manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. NOYAFA
  6. •
  7. Thermometer
  8. •
  9. NOYAFA NF-514 User manual

NOYAFA NF-514 User manual

Building Electronic Thermometer
02
NF-514
VER: V1
User Manual
建筑电⼦测温仪
36.8
Switch Backlight
Lighting
Temperature range
Measurement Error
Environment Temperature
Shenzhen Noyafa Electronic Co., Ltd
1、Overview
The instrument is Portable Building Electronic Thermometer is a
pr of es si o n a l tem p era tu re m eas u ri ng i ns tr um en t de v el op ed
acco rdin g to the construction characteristics of my country's
construction industry and relevant technical specifications. It can
displaythemeasuredtemperatureintuitively,accuratelyandquickly,
with good reliability, wide range of use and applications. Warm
operating environment, small size and light weight, easy to carry,
suitable for construction sites and field operations; mainly used for
const ruction, bu ildin g materials, water conservancy, electric power,
metallurgy, petrochemical, ports, roads and bridges, municipal and
otherbasicconstructionprojects.
2、ScopeOfApplication
The instrument is suitable for on-site construction temperature
measurement of various construction projects. It can be used with
temperature measurement probes to measure the temperature of
materialsandclinker,suchas:gas,liquid,fluid,mixtureandgranular
materials; and embedded temperature measurement line. It can be
used to measure the internal temperature of winter construction
concreteandmassconcrete.
3、Thecompositionandfunctionoftheinstrument
建筑电⼦测温仪
NF-514
36.8
Switch Backlight
Lighting
Temperature range
Measurement Error
Environment Temperature
Shenzhen Noyafa Electronic Co., Ltd
LCD
Power Switch
Power Switch
Backlight Switch
Temperature Probe
Temperatureprobe
Thetemperaturemeasuringprobeismadeofaplug,awire,ahandle
and a metal tube with an outer diameter of Φ5mm×220mm. The
frontendofthetubeispackagedwithatemperaturesensor,whichis
suitableformeasuringthetemperatureofmaterialsandclinker.
2
MainTester
The instrument is suitable for on-site construction temperature
measurement of various construction projects. It can be used with
temperature measurement probes to measure the temperature of
materialsandclinker,suchas:gas,liquid,fluid,mixtureandgranular
materials; and embedded temperature measurement line. It can be
used to measure the internal temperature of winter construction
concreteandmassconcrete.
1
Temperaturemeasurementline
3
Theembeddedtemperaturemeasuringlineismadeofaplug,awire
and a temperature sensor, which is suitable for measuring the
internal temperature of the concrete. Each temperature measuring
linecanmeasurethetemperatureatonepoint,andthetemperature
measuringpointcanbearrangedarbitrarilyduringtheconstruction.
In order to facilitatelayered temperaturemeasurement,the plugof
each temperature measurement cable has a label affixed with a
correspondinglengthspecification.
4、Themaintechnicalindicators
Temperaturemeasurementrange:-30°C~150°C
Temperaturemeasurementerror:≤±0.5°C
Operatingenvironmenttemperature:20°C~50°℃
Displaymode:3-digitLCDscreen
Powersupply:9Vlaminatedbattery
Weight:200g
Hostvolume:135mm×72mm×32mm
Resolution:0.1°C
1
2
3
4
5
6
7
8
5、Usemethod
Usethehostandtemperatureprobetomeasurethetemperature
ofthematerial
1
Inserttheplugofthetemperatureprobeintothesocketofthehost,
pressthepowerswitch,andinsertthemetalclawofthetemperature
probeintotheobjecttobemeasured,theinsertiondepthisnotless
than1/2ofitslength,andthetemperaturedataisreadonthehostin
abouttwominutes.Whenmeasuringthetemperatureofthemixture,
in order to avoid excessive impact between the temperature probe
andthehardobjectsinthemixtureandaffecttheservicelife,ametal
rod can be used to reserve a hole in the mixture, and then the
temperature probe can be inserted into the hole Temperature
measurement. The temperature probe should be wiped clean after
eachuse.
Measurethetemperatureofmassconcretewiththehostand
temperaturemeasuringline
2
After the construction temperature measurement plan is determined,
selec t a t emperatur e measu rement line with appropr iate lengt h
specifications according to the number and depth of the temperature
m e a s u r e m e n t p o i n t s , f o r e x a m p l e : t h e a c t u a l t e m p e r a t u r e
01 03
06
6、Batteryreplacement
1
measurement point depth is 0.2m~0.3m, and the 0.5m temperature
m e a s u r e m e n t l i n e c a n b e s e l e c t e d ; t h e a c t u a l t e m p e r a t u r e
measurement The point depth is 2.5m~2.8m, and the temperature
measurement line with a specification of 3m can be selected, and so
on. When pre-embedded, steel bars and other pieces can be used as
supports, and the temperature measurement line is tied to the support
according to the distance of the longitudinal temperature measurement
point. The temperature sensor and the support should be insulated.
When pouring the concrete, implant the support with the temperature
measuring wire into the concrete, the temperature sensor is at the
temperature measuring point, and the plug is left outside of the
concrete and covered with a plastic bag to avoid moisture and keep it
clean. For ease of operation, the length of the wire left outside should
be greater than 20cm. When measuring the temperature, press the
power switch of the main unit and insert the plug of the temperature
measurement line into the socket of the main unit, and the temperature
of the corresponding temperature measurement point can be displayed
on the main unit's display screen.
When pouring concrete, reserve temperature measurement holes
according to the winter construction temperature measurement
plan,placeatemperaturemeasurementwireineachhole,andleave
theplugofthetemperaturemeasurementwireoutsidetheholeand
coveritwithaplasticbagtoavoidmoistureandkeepitclean.When
measuringthetemperature,pressthepowerswitchofthemainunit
and insert the plug of the temperature measurement line into the
socket of the main unit, and the temperature of the corresponding
temperaturemeasurementpointcanbedisplayedonthemainunit's
display screen. After each stage of temperature measurement, the
temperature measurement line will be stored for future use. The
temperature measuring line can also be buried in the concrete for
one-timeuse.
Usethehostandtemperaturemeasuringlinetomeasuretheconcrete
temperatureduringwinterconstruction
3
Useofnighttemperaturereadingandlightingfunction
4
Whenusedatnightorinadarkenvironment,pressthehostbacklight
switch, the LCD screen can emit blue background light, making the
readingclearandeye-catching.Pressthelightswitch,thelightturns
on,whichisequivalenttoaflashlight.
WhenLOBATappearsintheupperleftcornerofthedisplayofthehost
or cannot be turne d on no rma lly, i t is us ual ly caused by in suffi cie nt
batteryvoltage,andanewbatteryneedstobereplaced.Themethod
is asfollows: Open the batterycompartment coverbehind the main
unit,takeoutthe oldbatteryfromthe batterycompartment, buckle
thenew battery,and then restorethebatterycompartment coverto
itsoriginalposition.
7、Batteryreplacement
When the host is not connected to the temperature measuring
probeorthetemperature measuringline,"-1"is displayedonthe
displayasthepreparationstate.
2Do not useexcessive force duringoperation.Holdthe plugfirmly
wheninsertingorunplugging theplugintooroutof thesocketof
thehost.
3Iftheplugorthesocketofthemainunitgetswetduetoaccidental
ingressofwater,pleasewipeitand dry itbefore using it toavoid
inaccuratetemperaturemeasurementresults.
4The instrument should be turned off in time after use, and the
battery should be removed when i t is not used for a long time to
avoiddamagetotheinstrument.
5Do not open the back cover of the main unit by yourself. Please
send it back to the manufacturer or agency when you need to
repairorcalibrateit.
8、Accessories
11copyofinstructionmanual
21copyofproductinspectioncertificate
31copyofproductwarrantycard
4Instrumentsets1piece
5Batteries
9、Options
0.5m、1m、1.5m、2m、2.5m、3m、
3.5m、4m、4.5m、5m
01
02
03
Optionalaccessories
Temperatureprobe
Optionalspecificationoftemperature
measuringline.
Otherspecificationsofthetemperature
measuringlinecanbecustomized.
0504 07
建筑电⼦测温仪
36.8
Switch Backlight
Lighting
Temperature range
Measurement Error
Environment Temperature
Shenzhen Noyafa Electronic Co., Ltd
Building Electronic Thermometer

Popular Thermometer manuals by other brands

Tecnimed Visiofocus Smart 06470 operating instructions

Tecnimed

Tecnimed Visiofocus Smart 06470 operating instructions

Renkforce 1342394 operating instructions

Renkforce

Renkforce 1342394 operating instructions

2measure 185110 Operation manual

2measure

2measure 185110 Operation manual

Taylor OMG 808 user manual

Taylor

Taylor OMG 808 user manual

Exergen TemporalScanner TAT-5000 Reference manual

Exergen

Exergen TemporalScanner TAT-5000 Reference manual

Speedtech Instruments EW-1 user manual

Speedtech Instruments

Speedtech Instruments EW-1 user manual

Beurer FT 55 operating instructions

Beurer

Beurer FT 55 operating instructions

Welby 90944-14 instructions

Welby

Welby 90944-14 instructions

Oregon Scientific RMR112 user manual

Oregon Scientific

Oregon Scientific RMR112 user manual

Extech Instruments RH200W-T user manual

Extech Instruments

Extech Instruments RH200W-T user manual

Omega Engineering HH801B operating instructions

Omega Engineering

Omega Engineering HH801B operating instructions

PANCONTROL PAN IR-T380 manual

PANCONTROL

PANCONTROL PAN IR-T380 manual

Omega DP1001M user guide

Omega

Omega DP1001M user guide

VISIOMED THERMOSOFT VM-DS400 user manual

VISIOMED

VISIOMED THERMOSOFT VM-DS400 user manual

RayTek Raynger Series 3i Plus operating instructions

RayTek

RayTek Raynger Series 3i Plus operating instructions

TFA 30.3037.01.IT instruction manual

TFA

TFA 30.3037.01.IT instruction manual

ThermoWorks CF-IR operating instructions

ThermoWorks

ThermoWorks CF-IR operating instructions

Menuett 943-109 User instructions

Menuett

Menuett 943-109 User instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.