Tools required:
• 1/8” allen wrench (included) • Power drill and set of drill bits
• Flat blade screwdriver (potentiometer & terminal size) • Center punch
• Screwdriver (Phillips size 2) • Wire stripper
• Tape ruler • #7 drill 1/4-20 tap (metal frame install)
• servicing or cleaning.
• To reduce the risk of injury or person, use the operator only with
Pedestrian Swing doors.
• This operator is for indoor use only.
Always disconnect the main power to the operator prior to • circuit from the main circuit breaker panel and must NOT be
connected into any building lighting system that operates
flourescent lights.
• Maximum door size: 48 in (1219mm) wide x 250 lb (113.4kg).
120VAC power supplied to the operator must be a dedicated
WARNINGS
!
®
5700 LEO
Power Operator
Installation and Instruction Manual
Series
ASSAABLOY
80-9357-0008-020 (Rev 3)
Item No. Description
1 Back plate
2 Door Closer (1601LAP or 1601BFLAP)
3 Motor Assembly (5700M)
4 Inverter (5700IN)
5 Cover (5700CVR)
6 On/Off switch
7 Circuit Breaker
8 120VAC Electrical Connections
9 Activation Inputs
10 Door Open/Closed Position Magnets
11 Optional RF Receiver
12 Power Supply - 1.1A 24V
Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)

Page 2
Hollow Metal Door Frame Reinforcing
Frame
Material
12 Ga.
.1046 (2.66)
14 Ga.
.0747 (1.90)
16 Ga.
.0598 (1.52)
18 Ga.
.0478 (1.21)
12 Ga.
.1046 (2.66)
10 Ga.
.1343 (3.41)
10 Ga.
.1343 (3.41)
8 Ga.
.1644 (4.18)
18 Ga.
.0478 (1.21)
12 Ga.
.1046 (2.66)
12 Ga.
.1046 (2.66)
10 Ga.
.1343 (3.41)
Reinforcing
Recommended Min. Required
Contents
General Information
• the 120VAC (60Hz) power input to the LEO door operator be
supplied through normally closed alarm contacts of the alarm
system / alarm panel.
• Power input to LEO door operator must be 120VAC (60Hz) to
terminals HOT and COM at terminal strip T1. Earth ground
(GND) to green screw on backplate.
• All wiring must conform to standard wiring practice in
accordance with national and local wiring codes.
• Note:Unless otherwise noted, all dimensions are given in
inches (millimeters).
• Minimum suggested and required material thickness for
hollow metal frames (skin plus reinforcement) is charted on
below.
• Unit is Non-Handed.
• Door must be hung on butt hinges [5” (127mm) max. width] or
3/4” (19mm) offset pivots. A separate door and frame
preparation template will be supplied for other conditions.
• Door must swing freely through the entire opening and
closing cycle before beginning the installation.
• Use of an auxiliary door stop (by others) is always
recommended.
• An incorrectly installed or improperly adjusted door operator
can cause property damage or personal injury.These
instructions should be followed to avoid the possibility of
misapplication or misadjustment.
UL labeled fire or smoke barrier door assemblies require that WARNING: Make sure 120VAC (60Hz) input power is turned
off at facility’s main circuit breaker before proceeding with
installation.
GeneralTemplating Information:
• Before beginning the installation, verify that the door frame is
properly reinforced and is well anchored in the wall.
• Unreinforced hollow metal frames and aluminum frames
should be prepared and fitted with 1/4-20 blind rivet nuts,
furnished by others.
• Concealed electrical conduit and concealed switch or sensor
wires should be pulled to the frame before proceeding.
Fasteners for Frame:
• 1/4-20 machine screws for hollow metal and aluminum.
• No. 14 x 2-3/4” (70mm) long sheet metal screws for wood.
Fasteners for Door:
• 1/4-20 machine screws.
• 3/8” diameter x 1-5/8” (41mm) long sex nut.
Electrical Information:
• Maximum current draw of unit is 0.6 amps.
• Breaker Switch protects the motor assembly and inverter;
and has a 3 amp rating.
• Maximum wire size is:
12AWG at terminals HOT and COM (120VAC; 60Hz) on
“T1” Power Input Terminal.
14AWG at terminals 1 thru 4 on Accessory Terminal .
18AWG at terminals 22 thru 25 on “T1” Power Input
Terminal.
Frame Reinforcement Table
General 2
Frame Reinforcement Table / Technical Data 2
Component Layout 3
ADA / ANSI / UL 3
Hinge (Pull) Side Mounting 4
Stop (Push) Side Mounting 6
Adjust Power and Opening / Closing Cycle 5 / 7
Input Power Configuration 8
Final Setup 8
Inverter Details 9
Accessory / Typical Installations 10
Troubleshooting 10
RF Receiver User’s Guide 12
Hinge (Pull) Side Template 14
Stop (Push) Side Template 15
Technical Data
120VAC, 60Hz
.6 amps
24V DC, max. 1.1 Amp.
28 - 48" (71-122 cm)
100-250 lb. (45-113 kg)
Input power:
Power consumption:
Power supply:
Door width:
Door weight:
Door opening angle:
Hold open time: 5 - 30 seconds (A.D.A. 5 seconds min.)
3 amps
Circuit breaker:
up to 110° Pull side; up to 170 Push side;
Manually to 180° Push/Pull side
°
ASSAABLOY
Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)

BACKPLATE
REED SWITCH
CHAIN OPEN / CLOSE
POSITIONING
MAGNETS
“T1” POWER INPUT
TERMINAL (3-POSITION)
ACCESSORY
TERMINAL
(4-POSITION)
PINION EXTENSION /
CLUTCH ASSEMBLY
INVERTER
MOTOR ASSEMBLY
POWER SWITCH
BREAKER SWITCH
1600 SERIES
CLOSER BODY
CONNECTING LINK
BUSHING ASSEMBLY
SHOE
SHOE / ADJUSTING
ROD ASSEMBLY
FOREARM
SCREW
MAIN ARM
ADJUSTING
TUBE
MAIN ARM / SLIDE
UNIT ASSEMBLY
Included with 5710 and 5740 Included with 5730 and 5740
Component Layout
ADA / ANSI / UL Information
AmericansWithDisabilitiesAct(A.D.A.)
Thesedoor operatorscanbeinstalledandadjusted to conformwith
A.D.A.regulations.
ANSIStandards
ANSI A117.1 – These door operators permit door
assemblies to conform to the requirements of this
specification "for buildings and facilities – providing
accessibility and usability for physically
handicappedpeople".
• ANSI A156.19 – These products are designed to conform to this
specification "for power assist and low energy power
operateddoors".
– "PAS" Function is designed to meet or exceed all of the
requirementsforthe"PowerAssistDoor".
– "POR" Function is designed to meet or exceed all of the
requirementsforthe"LowEnergyPowerOperatedDoor".
U.L.Listing
Underwriters Laboratories,Inc.listed for use on
fire and smoke barrier door assemblies when the
120VAC (60Hz) power input is supplied through
the normally closed alarm contacts of a
compatible UL Listed alarm system or alarm
panel.
ASSAABLOY
SLIDE TRACK
ASSEMBLY
SLIDER
BUFFER STOP
9/64” HEX
DRIVE SOCKET
SCREW
SLIDE ARM
TUBE SLIDE ARM
ROD
Page 3
Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)

Note: Door must be visible by person
operating activation switch(es)
Door Opening
Angle Dim“A”
Up to 110°
111° to 180° 15-1/2 (394)
13-1/4 (337)
Notes:
• All dimensions are given in inches (mm).
• Thickness recommended for reinforcements in hollow
metal doors and frames is charted on Page 2.
• Do not scale drawing.
• Right hand door shown.
• This template information based upon use of 5"
(127mm) maximum width butt hinges. A separate
template is required for other conditions.
• Maximum frame reveal is 6-7/8” (175mm) for this
application.
• Conduit hole nearest the hinge is suggested for 120
VAC power input.
2”(51mm)
Min.
Frame Face
1-1/8”
(29)
1-1/4
(32) 1-7/16
(37)
11
(279) 22
(559)
7-9/16
(192)
13-7/16
(341)
1-1/8
(29)
C
LHinge
1/4-20 Machine Screws
or No. 14 Wood Screws
(6 Places)
7/8 (23) Dia.
(2 Places)
3/8 Dia.
Sex Nuts
(3 Places)
Frame
Rabbet
Frame
Stop/Soffit
3
(76)
13-13/16
(350)
1/2
(13)
A
11-11/16
(297)
6”
(152mm)
Min.
Clearance
14-3/16
(360)
12-15/16
(329) 13-13/16
(351)
Right Hand Door
opening to 110° shown.
5/8
(15.9) Stop
1. Hinge (Pull) Side Mounting Instructions
Step1: Determine hand of door from illustration on upper right of this
page.
Step2: Using templateabove locateandprepare holes in the frame&
door:
Frame
A. Prepare six (6) holes for 1/4-20 machine screws or
No.14 x 2-3/4" (70mm) wood screws.Blind rivet nuts (by others)
are suggested for unreinforced hollow metal frames or for
aluminumframes.
B. Concealed Wired Units Only: Two (2) 7/8" (22mm) diameter
holesforconduit,forpowerinputandforswitch/sensorwires.
NOTE: On new construction these holes will generally be drilled
by the frame supplier at their shop or at the time the frame is
installedinthewall.
Door
C. Prepare three (3) holes for 3/8" diameter sex nuts.Standard units
aresuppliedwithsexnutsandscrewsfor1-3/4"(44mm)thickdoor.
Sex nuts and screws for other door thicknesses are available to
order.
Step3: Removecoverfromtheunitandsetcover&coverscrewsaside.
Step4: Mountunittodoorframe. SelectAorBbelow.
A. Concealed Wired Units Only:
B. Surface Wired Units Only:
(Continue to next page.)
Connect conduit to frame side of
backplate. Fastenunittodoorframe(sevenscrews).
Fasten unit to door frame (seven
screws). Mount conduit bracket (found in screw pack) to unit’s
backplate with two screws provided. Connect wiring conduit to
bracket.
1A. Installation Sequence
Left
Hand
Door
Right
Hand
Door
2”(51mm)
Min. Frame
Face Frame Reveal
Door
6”(152mm)
Min. Ceiling
Clearance
1-3/4”(44mm) Min.
2-1/4”(57mm) Max.
DoorThickness
Please verify desired mounting
requires Hinge (Pull) Side
application as shown on this
template.
Page 4
ASSAABLOY
Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)

1A. Installation Sequence Continued
Step5: Mounttrackassemblytodoorusing31/4-20screws&sexnuts
with buffer assembly toward hinge. Open part of track to face
topofdoor.
Step 6: Insert slide arm rod into slide arm tube setting the distance
between the pinion square and the slide stud at 13-1/2”(343).
Install 9/64” hex drive socket head screw from screw pack.
(Seeillustrationbelow)
Step 7: Using an adjustable wrench, rotate pinion 45° toward hinge,
as shown below. With the arm assembly parallel to the
door, secure arm to pinion when square of the pinion aligns
with the square in the arm. Secure with countersunk
washer and 1/4-20 Flat Head Screw (with thread lock)
provided. Tighten screw with 7/16” wrench or socket.
Step 9: to
increase door closing power. Door control is shipped set at
midpoint of power setting.Maximum closing power can be
achieved with 8 (360°) clockwise turns of the power
adjustment screw.
Step 8: Insert arm stud into slide block in track assembly. Secure by
pushing in on the retainer clip that extends from the slide
block in the track, until it is flush with the slide block (see
illustration below).
Adjust closing power of unit (See Fig.1) - Using a 1/8” allen
wrench, turn the power adjustment shaft clockwise
Step 10:Adjust Hydraulic valves using a 1/8” hex wrench to obtain
proper door closing speeds. See following illustrations. Refer
to Table 1 below for recommended minimum opening /
closing times per ANSI/BHMA A156.19.
Note: A.D.A. requires that from an open position of 70°, the
door will take at least 3 seconds to move to a point 3”(75mm)
from the latched position,measured at the leading edge of
the door.
Closing Cycle – Make adjustments, as necessary, to the Sweep
Speed "S" valve and Latch Speed "L" valve. See Fig. 2 below for
location of valves.Turn valves clockwise to reduce speed, counter
clockwise to increase speed.
Opening Cycle – Adjust Backcheck, "B" valve, as necessary, for
hydraulic resistance to door opening in the backcheck range. See
illustration in Fig.2 for location of valve.
NOTE:Too much Backcheck, "B" valve, can affect the
operation of the units pump, preventing units from fully
opening the door.This valve may require fine tuning after all
other adjustments have been made.
2
1
Attaching Arm Stud to Slide
Retainer Clip
1/8"
Hex
Key
Slower
Closing
Faster
Closing
Closing Cycle
Closed
10°
e
g
n
a
R
h
c
t
a
L
e
g
n
a
R
p
e
e
w
S
1/8"
Hex
Key
Increase
Cushion
Decrease
Cushion
Sweep Valve
Latch Valve
Backcheck
Valve
Figure 2
Power Adjustment
1/8"
Hex
Key
Increase
Power
Decrease
Power Figure 1
Opening Cycle
B
a
c
k
c
h
e
c
k
g
n
i
n
e
p
O
13-1/2
(343)
Note: Center threaded hole of slider arm should align
with seventh hole of the slider tube.Stud in slider
arm should point to same side as holes in slider
tube (see illustration on Page 3).
RH
Door LH
Door
Rotate
Pinion
Pinion Flats
1A. Installation Sequence Continued
Table 1 - Minimum Opening / ClosingTimes for ANSI/BHMA A156.19
Door Weight in Pounds (kg)
Door Leaf
Width -
Inches (mm)
Matrix values are in seconds.
Backcheck - adjust the backcheck valve to have a minimum
opening time to backcheck or 80 degrees (whichever comes
first) based on Table 1.
Closing Time - adjust Latch and Sweep valves to have a
minimum closing time from 90 degrees to Latch Check or
10 degrees (whichever comes first) based on Table 1.
Page 5
ASSAABLOY
Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)

Door Opening
Angle Dim“A” Dim“B”
Up to 110°
111° to 170° 12 (305)
9-1/2 (241) 13-1/4 (337)
15-3/4 (400)
Notes:
• All dimensions are given in inches (mm).
• Thickness recommended for reinforcements in
hollow metal doors and frames is charted at the
left of this page.
• Do not scale drawing.
• Left hand door shown.
• This template information based upon use of 5"
(127mm) maximum width butt hinges or 3/4"
(19mm) offset pivots. A separate template will
be supplied for other conditions.
• Maximum frame reveal is 7” (178mm) for this
application.
• Conduit hole nearest to hinge is suggested for
120 VAC power input.
1-11/16
(43)
1-1/4
(32) 11/16
(17.5)
1-3/4
(44)
12-15/16
(329)
7-9/16
(192)
13-7/16
(341)
3/8
(10)
C
LHinge or Pivot
1/4-20 Machine Screws
or No. 14 Wood Screws
(6 Places)
7/8
(22)
(Conduit Holes -
2 Places)
Dia.
Frame
Rabbet
Frame
Stop/Soffit
A
13-13/16
(351)
1/2
(13)
B
5-1/4”
Min.
Clearance
11-11/16
(297)
3/8
(19)
14-3/16
(360) 13-13/16
(351)
Left Hand Door
open to 110° shown.
5/8
(15.9) Stop
Sex Nuts
(2 Places)
2. Stop (Push) Side Mounting Instructions
2A. Installation Sequence
Left
Hand
Door
Right
Hand
Door
1-1/2”(38mm)
Min. Frame Face
Frame Reveal*
Door
5-1/4”(133mm)
Min. Ceiling
Clearance
1-3/4”(44mm) Min.
2-1/4”(57mm) Max. Door Thickness
*For frame reveals less than 3" (76mm) the
arm adjusting rod can be field cut to a length
of 9-1/2" (241mm) measured from centerline
of connecting link bushing assembly. Note: Door must be visible by person operating activation switch(es)
Step1: Determine hand of door from illustration on upper right of this
page.
Step2: Using template above locate and prepare holes in the frame &
door:
Frame
A.Prepare six (6) holes for 1/4-20 machine screws or No.14 x 2-3/4"
(70mm) wood screws.Blind rivet nuts (by others) are suggested
forunreinforcedhollowmetalframesorforaluminumframes.
B. Concealed Wired Units Only: Two (2) 7/8" (22mm) diameter
holesforconduit,forpowerinputandforswitch/sensorwires.
NOTE: On new construction these holes will generally be drilled
by the frame supplier at their shop or at the time the frame is
installedinthewall.
Door
C. Prepare two (2) holes for 3/8" diameter sex nuts. Standard units
are supplied with sex nuts and screws for 1-3/4" (44mm) thick
door. Sex nuts and screws for other door thicknesses are
availabletoorder.
Step3: Remove cover from the unit and set cover & cover screws
aside.
Step4: Mountunittodoorframe. SelectAorBbelow.
A. ConcealedWired Units Only:
B. SurfaceWiredUnits Only:
Connect conduit to frame side of
backplate. Fastenunittodoorframe(sixscrews).
Fastenunittodoorframe(sixscrews).
Mount conduit bracket (found in screw pack) to unit backplate
withtwoscrewsprovided. Connectwiringconduittobracket.
Please verify desired mounting
requires Stop (Push) Side
application as shown on this
template.
Page 6
ASSAABLOY
Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)

2A. Installation Sequence Continued
Step5: Install main arm onto pinion shaft of unit at a 90° angle to the
door frame. Align arm mark “S” with the flat corner of the
pinionshaftsquare. (SeeFig.3below.)
Step6: Secure main arm to pinion with 1/4-20 Flange Head Screw
provided. Tightenscrewwith7/16"wrenchorsocket.
Step 9: to
increase door closing power. Door control is shipped set at
midpoint of power setting.Maximum closing power can be
achieved with 8 (360°) clockwise turns of the power
adjustment screw.
Step 7: Mount arm shoe to door using 2 1/4-20 screws & sex nuts
provided with screw pack.
Step 8: PRELOAD ARM (See Fig.4, below): Remove 1/4-20 hex
head screw on adjusting rod and insert adjusting rod into
arm slide. Reinstall 1/4-20 screw and leave loose. Rotate
main arm in direction away from the hinge edge until the
adjusting rod and arm slide are perpendicular (at a 90°
angle) to the door frame.Tighten the 1/4-20 hex head screw
on the adjusting rod to secure arm in this new position.
Adjust closing power of unit (See Fig.5) - Using a 1/8” allen
wrench, turn the power adjustment shaft clockwise
Step 10:Adjust Hydraulic valves using a 1/8” hex wrench to obtain
proper door closing speeds. See following illustrations. Refer
to Table 1 on page 5 for recommended minimum opening /
closing times per ANSI/BHMA A156.19.
Note: A.D.A. requires that from an open position of 70°,
the door will take at least 3 seconds to move to a point
3”(75mm) from the latched position,measured at the
leading edge of the door.
Step 11:Make wiring connections using Wiring Instructions on Page
below and on Page 8.
Closing Cycle – Make adjustments, as necessary, to the
Sweep Speed "S" valve and Latch Speed "L" valve.See Fig.
6 below for location of valves.Turn valves clockwise to reduce
speed, counter clockwise to increase speed.
Opening Cycle – Adjust Backcheck, "B" valve, as
necessary, for hydraulic resistance to door opening in the
backcheck range.See illustration at bottom of this page for
location of valve.
NOTE:Too much Backcheck, "B" valve, can affect the
operation of the units pump, preventing units from fully
opening the door.This valve may require fine tuning
after all other adjustments have been made.
R
L
Y
S
Z
Arm Mark Pinion Flat
Figure 3
Adjusting
Rod
Arm
Slide
Door
Shoe
Main
Arm
Figure 4
Adjusting
Rod
Arm
Slide
Door
Shoe
Main
Arm
Power
Adjustment
1/8"
Hex
Key
Increase
Power
Decrease
Power Figure 5
1/8"
Hex
Key
Slower
Closing
Faster
Closing Closing Cycle
Closed
10°
e
g
n
a
R
h
c
t
a
L
e
g
n
a
R
p
e
e
w
S
1/8"
Hex
Key
Increase
Cushion
Decrease
Cushion
Opening Cycle
B
a
c
k
c
h
e
c
k
g
n
i
n
e
p
O
Sweep Valve
Latch Valve
Backcheck
Valve
Figure 8
Page 7
ASSAABLOY
Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)

Low Voltage
Control
Wiring
Incoming
Power
Optional Bracket
(for surface wiring) Ground
Lead Power
Leads
Ground
Screw
(Green)
Cable
Clamps Conduit
by Others
(from top)
“T1” Power
Input
Terminal
24
23
22
25
HOT
COM
Breaker Switch
T1 Terminal
Block
4. Final Electrical and Mechanical Setup
A. Confirm all mechanical adjustments have been made
and wiring connected per Page 7 and 8.
B.Turn on facility’s main circuit breaker.
C.Turn power to unit on at the Unit Power Switch and
turn the Breaker Switch to “RESET”.
D. Using a short jumper cable, jump terminals 1 and 2,
see Fig. 2 below, to activate unit. When door
reaches 20°, switch Breaker Switch to “OFF”
position cutting power to the unit. Allow door to
fully close (door may be manually pulled closed).
1
2
3
4
1
2
3
4
Figure 2
3. Input Power Configurations
CONCEALEDWIRING SURFACE WIRING
GroundWire Connection – Ground wire must be secured to backplate
underheadof(green)groundscrew.
Terminal Description
HOT
25
23
24
22
COM Commonpowerlead
Hotpowerlead
CircuitBreaker
Switch
CircuitBreaker
Common connection to Circuit Breaker /
Inverter
Thread conduit fitting(s) into backplate as shown. A second
conduit fitting is required for low voltage control wiring. CHECK
LOCALCODES. Pullconduitoutofheaderandattachtoconduit
fittings before mounting Secure operator to door frame. Attach
incoming ground wire to backplate with ground screw as
illustratedin“SurfaceWiring”illustrationtotheRight.
Thread conduit fitting(s) into backplate as shown. A second
conduit fitting is required for low voltage control wiring. CHECK
LOCAL CODES. Pull conduit out of header and attach to conduit
fittings before mounting Secure operator to door frame. Attach
incoming ground wire to backplate with ground screw as illustrated
below.
Breaker
Switch
Unit Power Switch
Page 8
ASSAABLOY
Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)

4. Final Electrical and Mechanical Setup Continued
E. Adjust Closing Position Magnet (See Fig. 3) - With
door in the closed position, use finger to slide Closed
Position Magnet so it aligns directly with the Reed
Switch.
F. Adjust Open Position Magnet - Use fingers to slide
F cont. Open Position Magnet 180° from Open Position
Magnet.
G. Flip Breaker Switch to “RESET” to turn power on.
Jump terminals 1 and 2 (as shown in Fig.2) to
activate door. Note open position of the door. Allow
door to close.
H. Use finger to readjust the Open Position Magnet to
desired door open position.
I. Repeat Step G to verify door open position.
J. Make all connections necessary for any accessories to
the 4-position Accessory Terminal (see Pages 10-11).
K. Make necessary adjustments to inverter (see Page 9).
Replace cover and cover screws.
Reed Switch
Closed Position
Magnet
Open Position
Magnet
Position Ring
Figure 3
Inverter Adjustments:
•Based on function
adjustment desired,
use table above to
determine which POT
is to be adjusted.
POT FUNCTIONDESCRIPTION
OBSTR SENS Obstruction Detection on Open CW - Increase
CCW - Decrease
M/DLY Motor Delay on Opening CW - Increase
CCW - Decrease
P1 Closing Speed CW - Increase
CCW - Decrease
H/O TM Hold Open Time (5 - 30 Seconds) CW - Increase
CCW - Decrease
P2 Opening Speed CW - Increase
CCW - Decrease
H/O TQ Motor Torque at Hold Open
Position CW - Increase
CCW - Decrease
ON
12
WARNING
120 HIGH VOLT POTENTIAL PRESENT. MAKE
SURE POWER ISTURNED OFF DURING
INSTALLATION PROCEDURE.
Dip Switch Settings
1. Door Mounting -
2. Push Recognition -
ON - pull
OFF - push
ON - active
OFF - inactive
WARNING
Electric
Shock Risk
(Adjustments made in the shaded
area should be performed by
Authorized Factory Personnel.)
L2
115Y
L1 115/230VAC IN
MOTOR OUT
L2
230Y
U
V
W
STATUS LEDS
H/O TQ H/O TM
OBSTR
SENS
P1
M/DLY P2
1 6
COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
PULL PUSH
SW501
ON
12
Inverter Details
Page 9
ASSAABLOY
Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)

Standard Function with Switches
1
2
3
4
1
2
3
4
Notes:
1.Power input to Door
Operator Unit is at “T1”
Power Input Terminal (not
shown) 120VAC 60Hz.
Wall Switch, Card
Reader, Key Switch,
etc.
1
2
3
4
1
2
3
4
Door 1 Door 2
Operation:
•
• Activating either switch will
open both doors. Door will
close after hold open time
delayhaselapsed.
Doors arenormallyclosed.
Wall Switch, Card
Reader, Key Switch,
etc.
Normally Open Momentary
dry contacts
Normally Open Momentary
dry contacts
Radio Frequency Function Option
1
2
3
4
1
2
3
4
Optional Door 2
1
2
3
4
1
2
3
4
Door 1
Notes:
1.Power input to Door Operator
Unit is at “T1” Power Input
Terminal (not shown) 120VAC
60Hz.
2. Radio Frequency Feature can
be purchased as a separate kit.
Operation:
• closed.
• Activating wireless
switch or hand held
wireless transmitter
will open the door.
• Door will close after
hold open delay
elapses.
Door is normally
120
VAC
Ground
COM
HOT
L N
(AC) -V +V ADJ +
1.1A 24V Power Supply
12-24 V
AC/DC
COM
NO
NC
Troubleshooting
Jump activation input
Change the setting of the ON/OFF switch
Flip Door Mounting Dip Switch to other direction
Remove object
Re-time and re-install arm.
Increase spring tension per preceding instructions
Remove object
Fault Possible reasons why Remedies/Explanations
The door does not open
- The motor does not start Control switch is set to OFF position
Electrical power is missing the electricalCheck power switch
Activation unit does not function
- The motor starts Motor is driving in wrong direction
Something jammed beneath the door
Arm has come loose
The door does not close Spring tension too low
Arm has come loose Re-time and re-install arm.
Something jammed beneath the door
Circuit breaker is set to OFF position Reset circuit breaker to the ON position
Page 10
ASSAABLOY
Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)

Fail Secure / Fail Safe Electric Strike Wiring
120VAC
Supplied by
Others
-+
DC or AC
Output
AC or DC
Electric Strike
+
-
Wall Switch, Card
Reader, Key Switch,
etc.
Normally Open Momentary
dry contacts
Notes:
1.Power input to Door Operator Unit is at “T1”
Power Input Terminal (not shown) 120VAC
60Hz.
2.Unit’s Relay Rating for strike interface:
30VDC @ 1A or 125VAC @ .5A
Operation:
•
• Activating switch will unlock the electric strike
andthe door willautomaticallyopen. Door will
closeafterholdopentimedelayhaselapsed
• For Fail Secure Strike -The door will remain
lockedduringpowerfailure
• For Fail Safe Strike - The door will remain
unlockedduringpowerfailure.
Doorisnormallyclosedandlatched.
1
2
3
4
1
2
3
4
JMP503
NC
NO
Jumper Settings
Place jumper to upper
position for normally
closed operation or to
lower position for
normally open operation.
Fail Safe Electromagnetic Lock 24VDC Wiring
1
2
3
4
1
2
3
4
Wall Switch, Card
Reader, Key Switch,
etc.
Normally Open Momentary
dry contacts
+
-
24VDC Electromagnetic Lock
(Fail Safe)
Operation:
•
• Activatingswitchwillcutpowertomaglockandthedoorwillautomatically
open. Doorwillcloseafterholdopentimedelayhaselapsed.
• Thedoorwill unlockduringpowerfailure.
Doorisnormallyclosedandlatched.
Notes:
1.Power input to Door Operator Unit is at “T1”
Power Input Terminal (not shown) 120VAC
60Hz.
2.Unit’s Relay Rating: 30VDC @ 1A or
125VAC @ .5A
Jumper Settings
Place jumper to upper
position for normally closed
operation or to lower position
for normally open operation.
JMP503
NC
NO
120
VAC
Ground
COM
HOT
L N
(AC) -V +V ADJ +
Optional 1.1A 24V
Power Supply
Page 11
ASSAABLOY
Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)

Page 12
Troubleshooting
Red LED
Blue LED
Antenna Wire
Learn
w/o Delay
Button
Delay
Potentiometer
(Time Adjustment)
Learn w/
Delay Button
DIP Switch
Terminal
Strip
Problem: The LED on my receiver is just flickering and I’m unable to program and/or it won’t work.
Solution:You have a push plate stuck or faulty transmitter. Disconnect each push plate until the LED goes out. If LED
does not go out, remove each transmitter battery until it does. Replace the appropriate transmitter.
Problem: Receiver intermittently doesn’t receive the transmitter(s) signal.
Solution:You may extend the receiver antenna wire only in multiples of 6-3/4” (171), i.e.6.75 x 4 = 27” (686) of extended
antenna wire.
RemovingTransmitter Code(s)
SingleTransmitter Code:
ŸPress both Delay and No Delay Buttons simultaneously until Red LED flashes once (approximately 1 second).
ŸPress transmitter button twice within 10 seconds and the transmitter code will be deleted.
AllTransmitter Codes:
ŸPress and hold both Delay and No Delay Buttons simultaneously until Blue LED illuminates then release (approximately 10
seconds).
Push Plate Configuration
1. Before beginning, it is easiest to have already prepared the installation of the push plate.
2. Connect the wires from the transmitter to the NO and COM contacts of the push plate’s switch.
3. Follow Steps 1 - 4 (Hand-Held Configuration); depress the push plate to activate the transmitter.
4. Attach the transmitter to the inside of the electrical box and complete the installation.
Hand-Held Configuration
1. Set dip switches to the receiver to the desired activation cycle (dip switch 1 - Toggle or Pulse and dip switch 2 - 0.5s or 10s
hold.
2. Press either Learn w/ Delay Button or Learn w/o Delay Button on the receiver depending on the activation requirements (if
delay learn is selected, adjust potentiometer to counterclockwise limit, 0 second delay). Red LED on receiver will flash.After
learn cycle is complete, adjust potentiometer to desired delay time (0 - 30 sec).
3. Depress transmitter button repeatedly until Blue LED on the receiver illuminates (indicating reception of signal from transmitter).
NOTE: Repeat Steps 2 - 3 to program additional transmitters.
4.To test the system, depress transmitter button (Red LED on Transmitter will illuminate) and observe that the Blue LED
illuminates on the receiver.This indicates that the relay has been activated.
433MHz Receiver User’s Guide
#2
OFF
ON
Description
0.5s Hold Time
10s Hold Time
Function
Relay will remain active 0.5 sec after loss of activation.
Relay will remain active 10 sec after loss of activation.
#1
OFF
ON
Description
Pulse Relay
Toggle Relay
Function
Press the transmitter once and the relay will be active
momentarily.
Press the transmitter once and the relay output is
active indefinitely, press it again and the relay will de-
energize indefinitely.
ON
1 2
PUL TOG
0.5s 10s
ON
1 2
PUL TOG
0.5s 10s
In Toggle Setting (1-ON), the
Hold Time is inactive.Either
setting for #2 dip switch will
have the same result.
ON
1 2
PUL TOG
0.5s 10s
0.5 second
Pulse Setting
ON
1 2
PUL TOG
0.5s 10s
10 second
Pulse Setting
ŸAlways stop pedestrian traffic through the
doorway when performing tests that may
result in unexpected reactions by the door.
ŸEnsure compliance with all applicable safety
standards upon completion of installation.
ASSAABLOY
Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)

Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)
This Page
Left Blank
Page 13
ASSAABLOY

Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)
Removable Template - Hinge (Pull) Side
ŸDo not scale drawing.
ŸRight hand door shown.
ŸAll dimensions given in inches (mm).
ŸMaximum frame reveal is 1/8” (3 mm)
for this application.
Note: Door must be visible by person
operating activation switch(es)
Door Opening
Angle Dim“A”
Up to 110°
111° to 180° 15-1/2 (394)
13-1/4 (337) Notes:
• All dimensions are given in inches (mm).
• Thickness recommended for reinforcements in hollow
metal doors and frames is charted on Page 2.
• Do not scale drawing.
• Right hand door shown.
• This template information based upon use of 5"
(127mm) maximum width butt hinges. A separate
template is required for other conditions.
• Maximum frame reveal is 6-7/8” (175mm) for this
application.
• Conduit hole nearest the hinge is suggested for 120
VAC power input.
2”(51mm)
Min.
Frame Face
1-1/8”
(29)
1-1/4
(32) 1-7/16
(37)
11
(279) 22
(559)
7-9/16
(192)
13-7/16
(341)
1-1/8
(29)
C
LHinge
1/4-20 Machine Screws
or No. 14 Wood Screws
(6 Places)
7/8 (23) Dia.
(2 Places)
3/8 Dia.
Sex Nuts
(3 Places)
Frame
Rabbet
Frame
Stop/Soffit
3
(76)
13-13/16
(350)
1/2
(13)
A
11-11/16
(297)
6”
(152mm)
Min.
Clearance
14-3/16
(360)
12-15/16
(329) 13-13/16
(351)
Right Hand Door
opening to 110° shown.
5/8
(15.9) Stop
Left
Hand
Door
Right
Hand
Door
2”(51mm)
Min. Frame
Face Frame Reveal
Door
6”(152mm)
Min. Ceiling
Clearance
1-3/4”(44mm) Min.
2-1/4”(57mm) Max.
DoorThickness
Please verify desired mounting
requires Hinge (Pull) Side
application as shown on this
template.
Page 14
ASSAABLOY

Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)
Removable Template - Stop (Push) Side
ŸDo not scale drawing.
ŸLeft hand door shown.
ŸAll dimensions given in inches (mm).
ŸMaximum frame reveal is 1/8” (3 mm)
for this application.
Door Opening
Angle Dim“A” Dim“B”
Up to 110°
111° to 170° 12 (305)
9-1/2 (241) 13-1/4 (337)
15-3/4 (400)
Notes:
• All dimensions are given in inches (mm).
• Thickness recommended for reinforcements in
hollow metal doors and frames is charted at the
left of this page.
• Do not scale drawing.
• Left hand door shown.
• This template information based upon use of 5"
(127mm) maximum width butt hinges or 3/4"
(19mm) offset pivots. A separate template will
be supplied for other conditions.
• Maximum frame reveal is 7” (178mm) for this
application.
• Conduit hole nearest to hinge is suggested for
120 VAC power input.
1-11/16
(43)
1-1/4
(32) 11/16
(17.5)
1-3/4
(44)
12-15/16
(329)
7-9/16
(192)
13-7/16
(341)
3/8
(10)
C
LHinge or Pivot
1/4-20 Machine Screws
or No. 14 Wood Screws
(6 Places)
7/8
(22)
(Conduit Holes -
2 Places)
Dia.
Frame
Rabbet
Frame
Stop/Soffit
A
13-13/16
(351)
1/2
(13)
B
5-1/4”
Min.
Clearance
11-11/16
(297)
3/8
(19)
14-3/16
(360) 13-13/16
(351)
Left Hand Door
open to 110° shown.
5/8
(15.9) Stop
Sex Nuts
(2 Places)
Left
Hand
Door
Right
Hand
Door
1-1/2”(38mm)
Min. Frame Face
Frame Reveal*
Door
5-1/4”(133mm)
Min. Ceiling
Clearance
1-3/4”(44mm) Min.
2-1/4”(57mm) Max. Door Thickness
Note: Door must be visible by person operating activation switch(es)
Please verify desired mounting
requires Stop (Push) Side
application as shown on this
template.
Page 15
ASSAABLOY

Norton® is a registered trademark ofYale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission ofYale Security Inc. is prohibited. 80-9357-0008-020 (Rev 3)
3000 Highway 74 East • Monroe, NC 28112
Tel: (800)-438-1951 x4706 • Fax: (800)-338-0965
www.nortondoorcontrols.com
ASSAABLOY
This Page
Left Blank
Page 16
ASSAABLOY
Table of contents
Popular Gate Opener manuals by other brands

Erreka
Erreka MAGIC Installer manual

Automatic Technology
Automatic Technology NeoSlider NES-500 manual

Chamberlain
Chamberlain ELITE CSL24V installation manual

CAME
CAME BY-3500T installation manual

DKS
DKS 6400 - UL 325 Class 1 owner's manual

GFA
GFA ELEKTROMAT SE 9.80 FU-25,40 RS09/80ERDU installation instructions

INSTALMATIC
INSTALMATIC ARTEMIS 230V Technical manual

Chamberlain
Chamberlain CSW24UL installation manual

Becker
Becker R7/17M Assembly and operating instructions

Merlin
Merlin WingMate 3 Installation and operation instructions

GTO
GTO SW-2000XL installation manual

Nice
Nice mindy A400 Instructions and warnings for the fitter