1、Overview
The instrument is Portable Building Electronic Thermometer is a
pr of es si o n a l tem p era tu re m eas u ri ng i ns tr um en t de v el op ed
acco rdin g to the construction characteristics of my country's
construction industry and relevant technical specifications. It can
displaythemeasuredtemperatureintuitively,accuratelyandquickly,
with good reliability, wide range of use and applications. Warm
operating environment, small size and light weight, easy to carry,
suitable for construction sites and field operations; mainly used for
const ruction, bu ildin g materials, water conservancy, electric power,
metallurgy, petrochemical, ports, roads and bridges, municipal and
otherbasicconstructionprojects.
2、ScopeOfApplication
The instrument is suitable for on-site construction temperature
measurement of various construction projects. It can be used with
temperature measurement probes to measure the temperature of
materialsandclinker,suchas:gas,liquid,fluid,mixtureandgranular
materials; and embedded temperature measurement line. It can be
used to measure the internal temperature of winter construction
concreteandmassconcrete.
3、Thecompositionandfunctionoftheinstrument
建筑电⼦测温仪
NF-514
36.8
Switch Backlight
Lighting
Temperature range
Measurement Error
Environment Temperature
Shenzhen Noyafa Electronic Co., Ltd
LCD
Power Switch
Power Switch
Backlight Switch
Temperature Probe
Temperatureprobe
Thetemperaturemeasuringprobeismadeofaplug,awire,ahandle
and a metal tube with an outer diameter of Φ5mm×220mm. The
frontendofthetubeispackagedwithatemperaturesensor,whichis
suitableformeasuringthetemperatureofmaterialsandclinker.
2
MainTester
The instrument is suitable for on-site construction temperature
measurement of various construction projects. It can be used with
temperature measurement probes to measure the temperature of
materialsandclinker,suchas:gas,liquid,fluid,mixtureandgranular
materials; and embedded temperature measurement line. It can be
used to measure the internal temperature of winter construction
concreteandmassconcrete.
1
Temperaturemeasurementline
3
Theembeddedtemperaturemeasuringlineismadeofaplug,awire
and a temperature sensor, which is suitable for measuring the
internal temperature of the concrete. Each temperature measuring
linecanmeasurethetemperatureatonepoint,andthetemperature
measuringpointcanbearrangedarbitrarilyduringtheconstruction.
In order to facilitatelayered temperaturemeasurement,the plugof
each temperature measurement cable has a label affixed with a
correspondinglengthspecification.
4、Themaintechnicalindicators
Temperaturemeasurementrange:-30°C~150°C
Temperaturemeasurementerror:≤±0.5°C
Operatingenvironmenttemperature:20°C~50°℃
Displaymode:3-digitLCDscreen
Powersupply:9Vlaminatedbattery
Weight:200g
Hostvolume:135mm×72mm×32mm
Resolution:0.1°C
1
2
3
4
5
6
7
8
5、Usemethod
Usethehostandtemperatureprobetomeasurethetemperature
ofthematerial
1
Inserttheplugofthetemperatureprobeintothesocketofthehost,
pressthepowerswitch,andinsertthemetalclawofthetemperature
probeintotheobjecttobemeasured,theinsertiondepthisnotless
than1/2ofitslength,andthetemperaturedataisreadonthehostin
abouttwominutes.Whenmeasuringthetemperatureofthemixture,
in order to avoid excessive impact between the temperature probe
andthehardobjectsinthemixtureandaffecttheservicelife,ametal
rod can be used to reserve a hole in the mixture, and then the
temperature probe can be inserted into the hole Temperature
measurement. The temperature probe should be wiped clean after
eachuse.
Measurethetemperatureofmassconcretewiththehostand
temperaturemeasuringline
2
After the construction temperature measurement plan is determined,
selec t a t emperatur e measu rement line with appropr iate lengt h
specifications according to the number and depth of the temperature
m e a s u r e m e n t p o i n t s , f o r e x a m p l e : t h e a c t u a l t e m p e r a t u r e
01 03
06
6、Batteryreplacement
1
measurement point depth is 0.2m~0.3m, and the 0.5m temperature
m e a s u r e m e n t l i n e c a n b e s e l e c t e d ; t h e a c t u a l t e m p e r a t u r e
measurement The point depth is 2.5m~2.8m, and the temperature
measurement line with a specification of 3m can be selected, and so
on. When pre-embedded, steel bars and other pieces can be used as
supports, and the temperature measurement line is tied to the support
according to the distance of the longitudinal temperature measurement
point. The temperature sensor and the support should be insulated.
When pouring the concrete, implant the support with the temperature
measuring wire into the concrete, the temperature sensor is at the
temperature measuring point, and the plug is left outside of the
concrete and covered with a plastic bag to avoid moisture and keep it
clean. For ease of operation, the length of the wire left outside should
be greater than 20cm. When measuring the temperature, press the
power switch of the main unit and insert the plug of the temperature
measurement line into the socket of the main unit, and the temperature
of the corresponding temperature measurement point can be displayed
on the main unit's display screen.
When pouring concrete, reserve temperature measurement holes
according to the winter construction temperature measurement
plan,placeatemperaturemeasurementwireineachhole,andleave
theplugofthetemperaturemeasurementwireoutsidetheholeand
coveritwithaplasticbagtoavoidmoistureandkeepitclean.When
measuringthetemperature,pressthepowerswitchofthemainunit
and insert the plug of the temperature measurement line into the
socket of the main unit, and the temperature of the corresponding
temperaturemeasurementpointcanbedisplayedonthemainunit's
display screen. After each stage of temperature measurement, the
temperature measurement line will be stored for future use. The
temperature measuring line can also be buried in the concrete for
one-timeuse.
Usethehostandtemperaturemeasuringlinetomeasuretheconcrete
temperatureduringwinterconstruction
3
Useofnighttemperaturereadingandlightingfunction
4
Whenusedatnightorinadarkenvironment,pressthehostbacklight
switch, the LCD screen can emit blue background light, making the
readingclearandeye-catching.Pressthelightswitch,thelightturns
on,whichisequivalenttoaflashlight.
WhenLOBATappearsintheupperleftcornerofthedisplayofthehost
or cannot be turne d on no rma lly, i t is us ual ly caused by in suffi cie nt
batteryvoltage,andanewbatteryneedstobereplaced.Themethod
is asfollows: Open the batterycompartment coverbehind the main
unit,takeoutthe oldbatteryfromthe batterycompartment, buckle
thenew battery,and then restorethebatterycompartment coverto
itsoriginalposition.
7、Batteryreplacement
When the host is not connected to the temperature measuring
probeorthetemperature measuringline,"-1"is displayedonthe
displayasthepreparationstate.
2Do not useexcessive force duringoperation.Holdthe plugfirmly
wheninsertingorunplugging theplugintooroutof thesocketof
thehost.
3Iftheplugorthesocketofthemainunitgetswetduetoaccidental
ingressofwater,pleasewipeitand dry itbefore using it toavoid
inaccuratetemperaturemeasurementresults.
4The instrument should be turned off in time after use, and the
battery should be removed when i t is not used for a long time to
avoiddamagetotheinstrument.
5Do not open the back cover of the main unit by yourself. Please
send it back to the manufacturer or agency when you need to
repairorcalibrateit.
8、Accessories
11copyofinstructionmanual
21copyofproductinspectioncertificate
31copyofproductwarrantycard
4Instrumentsets1piece
5Batteries
9、Options
0.5m、1m、1.5m、2m、2.5m、3m、
3.5m、4m、4.5m、5m
01
02
03
Optionalaccessories
Temperatureprobe
Optionalspecificationoftemperature
measuringline.
Otherspecificationsofthetemperature
measuringlinecanbecustomized.
0504 07
建筑电⼦测温仪
36.8
Switch Backlight
Lighting
Temperature range
Measurement Error
Environment Temperature
Shenzhen Noyafa Electronic Co., Ltd
Building Electronic Thermometer

Popular Thermometer manuals by other brands

RayTek Raynger ST 20 Pro manual

RayTek

RayTek Raynger ST 20 Pro manual

Welch Allyn SureTemp 679V Operating instructions manual

Welch Allyn

Welch Allyn SureTemp 679V Operating instructions manual

Vicks VNT275US owner's manual

Vicks

Vicks VNT275US owner's manual

EVE degree 10EAF9901 Get started

EVE

EVE degree 10EAF9901 Get started

Major tech MT691 instruction manual

Major tech

Major tech MT691 instruction manual

ARU Med AMT-505 user manual

ARU Med

ARU Med AMT-505 user manual

GREISINGER GMH 3210 user manual

GREISINGER

GREISINGER GMH 3210 user manual

Ebro TTX 200 Type T Core operating instructions

Ebro

Ebro TTX 200 Type T Core operating instructions

Emos S627BS manual

Emos

Emos S627BS manual

ECTHERM ECPIN ET180 quick start guide

ECTHERM

ECTHERM ECPIN ET180 quick start guide

Leadshine 307P operating instructions

Leadshine

Leadshine 307P operating instructions

Extech Instruments 421504 instruction manual

Extech Instruments

Extech Instruments 421504 instruction manual

Bartscher A292.044 instruction manual

Bartscher

Bartscher A292.044 instruction manual

Oakton WD-35426-60 instruction manual

Oakton

Oakton WD-35426-60 instruction manual

AccuMed AT2102 quick start guide

AccuMed

AccuMed AT2102 quick start guide

Citizen CT561C/F instruction manual

Citizen

Citizen CT561C/F instruction manual

Sanitas SFT 75 Instructions for use

Sanitas

Sanitas SFT 75 Instructions for use

Eurolec TH Series operating instructions

Eurolec

Eurolec TH Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.