manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. NuAire
  6. •
  7. Fan
  8. •
  9. NuAire Genies Plus GP-100 Series Instruction Manual

NuAire Genies Plus GP-100 Series Instruction Manual

This manual suits for next models

3

Other NuAire Fan manuals

NuAire AVT-R User manual

NuAire

NuAire AVT-R User manual

NuAire AxTan AXH80DG-4LN User manual

NuAire

NuAire AxTan AXH80DG-4LN User manual

NuAire MEV-M Instruction Manual

NuAire

NuAire MEV-M Instruction Manual

NuAire ES-MEV Assembly instructions

NuAire

NuAire ES-MEV Assembly instructions

NuAire DAVE Series Installation and operating instructions

NuAire

NuAire DAVE Series Installation and operating instructions

NuAire MRXBOX95B-WHI Instruction Manual

NuAire

NuAire MRXBOX95B-WHI Instruction Manual

NuAire ECOSMART AIRMOVER Instruction Manual

NuAire

NuAire ECOSMART AIRMOVER Instruction Manual

NuAire MRXBOX95B-LOFT Instruction Manual

NuAire

NuAire MRXBOX95B-LOFT Instruction Manual

NuAire MRXBOXAB-ECO3-AESW User manual

NuAire

NuAire MRXBOXAB-ECO3-AESW User manual

NuAire DRI-ECO-LINK-HC Instruction Manual

NuAire

NuAire DRI-ECO-LINK-HC Instruction Manual

NuAire ILM Series User manual

NuAire

NuAire ILM Series User manual

NuAire Xboxer xbc+ Ecosmart Connect Control User manual

NuAire

NuAire Xboxer xbc+ Ecosmart Connect Control User manual

NuAire MRXBOX95B-LH2 Instruction Manual

NuAire

NuAire MRXBOX95B-LH2 Instruction Manual

NuAire MRXBOX-ECO2-1Z User manual

NuAire

NuAire MRXBOX-ECO2-1Z User manual

NuAire MRXBOX-SIL4 Instruction Manual

NuAire

NuAire MRXBOX-SIL4 Instruction Manual

NuAire ECOSMART XTRACTOR Manual

NuAire

NuAire ECOSMART XTRACTOR Manual

NuAire SVT28 Series User manual

NuAire

NuAire SVT28 Series User manual

NuAire MEV-ECO User manual

NuAire

NuAire MEV-ECO User manual

NuAire MRXBOX95-WM2 User manual

NuAire

NuAire MRXBOX95-WM2 User manual

NuAire SLIMAIRE/NA Series Instruction Manual

NuAire

NuAire SLIMAIRE/NA Series Instruction Manual

NuAire MEV Ecosmart Instruction Manual

NuAire

NuAire MEV Ecosmart Instruction Manual

NuAire MRXBOXAB-ECO5-AE User manual

NuAire

NuAire MRXBOXAB-ECO5-AE User manual

NuAire AM User manual

NuAire

NuAire AM User manual

NuAire MRXBOX-SIL2 Instruction Manual

NuAire

NuAire MRXBOX-SIL2 Instruction Manual

Popular Fan manuals by other brands

Minka Group minkaAire Wave F843 instruction manual

Minka Group

Minka Group minkaAire Wave F843 instruction manual

Airflow Adroit DV50 instruction manual

Airflow

Airflow Adroit DV50 instruction manual

Vornado 270 Series owner's guide

Vornado

Vornado 270 Series owner's guide

comfort air TH-10D instruction manual

comfort air

comfort air TH-10D instruction manual

Livoo DOM386 instruction manual

Livoo

Livoo DOM386 instruction manual

Holmes BLIZZARD HAOF-90 owner's guide

Holmes

Holmes BLIZZARD HAOF-90 owner's guide

Taurus GRECO 16 ELEGANCE manual

Taurus

Taurus GRECO 16 ELEGANCE manual

Quorum PINNACLE installation instructions

Quorum

Quorum PINNACLE installation instructions

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Craftmade UH52 installation guide

Craftmade

Craftmade UH52 installation guide

Jocel JVA030658 instruction manual

Jocel

Jocel JVA030658 instruction manual

MIKA MFB1211/GR user manual

MIKA

MIKA MFB1211/GR user manual

Harbor Breeze RLG52NWZ5L manual

Harbor Breeze

Harbor Breeze RLG52NWZ5L manual

Allen + Roth L1405 instruction manual

Allen + Roth

Allen + Roth L1405 instruction manual

ViM KUBAIR F400 ECOWATT Technical manual

ViM

ViM KUBAIR F400 ECOWATT Technical manual

HIDRIA R10R-56LPS-ES50B-04C10 user guide

HIDRIA

HIDRIA R10R-56LPS-ES50B-04C10 user guide

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

BLAUBERG Ventilatoren

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

Triangle Engineering HEAT BUSTER SPL Series owner's manual

Triangle Engineering

Triangle Engineering HEAT BUSTER SPL Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Isolation - Before commencing work make sure that the unit,
switched live and uaire control are electrically isolated from
the mains supply.
111. 05. 17. Leaflet Number 671741
Figure 3. Fan Dimensions (mm)
170
170
110
9
72
The EMC Directive
2014/30/EU
The Low Voltage
Directive
2014/35/EU
Fig. 1a. Removing front facia. Fig. 1b. remove 4 screws and front half.
Fig. 2. Pass the supply cable through the cable entry point.
Genie Plus GP-100 Range
Centrifugal Wall/Ceiling Mounted
Toilet and Bathroom Fans
Installation and Maintenance
99
69
IPX4
1.0 Introduction
These high quality extractor fans are designed to provide effective
ventilation. To achieve this, please read these instructions carefully
BEFORE installing the fan unit. Failure to comply with these
instructions could reduce both the life and performance of the
product and may invalidate the warranty.
This product is suitable for use with up to a maximum of 6.0m of
rigid ducting. (Flexible ducting is not recommended).
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack
of experience and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children without supervision.
2.0 Installation
The installation must be completed by competent persons in
accordance with good industry practice and should conform to all
governing and statutory bodies i.e. IEE, CIBSE, HVCA etc.
Before commencing any work read the following instructions carefully
and ensure you have the necessary competency to complete the work
safely.
1. Select a suitable position for t e fan t at keeps t e duct as s ort
and as straig t as possible (ideally on t e ceiling or on a wall wit in
400mm of t e ceiling).
2. Cut a ole in t e wall to suit t e outside diameter of t e ducting or
wall-liner. Install t e duct or wall-liner taking care to seal at bot
ends between it and t e wall using proprietary waterproof mastic.
If required, connect furt er ducting to t e wall-liner, sealing
between eac joint or fitting.
3. Remove t e front cover of t e fan by pulling straig t off t e fan
body (Fig. 1a and 1b).
4. Remove and retain t e bag containing four Posidriv® screws for
retaining t e body moulding to t e back-plate (Fig. 1b) and t e
cable clamp and screws.
5. Locate t e fan back-plate into t e wall-liner/duct and mark t e four
retaining screw positions (Fig. 2). Fit screw anc ors suitable for
t e wall construction.
6. Install t e fan taking care to pass t e supply cable t roug t e cable
entry point in t e fan back-plate moulding (Fig. 2).
7. Complete t e wiring by following t e relevant wiring diagram on
t e following page (Fig. 4).
8. Assemble t e fan body to t e back-plate and clip on t e front cover.
3.0 Dimensions
Nuaire: A Trading Division of Polypipe Limited Western Industrial Estate Caerphilly United Kingdom CF83 1NA
T: 029 2088 5911 F: 029 2088 7033 E: [email protected] W: www.nuaire.co.uk
Isolation - Before commencing work make sure that the unit
is electrically isolated from the mains supply.
If in doubt consult an electrician.
4.0 Wiring Instructions
Disconnection from the supply mains must be incorporated within the
fixed wiring in accordance with the wiring regulations and shall have a
minimum contact separation of 3mm in accordance with the latest
edition of the IEE Wiring Regulations.
Only GPE-100-12 SELV models are suitable for shower cubicles or
zones 1 & 2 (in this range).
SL = 230Vac Switched Live L = 230Vac Permanent Live = eutral
Unit Serving Bathroom GP-100 Figure 4a. Wiring.
Unit Serving Bathroom GP-100-HPC via pullcord
(Auto humidity only) Figure 4b. Wiring.
Unit Serving Bathroom GP-100-T / GP-100-HPC via remote
switch (Optional timer operation) Figure 4c. Wiring.
5.0 Operation
Overrun timer adjustment – models fitted with overrun
timers only
Before making any adjustments, isolate the fan from the power supply.
Remove the front cover and the body moulding. Locate the ‘jumper’ on
the relevant set of pins to achieve the desired run-on time (see Fig. 4d).
Humidity adjustment – humidistat models only
All GP humidistat fans automatically sense a rapid change in humidity
and adjust accordingly. The humidity control does not require manual
adjustment. Humidistat fans, when energised for the first time, will run
and time out as part of the stabilising process.
Performance: 19 l/s at 0 Pa – 96 Pa at 0 l/s
Rating: 230V 50Hz 22W IPX4
This product is double insulated and does not require an earth conductor.
Maximum room temperature 40ºC.
Range:
GP-100 Standard
GP-100-T Overrun timer
GP-100-HPC Humidistat and optional overrun timer and
pull-cord switch override
6.0 Maintenance
The fan unit does not require any maintenance. However, for
optimum performance, it is advisable to remove any accumulated
dust with a low power vacuum cleaner.
ote: Installation and Maintenance of the equipment must
be as directed in the instructions provided with the unit.
7.0 Warranty
The 5 year warranty starts from the day of delivery and includes parts
and labour for the first year. The remaining 4 years covers
replacement parts only.
This warranty is void if the equipment is modified without
authorisation, is incorrectly applied, misused, disassembled, or not
installed, commissioned and maintained in accordance with the details
contained in this manual and general good practice.
8.0 After Sales Enquiries
For technical assistance or further product information, including
spare parts and replacement components, please contact the After
Sales Department.
Telephone 02920 858 400
211. 05. 17. Leaflet Number 671741
Installation and Maintenance Genie Plus GP-100 Range of Centrifugal Fans
L
N
SL
N
L
Fuse 2 amp
(BS 1362)
3 Pole Isolator
Fan Unit
2 Pole Switch
Optional Lamp
Mains
230V
50Hz
L
N
N
L
Fuse 2 amp
(BS 1362) Fan Unit
Mains
230V
50Hz
2 Pole Isolator
L
L
N
N
L
Fuse 2 amp
(BS 1362) Fan Unit
Mains
230V
50Hz
2 Pole Isolator
Remote
Switch
TIMER ADJUST
5 MINS 15 MINS 30 MINS
NEUTRAL
LIVE
SWITCHED LIVE PULL CORD
HUMIDITY
SENSOR
Figure 4d. Wiring. PCB details (where applicable)
Technical or commercial considerations may, from time to time,
make it necessary to alter the design, performance and
dimensions of equipment and the right is reserved to make such
changes without prior notice.