Installation and Maintenance GENIE 12V & 230V Universal Surface Mounted Fans
Figure 6.
Mounting bracket for
semi-recessed applications.
Optional Extra
Part No. 770982
Window 4mm to 32mm thick.
Cut 125mm hole for fan.
Electrical cable passed through
the inner gasket and fed into case.
Unit case.
Spacers where
required.
Approximately
150mm of cable
for final wiring.
Inner gasket,
spigot moulding
locates in window
aperture.
Top three shutter
blades temporarily
removed during
installation.
Outer shutter frame.
Outer gasket,
spigot moulding
locates in window
aperture.
Figure 8.
Figure 7.
Front view
10mm
Pullcord
(when used)
70mm
.
NUAIRE
Figure 9.
The hole in the glass should be
125mm dia. Centre 10mm to the
left of the unit centreline and
70mm from the top of the unit.
Isolation - Before commencing work
make sure that the unit is electrically isolated
from the mains and switched live supply.
Semi-Recessed Mounting (cont).
Important note: Remove the shutters
from the spigot if you are mounting
the Genie in the ceiling.
1. Prepare an opening 184mm x 213mm.
This will allow sufficient clearance
(approx. 5 to 10mm) all around the
unit to accept the fixing bracket
(optional). Note. Do not exceed these
dimensions, as an aperture larger than
208mm x 238mm will not be covered
by the finishing plate.
It is assumed that a solid, non-reverberant mounting position has
been selected and the necessary compatible ductwork is already
installed.
2. Position the mounting bracket (Fig.7)
in the previously prepared aperture so
that the ends of the bracket are flush
with the surface of the wall. Secure the
bracket with suitable fixings (by others)
see Fig. 5. Note: Fit finishing plate to fan
before securing to bracket.
Note: the remaining installation
procedures for Semi-Recessed
Mounting are as Surface Mounting
description.
Window Mounting
WINKIT Parts checklist
The WINKIT contains the following parts. Make sure you have all
the parts present before commencing installation.
1 off Outer Shutter frame assembly 011372 and 040547
1 off Outer gasket 540846
1 off Inner gasket 540845
3 off 5mm spacers 050149
3 off M4 x 12 Screws 680268
3 off M4 x 20 Screws 680087
3 off M4 x 30 Screws 680264
3 off M4 x 40 Screws 680265
The window mounting kit is designed for mounting the unit into
windows 4mm to 32mm thick using a 125mm dia hole. (See figure 9).
1. Employ a qualified glazier to cut a hole 125mm dia in the glass or,
alternatively, replace your window with new glass incorporating a
precut hole (Fig. 8).
2. The outer assembly consists a four bladed outlet shutter
complete with clamping plate and an outer rubber gasket moulding.
The gasket incorporates a moulded spigot which is designed to
locate inside the 125mm dia hole in the glass.
Pop-out the top three plastic shutter blades from the frame and
retain for replacement later. Position the assembly on the outside
of the glass. If only one person is installing the fan it may be helpful
to tape the assembly to the outside glass at this stage during
installation as all fixings and assembly are completed from inside
3. Working from inside the room with the inner gasket and unit
casing. Run suitable cable through the inner gasket (Holes are
provided top and bottom). Feed the cable through the access hole in
the back of the case. Allow approximately 150mm of cable to
protrude into the case. (See Fig.8). Position this inner gasket and
case assembly over the hole in the glass and locate the inner
gasket moulded spigot in the aperture.
4. Select appropriate screws and spacers from the four sets of
screws and three spacers supplied for mounting into different
thicknesses of glass, see table below.
Table 1 Glass/Screw selection
Window thickness Screw size
4mm - 6mm M4 x 12
7mm - 11mm M4 x 20
12mm - 16mm M4 x 30 + spacer
17mm - 21mm M4 x 30
22mm - 26mm M4 x 40 + spacer
27mm - 32mm M4 x 40
Should the screws foul on the back of the shutters during
installation replace with the next size down.
5. Using the three screws (and spacers fitting under the screw
heads if required) locating with the threaded inserts in the outer
assembly, draw the inner and outer assemblies together. Remove
any tape supporting the outer assembly and continue to draw the
units together until the rubbe gaskets positively locate the unit on
the window.
Note: do not overtighten the fixing screws as this may distort the
assembly. Replace the shutters in the outer frame assembly.
6. Wire unit in accordance with the appropriate wiring diagram.
A cable clamp is provided inside the case.
Note: the remaining installation procedures for Window
Mounting are as Surface Mounting description.