Configuring the device parameters
Enter the DEVICE SETTINGS menu and select the required configuration as described in the
following table.
Option Action
General configuration options
Alarm LED Define whether the alarm LED indication will be activated.
Optional settings: LED ON (default) and LED OFF.
Event counter Define whether an alarm will be activated upon continued motion (low
sensitivity) or upon a single alarm event (high sensitivity)..
Optional settings: LOW sensitivity (default) and HIGH sensitivity.
Disarm activity Define whether the device is active when the system is disarmed.
Optional settings: NOT Active (default), no delay, 5 s delay, 15 s delay, 30 s
delay, 1 min delay, 2 min delay, 5 min delay, 10 min delay, 20 min delay and
60 min delay.
AC monitoring Determine whether the device is connected to AC power. When enabled, the
device reports power failure and power restore events.
Optional settings: Disabled (default) and Enabled.
AC LED behavior Define whether the LED lights green when connected to AC power.
Optional settings: Always OFF (default) and Match AC.
Temperature
reporting
Define the device temperature reporting mechanism.
Optional settings: Disabled (default). For further configuration options, refer to
the control panel installation guide.
Camera configuration options
Image color Determine whether the image will be in black and white or color.
Optional settings: Black & White (default) and Color.
Alarm image
resolution
Set the resolution of an image taken during an alarm.
Optional settings: VGA: 640 x 480, QVGA: 320 x 240 (default), QQVGA: 160 x 120
On-demand
image
resolution
Set the resolution of an image taken for an on-demand image request.
Optional settings: HD: 1280 x 720, VGA: 640 x 480, QVGA: 320 x 240 (default),
QQVGA: 160 x 120
Image quality Set the quality of an image taken during an alarm.
Optional settings: Low (default), High.
Image
brightness
Set the brightness of the image. Normal (default) is recommended for most
conditions.
Optional settings: Normal (default), -3 (lowest), -2, -1, +1, +2, and +3 (highest).
Image contrast Set the contrast of the image. Normal (default) is recommended for most
conditions.
Optional settings: Normal (default), -3 lowest), -2, -1, +1, +2, and +3 (highest).
Microphone
settings
Determine whether to activate the microphone. When set to enable, the
microphone records sound only during image capturing.
Optional settings: Disable (default) and Enable.
3NEXT CAM PG+ Motion Detector with Integrated Camera Installation Guide
D-308840 NEXT CAM PG+ Rev. 0