1. The Wireless Door/Window Contact with Local Bypass
(2GIG-DW40-345) is designed for installaon on doors,
windows, and other items having an open/close feature.
It communicates with the control panel using the 2GIG
protocol.
2. Figure 1. Wireless Door Contact Components
Box Contents
Verify that the package contains the following:
•1—Wireless Door/Window Sensor with Baery
•1—Adhesive Tape for Sensor
•1—Magnet
•1—Adhesive Tape for Magnet
•2—Phillips Screws
Activating Contact
To acvate the baery in contact, pull out the plasc baery
pull tab and discard it. A red LED will flash 5 mes to indicate
that the bypass buon is enabled.
Figure 2. Removing the Plastic Battery Pull Tab
Mounting Orientation
Before mounng the contact and magnet check the mounng
orientaon (See Figure 3). There are three (3) lines on the
contact and they must face the magnet.
Figure 3. Contact/Magnet Orientation
CONTACT
MAGNET
3 LINES
MUST FACE
MAGNET
5/8”
MAX.
HIDDEN
LED
5/8”
MAX.
RIGHT MOUNTED
CONTACT
LEFT MOUNTED
CONTACT
Mount the contact on the staonary part of the window or door.
Mount the magnet on the moving part of the window or door.
A 5/8”(15.875mm) maximum distance is allowed between the
magnet and contact.
Figure 4. Contact/Magnet Location on a Window or Door
Contact Mounting Methods
First determine if the local bypass buon will be used. The
local bypass buon is enabled by default. Disabling the buon
provides higher security if used as a door/window contact only.
Please see reverse side on instrucons to enable or disable the
local bypass buon.
Select the mounng method that will be used. If the installaon
conforms to UL, open the contact base using a coin in the slots
(See Figure 5). Fasten the contact base permanently to locaon
using the Phillips screws (provided). See Figure 6.
Figure 5. Opening Contact
Figure 6. Permanently Mounting Contact Base
Figure 7. Double-Stick Tape Mounting Contact & Magnet
If installaon is not for a UL installaon, the contact can be
fastened into posion using double-sck tape. (See Figure 7).
1. Clean and dry the surface of the mounng locaons.
2. Apply the adhesive strips to the contact and magnet.
3. Use firm pressure to adhere the contact to the desired
locaon. NOTE: For best results, avoid mounng the
adhesive tape at temperatures below 50°F (10°C). Aer
24 hours, bond will hold at lower temperatures.
ADHESIVE STRIP
FOR MAGNET
MAGNET
ADHESIVE STRIP
FOR CONTACT
CONTACT
PHILLIPS
SCREWS (2)
PULL & DISCARD
BEFORE USE
PLASTIC
BATTERY PULL
TAB
CONTACT
CONTACT
COIN
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,2GIG-DW40-345 - P/N: 10005518 X12 - INK: BLACK - MATERIAL: 16 LB. MEAD BOND - SIZE: 6.000" X 8.000" - TOL. +/- 0.125”- SCALE: 1-1 - FOLDING: 4X TO 1.5" x 2" SIDE 1 OF
2
CONTACT BASE
PHILLIPS
SCREWS
CONTACT IS ATTACHED
TO STATIONARY LOCATION
MAGNET
MAGNET
REMOVE BACKING
MAGNET CONTACT
DOUBLE-STICK TAPE
DOUBLE-STICK
TAPE

Using the Bypass Mode
The 2GIG-DW40-345 Wireless Door/Window Contact has a local
bypass feature. This means that the contact allows opening of
a protected door or window without sending a signal to the
control panel.
Figure 8. Push Bypass Button
To operate the bypass feature:
1. With door closed, press and hold the bypass buon on the
contact unl LED turns on. If the LED is offand the door is
closed, press and hold the local bypass buon down again
unl the LED turns on.
2. Now open door.
The LED will remain on for up to 30 seconds and indicates that
the door can be opened without sending a signal to the panel.
This local bypass event will be logged on panels with soware
that supports the Bypass Sensor Log feature. The LED will flash
once every ten (10) seconds to indicate that bypass mode is
acve.
3. To deacvate bypass mode, simply close the door. A status
message will be sent to the alarm panel indicang that the
bypass mode has now been canceled. Note: Status message
will only show on panels with soware that supports the
Bypass Sensor Log feature.
Disable the Bypass Feature
If the contact is not opened yet, refer to Figure 5 on reverse
side of this page.
1. Pry the baery out of sensor base using a flat blade screw-
driver. Note locaon of tamper buon.
Figure 9 . Battery and Tamper Button
2. Insert baery + side up, while holding tamper buon
for three (3) seconds or more to toggle enable/disable
of bypass feature. NOTE: The red LED will flash once to
indicate that the bypass feature is disabled.
3. Release the tamper buon. This feature will remain
disabled even if the baery is replaced
Figure 10. Tamper Button Activation
Re-enable Bypass Feature
Repeat steps 1-3 under Disable the Bypass Feature.
NOTE: The red LED will flash five (5) times to indicate that
the bypass feature is enabled.
Checking Local Bypass Function Status
1. Remove and re-install baery into contact.
2. LED will flash five (5) mes to indicate local bypass
buon is enabled or one (1) me if disabled.
Inserting and Replacing Battery
To insert or replace battery:
1. Remove contact base. See Figure 5 on reverse side
2. Remove the baery (See Figure 8). Removing the cover
triggers a zone tamper signal, which is transmied to the
control panel.
3. Insert the baery with the +side up, then snap sensor base
and cover back together.
IMPORTANT: Always dispose and/or recycle used baeries in accordance with
the hazardous waste recovery and recycling regulaons for your locaon. Your
city, state, or country may also require you to comply with addional handling,
recycling, and disposal requirements.
WARNING: Failure to follow these warnings and instrucons can lead to heat
generaon, rupture, leakage, explosion, fire, or other injury, or damage. Do
not insert the baery into the compartment in the wrong direcon. Always
replace the baery with the same or equivalent type (See Specificaons). Never
recharge or disassemble the baery. Never place the baery in fire or water.
Always keep baeries away from small children. If baeries are swallowed,
promptly see a doctor.
Specifications
Frequency 345 MHz
Battery 3-Volt CR2013 Battery (or Equivalent)
Magnet 5/8” max. gap
Operating Temperature 32°-120°F
Humidity 5-95% RH non-condensing
Compatibility 2GIG receivers
Supervisory Interval Approximately 70 minutes
Wireless Signal Range 275 ft (80m) open air with 2GIG panel
Regulatory Information
WARNING: Changes or modifications not expressly approved by Nortek
Security & Control could void the user’s authority to operate the
equipment.
This device complies with FCC Part 15 Rules and Industry Canada
licence-exempt RSS standard(s). Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this
device must accept any interference, including interference that may
cause undesired operation of the device.
Cét appareil est conforme la norme d’Industrie Canada exempts de licence
RSS. Son fonctionnement est soumis aux deux conditions suivantes: (1)
cét appareil ne peut pas provoquer d’interférences, et (2) c’et appareil
doit accepter toute interférence, y compris les interférence, y compris
les interférences qui peuvent causer un mauvais fonctionnement de la
dispositif.
FCC ID: WDQ-DW40345 IC: 7794A-DW40-345
Limited Warranty
This Nortek Security & Control LLC product is warranted against defects
in material and workmanship for two (2) years. This warranty extends
only to wholesale customers who buy direct from Nortek Security &
Control LLC or through Nortek Security & Control normal distribution
channels. Nortek Security & Control does not warrant this product to
consumers. Consumers should inquire from their selling dealer as to the
nature of the dealer’s warranty, if any.
There are no obligations or liabilities on the part of Nortek Security &
Control for consequential damages arising out of or in connection with
use or performance of this product or other indirect damages with respect
to loss of property, revenue, or profit, or cost of removal, installation, or
reinstallation. All implied warranties for functionality, are valid only until
the warranty expires. This Nortek Security & Control Warranty is in lieu
of all other warranties expressed or implied.
2GIG
Nortek Security & Control LLC
1950 Camino Vida Roble, Suite 150
Carlsbad, CA 92008-6517 USA
For technical support in the US and Canada:
855-2GIG-TECH (855-244-4832)
Email: [email protected]
Visit www.2GIG.com or dealer.2gig.com for technical support hours of operation
For technical support outside of the USA and Canada:
Contact your regional distributor
Visit www.nortekcontrol.com for a list of distributors in your region
Copyright © 2015 Nortek Security & Control LLC10005518X11
BYPASS
BUTTON
(SHADED AREA)
RED LED
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,2GIG-DW40-345 - P/N: 10005518 X11 INK: BLACK - MATERIAL: 16 LB. MEAD BOND - SIZE: 6.000" X 8.000" - TOL. +/- 0.125”- SCALE: 1-1 - FOLDING: 4X TO 1.5” x 2” SIDE 2 OF 2
SCREWDRIVER
BATTERY
CONTACT BASE
TAMPER
BUTTON
RED LED
FLASHES
BACK FINGER PRESSING
TAMPER BUTTON
BACK OF CONTACT FRONT OF CONTACT
BACK FINGER PRESSING
TAMPER BUTTON
Table of contents
Other Nortek Accessories manuals
Popular Accessories manuals by other brands

Millefiori
Millefiori Hydro NA-393 quick start guide

Edge Technologies
Edge Technologies SENSA.IO SENSA.TEMP 613-00003 instruction manual

ST
ST X-CUBE-MEMS1 user manual

Mecon
Mecon mag-flux F5 quick start guide

Endress+Hauser
Endress+Hauser OxyMax W COS 71 operating instructions

GSE
GSE 574 Technical reference manual