Isolation - Before commencing work make sure that the unit
is electrically isolated from the mains supply.
If in doubt consult an electrician.
4.0 Wiring Instructions
Disconnection from the supply mains must be incorporated within the
fixed wiring in accordance with the wiring regulations and shall have a
minimum contact separation of 3mm in accordance with the latest
edition of the IEE Wiring Regulations.
nly GPE-100X-12 models are suitable for shower cubicles or
zones 1 & 2 (in this range).
SL = 230Vac Switched Live L = 230Vac Permanent Live N = Neutral
Figure 4a. Wiring.
.
5.0 peration
verrun timer boost adjustment
Before making any adjustments, isolate the fan from the power supply.
Remove the front cover and the body moulding. Locate the ‘jumper’ on
the relevant set of pins to achieve the desired run-on time (see Fig. 4b).
Humidity boost adjustment
All humidistat GPE-100X units automatically sense a rapid change in
humidity and adjust accordingly. The humidity control does not require
manual adjustment. Humidistat fans, when energised for the first time,
will run and time out as part of the stabilising process.
Performance: Position jumpers for desired trickle and boost
performance. (Fig. 4b)
Trickle: Position 1 6 l/s (Default setting)
Position 2 7 l/s
Position 3 8 l/s
Position 4 9 l/s
Boost: Position 5 12 l/s
Position 6 14 l/s
Position 7 16 l/s
Position 8 Boost 20 l/s (Default setting)
Rating: 230V 50Hz IPX4
This product is double insulated and does not require an earth conductor.
Maximum room temperature 40ºC.
6.0 Maintenance
The fan unit does not require any maintenance. However, for
optimum performance, it is advisable to remove any accumulated
dust with a low power vacuum cleaner.
Note: Installation and Maintenance of the equipment must
be as directed in the instructions provided with the unit.
7.0 Warranty
The 5 year warranty starts from the day of delivery and includes
parts and labour for the first year. The remaining 4 years covers
replacement parts only.
This warranty is void if the equipment is modified without
authorisation, is incorrectly applied, misused, disassembled, or not
installed, commissioned and maintained in accordance with the details
contained in this manual and general good practice.
The product warranty applies to the UK mainland and in accordance
with Clause 14 of our Conditions of Sale. Customers purchasing from
outside of the UK should contact Nuaire International Sales office for
further details.
8.0 After Sales Enquiries
For technical assistance or further product information, including spare
parts and replacement components, please contact the After Sales
Department.
Telephone 02920 858 400
205. 07. 18. Leaflet Number 671744
Installation and Maintenance Genie Plus GPE-100X Range of Centrifugal Fans
HUMIDITY SENSOR
NEUTRAL
LIVE
SWITCHED LIVE
TIMER ADJUST
5 MINS 15 MINS 30 MINS
SPEED SELECTION
BOOST TRICKLE
8 7 6 5 4 3 2 1
Figure 4b. Wiring. PCB details
Technical or commercial considerations may, from time to time,
make it necessary to alter the design, performance and
dimensions of equipment and the right is reserved to make such
changes without prior notice.
L
N
SL
N
L
Fuse 2 amp
(BS 1362)
3 Pole Isolator
Fan Unit
2 Pole Switch
Optional Lamp
Mains
230V
50Hz