Your excellent helper in cable test!
Wire Fault Locator
MODEL:NF-300
Your excellent helper in cable test!
SHENZHEN NOYAFA ELECTRONIC CO.,LTD

Please read and learn safety instructions
before use or maintain the equipment
●Keep t h e testers in right p lace to avo id hurt wit h the shar p p robe.
●Neve r p ut the equ i pment in t h e place wi th much dus t, humidi ty
and hig h temper a ture (ov e r 40℃).
●Plea s e use batt e ry accor d ing to the s pecific ation; ot herwise , it
may res ult in dam a ge to equi p ment.
●Plea s e never di s mount th e e quipme nt arbitr arily. The ma inten
-ance a nd care sh a ll be cond u cted by pr ofessio nal perso nnel.
● The tester wi ll shut off automatically if i t does not wo rk for
15 minu tes in succession.
●Plea s e take out t h e batter y i n launch er and rece iver if the
equip ment is no t u sed for a lo n g time so as t o p revent t hat the
batte ry liqui d i s leaked i n f uture.
●Neve r u se the equ i pment to d e tect pow er cord wit h electri city
(such a s power su p ply circ u it of 220V ) , other wi se, it may
resul t in damag e t o equipm e nt and per sonal inj ury.
●Neve r c onduct r e lated op e ration o f communi cation li ne in
thund erstor m w eather s o a s to preve n t lightn ing strok e and
impac t on perso n al safet y.
Your excellent helper in cable test! Your excellent helper in cable test!
CONTENTS
Overview......................................... .....01
Main functions .................................. ...02
Technical Parameters...................... .....02
Product interface and key introduction. .04
Product operation method......... ...........05
a.Cable line-to-line test......................... .....05
b.Cable length test...................... ..............09
c.Cable tracing test..................... ......12
d.Crosstalk test............................... .........15
....
....
....
...
....
....
....
............
....
Language Calibrate .................................16
Data loading.............................................16
Language:Chinese or English...................16
Setup .......................................................17
Unit .........................................................17
Light ........................................................18
Auto off ...................................................18
Auto-off time ...........................................18
Packing list..............................................19
Diagram of series products ......................20

●
connection and broken wire positioning ( RJ11,RJ45, BNC C ).
● To perform crosstalk test on network cable to solve the potential
problem of slow speed.
● To quickly find the target wire or cable among kinds of wires.
● Measure length of network cable, coaxial cable up to 2500m, no
need of remote unit when measuring length.
● To make a accurate determination of short circuit position .
● To trace cable on exchanger or Router without current
inteference.
● Low voltage prompt function is available (<6V).
● Functions of storage and memory
.
● Automatic delay power on-off and backlight function.
● Lanuage& light brightness can be set in the system
.
● Single chip software watchdog design runs reliably.
Capable to test open, short , cross connection, reverse, pairing
able
Main functions
Overall dimensions
Main tester: 175X80X43mm; Receiver: 218X46X29mm
Remote identifier: 107X30X24mm.
Display
Dot matrix 128X64 (Effective visible area 56X40mm).
(1).
(2).
(3). Power supply
Main tester: 9V battery.
Receiver: 9V battery.
(4).Testing cable types
STP/UTP 5E, 6E network cable, telephone cable, coaxial cable,
and common metal wires connected with alligator clip.
Technical parameters
01
Overview
NF-300 is capable
of avoiding current inteference . The equipment is composed
of three parts: main tester (NF-300), receiver (NF-300-S) and
remote identifier (NF-300-R).It has couples of circuit state testing
functions including length test, cable line finding, line-to-line,
crosstalk and breaking point, serving as a practical tool for low
voltage system installation and maintenance technicians
of communication circuits and comprehensive wiring circuits. It is
widely used in the fields like telephone system, computer networks
and other metal lead circuits.
newly developed by our company which are
NF-300-R
WIREMAP
Remote identifier
(NF-300-R)
Main tester
(NF-300)
Receiver
(NF-300-S)
POWER
PUS H TO TEST
NF- 300 -S
VOL
Wir e Fault L ocato r
RECEIVER
Anti-EI Wire Tracer
NF -300
Wir e Fault L oca tor
EMITTER
Anti-EI Wire
Tracer
NOYAFA
Lang RJ11
RJ45
02
Your excellent helper in cable test! Your excellent helper in cable test!

03
(5).Detecting cable types
STP/UTP 5E, 6E network cable, telephone cable, coaxial cable,
USB cable and common metal wires connected with alligator clip.
(6).Operating environment temperature/humidity
-10 ~ +60 /20% ~ 70%;℃ ℃
(7).Testing device interface
Main unit: RJ45 (M), RJ45 (S)loop interface, RJ11main interface,
BNC connector,USB A-type female interface;
Remote identifier: RJ45, BNC connector。
RJ11 loop interface,
(8).Length measurement
Range: 1-2500m;
Calibration precision: 2% (+/-0.5m, or +/-1.5 feet); (calibration;
cable >10m) measurement precision: 3% ((+/-0.5m, or +/-1.5 feet);
(AMP, CAT5E, 6E cable material)
Display unit: meter, inch, yard.
(9).Length calibration, storage and data load
User can set a length value at a known length, store the value in
the system,which can be used for future choice. and the calibration
length should be over 10m.
(10). Line sequence and cable failure positioning
Open, short, reverse , cross, crosstalk, etc.
(12). Setup
Unit & brightness & Auto-power off time can be set in this menu.
(11). Language set
Users can choose English or Chinese for operation.
NF- 30 0
Wir e Fault L ocato r
EMITTER
Anti-EI Wire
Tracer
NOY AFA
Lang RJ11
RJ45
POW ER
PUSH T O TEST
NF-3 00-S
VOL
Wire F ault Lo cator
RECEIVER
Anti-EI Wire Tracer
Main tester (NF-300) Receiver (NF-300-S)
Remote identifier (NF-300-R)
Product interface and key introduction
Main unit port instructions
(1). Two RJ 45 interfaces on the main unit:
one of them is “MAIN” interface (“M” for short),
and the other is “SCAN” interface (“S” for short);
Two RJ11 interface, USB-A interface
and BNC interface
(2). M interface is used for measuring length and
others, but not for cable tracing; “S” interface is
used for cable tracing test and “local” connection test;
(3). “Main RJ11" interface, USB interface and BNC
interface on the main unit are used for line-to-line,
length testing and line tracing; The
other RJ11 interface can be used
for checking wiremapping.
04
RJ11 USB-A
POWER
SCAN
BNC
RJ11
MAIN
RJ45
NF- 300 -R
WIRE MAP
Your excellent helper in cable test! Your excellent helper in cable test!

NOYAFA
Product operation method
5 seconds later, the following main interface is displayed:
Bootscreen
Synchronous self test ( self test dynamically displayed in the line
from left to right)
------
05
welcome
to ch oos e noyafa
NF- 300
There are six functional options in the main menu interface
(1) Language— English or Chinese.
(2).RJ45 --- wiremapping / length measurement /
cable tracing / crosstalk testing
(3).RJ11—
(4).USB— Cable tracing
(5).BNC—
(6).Setting up— unit / light / auto-power-off time
Note:
Calibration— Seven calibration coefficient can be stored in it.
User can calibrate network/ Coax cables.
Data loading---Select the calibration coefficients stored in system.
wiremapping / cable tracing
wiremapping / length measurement / cable tracing
----identify----
Taking network test as an example: after entering RJ45 function to check
wire mapping.At this time, the following interface is shown indicating test
is in process:
a.Cable line-to-line test:
USB BNC Setup
Scan C a ble
Cable Len g t h
Wire Mapping
NOYAFA
Test result 1: Short circuit
Sho r t mappi n g:
1 2 3 4 5 6 7 8
Cab l e ope n or
too Short !
If there is short circuit with the cable and terminal, it will show as below:
(Short circuit with 3 and 6)
At this time, press any key to return to the main menu, and then press
“ENTER” key for re-test.
Please do not perform test again until short circuit problem solved.
Test result 2: if the far end of the cable to be tested is not plugged in
remote adapter (R) or cable is not plugged into the local port (S),
the following interface is shown:
Test result 3:correct connection
the following interface is shown:
“M”stands for Master unit. “R” stands for remote unit “G” stands
for “Grounded”.
06
1 2 3 4 5 6 7 8 G
M:
R: 1 2 3 4 5 6 7 8 G
Wire Map: Remote
Your excellent helper in cable test! Your excellent helper in cable test!
RJ11
RJ45
Lang
NOYAFA

07
Note: Because network cable is made of pair cores, if there is open circuit,
it will show faults in pairs, just as above "4" &" 5". it means either "4" pin
or "5" pin exsits an open circuit, or both "4" and "5" exsit an open circuit.
Test result 5: In case of open circuit existing at the near end of
the cable , the following interface
is shown:
when testing only with main tester
In the figure, “X” shown in “3” and “6” pin position in “M” line, indicates there is
open circuit in “3” and “6” pin of the near pin.
Test result 6: In case of open circuit existing at the middle part
of the cable , the following
interface is shown:
when testing only with main tester
In the figure, “X” shown in “3” pin position in “M” and “S” line, indicates there is
open circuit in “3” pin of the middle part of the cable. Perform"Cable Length"
to locate the exact fault point. Refer to the related chapter below.
1 2 X 4 5 X 7 8
M:
S: 1 2 3 4 5 6 7 8
Wire Map: Local
1 2 X 4 5 6 7 8
M:
S: 1 2 X 4 5 6 7 8
Wire Map: Local
Test result 4: In case of open circuit existing on far end of the cable,
the following interface is shown:
In the figure, “X” shown in “4” and “5” pin position in “R” line, indicates there is
open circuit in “4” and “5” pin of the remote pin.
1 2 3 4 5 6 7 8 G
M:
R: 1 2 3 X X 6 7 8 G
Wire Map: Remote
08
Test result 8: 6-core telephone cable line sequence test
At this time, press any key to return to the main menu, and then press
“ENTER” key for re-test.
Note: when checking wiremap of telephone cable, users can only test with
main testers, for the remote unit has no RJ11 port.
Test result 9: BNC coaxial cable line sequence test
Before checking wiremap of telephone cable, users need to choose "RJ11"
and then check its wiremap. If the testing cable is in good connection, it will
displays as follows:
Before checking wiremap of BNC cable, users need to choose "BNC"; and
then check its wiremap. If the testing cable is in good connection, it will
displays as follows:
Wire Map: Local
Wire Map: Remote
At this time, press any key to return to the main menu, and then press
“ENTER” key for re-test.
1 2 3 4 5 6
M:
S: 1 2 3 4 5 6
1 2
M:
R: 1 2
Test result 7: In case of open circuit existing in the cable when
testing with main tester and remote unit together, the following
interface is shown:
In the figure, “X” shown in “4” & “5” pin in “M” & “R” line, It has two possible results.
Both “4” and “5” pin are open curcuited. Or , either “4” or “5” pin is open.
Note: When checking wiremap with main tester and remote unit together,
the cable is tested in pair. Thus, if there is one pin is open , it will show in pair
as above.
To test which pin is open, users can check wiremap only with main tester like
Example 4,Example 5 and Example 6 do.
1 2 3 X X 6 7 8
M:
S: 1 2 3 X X 6 7 8
Wire Map: Local
Your excellent helper in cable test! Your excellent helper in cable test!

09
Special use:
can test line sequence of the connecting cables
In case of exchanger power-on, the main unit
Take network cable as an example: one end of the cable is connected with
“MAIN” interface of the main unit, and other end is connected with exchanger
interface. And direct connection test can be performed. If the exchanger
interface tested is reliably connected, the following interfaces shown (exchanger
interface is 8-core):
In case of open circuit with line 1 and 2 of the exchanger tested, the following
interface is shown (exchanger interface is 8-core):
12345678
Short mapping:
12345678
Short mapping:
b.Cable length test:(Test length only with the main
tester,don’t connect cable into remote unit.)
Firstly insert one end of the testing cable into “M” port in the main tester. When
entering ”Cable Length” testing function to check the length.At this time, the
following interface is shown:
Note: Due to different technical parameters with different branded cables,
users are recommended to use dynamic calibration function of the equipment
before measuring length (Refer to the related chapter for more details.).
----identify----
Scan C a ble
Cable Len g t h
Wire Mapping
NOYAFA
10
Test result 1: Short circuit
If there is short circuit with the cable and terminal, the following interface is
shown (Short circuit with 3 and 6)
At this time, press any key to return to the main menu, and then press
“ENTER” key to other functions.
Please do not perform test again until short circuit problem solved.
Sho r t mappi n g:
12345678
1 Open 10 5.0 m
4 Open 10 5.0 m
2 Open 10 5.0 m
3 Open 10 5.0 m
Test result 2: In case of normal pairing and length test,
the following interface is shown:
And then press “UP” or “DOWN” key, the following interface will further
be shown:
5 Open 10 5.0 m
9 Open 10 5.0 m
6 Open 10 5.0 m
7 Open 10 5.0 m
Thus , the cable is almost 105m . Only one end of cable connect with main
tester, the other end needs no connection, so it show "Open" in the picture
.
At this time,press “ENTER” to return to the main menu,and then press
“ENTER” key for re-test.
Your excellent helper in cable test! Your excellent helper in cable test!

11
Test result 5: BNC cable length test
If to insert one end of the BNC cable to be tested into “BNC” port of the main
tester, the other end is an open circuit, and then select length test, and then
press “ENTER” key to perform length test with the equipment, the following
interface will be shown:
It indicates that length of BNC cable is 10.1m. At this time, press any key to
return to the main menu, and then press “ENTER” key for re-test.
1 Open 1 0.1 m
2 Open 1 0.1m
12
Scanning...
c. Cable tracing test:
After powering on the main tester and entering main test menu, press “UP”,
“DOWN” key to move “ ” cursor to cable scan, and then press“ENTER”
key to find the line. The following interface will be shown:
Connect the cable to be found with the corresponding RJ45(Scan) port
, (RJ11,USB or BNC). Take network line finding as an example:
connect the network cable to be found with RJ45 port, move “ ” cursor to
cable scan, and press “ENTER” key to perform line finding test as shown in
the figure below:
of the
emitter
Your excellent helper in cable test! Your excellent helper in cable test!

1.Tracing cable (RJ45/RJ11 Cable) which is connected to
switch or router.
Insert the cable into port RJ11/ RJ45 (S), Press the testing key of receiver, “Power”
will be lighted, then hold the receiver close to the cables, when the probe gets close
to the targeted one, you can hear clear and loud “beep,beep, beep” .
(Note: telephone cable into RJ11, Lan cable into port RJ45(S) )
The usage of receiver
Install 9V battery, push the test key, get close to the cables with probe.you can
hear “beep”, the power led flashes. When the probe finds the targeted cable,the
voice will be loudest, and the led light will be brightest.
13
2.Tracing Coax cable
Insert the cable into port BNC, Press the testing key of receiver, “Power” will be
lighted, then hold the receiver close to the cables, when the probe gets close to the
targeted one, you can hear clear and loud “beep,beep, beep” .
(Note: turning down the voice slowly help trace cable easiler. )
3.Locate the short or breakge point (eg: metal line)
Connect the metal line with the cable clips, press the testing key of receiver, hold
the receiver close to the cables, “beep, beep,beep” will generate, but when the
probe targets the breakge point, “beep,beep,beep” stops, which indicates that
is where the breakage is.
Note: 1) the metal line is de-energized.
2) Turn up the voice, which helps locate breakge easily.
3) Two cables must be connected together, if only one cable, the black clip
has to be grounded.
14
Your excellent helper in cable test! Your excellent helper in cable test!

d. Crosstalk test
As shown the figure below: it shows 3, 6 and 4, 5 with crosstalk. The line
pair with crosstalk will flash to indicate failure. In the line pair with crosstalk,
end-to-end connection is correct. However the connected lines are from
different line pairs. Line pair crosstalk will cause an over large crosstalk,
otherwise network speed will be slow.
Crosstalk interface is shown as below:
Note: In case of the non-twisted-pair cable like telephone cable,
due to over large crosstalk, it generally shown as crosstalk.
15
M:
R:
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Crosstalk line pair flashes
Wire Map: Remote
16
Language: Chinese or English
The screen is as below.
Calibration ?
No Ye s
12.5m
Length Calibrate
The calibrated cable must be more than 10m, When starting dynamic calibration,
insert the same type of cables at a specified length into “M” port. It is unnecessary
to insert into remote unit.
Select “Yes”, and then press “ENTER” key, the measured length will be shown:
At this time, press “UP” or “DOWN” key to adjust to show the actual length
as below:
--Ba s e Adj u st---
When length is given, press “ENTER” key to save the calibration value. The
screen will show calibration 1, cabliration 2...calibration 7. Users can choose
it from “Data load”, which can avoid more calibration next time.
Data loading:
Choose the functions of “Load data”, it will show 7 sets of length values which
were stored before. Select the desired one and then start to test the cable length.
C a l i br at e 1
C a l i br at e 2
C a l i br at e 3
C a l i br at e 4
C a l i br at e 5
C a l i br at e 6
C a l i br at e 7
Re tu rn
E n g l i s h
Re tu rn
简体中文
NOYAFA
Your excellent helper in cable test! Your excellent helper in cable test!
3
4
5
6
3
4
5
6
Connection diagram of crosstalk line pair

NOYAFA
NOYAFA
USB BNC Setup
17
Unit :
When moving cursor to “Unit” item, choose “meter”,The following
interface will be shown:
“ ”
Note: Setup of the unit of inch and yard is just the same as that of meter.
Choose English, then the screen will be as below.
Setup
Choose “Setup” on the main menu,you will get the below screen ,
Set unit: meter
Lang USB BNC SetupRJ11
RJ45
NOYAFA
L i g h t : H i g h
Au to o ff :O N
U n i t : M e t e r
NOYAFA
L i g h t : H i g h
Au to o ff :O N
U n i t : M e t e r
NOYAFA
18
move “ ” to “Ligh”, choose the brightness degree you need
as below shows.
move“ ” to “ Auto off” , start power-off function to ON,
the screen would be like below.
Auto-off time
Choose the time as you need, 15 mins, 30mins, 60mins,120mins.
Light
Auto off
move “ ” to “Auto-off time”, it will show as below.
L i g h t : H i g h
Au to o ff :O N
U n i t : M e t e r
NOYAFA
L i g h t : H i g h
Au to o ff :O N
U n i t : M e t e r
NOYAFA
Au to o ff :O N
Au to o ff- ti me
L i g h t : H i g h
NOYAFA
3 0 m in
6 0 m in
1 5 m in
NOYAFA
Your excellent helper in cable test! Your excellent helper in cable test!

1. Emitter 1PCS
2. Receiver 1PCS
4. Earphone 1PCS
6. RJ45 Adaptor cable 1PCS
7. Alligator clip adaptor 1PCS
5. RJ11 Adaptor cable 1PCS
8. User manual 1PCS
9. Kit 1PCS
10. Color box 1PCS
3. Remote adapter 1PCS
Packing list
19 20
NF-388 NF-903 NF-906A
NF-268
NF-468L NF-3468 NF8108-M
NF-806R NF-816
NF-868 NF-838 NF-8208
STATUS
NF-268
SCAN
OFF
TEST
VERIFY
OFF
SCAN
POWER
Anti-EI Wire Tracer
Anti-EI Wire Tracer
Your excellent helper in cable test! Your excellent helper in cable test!
Table of contents
Other NOYAFA Test Equipment manuals