NR SPM05 Series User manual

V1.0
1
SPM05 Series
ZigBee Wireless PIR Motion Detector User Manual
2. Specifications
3. Installation
Network protocol
Compliant IEEE 802.15.4 ZigBee
2007/PRO
Frequency
ISM 2.4 GHz
Channel
16 (11~26)
RF output power
0 dBm
Receiver sensitivity
-95 dBm
Communication range
Up to 100m / 328 ft
Working voltage
3V DC (CR123A battery) (SPM05)
5V DC (US-type AC adapter) (SPM05-
H1)
Antenna
PCB Antenna
Configure parameters
Baud rate, Pan ID, RF Channel
adjustable
Network supports
Star , Tree , Mesh
Auto reconnection
yes (Zero Data Loss technology)
Working Temperature/
Humidity
0˚C~50˚C / 32˚F~122˚F, 0~75% RH
Storage Temperature
-20˚C~60˚C / -4˚F~140˚F
Indoor White Light
Resistance
More than 9000LUX
Max. Current
Consumption
Tx: 35 mA ; Sleep: 1.3 mA
Max. Coverage Area
9m / 23ft (12m / 46ft max.) // 100度
DIP
Switch
Tamper
Switch
Power Cord (SPM05-H1)
Poten-
tiometer
S1 Button
LED Infrared Detector
Mounting Base Battery
Compartment
(SPM05)
Powering ON the Detector
1. SPM05: Install or replace battery.
2. SPM05-H1: Plug AC adapter to live AC mains.
Installation Location
1. Height range: 2.0 to 2.5M
2. Mounting base adjustment angle:
45 degrees
Package Contents
1. Detector, moun g package (moun g
base, screw x 2, wall plugx 2)
AC to 5VDC adapter (SPM05-H1)
2.
MAC+SN
Back Lid
Latch
Back Lid
Securing Screw
Back Lid
Alarm Indication
Alarm LED ON for several seconds
Dimensions
(LxWxH)
95 x 64 x 49 mm / 3.74 x 2.52 x 1.93 in
Weight
92 g / 3.25 oz (w/ battery) ;
59 g / 2.08 oz (w/o battery)
Opening/Closing Back Lid
1. Loosen back lid screw. Use flat-tip tool to push
in back lid latch, then remove back lid.
2. After internal settings or battery replacement,
replace and close back lid, then secure back lid
screw.
Side View
Motion Detection Zone –Top View
1. Introduction
SPM05 series (WZB-SPM05, WZB-SPM05-H1)
wireless PIR motion detector detects human body
movement with digital processing and sophisticated
radio communication protocol to minimize false
alarms and maximize stability. The detector auto-
tests and reports status periodically for full
supervision via Sentrol Cloud. Built-in tamper switch
triggers alarm upon any tamper activity.
SPM05 Series have following model options (may be
commonly referred in this manual as SPM05):
WZB-SPM05 –Battery-powered
WZB-SPM05-H1 –AC-powered (US type plug)

V1.0
2
4. Installation Notice
5. Pet-immunity Guidebook
7. Tamper Switch Functions
Tamper
Switch
SPM05 Series User Manual
The top of the
detecting area is
the non-pet-
immunity area
Prevent direct to
the places where
the pets can
climb up
The pet is
smaller than
20kgs
The pet is
smaller than
15kgs
The installation
height of 2.2m to
2.4m is available
pet-immunity
height
6 Setting IR Detector Time Interval, LED Mode, and Pulse Count
②Setting LED Mode and Pulse Count:
①Setting IR Detector Time Interval:
DIP SW
Setting
Mode
Descriptions
1
OFF
LED
disabled
LED will not light after detecting an
activity pulse or triggering an alarm.
ON*
LED
enabled
LED will light (for 1 sec) after detecting
an activity pulse or triggering an alarm.
3
OFF
1-pulse
Triggers the alarm after detecting 1
activity pulse.
ON*
2-pulse
Triggers the alarm after detecting 2
activity pulses.
Potentio-
meter
Gridline
1
2
3
4
5
6
7
8
9
10*
IR
Detector
Time
Interval
120s
60s
20s
10s
5s
*: Factory default settings
①②
DIP switches #1 & #3 set the LED mode
and the alarm-triggering pulse count.
Higher pulse count reduces alarms
triggered but can lower the chance of a
false alarm.
The potentiometer sets IR detector
time interval (e.g. 5s = check detector every 5 seconds).
Turn the potentiometer to align with the reference point,
then turn the potentiometer to the desired gridline for
the desired IR detector time interval.
Change will take effect after triggering an alarm or tamper
switch.
1
2
3
4
5
6
7
8
9
10 Reference Point
*:
Factory
default
settings
DIP Switches
Potentiometer
While the detector is powered on, the tamper switch works as follows:
a) After closing the lid, the tamper switch is continuously pressed by the
spring, engaging the anti-tamper protection mode.
b) If anybody opens the lid, the tamper switch will be released (triggered),
triggering the alarm.

V1.0
3
8. Walk Test in Coverage Area:
10. Joining Detector to Parent Device’s IoT Network
1. Ensure parent device is powered on.
2. Ensure SPM05 is powered on and is in Ready to Join status.
3. Set parent device to Permit Join status (please refer to parent device’s user manual).
4. SPM05’s Green LED will flash 3 times (Successfully Joined), then Green LED flashes every 60
or 2 seconds (Normal Operations).
If SPM05’s Green LED does not flash every 60 or 2 seconds, then ZigBee Reset SPM05 (push S1
button 3 times within 1.5 seconds). Check and deal with any other 2.4 GHz device that may
interferere ZigBee connection. Then repeat above procedures.
If SPM05 has joined parent device but is showing Disconnected status (Green LED not flashing or
flashing twice per 5 seconds), ensure parent device is powered on. If parent device functions
normally, ensure that SPM05 and parent device are within communication range of each other.
A router may be needed to extend communication range.
9. LED Indications and S1 Button Actions
Status
LED Status (SPM05)
LED Status (SPM05-H1)
S1 Button
Actions
Functions
Ready to Join
Green LED flash in every 15
seconds
Green LED flash in every 5
seconds
-
Ready to join network of
parent device (coordinator,
gateway, or router)
Successfully
Joined
Green LED quick flash 3
times
Green LED quick flash 3
times
-
Joined network of parent
device
Normal
Operations
Green LED flash in every 60
seconds
Green LED flash in every 2
seconds
-
Joined network of parent
device and functioning
normally
Disconnected
No flash
Green LED flash twice in
every 5 seconds
-
Joined network, but
unable to find any parent
device of the network
ZigBee Reset
Red & Green LED light up 2
seconds, then Green LED
quick flash once, turn to flash
in every 15 seconds
Red & Green LED light up 2
seconds, then Green LED
quick flash once, turn to flash
in every 5 seconds
Push and
hold S1
button for
5 seconds
Reset to factory default,
remove all ZigBee
network linkages
Removing
Successful: Red LED quick
flash then, back to flash in
every 15 seconds
Failure : Red LED quick
flash for 30 seconds, then,
back to flash in every 60
seconds
Successful: Red LED quick
flash then, back to flash in
every 5 seconds
Failure : Red LED quick
flash for 30 seconds, then,
back to flash in every 2
seconds
Push S1
button 3 times
within 1.5
seconds
Being removed from the
network of the parent
device
SPM05 Series User Manual
Not recommended for
detecting perpendicular movement
Recommended for
detecting parallel movement

V1.0
4
© 2016 Nietzsche Enterprise Co., Ltd. All rights reserved.
Nietzsche Enterprise reserves the right to make changes and improvements to its products without notice.
10. Using DataView/QuickView for Detector Real-time Monitoring
Requirements:
•ZigBee parent device such as coordinator (WZB-01USBC,WZB-02485C, WZB-05ET, etc.) or
router (WZB-01USBR,WZB-02485R, etc.)
•Windows PC that can install DataView/QuickView
1. Ensure SPM05 has joined parent device’s IoT network and is in Normal Operations status
(please refer to “Joining Detector to Parent Device’s IoT Network” section).
2. Install and launch DataView/QuickView on Windows PC。Ensure DataView/QuickView can
freely communicate with parent device and can successfully show your SPM05’s real-time
status.
3. Let the test person walk in front of the detector. DataView/QuickView should show real-time
motion detection.
Please refer to the latest DataView/QuickView user manual or online tutorials for more details.
11. Using Sentrol Cloud to Interconnect Detector with IoT Devices
Requirements:
•G07 Smart Wireless Gateway Base Station
•Computer or smart device with a browser and/or Sentrol Cloud app installed
1. Ensure SPM05 has joined parent device’s IoT network and is in Normal Operations status
(please refer to “Joining Detector to Parent Device’s IoT Network” section).
2. If you are using a smart device (smartphone, tablet, etc.), please install Sentrol Cloud app on
your smart device.
3. Ensure you have a valid Sentrol Cloud account registering your gateway (regarding acccount
registration, please follow instructions on http://www.sentrolcloud.com website or Sentrol
Cloud app).
4. Launch http://www.sentrolcloud.com website or Sentrol Cloud app, then login Sentrol Cloud
with your Sentrol Cloud account.
5. After establishing an appropriate profile, your detector will send real-time data to Sentrol
Cloud upon motion detection, then Sentrol Cloud will dispatch real-time events accordingly.
If you have interconnected the detector with other end device(s), the interconnected end
device(s) will execute your defined actions.
6. Let the test person walk in front of the detector. Sentrol Cloud should show real-time motion
detection, and your interconnected end device(s) should execute yoru defined actions.
SPM05 Series User Manual
Contact Information: Email: njŝŐďĞĞŶŚƌΛƐŚŽƉ, Website: ǁǁǁƐŚŽƉͲǁŝĨŝĐŽŵǁŝƌĞůĞƐƐͲƐĞŶƐŽƌƐ