Nivus NivuFlow Mobile 600 User manual

FLOW permanent
Instrumentation for Water Industry
NIVUS GmbH • Im Taele 2 • Germany-75031 Eppingen • Internet: www.nivus.com
Flow Measurement Transmitter
NivuFlow 600
Instruction Manual
Firmware Revision: 2.3.X
Document revision: rev. 03 / 22.10.2019
Original Manual: German / rev. 03 as of 25.09.2019
Revised manual

Branches
page 2 NF 600 - rev. 03 / 22.10.2019
NIVUS AG, Switzerland
Burgstrasse 28
8750 Glarus, Switzerland
Phone +41 (0)55 6452066
Fax +41 (0)55 6452014
www.nivus.de
NIVUS, Austria
Muehlbergstrasse 33B
3382 Loosdorf, Austria
Phone +43 (0)2754 567 63 21
Fax +43 (0)2754 567 63 20
www.nivus.de
NIVUS Sp. z o.o., Poland
ul. Hutnicza 3 / B-18
81-212 Gdynia, Poland
Phone +48 (0)58 7602015
Fax +48 (0)58 7602014
www.nivus.pl
NIVUS, France
17 Rue du Stade
67870 Bischoffsheim, France
Phone +33 (0)388 9992 84
www.nivus.fr
NIVUS Ltd., United Kingdom
Wedgewood Rugby Road
Weston under Wetherley
Royal Leamington Spa
CV33 9BW, Warwickshire
Phone +44 (0)8445 3328 83
www.nivus.com
NIVUS Middle East (FZE)
Building Q 1-1 ap. 055
P.O. Box: 9217
Sharjah Airport International
Free Zone
Phone +971 6 55 78 224
Fax +971 6 55 78 225
www.nivus.com
NIVUS Korea Co. Ltd.
#2502, M Dong, Technopark IT Center,
32 Song-do-gwa-hak-ro,
Yeon-su-gu,
INCHEON, Korea 21984
Phone +82 32 209 8588
Fax +82 32 209 8590
www.nivus.com
NIVUS Vietnam
21 Pho Duc Chinh, Ba Dinh,
Hanoi, Vietnam
Phone +84 12 0446 7724
www.nivus.com

Copyrights and property rights
page 3NF 600 - rev. 03 / 22.10.2019
Copyrights and property rights
This document and its contents are proprietary to NIVUS GmbH and are not to be reproduced
or copied without the express written permission of NIVUS GmbH.
Violations will be liable for compensation.
Important Note
This instruction manual may exclusively - even in parts - be copied or translated in any
other way with the express written consent of NIVUS GmbH.
Translation
If the device is sold to a country in the European Economic Area (EEA) this instruction manual
must be translated into the language of the country in which the device is to be used.
Should the translated text be unclear, the original instruction manual (German) must be consul-
ted or one of the legally associated companies and subsidiaries of NIVUS group contacted for
clarification.
Copyright
No part of this publication may be reproduced, transmitted, sold or disclosed without prior
permission. Damages will be claimed for violations.
All rights reserved.
Names
The use of general descriptive names, trade names, trademarks and the like in this manual
does not entitle the reader to assume they may be used freely by everyone. They are often
protected registered trademarks even if not marked as such.

Instruction Manual
NivuFlow 600
page 4 NF 600 - rev. 03 / 22.10.2019
Document modifications
Rev. Modications Editor in
charge
Date
03 Complete revision: many features and functions added, layout redesi-
gned etc.
MoG 22.10.2019
02 Section “33.4 Alignment” modied MoG 27.02.2019
01 Minor modications; no approval DMR 25.04.2016
00 First version based on the German document DMR 21.12.2015

Contents
page 5NF 600 - rev. 03 / 22.10.2019
Contents
COPYRIGHTS AND PROPERTY RIGHTS 3
DOCUMENT MODIFICATIONS 4
GENERAL 11
1 About this manual ....................................................................................11
1.1 Applicable documentation ................................................................................. 11
1.2 Signs and denitions used ................................................................................12
1.3 Abbreviations used.............................................................................................12
2 Connections and Operating Elements .................................................. 12
2.1 Power Supply .....................................................................................................12
2.2 NivuFlow Operating Elements............................................................................13
2.3 Tasks of control elements...................................................................................13
2.4 Interfaces ...........................................................................................................14
SAFETY INSTRUCTIONS 15
3 General: Used Symbols and Signal Words........................................... 15
3.1 Valuation of the accident level............................................................................15
3.2 Warning notices on the product (option) ............................................................16
4 Safeguards and Precautions .................................................................. 16
5 Warranty ................................................................................................... 17
6 Liability Disclaimer.................................................................................. 17
7 Use in accordance with the requirements ............................................ 18
8 User’s Responsibilities ........................................................................... 18
9 Personnel requirements ......................................................................... 19
DELIVERY, STORAGE AND TRANSPORT 20
10 Delivery .................................................................................................... 20
11 Reception inspection .............................................................................. 20
12 Storage .................................................................................................... 20
13 Transport .................................................................................................. 20
14 Return ....................................................................................................... 20

Instruction Manual
NivuFlow 600
page 6 NF 600 - rev. 03 / 22.10.2019
PRODUCT SPECIFICATION 21
15 Product Construction and Overview ..................................................... 21
15.1 Dimensions of enclosure....................................................................................22
15.2 Connectable sensors ........................................................................................23
15.3 Device identication ..........................................................................................23
16 Specications .......................................................................................... 24
17 Conguration .......................................................................................... 26
17.1 Device Types .....................................................................................................26
FUNCTIONAL DESCRIPTION 27
18 Operating Ranges.................................................................................... 27
19 Functional Principle ................................................................................ 28
19.1 Flow velocity detection .......................................................................................28
19.2 Flow Calculation.................................................................................................29
INSTALLATION AND CONNECTION 30
20 General Installation Instructions............................................................ 30
20.1 Avoidance of electrostatic discharge (ESD).......................................................30
20.2 Installation and Mounting versions.....................................................................30
20.3 Choosing the installation place ..........................................................................31
20.4 Transmitter fastening on DIN rail in control cabinets..........................................31
20.5 Field enclosure fastening and preparing electric installation .............................32
21 Electrical Installation............................................................................... 34
21.1 Wiring to the Terminal Blocks ...........................................................................34
21.2 Plans of terminal connections ..........................................................................36
21.3 Switching on voltage supply ..............................................................................41
21.3.1 Power supply DC............................................................................................41
21.3.2 Power supply AC ............................................................................................42
21.4 Relays ................................................................................................................43
22 Installation and Connection of Sensors................................................ 43
22.1 Sensor Installation Principles .............................................................................43
22.2 Installation of Clamp-On Sensors ......................................................................44
22.3 Installation of Wet Sensors ................................................................................44
22.4 Path arrangements.............................................................................................44
22.5 Cable and Cable length for connecting the sensors ..........................................45
22.6 Sensor Connection to NivuFlow.........................................................................45
22.6.1 Sensor connection 1-path measurement / 2-path measurement ..................45
22.7 Connection to/via Extension module NFE..........................................................47
23 Overvoltage Protection Measures ......................................................... 48
23.1 Overvoltage Protection for Power Supply ..........................................................48
23.2 Overvoltage Protection for mA-Inputs/Outputs ..................................................50

Contents
page 7NF 600 - rev. 03 / 22.10.2019
23.3 Overvoltage protection for communication interfaces ........................................50
23.4 Overvoltage protection for (transit time) sensor connectors ..............................51
23.4.1 Basic protection - equipotential bonding cable...............................................51
23.4.2 Extended protection - overvoltage protection “SonicPro T”...........................51
OPERATION START-UP 54
24 Notes to users.......................................................................................... 54
25 Operation Basics ..................................................................................... 55
25.1 Display Overview ...............................................................................................55
25.2 Using the Control elements ...............................................................................55
25.3 Use/Entry using the letter block ........................................................................56
25.4 Use/Entry using the numeric keypad ................................................................57
25.5 Revision of parameters .....................................................................................58
25.6 Menus ................................................................................................................58
26 Measurement with Clamp-On Sensors.................................................. 59
27 Measurement with wet sensors ............................................................ 60
START-UP EXAMPLES 61
28 Programming a 1-path diametrically opposed Measurement ............ 61
28.6.3 Simple Parameter Setting .............................................................................61
28.6.4 Extended Parameter Setting ..........................................................................64
SETTING PARAMETERS 65
29 General Programming ............................................................................ 65
29.1 Save Parameters ..............................................................................................65
29.2 Change Password .............................................................................................65
30 Parameter Functions............................................................................... 66
30.1 Main Menu ........................................................................................................66
30.2 Overview: Functions Top Menu Level ................................................................66
30.2.1 Application Menu / MP1 / MP2 / Combi..........................................................66
30.2.2 Data Menu .....................................................................................................67
30.2.3 System Menu .................................................................................................68
30.2.4 Communication Menu ....................................................................................69
30.2.5 Display Menu..................................................................................................69
30.2.6 Connections Menu .........................................................................................70
31 Application / MP1 / MP2 / Combi Parameter Menu ............................... 70
31.1 Setting parameters in Measurement place Menu .............................................70
31.1.1 Active..............................................................................................................71
31.1.2 Name of Measurement Place ........................................................................71
31.1.3 Transit Time Mode..........................................................................................72
31.1.4 Number of Paths ............................................................................................73

Instruction Manual
NivuFlow 600
page 8 NF 600 - rev. 03 / 22.10.2019
31.1.5 Medium...........................................................................................................73
31.1.6 Medium Temperature......................................................................................73
31.1.7 Channel Proles .............................................................................................73
31.1.8 Wall Material...................................................................................................74
31.1.9 Lining..............................................................................................................74
31.1.10 Sludge Level...................................................................................................75
31.1.11 3D-Preview.....................................................................................................75
31.1.12 Flow velocity analysis.....................................................................................75
31.1.13 Low-Flow Suppression ...................................................................................75
31.1.14 Damping .........................................................................................................76
31.1.15 Stability...........................................................................................................76
31.2 Setting parameters in Measurement place Combi Menu ..................................77
31.3 Setting parameters in v-Paths Menu..................................................................77
31.3.1 Active..............................................................................................................77
31.3.2 Sensor Types in >Clamp-On< Transit Time Mode..........................................78
31.3.3 Sensor Types in >Wet< Transit Time Mode....................................................78
31.3.4 Sensor Mounting Position ..............................................................................79
31.3.5 Weighting and Hydraulic Factor .....................................................................81
31.3.6 v-Minimum and v-Maximum ...........................................................................81
31.3.7 v-Path Error ....................................................................................................81
31.4 Setting parameters in Inputs and Outputs (analog and digital) Menu ................81
31.4.1 Analog Inputs .................................................................................................82
31.4.2 Analog Outputs...............................................................................................83
31.4.3 Digital Inputs...................................................................................................84
31.4.4 Digital Outputs................................................................................................86
31.5 Setting Parameters in Diagnostics Menu ..........................................................88
32 Data Parameter Menu.............................................................................. 88
32.1 Trend..................................................................................................................88
32.2 Total....................................................................................................................91
32.3 Day Totals ..........................................................................................................91
32.4 USB stick............................................................................................................93
32.5 Data storage.......................................................................................................96
32.6 Operating hours ................................................................................................97
33 System Parameter Menu......................................................................... 97
33.1 Information .........................................................................................................97
33.2 Region settings ..................................................................................................98
33.2.1 (Operation) Language ....................................................................................98
33.2.2 Date Format....................................................................................................98
33.2.3 Units ...............................................................................................................98
33.2.4 Data Units.......................................................................................................99
33.3 Time/Date.........................................................................................................101
33.4 Error messages ...............................................................................................102

Contents
page 9NF 600 - rev. 03 / 22.10.2019
33.5 Service ............................................................................................................102
33.5.1 Service Level................................................................................................103
33.5.2 Change (System) Password.........................................................................103
33.5.3 Reboot..........................................................................................................103
33.5.4 Restart Measurement...................................................................................104
33.5.5 Parameter reset............................................................................................104
33.5.6 Update NivuFlow ..........................................................................................104
34 Communication Parameter Menu ........................................................ 105
35 Display Parameter Menu....................................................................... 107
36 Connections Parameter Menu ............................................................. 109
MAIN DISPLAY 110
37 General overview ...................................................................................110
37.1 Display Flow in measurement places 1 and 2.................................................. 112
37.2 Display Level in measurement places 1 and 2................................................. 112
37.3 Display Velocity in measurement places 1 and 2 ............................................ 113
37.4 Display Temperature in measurement places 1 and 2 ..................................... 113
37.5 Display Sum in measurement places 1 and 2.................................................. 114
37.6 Display Trend/Hydrograph in measurement places 1 and 2 ............................ 114
37.7 Display Flow in measurement place Combi ..................................................... 115
37.8 Display Measurement Place 1/2 in measurement place Combi....................... 115
37.9 Display Total in Measurement Place Combi..................................................... 116
DIAGNOSTICS 117
38 Diagnostics Menu Principles.................................................................117
39 Diagnostics v-Paths ..............................................................................117
40 Inputs and Outputs (analog and digital)...............................................119
40.1 Analog Inputs ...................................................................................................120
40.2 Analog Outputs ................................................................................................120
40.3 Digital Inputs ....................................................................................................122
40.4 Digital Outputs..................................................................................................122
41 Signal Analysis ...................................................................................... 123
42 Simulation .............................................................................................. 128
ERROR MESSAGES 130
43 Error message indicated, Cause of failure and Troubleshooting ..... 130

Instruction Manual
NivuFlow 600
page 10 NF 600 - rev. 03 / 22.10.2019
MAINTENANCE AND CLEANING 133
44 Maintenance........................................................................................... 133
44.1 Maintenance Interval........................................................................................133
44.2 Customer Service Information..........................................................................133
45 Cleaning ................................................................................................. 134
45.1 Transmitter .......................................................................................................134
45.2 Sensors ............................................................................................................134
46 Dismantling/Disposal ........................................................................... 134
47 Installation of spare parts and parts subject to wear and tear ......... 135
48 Accessories .......................................................................................... 135
INDEX 136
CREDITS AND LICENSES 139
49 List of references of the licenses and codes used ........................... 139
APPROVALS AND CERTIFICATES 140

General
page 11NF 600 - rev. 03 / 22.10.2019
General
1 About this manual
Important note
READ CAREFULLY BEFORE USE.
KEEP IN A SAFE PLACE FOR LATER REFERENCE.
This instruction manual for the flow measurement transmitter NivuFlow 600 is for the intended
use of the device only. This manual is oriented exclusively to qualified expert personnel.
Read this instruction manual carefully and completely prior to installation and connection since
it contains relevant information on this product. Observe the notes and particularly follow the
warning notes and safety instructions.
Keep this manual in a safe place and make sure it is available for the users of this product at
all times.
If you should have problems to understand information contained within this instruction manual
contact one of the legally associated companies and subsidiaries of NIVUS group for further
support. The companies and subsidiaries of NIVUS group cannot be held responsible for
damage to persons or materials due to incorrectly understood information in this instruction
manual.
In the case of selling the instrument this instruction manual shall be provided to the purchaser
since it is a part of the standard delivery.
1.1 Applicable documentation
For the installation and operation of the complete system extra instruction manuals or technical
descriptions may be required apart from this manual.
• Technical Instructions Transit Time Sensors
• Installation Instructions Transit Time Sensors
• Technical Instructions NIVUS MODBUS TCP/RTU Application Interface for measure-
ment transmitters of the series NivuFlow 5xx, 6xx, 7xx and Energy Saver
• Technical Instructions Extension Module NFE
These manuals are provided with the auxiliary units or sensors and/or are available as down-
load on the NIVUS homepage.

Instruction Manual
NivuFlow 600
page 12 NF 600 - rev. 03 / 22.10.2019
1.2 Signs and definitions used
Image Meaning Remark
Ü(Action) Step Action to be performed by you.
Note the numbering of action steps. Observe the
order of the steps.
cCross-reference Refers to further or detailed information.
>Text< Parameter or Menu Indicates a parameter or a menu that is selected
or described.
Reference to docu-
ment
Refers to an accompanying documentation.
Graphics/Table info Additional information in the legend of a graphic
or a table
Table 1-1 Structural elements within the manual
1.3 Abbreviations used
Colour code for wires and single conductors
The abbreviations of colours, wire and components follow the international colour code accor-
ding to IEC 60757.
BK black BN brown RD red
OG orange YE yellow GN green
BU blue VT violet GY grey
WH white PK pink TQ turquoise
GNYE green/yellow GD gold SR silver
2 Connections and Operating Elements
2.1 Power Supply
The connection for the power supply is located on the lower part of the terminal block X1.
1 Power supply DC
2 Power supply AC and earth conductor
Fig. 2-1 Electrical connections of power supply
Fc You can find a detailed connection plan in Sect. “31.4 Setting parameters in Inputs and
Outputs (analog and digital) Menu”.

General
page 13NF 600 - rev. 03 / 22.10.2019
2.2 NivuFlow Operating Elements
The NivuFlow is operated completely in dialogue mode supported by the graphs on the
display. To select individual menus and submenus use the rotary pushbutton as well as both
function keys.
1
2 3
1
4
Graphic display
2 Left function key
3 Rotary pushbutton
4 Right function key
Fig. 2-2 Operating elements
2.3 Tasks of control elements
Colour display
You can read all settings, when setting parameters and in diagnostics.
Left function key (Menu and/or Back)
This key (Menu) takes you from the main display to the main menu. The same key (Back) is
also used to exit the main menu and the submenus.
Rotary pushbutton
Use the rotary pushbutton to enter specific submenus. The functions can be selected using the
rotary pushbutton as well.
• Select the desired parameter or menus
• Navigation through the submenus and settings
• Selection of letters or numbers for parameter setting
Right function key (Input and/or Tab)
This key is used to confirm value entries (via numeric keys or letter keys).
For some parameters the right function key can be used as >Tab<. This Tab function is always
available when digits are visible in the upper right corner of the display. Then the Tab function
is used to switch between pages/displays. This applies to the following settings:
• Menu >Application<
Selecting the v-paths
Selecting the analog inputs / outputs
Selecting the digital inputs / outputs
Diagnostics of the v-paths

Instruction Manual
NivuFlow 600
page 14 NF 600 - rev. 03 / 22.10.2019
Diagnostics of the signal analysis
• Menu >Data<
Selection of Trend, Total and Day totals
Within the programming of multiple inputs/outputs or when programming several v-paths, the
right function key is used to jump from one input/output or v-path to the next.
Fc You will find a description on how to use the control elements in Sect. “25 Operation
Basics”.
2.4 Interfaces
The transmitter is equipped with various interfaces on the front panel.
1 Network interface (LAN)
2 BUS interface (RS485/RS232)
3 HART interface
4 USB-A interface (data transfer, parameter backup, device update)
5 USB-B interface (service)
Fig. 2-3 Available interfaces
Fc Descriptions of the individual interfaces see Sect. “34 Communication Parameter
Menu”.

Safety Instructions
page 15NF 600 - rev. 03 / 22.10.2019
Safety Instructions
3 General: Used Symbols and Signal Words
3.1 Valuation of the accident level
The general warning symbol indicates the risk of personal injuries or death. In the text
section the general warning symbol is used in conjunction with the signal words described
below.
DANGER Warnings in high degree of risk
Indicates a high-risk, imminently hazardous situation which will result in death or serious
injury if not avoided.
WARNING Warnings in medium degree of risk
Indicates a possible danger with medium risk which may result in a life-threatening situa-
tion or (severe) bodily injury if it is not avoided.
CAUTION Warnings in low-risk or property damages
Indicates a possible danger with moderate risk which may result in minor or moderate
personal injury or material damage if not avoided.
WARNING Danger by electric voltage
Indicates a hazard with a high risk of electric shock which may result in a life-threatening
situation or (severe) bodily injury if it is not avoided.
Important Note
Contains information that should be highlighted.
Indicates a potentially damaging situation which can result in damage to the product or to an
object in its environment.
Note
Contains information and facts.

Instruction Manual
NivuFlow 600
page 16 NF 600 - rev. 03 / 22.10.2019
3.2 Warning notices on the product (option)
General warning label
This symbol is for operators to refer to this manual.
Observing the information contained therein is required in order to maintain protection mea-
sures provided by the instrument during installation procedures and operation.
Protective conductor
This symbol refers to the protective conductor of the unit.
Depending on the mode of installation the instrument shall be operated solely connected to
an appropriate protective conductor according to applicable laws and regulations.
4 Safeguards and Precautions
Working with NIVUS instruments requires to observe and to follow the safety measures
and precautions below generally and at any time. These notes and warnings will not be
repeated for each description within the document.
WARNING Germ contamination
Parts can be contaminated with dangerous germs, especially if the sensors are used in
waste water applications. Therefore, appropriate precautions must be taken when contac-
ting cables and sensors.
Wear protective clothing.
WARNING Observe occupational safety regulations
Before starting and while executing installation work, observing the work safety regulations
needs to be checked constantly.
Disregarding these regulations may lead to personal injury.
WARNING Do not disable safety devices!
It is strictly prohibited to disable the safety devices or to change the way they work.
Disregarding this may lead to personal injury or site damage.
WARNING Disconnect the systems from mains
Maintenance, cleaning and/or repairs (by qualified personnel only) may only be performed
when de-energised.
Disregarding this warning may lead to electric shocks.
Putting into operation by trained experts only
The entire measurement system shall be installed and put into operation by trained expert
personnel only.
Integrated buffer battery
The integrated buffer battery may only be exchanged by NIVUS staff or personnel authori-
sed by NIVUS. Infringements lead to a limitation of the warranty (see Sect. “5 Warranty”).

Safety Instructions
page 17NF 600 - rev. 03 / 22.10.2019
5 Warranty
The device has been functionally tested before delivery. If it is used as intended (see Sect.
“7 Use in accordance with the requirements”) and the operating instructions, the applicable
documents (see Sect. “1.1 Applicable documentation”) and the safety notes and instructions
contained therein, are observed, no functional restrictions are to be expected and perfect
operation should be possible.
Fc Please also note in this regard the next Sect. “6 Liability Disclaimer”.
Limitation of warranty
In the event of non-compliance with the safety instructions and instructions in this document,
the companies of the NIVUS group of companies reserve the right to limit the warranty.
6 Liability Disclaimer
The legally associated companies and subsidiaries of NIVUS group assume no liability
• for damages owing to a change to this document. The legally associated companies
and subsidiaries of the NIVUS group reserve the right to change the contents of this
document and this disclaimer at any time and without any notice.
• for damages to persons or objects resulting from failure to comply with applicable
regulations. When connecting, commissioning and operating the sensors, all availa-
ble information and higher local legal regulations (in Germany e.g. VDE regulations)
such as applicable Ex regulations as well as safety requirements and regulations in
order to avoid accidents shall be adhered to.
• for damages to persons or objects resulting from improper use. For safety and
warranty reasons, all internal work on the instruments beyond that involved in normal
installation and connection, must be carried out only by qualified NIVUS personnel or
persons or companies authorised by NIVUS.
• for damages to persons or objects resulting from the use of instruments in technically
imperfect condition.
• for damages to persons or objects resulting from the use of instruments not in accor-
dance with the requirements.
• for damages to persons or objects resulting from failure to comply with safety
information contained within this instruction manual.
• for missing or incorrect measurement values or resulting consequential damages due
to improper installation.

Instruction Manual
NivuFlow 600
page 18 NF 600 - rev. 03 / 22.10.2019
7 Use in accordance with the requirements
Note
The instrument is intended solely for the purpose described below.
Modifying or using the instruments for any other purposes without the written consent of the
legally associated companies and/or subsidiaries of NIVUS group will not be considered as
use in accordance with the requirements.
The legally associated companies and subsidiaries of NIVUS group cannot be held respon-
sible for any damage resulting from improper use. The user alone bears any risk.
The NivuFlow 600 transmitter and associated sensor system is designed for continuous flow
measurement of slightly contaminated to clear, pure water-based liquids in fully filled pipes
(round and rectangular).
The measurement transmitter is designed and manufactured in accordance with the current
state of the art and with the recognised safety rules and regulations applicable at the time this
document is issued. Danger to persons or material damage cannot be completely ruled out,
however.
The maximum permissible limit values as specified in Sect. “16 Specifications” shall be nec-
essarily observed. Any case varying from these conditions which is not approved by NIVUS
GmbH in written form is left at the owner’s risk.
8 User’s Responsibilities
Observe and comply with all guidelines and requirements
In the EEA (European Economic Area) national implementation of the framework directive
89/391/EEC and corresponding individual directives, in particular the directive 2009/104/
EC concerning the minimum safety and health requirements for the use of work equipment
by workers at work, as amended, are to be observed and adhered to. In Germany e.g. the
Industrial Safety Ordinance must be observed.
Make sure to have a local operating permit available and observe the associated conditions.
In addition to this you must observe environmental requirements and local laws on the follow-
ing points:
• Personnel safety (accident prevention regulations)
• Safety of work materials and tools (safety equipment and maintenance)
• Disposal of products (laws on wastes)
• Disposal of materials (laws on wastes)
• Cleaning (cleansing agents and disposal)
Connections
Operators shall make sure prior to operating the instrument that during installation and initial
start-up the local regulations (such as regulations for electrical connection) are observed.

Safety Instructions
page 19NF 600 - rev. 03 / 22.10.2019
9 Personnel requirements
Installation, commissioning and maintenance shall be executed only by personnel meeting the
demands as follows:
• Expert personnel with relevant training and appropriate qualification
• Personnel authorised by the plant operator
Qualified personnel
within the context of this documentation or the safety notes on the product itself are per-
sons who are sufficiently familiar with installation, mounting, starting up and operation of the
product and who have the relevant qualifications for their work; for example:
I. Training, instruction or authorisation to activate/deactivate, isolate, ground, and mark
electric circuits and devices/systems according to the safety engineering standards.
II. Education and instruction according to the standards of safety engineering regarding the
maintenance and use of adequate safety equipment.
III. First aid training

Instruction Manual
NivuFlow 600
page 20 NF 600 - rev. 03 / 22.10.2019
Delivery, Storage and Transport
10 Delivery
The standard delivery of the NivuFlow 600 basically contains:
• Transmitter type NivuFlow 600 (according to shipping documents)
• Instruction manual (incl. certificates of conformity) containing any relevant information
on how to operate the NivuFlow 600
Check extra accessories depending on your order and by using the delivery note.
11 Reception inspection
Check the packaging for visible damage immediately after receipt. Any possible damage in
transit shall be instantly reported to the carrier. Furthermore a written report shall be sent to
NIVUS GmbH in Eppingen.
Incomplete deliveries shall be reported in writing either to your local representative or directly
to the NIVUS GmbH in Eppingen within two weeks.
Important note
Objections cannot be rectified later!
12 Storage
The permissible maximum values regarding ambient conditions such as temperature and
humidity according to Sect. “16 Specifications” shall be necessarily observed.
Protect the instrument from corrosive or organic solvent vapours, radioactive radiation as well
as strong electromagnetic radiation.
Use the original packaging for storage.
13 Transport
Protect the instrument from heavy kicks, impacts, shocks or vibrations.
Use the original packaging for transport.
Otherwise, the same rules apply with regard to external influences as for storage (see Sect.
“12 Storage”).
14 Return
In case of a required reshipment return the unit at customer cost to NIVUS GmbH in Eppingen
using the original packaging.
Insufficiently franked shipments will not be accepted!
Other manuals for NivuFlow Mobile 600