manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. NRD
  6. •
  7. Air Ionizer
  8. •
  9. NRD P-2060 User manual

NRD P-2060 User manual

Other NRD Air Ionizer manuals

NRD Nuclestat P-2001 Instruction manual

NRD

NRD Nuclestat P-2001 Instruction manual

NRD Nuclecel P-2063 User manual

NRD

NRD Nuclecel P-2063 User manual

Popular Air Ionizer manuals by other brands

ESD SYSTEMS 94000 Operation installation and maintenance

ESD SYSTEMS

ESD SYSTEMS 94000 Operation installation and maintenance

TEQOYA TIP9 user guide

TEQOYA

TEQOYA TIP9 user guide

SCS 963E user guide

SCS

SCS 963E user guide

Vessel Stat-Clean F-6BF-E instruction manual

Vessel

Vessel Stat-Clean F-6BF-E instruction manual

Desco SCS 992X-0350 instruction manual

Desco

Desco SCS 992X-0350 instruction manual

SMC Networks IZN10E Series Operation manual

SMC Networks

SMC Networks IZN10E Series Operation manual

BüRGE Ion Dome manual

BüRGE

BüRGE Ion Dome manual

Fraser NEOS 30 OEM manual

Fraser

Fraser NEOS 30 OEM manual

A&D AX-ION-25 instruction manual

A&D

A&D AX-ION-25 instruction manual

greenfan 1600-01 installation instructions

greenfan

greenfan 1600-01 installation instructions

Plasma Air PA600 Series Installation, operation & maintenance manual

Plasma Air

Plasma Air PA600 Series Installation, operation & maintenance manual

SMC Networks IZS42 manual

SMC Networks

SMC Networks IZS42 manual

Desco 50692 Installation, operation and maintenance manual

Desco

Desco 50692 Installation, operation and maintenance manual

UFO UFO-ECH/10 user manual

UFO

UFO UFO-ECH/10 user manual

Jonix steel 1C Use and maintenance manual

Jonix

Jonix steel 1C Use and maintenance manual

Panasonic TK-AS66-ZEX instruction manual

Panasonic

Panasonic TK-AS66-ZEX instruction manual

Real Spirit AQUA-IONIZER PRO ionHealth Pro owner's manual

Real Spirit

Real Spirit AQUA-IONIZER PRO ionHealth Pro owner's manual

SMC Networks IZT41 Series Operation manual

SMC Networks

SMC Networks IZT41 Series Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

NRD, LLC / 2937 Alt Boulevard / Grand Island, NY 14072
PHONE 716 773 7634 / FAX 716 773 7744 / EMAIL sales@nrdllc.com / WEB www.nrdllc.com
NRD Asia Pte. Ltd
PHONE +65 6679 1707 / EMAIL sales@NRDasia.com / WEB www.nrdllc.com
INST2060 – 12/22
Instruction Manual
for
P-2060 Ionizer & Accessories
CONTENTS
1.0 Model P-2060 Ionizer Page 1
2.0 Accessories Page 2
2.1 Model 4065 Fan
3.0 Troubleshooting Page 3
NRD, LLC / 2937 Alt Boulevard / Grand Island, NY 14072
PHONE 716 773 7634 / FAX 716 773 7744 / EMAIL sales@nrdllc.com / WEB www.nrdllc.com
NRD Asia Pte. Ltd
PHONE +65 6679 1707 / EMAIL sales@NRDasia.com / WEB www.nrdllc.com
INST2060 – 12/22
1.0 P-2060 Ionizer
The P-2060 Ionizer is used to neutralize static electrical charges in static sensitive operations.
The Ionizer is normally placed in an atmospheric pressure air stream so that the airflow delivers
ions generated by the Ionizer to the work area. Charged parts that are placed in close proximity
to the ion cell can also be effectively neutralized without the need of air movement.
1.1 Installation & Operation
A. The P-2060 is to be installed in a customer supplied mounting fixture. Mount the P-2060
using the two 0.14” diameter mounting holes on the front plate. Locate in a suitable air
stream to deliver the ions to the area to be neutralized.
Do not alter the P-2060 in any way that may compromise the
integrity of the source. Do not drill holes, grind or file, tap
holes, etc. to the P-2060.
B. Supply air movement through the ionizer to move the ions to the charged part. A
fan or compressed air/nitrogen can be used. For parts that can be placed in close
proximity (1”) from the grill openings, air movement may not be needed to
effectively neutralize the charged part.
NRD, LLC / 2937 Alt Boulevard / Grand Island, NY 14072
PHONE 716 773 7634 / FAX 716 773 7744 / EMAIL sales@nrdllc.com / WEB www.nrdllc.com
NRD Asia Pte. Ltd
PHONE +65 6679 1707 / EMAIL sales@NRDasia.com / WEB www.nrdllc.com
INST2060 – 12/22
2.0 Accessories
2.1 Model 4065 Staticmaster
High-Output Ionizing Fan
The Model 4065 is used to create airflow through the Ionizer (model P-2060). This system
delivers a high volume of ionized air to reduce charge on parts. The Fan is mounted on a swivel
base and can be placed on a flat surface or bolted to a rigid surface.
Procedure to install a new P-2060 Ionizer:
A. Unplug AC adapter from the electrical outlet.
B. Remove front cover by pressing down on the tab and pulling the cover out and up.
C. Remove two (2) thumb screws and washers.
D. Slide the model P-2060 ion cell into opening in middle plate; make sure holes align with the
holes for the thumb screws.
E. Secure model P-2060 ion cell in place with the two (2) thumb screws and washers removed
in step 3.
F. Replace front cover.
G. Connect the AC adapter to a 120 VAC, 60 Hz electrical outlet.
NRD, LLC / 2937 Alt Boulevard / Grand Island, NY 14072
PHONE 716 773 7634 / FAX 716 773 7744 / EMAIL sales@nrdllc.com / WEB www.nrdllc.com
NRD Asia Pte. Ltd
PHONE +65 6679 1707 / EMAIL sales@NRDasia.com / WEB www.nrdllc.com
INST2060 – 12/22
Maintenance
•The only maintenance required is the annual replacement of the Ionizer to ensure maximum
effectiveness of the ionizer. It is required to return the expired device to NRD for proper
disposal.
•Calibration is not required.
3.0 Trouble Shooting Guide
Symptom Probable Cause Corrective Action
1.
Static charges are not
eliminated
Ion cell may be out of date and
need replacement.
Possible oil contamination of ion
cell.
Ions generated are being
recombined before they reach the
charged surface.
Call NRD for Ion Cell
replacement.
Return cell to NRD for
evaluation. Do not attempt to
clean the device.
Position the fan closer to the
charged part.
2. Fan does not turn on
No power.
Blown fuse internal to fan.
Check outlet and breakers.
Check for visible damage to
power cord. Return fan to NRD
for evaluation.
Limited Warranty
NRD expressly warrants that for a period of one (1) year
from the time of purchase, the
item will be free of defects in
material (parts) and workmanship (labor). Within the
warranty period, the
item
will be tested, repaired, or replaced
at discretion of N
RD, free of charge. Any item under
warranty should be shipped prepaid to the NRD factory.
Call Customer Service at (716) 773
-7634 for a Return
Authorization number and shipping instructions. Include a
copy of your original packing slip, invoice, or other proof of
purchase date.
If the
item is out of warranty, NRD LLC will quote repair
charges
necessary to bring your item up to factory standards.
Warranty Exclusions
The forgoing express warranty is made in lieu of all other
product warranties, expresse
d and implied, including
merchantability and fitness for a particular purpose that is
specifically disclaimed. The express warranty will not apply
to defects or damage due to accidents, neglect, misuse,
alterations, operator error, or failure to properly
maintain,
clean or repair products.
Limit of Liability
The user shall determine the suitability of the product for
their intended use, and the user assumes all risk and liability
whatsoever in connection therein.