Instruction Manual
for
P-2063 Ionizer & Accessories
CONTENTS
1.0 Model P-2063 Ionizer Page 1
2.0 Accessories Page 2
2.1 Model 4064 Fan
2.2 Model 4070 Overhead Ionizing Fan
3.0 Troubleshooting Page 3
NRD USA / 2937 Alt Boulevard / PO Box 310 / Grand Island, NY 14072-0310
PHONE 716 773 7634 / FAX 716 773 7744 / EMAIL [email protected] / WEB www.nrdllc.com
NRD Asia Pte. Ltd / 114 Lavender Street #08-90 CT Hub 2 Singapore 338729
PHONE +65 6679 1707 / EMAIL [email protected] / WEB www.nrdllc.com
INST2063 – 2/19
1.0 P-2063 Ionizer
Part number: P-2063-1000 (Al) Part number: P-2063-1200 (Al)/P-2063-2200 (SST)
Used on 4064/4070
The P-2063 Ionizer is used to neutralize static electrical charges in static sensitive operations.
The Ionizer is normally placed in an atmospheric pressure air stream so that the airflow delivers
ions generated by the Ionizer to the work area. Charged parts that are placed in close proximity
to the ion cell can also be effectively neutralized without the need of air movement.
1.1 Installation & Operation
A. One common method to install the P-2063 Ionizer is by using spring clips that
will snap on to the posts of the Ionizer. The spring clips can be attached to a
mounting base. There are other methods to mounting the cell, but cannot involve
modifying the Ionizer.
Do not alter the P-2063 in any way that may compromise the
integrity of the source. Do not drill holes, grind or file, tap
holes, etc. to the P-2063.
B. Supply air movement through the ionizer to move the ions to the charged part. A
fan or compressed air/nitrogen can be used. For parts that can be placed in close
proximity (1”) from the grill openings, air movement may not be needed to
effectively neutralize the charged part.
NRD USA / 2937 Alt Boulevard / PO Box 310 / Grand Island, NY 14072-0310
PHONE 716 773 7634 / FAX 716 773 7744 / EMAIL [email protected] / WEB www.nrdllc.com
NRD Asia Pte. Ltd / 114 Lavender Street #08-90 CT Hub 2 Singapore 338729
PHONE +65 6679 1707 / EMAIL [email protected] / WEB www.nrdllc.com
INST2063 – 2/19
2.0 Accessories
2.1 Model 4064 Staticmaster Fan
The Model 4064 is used to create airflow through the Ionizer (model P-2063). This system
delivers a high volume of ionized air to reduce charge on parts. The Fan is mounted on a swivel
base and can be placed on a flat surface or bolted to a rigid surface.
2.2 Model 4070
Alpha Staticmaster® Overhead Ionizing Fan
When using the Model 4070, the ideal neutralization time for the target is when it’s placed 18” to
36” directly under the ionizing fan and increases as the distance increases
Procedure to install a new P-2063 Ionizer:
1. Unplug AC power cord from the electrical outlet.
2. Align and insert ¼ turn fastener, on P-2063 ion cell, into ¼ turn receptacle, in 4064/4070
housing, and turn clockwise to secure in place.
3. Plug AC power cord into an electrical outlet.
NRD USA / 2937 Alt Boulevard / PO Box 310 / Grand Island, NY 14072-0310
PHONE 716 773 7634 / FAX 716 773 7744 / EMAIL [email protected] / WEB www.nrdllc.com
NRD Asia Pte. Ltd / 114 Lavender Street #08-90 CT Hub 2 Singapore 338729
PHONE +65 6679 1707 / EMAIL [email protected] / WEB www.nrdllc.com
INST2063 – 2/19
Maintenance
 The only maintenance required is the annual replacement of the Ionizer to ensure maximum
effectiveness of the ionizer. It is required to return the expired device to NRD for proper
disposal.
 Calibration is not required.
3.0 Trouble Shooting Guide
Symptom Probable Cause Corrective Action
1. Static charges are not
eliminated
Ion cell may be out of date and
need replacement.
Possible oil contamination of ion
cell.
Ions generated are being
recombined before they reach the
charged surface.
Call NRD for Ion Cell
replacement.
Return cell to NRD for
evaluation. Do not attempt to
clean the device.
Position the fan closer to the
charged part.
2. Fan does not turn on
No power.
Blown fuse internal to fan.
Check outlet and breakers.
Check for visible damage to
power cord. Return fan to NRD
for evaluation.

Other NRD Other manuals

NRD P-2062 User manual

NRD

NRD P-2062 User manual

NRD Staticmaster P-2001 Technical Document

NRD

NRD Staticmaster P-2001 Technical Document

NRD Staticmaster P-2035 General instructions

NRD

NRD Staticmaster P-2035 General instructions

NRD Staticmaster P-2021 Series General instructions

NRD

NRD Staticmaster P-2021 Series General instructions

NRD Alphaboost AB-TC-1 Owner's manual

NRD

NRD Alphaboost AB-TC-1 Owner's manual

Popular Other manuals by other brands

Greenheck AMD-42 Installation, operation and maintenance instructions

Greenheck

Greenheck AMD-42 Installation, operation and maintenance instructions

Kollercraft AP150 Instructions for use

Kollercraft

Kollercraft AP150 Instructions for use

DUSCHY 5033 Assembly guide

DUSCHY

DUSCHY 5033 Assembly guide

Augen Prizm user manual

Augen

Augen Prizm user manual

Dover OPW 12VW-AX Series manual

Dover

Dover OPW 12VW-AX Series manual

Heathkit HD-1410 instruction manual

Heathkit

Heathkit HD-1410 instruction manual

Panasonic PVD4742 - DVD/VCR DECK operating instructions

Panasonic

Panasonic PVD4742 - DVD/VCR DECK operating instructions

Hagen FLUVAL 05 Series manual

Hagen

Hagen FLUVAL 05 Series manual

OYPLA Home 4067 user manual

OYPLA Home

OYPLA Home 4067 user manual

switel M160 operating instructions

switel

switel M160 operating instructions

OMB Guitars OMB Upgrade Kit user guide

OMB Guitars

OMB Guitars OMB Upgrade Kit user guide

VST GREEN MACHINE  VST-GM-CS2-101 Installation, Operation, Maintenance, & Troubleshooting Manual

VST

VST GREEN MACHINE VST-GM-CS2-101 Installation, Operation, Maintenance, & Troubleshooting Manual

GFB EX50 installation instructions

GFB

GFB EX50 installation instructions

Storch Hot Box 240 Translation of the original instruction

Storch

Storch Hot Box 240 Translation of the original instruction

Ebro EBI 20-T1 instruction manual

Ebro

Ebro EBI 20-T1 instruction manual

Carl Martin Red Repeat 2016 manual

Carl Martin

Carl Martin Red Repeat 2016 manual

Universal Electronics REMOTE EXTENDER Safety precautions

Universal Electronics

Universal Electronics REMOTE EXTENDER Safety precautions

Aquadistri SuperFish Aqua 20 Manual and warranty

Aquadistri

Aquadistri SuperFish Aqua 20 Manual and warranty

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.