NORTHERN ELECTRIC NE-500 Instruction Manual

NORTHERN ELECTRIC PRACTICES Filing Instructions: SECTION 502-5101-201
THIS
SECT
ION
REPLACES
SECT
I
ONS
502·510·100CA I
SS.
F,
Issued:
30
November 1973
502.510-121 cA 1ss.
c,
502.515.100 1
ss
.
e,
502.515.121 Standard
ISS
. C 502·515·300 I
SS.
A
WHICH
SHOULD
BE
REMOVED
FRO
M
tHE
BI
NDERS
AND
D
ESTROYED.
FI
LE
THIS
SECTIO
N IN
NUMER
I
CA
L
SEQ
UE
NC
E.
TELEPHONE
SETS
NE-500, NE-1500 (MD), NE-2500
NONBUTTON AND ONE-BUTTON TYPE
IDENTIFICATION, INSTALLATION, AND MAINTENANCE
CONTENTS PAGE CONTENTS (Cont) PAGE
1.
GENERAL 1
C.
Turnbutton
/Pushbutton 25
D. Ringer Capacitor 27
2. DESCRIYI'ION 2
6.
ASSEMBLY
OF
PARTS 27
GENERAL 2 A. Housing (Desk Telephones)
28
COMPONENTS 5 B. Housing (Wall Telephones)
28
C. Ringers
28
A. Mounting Cord 5 D. Dial
28
B. Handset 5 E. Apparatus Blank (Desk Telephones)
29
C. Rotary Dial (NE-500Type) 5
F.
Apparatus Blank
(Wa
ll
Te
lephones)
29
D. DIGITONE* Dial (NE-2500Type) 5 G. Cords (Handset and Mounting)
30
E. Line Switch 5 H. Line Switch Cover Assembly 30
F.
Ringer 5 I. Exclusion Switch 30
G. Network 7 J. Plunger
30
K. Turn
button
and Terminal Strip 31
ORDERING INFORMATION 7
L.
Faceplate (NE-2500 Type
Telephone) 31
FEATURES 7
M.
Designation Window (NE-2500
Type Telephone)
31
3.
IDENTIFICATION 7
1.
GENERAL
GENERAL 7 1.01 This section contains information for the
TELEPHONE SET IDENTIFICA
TI
ON 7 identification, install
at
ion, and maintenance
of
nonbutton
and one-button NE-500, NE-1500
4. INSTALLATION
20
(MD), and NE-2500 type wall and desk telephone
sets.
5.
MA
INTENANCE
20
1.02 The NE-1500 and NE-1554 type telephone
·A. Line Switch Assembly
25
sets are manufacture discontinued (MD) and
B.
E}(cl
usion
or
Monitor Switch
25
are superseded
by
the NE-2500 and NE-2554 type
•A
trademark
of
Northern Electric.
©Northern Electric Company Limited, 1973
PRINTED
IN
CANADA Page 1

SECTION 502-5101-201
telephone sets. The components
of
the NE-1500
(MD)
type telephone sets are compatible with
th
e
NE-2500 type telephone sets except for the dial
and housing.
1.03 An NE-426A electron tube (Fig. 3)
or
a
P0895087 ringer isolator kit (Fig. 4) may
be
installed within the telephone set
to
correct
inductive noise conditions. Refer to the section on
the P0895087 ringer isolator kit for connection
information.
2. DESCRIYfION
GENERAL
2.01 The NE-500 and NE-554 type telephone
sets are equipped with a rotary dial. The
dial may be replaced
in
the field, with an NE-95B
apparatus blank,
if
the telephone set is converted
for manual operation. (Fig. 5 and 6.)
Fig. 1 - NE-25000 Telephone Set
Page
2

SECTION
so2-s101
~
201
r
EXCLUSION
SWITCH
Fig. 2 - NE-2558DRTelephone Set
NE-584 TYPE
2 LINE &
SIGNAL
SWITCH
Page 3

SECTION 502-5101-201
Page 4
Fig. 3 - NE-500 TypeTelephone Set Showing Method
of
Mounting NE-426A Electron Tube
Fig. 4 - NE-500 TypeTelephone
Set
Showing Method
of
Mounting P0895087 Ringer Isolator

2.02
The
NE-1500 (MD) and NE-1554 (MD)
type telephone sets are identical
to
the
NE-500 and NE-554 type except they are equipped
with a 10-button NE-25
type
DIGITONE dial.
2.03
The
NE-2500 and NE-2554 type telephone
sets are similar
to
the NE-500 and NE-554
except they are equipped with an NE-35 type
DIGITONE dial.
COMPONENTS
2.04 All components (except the line switch
plungers on the desk type telephone sets)
are mounted
on
the base
of
the set.
The
line switch
plungers are part
of
the housing assembly.
A.
Mounting Cord
2.05 NE-500, NE-1500 and NE-2500 desk type
telephone sets are provided with a
5-1
/2
foot mounting cord, which may be replaced with a
9-
or
13-foot NE-D type 3-conductor cord,
or
a
13-foot NE-D type 4-, 6-,
10-
or
16-conductor
cord.
The
mounting cord is connected
to
the
service leads through the appropriate connecting
block.
B. Handset
2.06 All sets are shipped with an NE-G3AR
handset. The handset may be replaced with
a handset containing an amplifier, such as the
NE-G6AQ
lA
for customers with impaired hearing,
or
an NE-G7AQ
lA
for customers with impaired
speech. An NE-G8AQ1A handset may be used
in
noisy locations.
C.
Rotary Dial (NE-500
Type
Sets)
2.07 Most NE-500 type telephone sets are
equipped with QDB 1 type dials. The NE-7
(MD) type dial is superseded
by
the QDB 1 type
dial.
The
rotary dial is available with
or
without
the word "OPERATOR" printed on
the
number
plate and must be specified when ordering.
SECTION 502-5101-201
D. DIGITONE Dial (NE-2500
Type
Sets)
2.08 NE-2500 type DIGITONE sets are equipped
with NE-35Q3A1 12-button dials.
The
NE-25 type 10-button dial and NE-35 type
12-button dial are
MD
and are superseded
by
the
NE-35Q type dial.
The
wiring connections for the
NE-35Q type dial differ from the NE-25 type and
NE-35 type dials and circuit modifications must be
performed as detailed in the appropriate section.
The
two additional
buttons
on
the NE-35Q type
dial are designated * and t:t. While operational,
their use is restricted
to
end-to-end signaling.
The
DIGITONE dial is available with
or
without the
word "OPERATOR" printed on the "O"
button
,
and must be ordered accordingly.
2.09
The
NE-35Q type dial assembly contains a
line-powered oscillator, which generates two
frequencies when a
button
is depressed. These
frequencies are transmitted
to
the CO, which must
be
equipped with a converter.
The
converter
accepts the oscillator signals and translates them
into a 2-out-of-5 code for crossbar offices,
or
dial
pulses for step-by-step offices.
E. Line Switch
2.10
The
card-operated line switch uses
bifurcated contact springs
to
improve
reliability. These are protected
by
a plastic cover.
The
line switch is held in the off-hook position
by
a coil spring. The weight
of
the NE-G3AR handset
is sufficient
to
overcome the force
of
the coil
spring, allowing
th
e card to return the line switch
contacts
to
the on-hook position.
F.
Ringer
2.11 Most telephone sets are equipped with
NE-C4A ringers. The ringer volume may be
adjusted for four levels using the four
corresponding positions
of
the volume control,
(Fig. 7 and 8). A fifth position is supplied for
manual ringer cutoff, an installation option.
Page 5

SECTION 502-5101-201
Page 6
Fig. 5 -NE-500
Type
Telephone
Set
Housing Equipped With an
NE-95B Apparatus Blank
LATCH
ASSEMBLY
NE-95B
APPARATUS
BLANK
6-32
x0.
50
MACHINE
SCREW
HOUSING
CATCH
Fig. 6 - NE-554
Type
Telephone Set Housing Equipped With an
NE-95B Apparatus Blank

G. Network
2.12 NE-500, NE-554, NE-2500, and NE-2554
type telephone sets are equipped with an
NE-425QE1network, which contains the necessary
apparatus for automatic line equalization.
In
most
telephone sets all connections
to
the set are made
on the network terminals.
The
NE-425QE1
network provides
five
extra bridging terminals with
no electrical connection to the network circuits.
The
NE-425B
(MD)
or NE-425E
(MD)
networks
are superseded
by
the NE-425QE1 network.
Fig. 7 - NE-500 Type Telephone Set
Base
Showing Date Stamp and Ringer
Volume Control
ORDERING INFORMATION
2.13 When ordering the sets the desired color
must be specified, using the suffixes given in
Table A (e.g.,
to
NE-500CR- add 03 to indicate
black).
FEATURES
2.14
The
features
of
each telephone set are
shown in Tables
B,
C, and D.
SECTION 502-5101-201
TABLEA
TELEPHONE SET COLOR CODES
COLOR
CO
LOR SUFFIX
Black -03
Ivory -50
Green
-51
Red -53
Yellow -56
White -58
Pink -59
Light Beige -60
Light Gray
-61
Blue -62
Turquoise -64
3. IDENTIFICATION
GENERAL
3.01 The code number and assembly date are
stamped on the base
of
each telephone set
(see Fig. 7). Double code. numbers (e.g., NE-500
CID
or
CR/DR) permit field conversion from
rotary dial
to
manual operation .or vice versa,
without changing the code number stamped on the
base
of
the set. The letter R indicates that the
telephone set is equipped with a spring type
retractile handset cord.
The
R - marking has been
discontinued on telephone sets
of
recent
manufacture.
TELEPHONE SET IDENTIFICATION
3.02
NE
-500DR.
The
NE-SOODR
telephone set
is
the basic rotary dial single-line desk set.
The
set components include an NE-G3AR handset, a
QDB 1 type dial, and NE-425QE1 network, a
3-conductor mounting cord and an NE-C4 type
ringer with adjustable volume control. The
NE-SOODR
telephone set is shown in Fig.
9.
Page
7

SECTION 502-5101-201
LINE
SWITCH
COVER
EARS
NE
-
G3AR
HANDSET
i.--RINGER
VOLUME
CONTROL
Fig. 8 - NE-554BR Telephone Set With Housing Removed
Page
8
~
0
I
..
0
.,

SECTION 502-5101-201
Fig. 9 - NE-500DR Telephone Set
3.03 NE-500CR. Thy
NE-SOOCR
telephone
se
t is
identical
to
the
NE-SOODR
telephone set,
except the rotary dial
is
replaced with
an
NE-9SB
apparatus blank and the set is wired for use with
manual telephone systems.
3.04
NE-500DQJ
A.
The
NE-SOODQlA
telephone set
is
identical to the
NE-SOODR
telephone set, except
it
is equipped with a QDB1C
all-number dial.
3.05 NE-500DQJB. The NE-SOODQlB telephone
set
is
identical to the
NE-SOODQ
IA
tel
eph
one set, except
it
has a grounding button.
3.06 NE-500QD.
The
NE-SOOQD
telephone
set
is
identical
to
the
NE-SOODR
telephone set,
except
it
is equipped with an NE-C4Q3A ringer
which has no external volume control.
3.07 NE-500FR.
The
NE-SOOFR
telephone set is
identical
to
the
NE-SOODR
telephone set,
except
it
is equipped with a modifi
ed
line switch
and is wired
to
avoid interference with the dialing
or talking
of
another subscriber on a multiparty
line.
Wh
en
the handset is lifted off-hook, a low-loss
receiver circuit
is
bridged across
th
e line due to
partial operation
of
the line switch.
If
the line is
not
busy, or
if
an incoming call
is
to
be answered,
the left plunger (Fig. 10)
is
pulled up fully to
complete the operation
of
the line switch,
completing the talking and dialing circuit.
Replacing the handset restores
both
the line switch
and monitor switch
to
the unoperated position.
Fig. 10 -NE-500FR Telephone Set Housing
Page 9

SECTION 502-5101-201
3.08 NE-500ER.
The
NE-SOOER
telephone set is
identical
to
the
NE-SOOFR
telephone set,
except the dial is replaced with an NE-9SB
apparatus blank and the set is wired for use with
manual telephone systems.
3.09 NE-500FRN.
The
NE-SOOFRN
telephone
set is identical
to
the
NE-SOOFR
telephone
set, except the instructions between the line switch
plungers are printed in
both
English and French.
3.10 NE-500MR.
The
NE-SOOMR
telephone set
is identical to the
NE-SOODR
telephone set,
except the mounting cord has four conductors.
The
NE
-IAl
, and NE-1A2 Key Telephone System
(KTS) control leads in the mounting cord are
bridged
on
the terminal strip to the line switch
assembly contacts.
The
NE-SOOMR
telephone set
may be rewired for audible ringing
by
using a
separate pair
of
leads.
3.
11
NE-500LR. The
NE-SOOLR
telephone set is
identical
to
the
NE-SOOMR
telephone set,
except the rotary dial is replaced with an N&9SB
apparatus blank and the set is wired for use with
manual telephone systems.
3.12 NE-500SR.
The
NE-SOOSR
telephone set is
identical
to
the
NE-SOODR
telephone set,
except it has additional line switch contacts for A
lead control and a I0-conductor NE-D1
OH
mounting cord for connection
to
a QUSI type
hands-free
unit
, an NE-3 type speakerphone,
and
NE-lAl
KTS, and NE-1A2 KTS.
3.13 NE-500RR.
The
NE-SOORR
telephone set is
identical to the
NE-SOOSR
telephone set,
except the dial is replaced with an NE-9SB
apparatus blank and the set is wired for use with
manual telephone systems.
3.14 NE-500YR.
The
NE-SOOYR
telephone set is
identical
to
the
NE-SOODR
telephone set,
except
it
is equipped with a lamp which provides a
message-waiting feature.
The
visual signal
indication from the
COO
11S13 neon lamp which
protrudes through the housing into an amber cap,
is
controlled
by
the attendant
at
the
message-waiting cabinet. General application
of
Page 10
this telephone and its feature are in hotel/motel
installations.
The
transmission, ringing, dialing and
message-waiting indication circuits for the
NE-SOOYR
telephone set can be energized through
a common pair
of
wires.
3.15 NE-500WR.
The
NE-SOOWR
telephone set
is identical
to
the
NE-SOOYR
telephone set,
except the rotary dial
is
replaced with an NE-9SB
apparatus blank and the set
is
wired for use with
manual telephone systems.
3.16
NE-500YQJA.
Th
e NE-SOOYQlA
telephone set
is
identical
to
the
NE-SOOYR
telephone set, except
it
has an MD2993
pushbutton which, when depressed, may be used
for signaling.
3.17 NE-500YQB. The
NE-SOOYQB
telephone
set is identical to the
NE-SOOYR
telephone
set, except
it
is
supplied with a QDB 1C all-number
dial.
3.18 NE-500PRN.
The
NE-SOOPRN
telephone
set is identical
to
the
NE-SOOYR
telephone
set, except the message-waiting lamp is powered
by
24
V de. Power is supplied on a separate pair
of
leads, independent from the common pair
of
conductors serving the transmission, dialing, and
ringing circu
it
s.
3.19 NE-500NRN.
The
NE-SOONRN
telephone
set is identical to
the
NE-SOOPRN
telephone
set, except the rotary dial is replaced with an
NE-9SB apparatus blank and the set is wired for
use with manual telephone systems.
3.20 NE-501
CR,
DR, ER, and FR.
The
NE-SOlCR, DR, ER, and
FR
telephone sets
are identical
to
the
NE-SOOCR,
DR, ER, and
FR
telephone sets respectively, except an NE-426A
electron tube is supplied
to
permit selective
ringing.
3.21 NE-502BR.
The
NE-502BR telephone set is
identical
to
the
NE-SOODR
telephone set,
except
it
provides an exclusion feature.
The
exclusion switch assembly
is
activated by lifting
the left line switch plunger
of
the telephone set. To

restore the excluded service
to
normal, the plunger
is restored
to
its normal position
or
the handset is
placed on-hook.
The
NE-D6AA mounting cord
contains sufficient leads
to
permit connection
to
either NE-lA1
or
NE-1A2 KTS or the exclusion
circuit.
The
NE-502BR-6l telephone set is supplied
with an NE-D6AA-61 cord and can be modified for
use with data sets.
3.22
NE-502AR.
The
NE-502AR telephone set is
identical
to
the NE-502BN telephone set,
except the dial is replaced with an NE-95B
apparatus blank and the set is wired for use with
manual telephone systems.
3.23 NE-502QA.
The
NE-502QA telephone set
(Fig. 11) is identical
to
the NE-502BR
telephone set, except
it
is equipped with an
MD2993 pushbutton which, when depressed, may
be used for signaling.
3.24 NE-51OBR. The NE-5 IOBR telephone set is
identical
to
the NE-500DR telephone set,
except
it
has two separate lines which are selected
by
a turnbutton-pushbutton. Depressing the
SECTION 502-5101-201
button
provides momentary connection between
two contacts for signaling. To permit incoming-call
audible signaling
on
both
lines, an external ringer
may be connected to the second line.
The
turnbutton can also serve as a transfer
or
cutoff
key on lines, line extensions, ringers, etc. The
features extend
to
the connecting block through
the NE-D6AA mounting cord, which is connected
to
the terminal strip within the telephone set.
3.25
NE-510AR.
The NE-510AR telephone set is
identical to the NE-51
OBR
telephone set,
except the dial is replaced
by
an NE-95B apparatus
blank and the set is wired for use with manual
telephone systems.
3.26 NE-51OFR.
The
NE-51
OFR
telephone set is
identical
to
the NE-51
OBR
telephone set,
except the NE-51
OFR
is equipped with a
lift-to-talk- and-dial plunger as described for the
NE-500FR telephone set. (See 3.07
.)
3.27 NE-51
OER.
The
NE-51
OER
telephone set
is
identical
to
the NE-51
OFR
telephone set,
except the rotary dial is replaced with an NE-95B
Fig.
11
-NE-502QA Telephone Set
Page
11

SECTION 502-5101-201
apparatus blank and the set
is
wired for use with
manual telephone systems.
3.28 NE-510QA.
The
NE-51
OQA
telephone set is
identical
to
the
NE-5 1OFR telephone set,
except
it
is
provided with an MD2993 pushbutton
which provides the features described
for
the
NE-502QA telephone set. (See 3.23.)
3.29 NE-51
lDR.
The
NE-51
lDR
telephone set is
identical
to
the NE-5 1
OBR
telephone set
(see 3.24), except
it
is
equipped with an
exclusion-switch assembly which is activated by
lifting the
left
line switch plunger.
The
NE-D 16QA
mounting cord extends the control leads from the
terminal strip and network
to
facilitate connection
to
the QUS1 type hands-free unit,
the
NE-3 type
speakerphone,
NE-IAl
KTS, NE-1A2 KTS and
exclusion circuits.
The
NE-51
IDR
telephone set
may
also be used with
data
sets.
3.30
NE
-511CR.
The
NE-51 ICR telephone set
is
identical
to
the
NE-51
IDR
telephone set,
except
the
rotary
dial
is
replaced with an NE-95B
apparatus blank and
the
set is wired
for
use
with
manual telephone systems.
3.31 NE-511DQA.
The
NE-51 lDQA telephone
set
is
identical
to
the NE-51
lDR
telephone
set except
it
uses a QDBID all-number dial.
3.32 NE-2500D.
The
NE-25000 telephone set
is
identical
to
the
NE-SOODR
telephone set,
except
it
has a DIGITONE dial. All components,
except the housing, faceplate, dial, and dial
bracket, are interchangeable between the
NE-SOOD
and
NE-25000
telephone sets.
The
NE-25000
is
shown in Fig.
1.
3.33
NE-2500MQA.
The
NE-2500MQA
telephone set is identical
to
the NE-25000
telephone set, except for
the
NE-D4BJ
4-conductor cord which permits connection to
either an NE-IA1
or
NE-1A2 KTS.
The
NE-2500MQA telephone set may
be
modified
on
the terminal strip within the1set to obtain audible
signaling
on
a separate pair
of
_leads.
Page
12
3.34 NE-2500SQA.
The
NE-2500SQA telephone
set is identical
to
the
NE-25000 telephone
set, except for additonal line switch contacts and a
10-conductor NE-D 1
OH
cord necessary for
connection to the QUS 1 type hands-free unit, the
NE-3
type
speakerphone
or
NE-lAl,
and NE-1A2
KTS.
3.35
NE-2500
YQA.
The
NE-2500YQA
telephone set
is
identical to the NE-25000
telephone set, except for the message-waiting lamp
on
the
face
of
the
set.
The
features and their
operation are identical to those described for
the
NE-SOOYR
telephone set for rotary dial systems.
(See 3.14.)
3.36
NE
-
2511
DQA.
The
NE-251 lDQA
telephone set
is
similar in appearance
to
the
NE-25000 telephone
·set.
The
NE-251 IDQA
telephone set is equipped with an NE-584AQA key
(turnbutton-pushbutton) and an exclusion switch
to
provide the features as described
for
the
NE-5 1
lDR
telephone set. (See 3.29.)
3.37 NE-554BR.
The
NE-554BR telephone set is
a single-line wall telephone set. (Fig. 12.)
The
set components include an NE-63AR handset,
a QDB 1 type dial, an NE-425QE1 network, and an
NE-C4 type ringer with adjustable volume control.
3.38 NE-554AR.
The
NE-554AR telephone set
is
identical to the NE-554BR telephone set,
except
the
dial is replaced with an NE-95B
apparatus blank, (Fig. 6), and the set
is
wired for
manual service.
3.39 NE-593BRW.
The
NE-593BRW telephone
set is identical to
the
NE-554BR telephone
set, except
it
is
not
equipped with a ringer.
3.40 NE-503ARW.
The
NE-593ARW telephone
set is identical
to
the
NE-554BR telephone
set, except
it
is
not
equipped
with
either a ringer
or
a dial.
The
dial is replaced
by
an NE-95B apparatus
blank and the set
is
wired for manual service.

SECTION 502-5101-201
Fig. 12 - NE-554
Type
Wall Telephone Set
Page
13

SECTION 502-5101-201
3.41 NE-554QD. The NE-554QD telephone
se
t
is
identical
to
th
e NE-554BR telephone set,
except it is
not
equipped with
an
external ringer
volume control.
3.42 NE-554FRN. The NE-554FRN telephone
set is identical to
th
e
NE-5
54BR telephone
set, except
it
is equipped with a modified line
switch and is wired
to
avoid interference with the
dialing
or
talking
of
another subscr
ib
er on a party
line. When the handset is lifted, a low-lo
ss
receiver
circuit
is
bridged across
th
e line due
to
partial
operation
of
the line switch.
If
the line is
not
busy,
or
if
an incoming ca
ll
is
to
be answered, pushing
in
the monitor switch (located on the right side of the
set), fully operates the line switch, completing
the
talking and dialing circuit. Replacing the handset
restores
both
the line switch and monitor switch.
3.43
NE
-556FRN
(M
D).
Th
e NE-556FRN (
MD)
telephone set
is
identical
to th
e
NE-554FRN telephone set, except it has an
NE-426A electron tube, and is intended for 4-party
se
lective and 8-party semiselective (polarized
ringing line) service.
3.44 NE-554BQA. The NE-554BQA telephone
set is identical
to
the
NE-5
54BR telephone
set, except it has a
QDB
IC all-number dial, and a
P096C252 signal switch located below and
to
the
right
of
the dial. The signal switch leads are
connected
to
a P338886 terminal strip located on
th
e dial bracket.
3.45 NE-55JBQJA. The NE-554BQ1A telephone
se
t is identical
to
the NE-554BR telephone
set, except it has a
QDB
1C all-number dial.
3.46 NE-55JQ4A. The NE-554Q4A telephone
set is identical
to
the NE-554BR telephone
set, except it has a ground switch located below
and
to
the right
of
the dial.
Th
e ground switch is
wired b
et
ween tip and ground. Depre
ss
ing the
switch
button
connects one side
of
the
li
ne
to
ground.
3.47 NE-558DR. The NE-558DR telephone set is
the standard 2-line set.
It
is equipped with
standard components, except the dial is a
QDB
lB
dial with an additional set
of
contacts, which mute
Pa
ge 14
the di
al
pulses for u
se
in speakerphone systems. In
ad
dition, the NE-558DR telephone set is equipped
with
an
exclusion switch and an NE-584B
turnbutton-pushbutton. Holes are provided in
th
e
baseplate for mounting an NE-659A transmitter
for u
se
in home communication systems.
Th
e
exclusion switch and turnbutton-pushbutton
provide the following services:
(a) The exclusion switch provides a means
of
disconnecting
an
extension station by raising
the plunger projecting through the
top
of
the
housing. The switch returns to normal when
th
e
handset
is
replaced.
(b)
In
home communications systems, the
exclusion switch may be used
to
place the
CO
line on hold while using the intercom.
(
c)
Th
e turnbutton-pushbutton provides a
means
of
transferring the talking circuit to
either
of
two lines. This
swi
tch can also be used
to
cut
off
or
transfer lines, extension stations,
ringers, etc. Depressing the button momentarily
closes a pair of contacts
to
provide signali
ng.
3.48 NE-558CR.
Th
e NE-558CR telephone set is
identical
to
the NE-558DR telephone set,
except the dial is replaced with an NE-95B
apparatus blank, and
th
e set
is
wired for manual
service.
3.49 NE-558DQA. The NE-558DQA telephone
se
t is identical
to
the NE-558DR telephone
set, except
it
has a
QDB
1D all-number dial.
3.50
NE-2554B
QJ
A. The NE-2554BQ1A
telephone set is the standard single-line
DIGITONE wall set.
It
is
identical to the
NE-554BR telephone set, except it
is
equipped
with an NE-35Q3A (MD) or NE-35Q3A1
DIGITONE dial. Left and right dial-mounting
adapters are required
to
mount the dial.
3.51 NE-2558DR.
Th
e NE-2558DR telephone
set
is
the standard 2-line DIGITONE wall
set, (Fig. 2).
It
is identical
to
th
e NE-558DR
telephone set except it is equipped with an
NE-35Q3G (MD)
or
NE-35Q3Al DIGITONE dial,
and a P096C204 2-line
sw
itch, which a
ll
ows
th
e A
lead to be
sw
itched when changing lines. .

TEL
E
PHO
NE
SET
DIAL
ELEC.
ALL
TUBE
NUMBER
MAN
U
AL
ROTARY
DIGITONE
NUMBER
4·PARTY
KEY
SPEAKER·
LIFT-TO·
OF
LINES
SI
G
NALING
CALLING
SEL
.
RING
SYSTEMS
PHONE
TALK
PI
C
KED
UP
C
IR
C
UIT
NE-501C'
R
-•
NE·501DR·*
...;
I
NE-501
ER
·*
NE-50
1
FR·*
...;
...;
I
NE-502AR·*
NE·502BR·*
...;
I
NE·502AR·*
NE-502
B
R·*
...;
I
NE-502
Q
A·*
I
NE-510A
R
·*
NE-510BR·*
2
NE-510A
R
·*
NE-510B
R
-•
I
...;
NE-510A
R
·*
NE·5
10
BR
-•
I
...;
NE-510AR·*
NE·5
10
BR
-• I
.
NE-510A
R
·*
NE-5
1
0BR·*
I
NE-510E
R·•
NE-510FR·*
2
...;
NE·5
1
0E
R
·*
NE-5
1
0FR·*
2
NE·5
1
0E
R
-•
NE·5
1
0FR·*
I
...;
NE·5
1
0E
R
-•
NE-510
FR
·*
I
...;
NE-510QA·*
I
NE-51
I
CR·*
NE-51
ID
R·*
NE-2511
DQA·*
\
...; ...;
2
...;
NE-5
1
ICR·*
NE·5
1
ID
R·*
NE
-
25
11
DQA·*
...; ...;
2
...;
NE-51
IC
R
·*
NE-5
1IDR
·*
NE-25
11
DQA·*
...; ...;
2
...;
NE-51
lCR·*
NE
-
51
lD
(l·
*
NE
-
25
11
DQA·*
...;
...;
I
...;
NE
-
51
lCR·*
NE-51
lD
R
·*
NE-25
11
DQA·*
...;
...;
1
...;
NE-51
lCR·*
NE-5
1
ID
R
·*
NE·2511
DQA·*
...;
...;
I
...;
NE·5110QA·*
...;
...;
...;
I
...;
• W
hen
o
r
de
r
in~
t
he
t
elephone
set
the
desi
r
ed
co
lor
mus
t
be
specifie
d
using
t
he
su
ffixes
inT
ab
leA.
.
RINGER
OR
COMMON
OR
BUZZER
LINE
PRJV
ATE
LINE
EX
C
LUSION
CUTOFF
RINGER
RINGER
OR
BUZZER
BYEXCL
.
I
...;
...;
...;
...;
...;
...;
...;
...;
...;
...;
I
...;
...;
...;
...;
...;
...;
...;
v
...;
...;
...;
...;
...;
...;
...; ...;
...;
...;
I
~
SECTION
502-5101-201
TABLED
ONE-BUTTON
DESK
TELEPHONE
SET
FEATURES
(Double-Line
or
Additional
Equipment)
CUT
OFF
BY
KEY
RINGER
OR
EXTENSION
QBB1A
BUZZER
STATION
AUXILIARY
CONN
. G
ROUND
INSET
OR
R
INGER
RE
C
EIVER
BLK
.
BUTTON
...;
...;
...;
...;
...;
...;
...;
...;
...;
...;
...;
...;
...;

-
-..J
TELE
PHO
NE SET CODE
ROTARY DIGITONE
MANUAL
NE-SOODR-*
NE-25000-* NE-
SOOCR
-*
NE-SOODQIA-*
NE-SOODQ
I
B-*
NE-SOOFR-*
NE-SOOER-*
NE-SOOFRN-*
NE-SOOMR-*
NE-2500MQA-*
NE-SOOLR-*
NE-
SOOQD-*
NE-SOOSR-*
NE-2500SQA-*
NE-SOORR-*
NE-SOOYR-*
NE
-2500YQA-*
NE
-S
OOWR-*
NE-SOOYQ
IA
-*
NE-SOOYQB
-*
NE
-
SOOPRN-*
NE-SOON
RN-*
TABLEC
NONB
UTTON
DESK
TELEPHONE
SET
FEATURES
(Single-Line)
DIAL LIFT
-T
O-TALK
MARKING
AL
PH
A-
ENGLISH
KEY
SPEAKER-
NUMERIC NUMERIC
ENG
LISH
AND
SYSTEM
PHO
NE
FRENCH
v
v
v v v
v v
v v
v v v v
v
v
v v
v v
•
When
ordering the telephone set the desired color musl
be
specified using
1lw
suffixes
in
Table
A.
Notes:
MESSAGE
G
ROUND
WAIT
I
NG
BUTTON
v
v
v v
v
I.
Equipped with
NE-C4Q3A
ringer and no external
vo
lu
me
<:Ontrol.
3. For Hotel
~4
V
<l<:
Syslcm mcssagt·-wailing
lam
p dn:uil.
2.
Not equipped with a Ringer. 4. Equipped with neon lamp for message-wailing.
QBBIA
CONN.
BLK
.
v
v
v
v
SEE
NOTE
I
4
2.4
4
3
3
{ll
Q
~
Vl
0
N
Vi
-
0
-
~
-

-
00
TEL
E
PHO
NE
SET
DIAL
MANUAL ROTARY DIGITONE
NE-554AR-* NE-554BR
-•
NE-2554
BQ
IA-*
NE-593
ARW
-*
NE-593BRW-•
NE-554FRN-•
NE-55
4B
QA-*
NE
-5
5
4BQ
IA
-*
NE
-55
4Q4A
-*
N
E-
558CR-* NE-558DR
-*
NE-2558DR-*
NE-558DQA-*
NE-556FRN-•
NE-155
4B
-*
NE-554QD
-*
TABLED
NONBUTTON
AND
ONE-BUTTON
WALL
TELEPHONE
SET
FEATURES
ELECTRON
ALL TUBE NUMBER
NUMB
ER 4-PARTY LIFT-TO-TALK
OF
LINES
DIAL SEL. RI
NG
PICKED
UP
I
I
.J
I
.J
I
.J
I
I
2
.J
2
.J
.J
I
I
I
•
Whe
n ordering t
he
telephone set the des
ir
ed col
or
must be specified using the suf
fi
xes
in
Table
A.
t No Ringer volume control.
SI
GN
A
LI
NG
LINE
CI
RCU
IT RINGER
.J
.J
.J
.J
.J
.J
.J
.J
.J
.J
.J
t
GROUND
EXCLUSION BUTTON
.J
.J
.J
Cll
m
~
0
2!
VI
0
N
I
VI
-
0
-
~
-

0
~
n 0
[J
0 0
0
© ( ) ©
0 0
0 0
08
<=:) 9
~@
0
o~
Fig. 13 -Present Production Baseplate (Wall Telephone)
t
I
-
CE
NTRE LINE
OF
BASE
PLATE
r-:1
1
~
I "
:;
I~
l.1
;
sJ~z:
I
IN
. 1
....
-
A-
-_'.__L -
--
-y-
L+ 14::-11/
SI
N.-j
~14-----'-3
5/
161N.---+j
I
I
cp
Fig. 14 -Early Production Baseplate (Wall
Te
lephone)
Showing Drilling Location for Mounting Holes
SECTION 502-5101-201
Page 19

SECTION 502-5101-201
4. INSTALLATION
4.01 The telephone sets shall be installed
according to the appropriate sections.
Connection information for each type
of
telephone
set is located
in
the section entitled,TELEPHONE
SETS -TYPE CONNECTIONS.
4.02 Several holes are provided
in
the baseplate
of
the wall telephone set to allow greater
flexibility
in
mounting and to minimize the
use
of
a backboard (Fig. 13). Baseplates
of
current
manufacture may
be
mounted on a conduit outlet
box. Baseplates
of
early production models require
modification.
4.03
To
modify early production baseplates, drill
two holes as shown
in
Fig. 14 using a No.
17
(0.173 inch) drill bit.
If
a conduit outlet box
is
not
available, mount the telephone set with screw
anchors, using the mounting holes
at
the top and
bottom
of
the baseplate.
4.04 Refer to the appropriate section for
information on screw anchors suitable for
mounting wall telephone sets.
4.05
When
connecting a telephone set
to
an
NE-lA,
NE-lAl,
NE-
1A
2, or NE-6A
KTS
, a
QUSl-type hands-free unit
or
an
NE-3
type
speakerphone, refer
to
the connection section on
the particular telephone set being installed.
Page
20
5. MAINTENANCE
5.01 Maintenance
of
the telephone sets consists
of
cleaning exterior surfaces, burnishing and
adjusting switch contacts, a
nd
replacing defective
components.
5.02 Housing, handset and dial pushbuttons can
be cleaned with a soft cloth moistened with
water.
Do
not
use scouring powders or
cleaners.
Replace plastic components
if
cleaning does not
have
satisfactory results.
5.03 Check line and ground terminations, and
wire dressing before proceeding with
maintenance.
5.04
CO
station ringer and dial test circuits
should
be
used where possible when
checking telephone sets.
5.05 Network and line switch assemblies are
riveted to
th
e baseplate. These assemblies
are
not
normally replaced
in
the field, however,
they
can
be replaced by drilling
out
the rivet and
using a No. 4
by
0.250 (P0970700) self- tapping
screw.
5.06 Chart l lists common troubles and their
probable causes, with suggested corrective
actions.

SECTION 502-5101-201
CHART 1 - FAULT LOCATION GUIDE
INDICATION PROBABLE CAUSE CORRECTIVE MEASURE
Ring
er
disconnected
or
in- Connect correctly. Refer to
correctly wired in set. appropriate connection section.
Volume control wheel in cut- Move control wheel
to
ring
off
position. position and advise customer
of
cutoff
position.
Open winding. R
ep
la
ce
ringer.
Metal
part
icles in armature Remove with adhes
iv
e tape
or
Bell does
not
ring. gap. approved equivalent.
Open tube. Short-circuit yellow and black
tube lead
s.
If
ringer operates
when ringing voltage
of
correct
polarity is applied, r
ep
lace
tube.
Op
en ringing capacitor. Repla
ce
telephone set,
or
bridge A&K terminals
of
the
NE-425QE1 Network with a
QCCl2A capacitor.
Bell
too
loud. Volume control wheel in
Move
control wheel
to
softer
wrong position. position and advise customer
on
proper use.
Volume control wheel in Move control wheel
to
louder
wrong position. position and advi
se
customer
on proper use.
Bell
too
sof
t. Set
on
sound-absorbent Mount set
on
hard
su
rface.
material.
Cord touching gong. Dress cord properly.
Page
21
Other manuals for NE-500
1
This manual suits for next models
3
Table of contents
Other NORTHERN ELECTRIC Telephone manuals