[4] To set the lower limit value, perform the same operation explained in [2]. After the lower limit
value is set, press the “PRG/SET” key.
Note When the lower limit value is larger than the upper limit value, the judgment is not
performed.
[5] Make the setting of the peak down start value. “PdLO” is displayed on the liquid crystal panel,
the peak down start value is displayed. To make the setting, perform the same operation
explained in [2].After the peak down start value is set, press the “PRG/SET” key.
Note Peak down works (is displayed) when the measurement value is lowered by 15 digits or
more from the setting value.
[6] Make the setting of the buzzer. After “6P” is displayed on the liquid crystal panel, the ON, OFF,
FF settings are displayed. Make the setting of the buzzer using the “UP” and “DOWN” keys.
After the setting is finished, press the “PRG/SET” key.
(“On”: Buzzer sounds in all cases; “OFF”: Buzzer does not sound except in the case of over
torque; “FF”: Buzzer sounds only in the case of NG)
[7] “-5-“is displayed on the liquid crystal panel, and the setting is finished. The green LED
(GOOD lamp) is turned OFF.
* To cancel the setting, press the “CLEAR” key. ”-5-“ is displayed on the liquid crystal panel,
and the measurement becomes available. The green LED (GOOD lamp) is turned OFF.
* You can check the currently specified numeric values by stopping the numeric values on the
liquid crystal panel from blinking (by pressing the “DOWN” key) and pressing the “MODE”
key.
(“HI”: Upper limit value setting; “LO”: Lower limit value setting; “PdLO”: Peak down start
value; “6P”: Buzzer setting)
(2) Measurement Method Using Judgment
[1] Set the upper limit value and lower limit value which are used as the standard values. For
information on how to set them, refer to Step (1) in 6-8.
[2] Check that the measuring mode is “PP”. * The judgment works only when the measuring mode
is “PP”.

14
[3] When the measurement value is larger than the lower limit value or lower than the upper limit
value, the GOOD lamp is turned ON.
When the measurement value is larger than the upper limit value or lower than the lower limit
value, the NG lamp is turned ON.
[4] When the measurement is finished, press the “UP” key when you save the numeric value, and
press the “CLEAR” key when you restore 0 to the display value. At this point, the lamp and
buzzer used for the judgment result are turned OFF.
* If you do not use the judgment function, set 0 to the upper limit value and lower limit value,
or set a larger value to the lower limit value than the upper limit value.
6--9.Maximum, minimum, and average values calculation function
You can display and check the maximum value, minimum value, average value, and number of data of
the measurement values.
Up to 30 data can be calculated. If the number of data exceeds 30, the oldest data is deleted, and new
data is calculated.
(1) How to measure maximum value, minimum value, and average value
[1] Check if the measuring mode is “PP” or “PD”.
[2] Press the “AVE” key. “AVE” is blinking at the bottom of the liquid crystal panel.
[3] Perform the torque measurement. Press the “UP” key when you add the numeric value in the
calculation, and press the “CLEAR” key when you clear the numeric value and set 0 to the
display value. Repeat this operation.
[4] After the measurement is finished, press the “AVE” key to display the number of the data,
maximum value, minimum value, and average value.
[5] The number of the data (no display at the bottom of the liquid crystal panel), maximum value
(“MAX” at the bottom of the liquid crystal panel), minimum value (“MIN” at the bottom of the
liquid crystal panel), and average value (“AVE” at the bottom of the liquid crystal panel) are
displayed in this order on the liquid crystal panel.
* When you measure new maximum value, minimum value, and average value, the previously
saved data become invalid.
6-10. Recharging
(1) Automatic power-off
This product will power itself off if it is left for 10 minutes or if the battery level is low.
(2) Battery charger
The battery has a limited life span. If you find that it only lasts for an extremelyshort time after fully
charged, or if you find anysimilar problem, please consult the shop where you bought the product.
(3) How to recharge the battery
When the battery level on the liquid crystal panel is low, insert the connector of the supplied battery
charger to the “DC IN” terminal to charge the battery. The charge is finished when the lamp next to
the “DC IN” terminal turned OFF, and the battery level on the liquid crystal panel is full.
Note
Overcharge may cause a battery burst, heat-up, or leak, resulting in a fire or injury. As a battery
charger, always use a DLE1833A
CONTAINS NICKEL-METAL HYDRIDE
BATTERY.MUST BE RECYCLED
OR DISPOSED OF PROPERLY.
This product uses a nickel-metal hydride battery. Nickel-metal hydride batteries are a recyclable,
precious resource. If you find that it only lasts for a short time after a full recharge, consult the shop
where you bought this product.
(4) How to replace the plug of the battery charger
How to install the plug for Japan and the US (A type) and the plug for Europe (C type)
[1] Slide the circled part of the plug mounted on the battery charger in the arrow direction.
[2] You can remove the plug by sliding the circled section.
[3] You can mount the A type or C type plug to the battery charger with the plug removed.
Note When you use the battery charger in Japan, be sure to use theA type plug.

15
6-11.Resetting of the system
In some case, the CPU inside the device may not be activated when the power is on with a Ni-MH
battery charged after fully discharged (due to being left unused for a long time). In such a case, push
the RESET button once.
The system will restore the initial state (all the contents of the memory will be deleted). (A RESET
button is located next to the power button.)
The system should not be reset except in the conditions below indicated.
•In the case no digits shall be displayed on the liquid crystal panel when the power is turned ON with
the connection of an AC adaptor after the system has been left unused for a long time.
•In the case, other than the above, the measurement instrument cannot operate.
Set up the system again when the system is reset because all the contents of the memory shall be
deleted.
7.Examining and calibrating the Torque Checker
It is recommended to have the product examined about once a year.
To calibrate it, follow the procedure described below.
We are ready to calibrate it for you if you wish. If so, consult the shop where you bought the product.
[1] For a calibration and inspection, provide a sash weight, pulley, and fastening table as shown in the
figure below.
[2] Engage the pulley with the torque detector.
[3] With the tap of the socket, fasten the pulley by means of screws or something similar.
[4] Fasten the Torque Checker on the table.
[5] Disable the automatic resetting, then set the measurement mode to TR.
[6] Suspend the sash weight on the pulley, then take the readings (for both forward and reverse
revolutions).
A type plug
Battery charger
(DLE1833A)
台に本体を固定
プーリー
分銅
Fasten the product
on the table.
Torque
Checker
Pulley
Sash weight
A type plug
For Japan and US
C type plug
For Europe
Either
one

16
*Standard values
DLT1173A DLT1673A
Pulley diameter 199.5mm
Pulley diameter 399mm
Weight of
sash weight
[kg]
0.1
0.5
1.0
1.5
Weight of
sash weight
[kg]
0.5
1.5
2.5
5.0
Measured
torque [N•m]
0.098
0.490
0.981
1.471
Measured
torque [N•m]
0.98
2.94
4.90
9.81
Standard
value
1 digit
±0.5% (F.S.)
Standard
value
1 digit
±0.5% (F.S.)
DLT1973A
Pulley diameter 399mm
Weight of sash
weight [kg]
2.0
4.0
6.0
7.5
Measured torque
[N•m]
3.92
7.85
11.77
14.71
Standard value
±0.5% (F.S.)
This manual suits for next models
2
Table of contents
Popular Test Equipment manuals by other brands

Daikin
Daikin RSEYP16KJY1 Design, installation & testing instructions

Tektronix
Tektronix TDS2000C series manual

Viavi
Viavi MTS 2000 user manual

GESTRA
GESTRA NRA 1-3 Original Installation Instructions

Commercial Electric
Commercial Electric DUALCHECK CE-VD7504GFI Use and care guide

Teledyne Lecroy
Teledyne Lecroy WaveSurfer 3000 Operator's manual