OCTELL OT-100 User manual

OCTELL
OT 100
: OT 100

Director
Product introduction
Product structure description
Product display introduction
How to install the battery
Setting operation
Measurement method
Maintenance and precautions
Troubleshooting
Product specifications
Contraindications, precautions, warnings, and
instructions
Graphics, symbols, abbreviations, etc. used in
medical device labels
Electromagnetic compatibility related information
Certificate and warranty card

Note
Statement
1. Calibrate the infrared thermometer before measurement, check the function of each part
and maintain the good performance of the infrared thermometer.
2. Keep the power supply sufficient to determine whether the external environment meets the
product's specified operating environment.
3. After the product is packaged, it is allowed to be transported by common transportation, but
it should avoid rain, moisture, and mechanical collision of squeeze boxes.
The clinical accuracy or clinical deviation of the thermometer has passed clinical
verification, and its safety and effectiveness meet the requirements of relevant
national laws and regulations. For the method of verifying the claimed
performance of the product, you can obtain it by contacting our customer service
department
This infrared forehead thermometer is a high-quality product. It uses infrared
technology. Each time it is turned on, it will enter a self-test to ensure the accuracy
of the measurement. This infrared forehead thermometer is mainly used to
measure the temperature of the human forehead. This product can accurately and
stably perform temperature measurement. Users only need to point the probe
head to the forehead and press the measurement button, and the body
temperature can be measured quickly and accurately in one second. In order to
ensure the accuracy of the measurement results and the safety of use, please read
the instructions carefully before use.
This product is widely used in schools, customs, hospitals, homes, etc.
1.Product introduction
Display the temperature of the subject by measuring the thermal amplitude of the
forehead
Detection principle
Components
Consists of housing, infrared temperature sensor, signal receiving processor,
buttons, COB board, buzzer and LCD display

-
2.Safety instructions
3. Productstructure introduction
This product is only suitable for the purpose described in the instructions, such as
damage caused by abnormal use. The manufacturer is not legally responsible.
2.1 Never put this product into water or other liquids. For cleaning, wipe with a
damp soft cloth.
2.2 If you think this product is damaged or abnormal, please prohibit the use of the
product.
2.3 Do not open this product without permission
2.4 In the early stage of fever, vasoconstriction will occur, and the temperature of
the skin surface will drop. At this time, the measured temperature will be
abnormally low.
2.5 If the measurement result does not match the patient's diagnosis or the
measurement temperature is abnormally low, repeat the measurement every 15
minutes or take another measurement of the core body temperature area to verify
the previous measurement results.
2.6 This equipment includes sensitive originals and must not be treated.
Description of storage and operation adjustment
2.7 contains small parts, in order to avoid accidental eating, children need to use
under adult supervision
** Please stay away from the following situations
a) Extreme temperature b) Shock and drop
c) pollution and dust d) direct sunlight
e) Hot and cold environment f) If it cannot be used for a long time, please remove
the battery and place it
1-Infrared detector
2-LCD display
3-Down button
4-Up button
5-Set button
6-Measure button
7-Battery
compartment cover
1
3
5
4
6
7
2

menu
Features
"-"key
"+" Key
Initial value
Note
P1
Temperature unit
℃
°F
℃
This product provides five function settings such as temperature unit, prompt tone
switch, temperature alarm point, temperature change, and test mode. The
measurement mode is switched by the mode switch key. Other settings are set in
the setting menu. Long press the setting key to enter the menu setting
4.Product display
5.How to install the battery
Test mode
2. Display value
3. Battery symbol
4. Storage location
5. Read out stored data
6. Temperature unit
7.Beep symbol
1
2
7
3
6
6. Set operation
4
This machine comes with DC.3V (two AAA batteries). When the low voltage icon
flashes on the screen, you need to replace the battery.
Remove the battery back cover in the direction indicated (Step 1)
Replace the battery, and reproduce the battery correctly according to the positive
and negative poles indicated (step 2)
1: Hold the unit and open the battery back cover in the direction indicated
2: Insert DC.3V (two AAA batteries) batteries and pay attention to the battery
polarity indication
Expendable battery replacement cycle and replacement method
The removable parts of this product mainly include the battery. Before installing
the accessories, please confirm whether the specifications and models are
consistent with the original ones. Be sure to use the parts specified by our
company. If necessary, please contact the seller or manufacturer.
Battery installation and replacement: When the low voltage reminder symbol
appears on the display, please replace the special battery installation
5

P2
Temperature
alarm point
Decrease
0.1 ℃
Increase by
0.1 ℃
38℃
P3
Temperature
offset
Offset
0.1 ℃
Offset 0.1 ℃
0.0
range
-3 ℃~ +
3℃
P4
Beep switch
turn off
open
open
8. Maintenance and precautions
9.Troubleshooting
7. Test method
Keep the inner cavity of the sensor and probe clean, otherwise it will affect
the measurement accuracy.
Cleaning method:
1 Surface cleaning: Wipe the dirty area with a clean soft cloth or cotton
swab dipped in a little medical alcohol or water.
Before using, please read this instruction manual carefully and confirm that
the battery is installed.
It is forbidden to enter the thermometer into any liquid, and it is forbidden to
be placed in an excessively high or low temperature environment for a long
time.
It is forbidden to collide, drop or mix sharp objects, and it is forbidden to
disassemble by yourself.
Do not use the thermometer under the sun or in water.
1. Ambient temperature below 10 degrees or above 38 degrees shows Err
2. Body temperature mode, display LO below 32 degrees
3. Body temperature mode above 43 degrees shows Hi
The infrared forehead thermometer has no display on the LCD screen in standby
mode. Press the test button once in standby mode. The LCD screen is fully
displayed for about 2 seconds. At the same time, the backlight is turned on. The
buzzer sounds a long beep, and the screen The last test temperature value is
displayed, and the infrared forehead thermometer enters the temperature
measurement mode.
In the thermometer measurement mode, turn the function selection key to the
body temperature direction, press the measurement key once, the backlight turns
on, and the infrared thermometer starts to measure the target temperature. After
about one second, the buzzer emits a relevant sound and the measurement result
Displayed on the LCD display, you can press the measurement key again to measure
the temperature.

Display range:
35.1°C~42.8°C(95.18℉~109.04℉)
Temperature
resolution
0.1℃/32.18°F
Measuring
distance
3CM~5CM
Memory array
32 groups
Clinical
repeatability
±0.3℃(±32.54℉)
Maximum
allowable error
±0.3℃(±32.54℉)
Operating
environment
Temperature: 15 ℃ ~ 40 ℃ (9℉~104℉)
Relative humidity: ≦85%
Automatic
Shut-Down
20 ±2 Seconds
power supply
DC-3.0V(two AAA Batteries)
size
160MM×100MM×40MM
weight
123g
10. Product Specifications
1. Warning and informative instructions
(1) Make sure to remove the hair and sweat from the forehead before measuring
(2) Use of this product cannot replace doctor's diagnosis
(3) Please contact the distributor if there is a problem with the product, do not try
to repair it by yourself
(4) The protective glass outside the LCD frame is very important, and it is also the
fragile part of the meter. Please use it with care.
(5) Please do not charge the non-rechargeable battery and do not throw the
battery into a fire.
(6) Please do not expose this product to the sun.
1cm-1.5cm
Memory Count 100
105g
174MM X 110MM X 49MM
1cm - 15cm

Reference instructions
Note, refer to the attached file
Keep dry
B-type application equipment
Avoid the sun
Low battery alert
Place up
Fragile, handle with care
13. Electromagnetic compatibility related
12. Medical device graphics
note:
This product complies with the relevant electromagnetic compatibility
requirements of YY0505 standard;
Users should install and use according to the electromagnetic compatibility
information provided in the random files;
Portable and mobile RF communication equipment may affect the performance of
this product. Avoid strong electromagnetic interference when using it, such as near
mobile phones, microwave ovens, etc.
Guidance and manufacturer's declaration are detailed in the annex.
Warning:
This product should not be used close to or stacked with other equipment. If it
must be used close to or stacked, it should be observed to verify that it can
operate normally in the configuration in which it is used;
Class A equipment is intended for use in an industrial environment. Due to the
radiated disturbance of this product, it may be potentially difficult to ensure
electromagnetic compatibility in other environments: except for cables sold by the
manufacturer of this product as spare parts for internal components, use of
Accessories and cables may cause increased emissions or reduced immunity of this
product.

annex:
Guidance and manufacturer's declaration-electromagnetic emissions
This product is intended for use in the electromagnetic environment specified below.
The purchaser or user of this product should ensure that it is used in this
electromagnetic environment.Use:
Launch test
Compliance
Electromagnetic
Environment-Guide
Radio frequency emission
GB 4824
team 1
This product uses radio
frequency energy only for its
internal functions. So it ’s
Radio frequency emissions are
low and there is little chance
of interference with nearby
electronics.
Radio frequency emission
GB 4824
Class A
This product is suitable for
use in non-domestic and
residential public
All facilities in the
low-voltage power supply
network.
Harmonic emission
GB 17625.1
Not applicable
Voltage fluctuation /
flicker emission GB
17625.2
Not applicable
G u id a n c e a n d m a nu f a c t u re r ' s d e c l ar a t i o n -e l e c t r o ma g n e t i c i mm u n i t y
This product is intended for use in the electromagnetic environment specified below,
and the purchaser or user should guarantee its use in this electromagnetic
environment:
Immunity test
IEC 60601 test
level
Coincidence level
Electromagnetic
Environment-Guide
Electrostatic
discharge
GB / T 17626.2
± 6 kV contact
discharge
± 8 kV air
discharge
± 6 kV contact
discharge
± 8 kV air
discharge
The ground should be
wood, mixed
Condensate or tiles,
if the floor is
covered with
synthetic material,
the relative
humidity should be
at least 30%.
Electrical fast
transient burst
GB / T 17626.4
± 2kV to power
line
± 1kV to input /
output
Not applicable
Not applicable

surge
GB / T 17626.5
± 1 kV
differential
mode voltage
± 2 kV common
mode voltage
Not applicable
Not applicable
Temporary voltage
on power input line
Drops, short
interruptions and
voltage changes
Turn into
GB / T 17626.11
<5% UT for 0.5
cycles
(On UT,> 95% dips)
40% UT for 5 cycles
(60% sag on UT)
70% UT for 25 cycles
(30% sag on UT)
<5% UT for 5s
(On UT,> 95% dips)
Not applicable
Not applicable
Power frequency
magnetic field (50
/ 60Hz)
GB / T 17626.8
3A/m
3A/m,50/60Hz
Power frequency
magnetic field should
have power frequency
magnetic field level
characteristics in a
typical place in a
typical commercial or
hospital environment
Note: UT refers to the AC network voltage before the test voltage is applied
Guidance and manufacturer's declaration-electromagnetic immunity
This product is intended to be used in the electromagnetic environment specified
below. The purchaser or user of this product should ensure that it is in this
electromagnetic environment.
use:
Immunity test
IEC 60601 test level
Coincidence
level
Electromagnetic
Environment-Guide
Radio frequency
conduction
GB / T 17626.6
3 V(Effective value)
150 kHz~80 MHz
Not applicable
Portable and mobile RF
communications
equipment should not be
used closer to any part
of this product,
including cables, than
the recommended
isolation distance.
This distance should be
calculated by a formula
corresponding to the

Radio frequency
radiation
GB / T 17626.3
3 V/m
80 MHz~2.5 GHz
3 V/m
frequency of the
transmitter.
Recommended isolation
distance
d = 1.2 P
d = 1.2 P 80 MHz to 800
MHz
d = 2.3 P 800 MHz ~ 2.5
GHzWhere:
P — based on the
transmitter's maximum
rated output power
provided by the
transmitter
manufacturer, in watts
(W);
d—Recommended
isolation distance in
meters (m) b. The field
strength of the fixed
RF transmitter is
determined by
surveying the
electromagnetic field
c. In each frequency
range d should be more
than
Low level.
Interference may occur
near the equipment
marked with the
following symbol.
Note 1: At 80MHz and 800MHz frequencies, the higher frequency band formula is used.
NOTE 2 These guidelines may not be suitable for all situations. Electromagnetic
propagation is affected by absorption and reflection from buildings, objects and
people.
a Fixed transmitters, such as: base stations for wireless (cellular / cordless)
telephones and terrestrial mobile radios, amateur radios, AM and FM radio
broadcasts, and television broadcasts, the theoretical field strengths cannot be
accurately predicted in theory. To assess the electromagnetic environment of fixed
RF transmitters, surveys of electromagnetic sites should be considered. If the

measured field strength of the product is higher than the applicable RF compliance
level described above, the product should be observed to verify normal operation.
If abnormal performance is observed, supplementary measures may be necessary, such
as reorienting or repositioning the product.
b In the entire frequency range from 150KHz to 80MHz, the field strength should be
lower than 3 V / m.
Recommended isolation distance between portable and mobile RF communication
equipment and this product
This product is intended for use in an electromagnetic environment where radio
frequency radiation disturbances are controlled. Depending on the maximum rated
output power of the communication equipment, the purchaser or user can prevent
electromagnetic interference by maintaining the minimum distance between portable
and mobile RF communication equipment (transmitters) and this product as recommended
below.
Transmitter rated
maximum output
Power / W
Transmitter's rated maximum output power / W
150 kHz ~ 80 MHz
d =
1.2 P
80 MHz ~ 800
MHz
d =
1.2 P
800 MHz~ 2.5 GHz
d =
2.3 P
0.01
Not applicable
0.12
0.23
0.1
Not applicable
0.38
0.73
1
Not applicable
1.2
2.3
10
Not applicable
3.8
7.3
100
Not applicable
12
23
For the transmitter's rated maximum output power not listed in the table above, the
recommended isolation distance d is in meters (m), and the corresponding transmission can be
used
The formula in the frequency column of the transmitter, where P is the maximum output power
of the transmitter provided by the transmitter manufacturer, in watts (W)
As a unit.
Note 1: At 80 MHz and 800 MHz, the higher frequency range formula is used.
NOTE 2 These guidelines may not be suitable for all situations. Electromagnetic propagation is
affected by absorption and reflection from buildings, objects and people.
Table of contents
Popular Thermometer manuals by other brands

Extech Instruments
Extech Instruments 42570 user manual

Exergen
Exergen TAT-2000C Instructions for use & warranty

Weems & Plath
Weems & Plath Vermont Grande View Thermometer quick start guide

Hartmann
Hartmann Thermoval rapid quick start guide

Elma Instruments
Elma Instruments 614 user manual

Miaomiaoce
Miaomiaoce MMC-W501 user guide