ODM DLS350 User manual

DLS3-00-2000 Rev A 1-13-11
Specifications subject to change without notice
Models DLS350, DLS355
Dual LED, Dual LASER Source
____________________________________________________________________________________
143 Lake St, Laconia, NH USA 03246 ◘603-524-8350
Fax - 603-524-8332 ◘www.odm-inc.com
ODM DLS355 Specs
Provided by www.AAATesters.com

Page 1of 13
Contents
Introduction………………………………………………………………………………………..page 2
Section 1 - General Overview
1.1 Safety…………………………………………………………………page 3
1.2 Warranty…………………………………………………………...page 5
1.3 Unpacking and Inspection……………………………….…page 5
Section 2 - Feature Overview and Usage Instructions
2.1 Feature Overview…………………………………………….page 6
2.2 Usage Instructions……………………………………………page 9
Section 3 –Specifications………………………………………………….………………page 10
Section 4 –Accessories…………………………………………………..………………….page 11
Section 5 –Contact Information………………………………………..…………….page 12

Page 2of 13
Introduction
Dear Valued Customer,
Thank you for choosing ODM, Inc. for your fiber optic testing requirements. Our professional staff is available to answer
any questions or provide assistance that you may require. We, at ODM Inc., strive to provide premier customer care and
technical support by providing timely responsiveness and training. We are proud of our quality and high standards and
assure you, our customer, the most user friendly and affordable fiber optic solutions to meet individual needs.
Sincerely,
Michael E. Schneider
President, ODM, Inc.

Page 3of 13
Section 1 –General Overview
1.1 Safety Warnings!
Please read the following warnings and precautionary notes before using any product containing light or laser source:
1) Never look directly into the path of any light or laser source, patch cord or adapter as it may cause temporary or
permanent blindness or damage to the eyes. Never point a laser or light source at another individual.
2) Always assume that the light or laser source output is active! The light is never visible.
3) In order to prevent any type of hazard, never open or try to adjust the instrument. Contact ODM Inc. for
assistance. 603-524-8350
4) Laser Classifications of ODM light source:
a. DLS350 is a CLASS I LED PRODUCT
b. DLS355 is a CLASS I LASER PRODUCT

Page 4of 13
Safety Warnings! Continued
5) Never expose the instrument to severe conditions that may cause personal injury, fire, electrical shock or damage
to the instrument. This includes but is not limited to:
a. Never use an AC adapter with the instrument other than that which is specified or rated by ODM Inc.
b. Do not use a damaged AC Adapter (exposed wires or shorted). Please contact ODM Inc. for service.
c. Instruments should never be opened. Please contact ODM Inc. for service.

Page 5of 13
1.2 Warranty
ODM Inc. warranties their instruments for a period of two years for repair or replacement from the date of shipment to
original customer. The warranty covers defective material and/or workmanship.
Warranty will be void if instrument is found to be damaged by misuse, abuse, accident or unauthorized repair.
Calibration within first year is covered under warranty. Please contact ODM Inc. for instructions for appropriate RMA
authorization.
1.3 Unpacking and Inspection
The DLS series instruments are carefully inspected and packed according to standard shipping practices. The individual
components include:
1. DLS350 Dual LED or DLS355 Dual Laser Source with universal connector interface
2. 1 –CR2 3V Lithium Battery
3. Rugged padded single instrument pouch with belt loop
4. User’s Guide, Specification Sheet and Certificate of Compliance
Please contact ODM Inc if your equipment has arrived to you damaged.

Page 6of 13
Section 2 –Feature Overview and Usage Instructions for DLS Series instruments
2.1 Feature Overview
The DLS350 and DLS355 are both dual wavelength single output light sources. DLS350 LED source offers 850 & 1300
nm wavelengths for multimode testing while the DLS355 Laser Source offers 1310 & 1550 for singlemode applications.
The small form and user friendly application of this instrument affords the user one hand operation allowing quick, easy
testing.

Page 7of 13
Figure 1

Page 8of 13
Features
See Figure 1 on page 7
1) Universal Connector Interface
The universal connector interface included with the DLS accepts many connector types including FC, SC, ST and LC.
The screw on style connector provides easy switching to hybrid adapters to accommodate various connector
styles. Please contact ODM for available connector styles and patch cords.
2) Power Key
To power the DLS press the PWR button. To turn the DLS off, press
PWR button again. The DLS is set to turn off after 15 minutes. For continuous operation
press and hold the PWR button for three seconds or power on.
3) λ Wavelength Select
Press the λ button to toggle between 850nm and 1300nm for the
DLS 350 or 1310nm and 1550nm for the DLS 355.DLS 350 & DLS 355 Operation & Service
4) λ Wavelength Indicator
The wavelength indicator will be on, signifying that power is on and wavelength selected.
5) Low Battery Indicator
Low Battery condition exists when the LOW BATT LED flashes.
The DLS operates from a long life CR2, 3V Lithium Battery.

Page 9of 13
6) 2kHz Mode
To modulate the DLS @ 2kHz press the 2kHz button.
7) External Power Port
External power port accepts a 120 volt or 240 volt AC Adapter. Please see Accessories section for available AC
Adapters.
2.2 Usage Instructions
The DLS 350 and DLS355 are used in conjunction with the RP 400 series power meters providing loss measurements
according to EIA/TIA standards.
The DLS 350/DLS 355 dual light sources also provide a 2kHz tone output for fiber identification when used with the RP
400 series power meters. The incoming 2kHz signal is identified and an audible alert is provided by the RP 400 series
power meter. The 2 kHz tone provided by the DLS 350 and 355 may also be used with non invasive fiber identifier
devices such as the LFI 110 Live Fiber Identifier from ODM.
Connection to the device under test (DUT) is by the universal connector output allowing for easy cleaning of the
connector surface. Please contact ODM for hybrid adapters to accommodate different connector styles. See Accessories
section for available hybrid adapters. These dual sources are provided with a long lasting battery or may be factory
configured for optional AC operation.

Page 10 of 13
Section 3 - Specifications for DLS350 & DLS355
Specifications
DLS 350
DLS 355
Wavelength
850nm & 1300nm LED
1310nm & 1550nm Laser
Output power
- 20dBm Typ.
- 4.0 dBm Typ.
Laser Classification
NA
Class 1 (FDA 21 CFR 1040, 11)
Output stability
+/- 0.05dB, one hour
+/- .03dB long term after 15 minute warm-up
Spectral Width
40nm/120nm
5nm/5nm
Optical interface
Universal connector
(contact ODM for other connector styles)
Tone Output
2kHz
Power on
Push button ON, Auto shutoff
Battery
CR 2 , Optional AC power for long term
Dimensions
6.1x.94x.75 in. (15.5x2.38x1.90cm)
Weight
3.0 oz (8.5g)
Operating Temperature
-10 to 50˚C
Storage Temperature
-30 to 60˚C

Page 11 of 13
Section 4 - Accessories
Adapters
AC 022
SC Adapter for Optical Light Source, DLS 350 & DLS 355
AC 023
FC Adapter for Optical Light Source, DLS 350 & DLS 355
AC 024
ST Adapter for Optical Light Source, DLS 350 & DLS 355
AC 025
LC Adapter for Optical Light Source, DLS 350 & DLS 355
Cleaning Kits
CK125
Cleaning Kit includes fiber cleaning solution, wipes, 1.25mm swabs, 2.5mm swabs for
200 connectors and adapters
CK250
Cleaning Kit includes fiber cleaning solution, wipes, 1.25mm swabs, 2.5mm swabs for
400 connectors and adapters
Carry Cases
AC 010
Single Instrument padded pouch fits all power meters, light sources and VFI’s
AC 011
Hard Case for up to four instruments
This manual suits for next models
1
Table of contents
Other ODM Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Benning
Benning ST 710 operating manual

Pyxis
Pyxis DW-739 Series user manual

Nikon
Nikon LASER 800S instruction manual

IMI SENSORS
IMI SENSORS PCB Piezotronics TO622B01 Installation and operating manual

Avid Technology
Avid Technology LP Series Installation and operation manual

SICK
SICK VICOTEC450 operating instructions

Christ Elektronik
Christ Elektronik CPM138-AC instruction manual

PCB Piezotronics
PCB Piezotronics IMI SENSORS EX603C01/ICS-29 Installation and operating manual

Axis
Axis F9114 installation guide

Johnson
Johnson 40-6690 quick start guide

Omega Engineering
Omega Engineering FMA-1600A Series user guide

JYTEK
JYTEK PXI-69816D user manual