Warning
The operating description in this Instruction Manual is for use by
qualifiedpersonnelonly.Toavoidelectricalshock, donotperformany
servicing of this unit other than that contained in the operating
instructions, unless you are qualified and certified to do so by
OmnitronSystems Technology, Inc.
Warranty
Thisproduct is warranted to theoriginal purchaseragainst defects
inmaterial andworkmanship for a period ofTWO YEARSfrom the
date of shipment. A LIFETIME warranty may be obtained by the
original purchaser by REGISTERING this product with Omnitron
within 90 days from the date of shipment. TO REGISTER,
COMPLETE AND MAIL OR FAX THE ENCLOSED
REGISTRATIONFORM. Oryou may registeryour product onthe
Internetat www.omnitron-systems.com. Duringthe warrantyperiod,
Omnitron will, at its option, repair or replace a product which is
provento bedefective.
Forwarrantyservice,theproductmustbesenttoanOmnitrondesignated
facility,at Buyer’sexpense.Omnitron will paythe shippingcharge to
returntheproducttoBuyer’s designatedUSaddressusingOmnitron’s
standardshippingmethod.
Limitation of Warranty
Theforegoingwarrantyshallnotapplytodefectsresultingfromimproper
orinadequateuseand/ormaintenanceoftheequipmentbyBuyer,Buyer-
supplied equipment, Buyer-supplied interfacing, unauthorized
modifications or tampering with equipment (including removal of
equipmentcoverbypersonnel notspecificallyauthorizedandcertified
by Omnitron), or misuse, or operating outside the environmental
specificationoftheproduct(includingbutnot limited to voltage,ambient
temperature,radiation,unusualdust,etc.),or improper sitepreparation
ormaintenance.
No other warranty is expressed or implied. Omnitron specifically
disclaimstheimplied warranties ofmerchantabilityand fitnessforany
particularpurpose.
LED INDICATORS
LED Color Description
Pwr: Yellow On--Power /Blink--test
Fiber FDX: Green On--Full-Duplex detected
Lk/Act Green On--Link/ Blink--activity
AN: Green On--UTPAuto-Neg. enabled
10: Green On--10Mbps link /Blink-activity
100: Green On--100Mbpslink /Blink-activity
1000: Green On--1000 Mbps link / Blink-activity
UTP FDX: Green On--Full-Duplexdetected
Mounting and Cable Attachment
iConverter modules are hot-swappable and can be
installed into any chassis in the iConverter family.
1. Carefully slide the iConverter module into the
installation slot, aligning the module with the
installation guides. NOTE: Ensure that the module is
firmly seated against the backplane.
2. Secure the module by securing the panel fastener
screw (attached to module) to the chassis front.
3. Attach the UTP port via a category 5 cable to a
1000BASE-T, 100BASE-TX or 10BASE-T Ethernet
device.
4. Attach the fiber port via an appropriate multimode
orsingle-modefibercable to a 1000BASE-X Ethernet
device. The iConverter transmit (Tx) must attach to
the receive side on other device; the receive (Rx)
must attach to the transmit.
5. When using single-fiber (SF) media converter models,
the Tx wavelength on one end has to match the Rx
wavelength on the other. Note that based on this
guideline, the SF media converter models must be used
in pairs, such as the 8530-1 matched with the 8531-1.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and exclusive
remedies.Omnitronshall notbeliable for anydirect,indirect, special,
incidental,orconsequentialdamages,whetherbased on contract,tort,
oranylegal theory.
Form: 040-08520-001E 9 /07
BOARD MOUNTED DIP-SWITCHES
10
10-100
MANX
=
=
=
UTP 10Mbps
UTP 10/100Mbps
Manual Crossover
BPAEN
BPBEN
MAN
=
=
=
Backplane “A” Enabled
Backplane “B” Enabled
P1 Manual FO
100
1000
AX
=
=
=
MAN = P2 Manual UTP
P2 Auto Negotiate
UTP 100Mbps
UTP 1000Mbps
Auto Crossover
AN
=
Off
Off
P1 Auto Negotiate
ON
HD = P2 Half Duplex
FD
=P2 Full Duplex
AN
=
Fig.4 Board MountedDIP-Switches
Backplane AEnable DIP-Switch (BPAEN)
Whenthe“BPAEN”DIP-Switchisinthe“ON”position(right),
the iConverter GX/T module A backplane Ethernet port is
enabled.Thisportallowsconnectivitytoanadjacentmodule.
When the “BPAEN” DIP-Switch is in the “Off” position (left,
factory setting), the A port is isolated from the backplane.
Backplane B Enable “BPBEN” DIP-Switch
When the Backplane B Enable “BPBEN” DIP-Switch is
in the “ON” position (right), the iConverter GX/T module
B backplane Ethernet port is enabled. This port allows
connectivityto an adjacent module. When the “BPBEN”
DIP-Switch is in the “Off” position (left, factory setting),
the B port is isolated from the backplane.
Fiber Auto/Manual P1 “AN/MAN” DIP-Switch
Setting this DIP-Switch to P1 Auto-Negotiate “AN”
(factory setting) enables the Fiber Port to determine
duplex mode automatically. If the connected device
cannot provide the proper signal to indicate its own
mode of operation, this DIP-Switch should be set to P1
Manual “MAN.” This feature allows connections with
devices that do not auto-negotiate properly.
NOTE: When the fiber port is in Manual Mode,
sometimes a link-up will not occur with other devices.
Both devices must be set to the same mode (either
Manual or Auto-Negotiate) for the link-up to occur.
UTP Auto/Manual P2 “AN/MAN” DIP-Switch
Setting the P2 Auto/Manual Negotiate DIP-Switch to
Auto-Negotiate “AN” (factory setting) enables the
UTP port to determine the speed and duplex mode
automatically. If the connected device cannot provide
the proper signal to indicate its own mode of operation,
this DIP-Switch should be set to P2 Manual “MAN.”
This feature allows connections with devices that do
not auto-negotiate properly.
NOTE: Attaching an auto-negotiating UTP port to a non
auto-negotiating (manual/forced/hard-coded) UTP port
mayresultinanunpredictableport setting with excessive
collisions and poor link performance. When operating in
manualmode, both matingportsMUSTbe set manuallyto
thesamespeedand duplex mode.
Gigabitdevicestypically function only in Auto-Negotiate
Mode. 1000 Manual Mode is not a valid mode and will
resultinanundefined response. Use Manual mode only
when selecting the 10 or 100 mode.
UTP Full/Half-Duplex P2 “FD/HD” DIP-Switch
When the UTP P2 Auto/Manual DIP-Switch (described
above) is in the P2 Manual “MAN” position, the UTP P2
Full/Half Duplex “FD/HD” DIP-Switch selects the duplex
mode for the UTP port. When set to Full-Duplex “FD”
(factory setting), the UTP port operates in Full-Duplex
mode. When P2 is set to Half-Duplex “HD,” the UTP
port operates in Half-Duplex mode.
UTP 10/100 P2 “10/100” DIP-Switch
When the UTP P2 Auto/Manual DIP-Switch is in the
Auto-Negotiate “AN” position and the “10-100/1000”
DIP-Switch (described below) is set to “10-100,” the
“10/100” DIP-Switch determines the highest speed of
the UTP P2 port in the following manner:
Whenthe“10/100”DIP-Switch is set to the “100” position,
P2operatesat100Mbps or less, depending on the speed
of the connected device.
When the “10/100” DIP-Switch is set to the “10” position,
P2 operates only at 10Mbps.
Whenthe UTPP2 Auto/ManualDIP-Switchisinthe Manual
“MAN” position and the UTP “10-100/1000”
DIP-Switch (described below) is set to “10-100,” the
“10/100” DIP-Switch determines the speed of the UTP P2
port. When set to “100” (factory setting), the UTP port will
operate at 100Mbps. When set to “10,” the UTP port will
operate at 10Mbps.
UTP 10-100/1000 P2 “10-100/1000” DIP-Switch
When the P2 “AN/MAN” DIP-Switch is set to the
Auto-Negotiate “AN” position, the “10-100/1000”
DIP-Switch operates in the following manner:
When set to “1000,” P2 operates at 1000Mbps or less,
depending on the speed of the connected device.
Whenset to the “10-100” position, thespeed is selected
by the UTP “10/100” DIP-Switch.
When the P2 “AN/MAN” DIP-Switch is set to Manual
“MAN” mode, the “10-100/1000” DIP-Switch must be
set to the “10-100” position and the speed is selected
by the “10/100” DIP-Switch.
NOTE: Setting the “10-100/1000” DIP-Switch to the
“1000” position when in Manual mode is not permitted
(per the IEEE 802.3 standard) and will result in
unpredictable port behavior.
Auto/Manual Crossover Enable P2 “AX/MANX”
DIP-Switch
When the Manual/Auto Crossover Enable DIP-Switch
is set to Auto Crossover “AX” (factory default), the
front panel crossover switch is disabled and the RJ-45
crossover is selected automatically. When it is set to
Manual Crossover “MANX,” the front panel RJ-45
Manual Crossover DIP-Switch is enabled to allow a
manual setting in either Crossover or Straight-Through
connection.
Page 9 Page10 Page11 Page12
Page15 Page16
TECHNICALSUPPORT:
Forhelpwiththisproduct,contactourTechnical Support:
Phone: (949) 250-6510
Fax: (949) 250-6514
Address: Omnitron Systems Technology, Inc.
140 Technology Dr., #500
Irvine, CA 92618 USA
URL: www.omnitron-systems.com
Model Type GX/T
Protocols 10BASE-T, 100BASE-TX,
1000BASE-T,
1000BASE-SX/LX
UTP
Connectors RJ-45
Fiber
Connectors SC, MT-RJ, LC, Single-Fiber
SC
Controls
BP Enable, X-Over, LS/LP,
RFD, SFD, UTP Auto/Man,
10/100/1000, UTP FDX/HDX,
F/O Auto/Man
LED Displays Power, FO link, UTP link, Auto,
FDX/HDX, 10/100/1000
Dimensions W:0.85" x D:4.5" x H:2.8"
Weight 8 oz.
Compliance UL, CE, FCC Class A
Power
Requirement 1.4A @ 3.3VDC (typical)
Temperature Standard: 0 to 50º C
Wide: -40 to 60º C
Storage: -40 to 80º C
Humidity 5 to 95% (non-condensing)
Altitude -100m to 4000m
MTBF (hrs) 830,000