Introduction
Thank you for purchasing the V640-series CIDRW System.
Please observe the following points when operating the V640-series CIDRW System:
• Allow the CIDRW System to be installed and operated only by qualified specialist with a sufficient knowledge
of electrical systems.
• Please read and understand the contents of this manual before using the system.
• After reading this manual, store it in a convenient location for easy reference whenever necessary.

ÇÕǹÇ?Ç ëÊ 1èÕ ëÊ 2èÕ ëÊ 3èÕ ëÊ 4èÕ
INTRODUCTION
SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6
Introduction
SECTION 1
SECTION 2
SECTION 3
SECTION 4
SECTION 5
SECTION 6
Table of Contents/Precautions in Using the Products
Product Outline
Installation and Connections/Wiring
Preparing for Communications
Reading from/Writing to ID Tags
Troubleshooting
Appendix
CIDRW System
V640-HAM11-V3 Amplifier Unit
V640-HAM11-L Amplifier Unit
V640-HS61 CIDRW Head
V640-HS62 CIDRW Head
V700-L22 CIDRW Controller
V700-L11 Link Unit
User's Manual

2
INTRODUCTION
Precautions in using the product
CIDRW System
User’s Manual
INTRODUCTION
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you
have any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one
year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-
INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY
BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF
PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is
asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING
THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED,
STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR
INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR
RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT
OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated
products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of
products in the customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and
limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the
suitability of the products in combination with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an
exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the
products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not
described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment,
amusement machines, vehicles, safety equipment, and installations subject to separate industry or government
regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND
THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.

3
CIDRW System
User’s Manual
INTRODUCTION
Precautions in using the product
INTRODUCTION
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not
constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual
application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant
construction changes are made. However, some specifications of the product may be changed without any notice. When
in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your
request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased
products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are
shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us
before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this
document to another, please copy or transmit it in its entirety.

4
INTRODUCTION
Precautions in using the product
CIDRW System
User’s Manual
INTRODUCTION
To Users of the V700-L21 CIDRW Controller
The V700-L22 CIDRW Controller complies with the 2003 edition of the SEMI E99 standard. The V700-
L21 CIDRW Controller cannot simply be replaced with the V700-L22. To replace the V700-L21 with the V700-L22, the
control programming for the CIDRW Controller must be updated as described in this manual.
■Main Differences from the V700-L21
• Added Attributes
The CIDRW attributes defined as CarrierIDOffset and CarrierIDlength in the 2003 edition of the SEMI
E99 standard have been added. With the V700-L22, the user can now specify as attributes the position
of the MID in the ID Tag, and the data length.
Refer to Support Attributes p.156.
• Changed Message Specifications
The 2003 edition of SEMI E99 adds a format definition for the data item MID in the message specifica-
tions. The specifications of the data item MID have changed in the V700-L22.
Refer to Message Specifications p.74.
• Added Data Area Access Function
A function for specifying ID Tag data area access destinations as offset addresses has been added to
the V700-L22. The V700-L21 divides the data area into 8-byte units called segments, and reads and
writes data to each segment. Besides this, the V700-L22 also allows you to specify offset addresses
relative to the first address in the ID Tag data area, so that data can be read and written in units of one
byte.
Refer to Message Specifications p.74.
• Replacing the V700-L21 with theV700-L22
The following settings are required to replace the V700-L21 with the V700-L22.
(1) Set the CarrierIDOffset and CarrierIDlength attributes.
Set CarrierIDOffset to 0 and set CarrierIDlength to the data length of the data item MID specified
by the ID write request (S18F11). If there is a mismatch between the CarrierIDlength attribute and
the MID length in the ID write request (S18F11), a CE (communications error) occurs, and no data
is written.
(2) Change the MID to data consisting of displayable ASCII characters only.
With the V700-L22, data that includes undisplayable ASCII characters cannot be read with an ID
read request (S18F9); an EE (execution error) occurs. Data including undisplayable ASCII charac-
ters in the MID cannot be specified with an ID write request (S18F11).
With the V700-L21, the MID to be read or written is assigned to an area fixed at 16 bytes. If the specified data length in the ID
write request (S18F11) is less than 16 bytes, NUL characters are added in internal processing to make the total 16 bytes. In
contrast, with the V700-L22, the accessible MID data occupies only the area specified by the CarrierIDOffset and
CarrierIDlength attributes. Data can be read or written only in the area specified by the attributes.

5
CIDRW System
User’s Manual
INTRODUCTION
Precautions in using the product
INTRODUCTION
Applicable Standards
The CIDRW System complies with the following international regulations and standards.
1. USA
FCC NOTICE
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired opera-
tion.
FCC WARNING
Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
Do not remove the ferrite core (TDK-EPC Type ZCAT2749-0430C:V640-HS62) installed on the cables to suppress RF
interference.
FCC Part15 subpart B
NOTICE
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the interference
at his own expense.
CAUTION
This device must be professionally installed.
Amplifier Unit CIDRW Head
FCC Part 15 Subpart C
FCC ID: E4EV640HAM11
V640-HAM11-V3 V640-HS61
FCC Part 15 Subpart C
FCC ID: E4EV640HAM11L
V640-HAM11-L V640-HS62

6
INTRODUCTION
Precautions in using the product
CIDRW System
User’s Manual
INTRODUCTION
2. Europe
3. Canada
This device complies with RSS-Gen of IC (Industry Canada) Rules.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation.
ICES-003
This class A digital apparatus complies with Canadian ICES-003.
Cet appareil numerique de la classe A est conforme a la norme NMB-003 du Canada.
Amplifier Unit CIDRW Head
(Radio and Telecommunication Terminal Equipment Directive 1999/5/EC) V640-HAM11-V3 V640-HS61
Radio:
EMC:
Safety:
EN 300 330-2
EN 301 489-1
EN 301 489-3
EN 61010-1
V640-HAM11-L V640-HS62
English Hereby, Omron, declares that this V640-HAM11-V3 / V640-HAM11-L is in compliance with the essential requirements and other relevant
provisions of
Directive 1999/5/EC.
Finnish Omron vakuuttaa täten että V640-HAM11-V3 / V640-HAM11-L tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä kosk-
evien direktiivin muiden ehtojen mukainen.
Dutch Hierbij verklaart Omron dat het toestel V640-HAM11-V3 / V640-HAM11-L in overeenstemming is met de essentiële eisen en de andere rele-
vante bepalingen van richtlijh 1999/5/EG.
French Par la présente Omron déclare que lappareil V640-HAM11-V3 / V640-HAM11-L est conforme aux exigences essentielles et aux autres dispo-
sitions pertinentes de la directive 1999/5/CE.
Swedish Härmed intygar Omron att denna V640-HAM11-V3 / V640-HAM11-L stär l överensstämmelse med de väsentliga egenskapskrav och övriga
relevanta bestämmelser som framgår av direktiv 1999/5/EG.
Danish Undertegnede Omron erklærer herved, at følgende udstyr V640-HAM11-V3 / V640-HAM11-L overholder de væsentlige krav og øvrige rele-
vante krav i direktiv 1999/5/EF.
German Hiermit erklärt Omron, dass sich dieser/diese/dieses V640-HAM11-V3 / V640-HAM11-L in Übereinstimmung mit den grundlegenden
Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet. (BMWi)
Greek ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Omron ΔΗΛΩΝΕΙ ΟΤΙV640-HAM11-V3 / V640-HAM11-L ΣΥΜΜΟΡΦΩΝΕΤΑΙ
ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ
ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ
Italian Con la presente Omron dichiara che questo V640-HAM11-V3 / V640-HAM11-L é conforme ai requisiti essenziali ed alle altre disposizioni
pertinenti stabilite dalla direttiva 1999/5/CE.
Spanish Por medio de la presente Omron declara que el V640-HAM11-V3 / V640-HAM11-L cumple con los requisitos esenciales y cualesquiera otras
disposiciones aplicables o exigibles de la Directiva 1999/5/CE.
Portuguese Omron declara que este V640-HAM11-V3 / V640-HAM11-L est conforme com os tequisitos essenciais e outras disposições da Directiva
1999/5/CE.
Amplifier Unit CIDRW Head
IC ID: 850J-V64HAM11 V640-HAM11-V3 V640-HS61
IC ID: 850J-V64HM11L V640-HAM11-L V640-HS62

7
CIDRW System
User’s Manual
INTRODUCTION
Precautions in using the product
INTRODUCTION
Applicable SEMI Standards
This CIDRW system complies with the following standards.
• SEMI E99 THE CARRIER ID READER/WRITER FUNCTIONAL STANDARD
• SEMI E5 EQUIPMENT COMMUNICATION STANDARD 2 MESSAGE CONTENT (SECS II)
• SEMI E4 EQUIPMENT COMMUNICATION STANDARD 1 MESSAGE TRANSFER (SECS I)
SEMI is the acronym for Semiconductor Equipment and Materials International.
SECS is the acronym for SEMI Equipment Communication Standard.

8
INTRODUCTION
Precautions in using the product
CIDRW System
User’s Manual
INTRODUCTION
●Definition of Precautionary Information
The following notation and alert symbols are used in this User's Manual to provide precautions required to
ensure safe usage of a V640-series CIDRW System. The safety precautions that are provided are extremely
important to safety. Always read and heed the information provided in all safety precautions.
The following signal words are used in this manual.
●Meanings of Alert Symbols
●Alert Statements in this Manual
Indicates a potentially hazardous situation which, if not avoided, will result in minor or
moderate injury, or may result in serious injury or death. Additionally there may be signif-
icant property damage.
Prohibition
Indicates general prohibitions for which there is no specific symbol.
The product is not designed or rated for ensuring the safety of persons.
Do not use it for such purposes.
Safety Precautions
WARNING
WARNING

9
CIDRW System
User’s Manual
INTRODUCTION
Precautions in using the product
INTRODUCTION
Please observe the following precautions for safe use of the products.
• Never use the product in an environment where combustible or explosivegas is present.
• Please separate from a high-pressure equipment and the power equipment to secure the safety of the operation and
maintenance.
• In the installation, please tighten the screw surely. (Recommended 1.2N·m)
• Please do not insert foreign bodies such as water and the wires from the space of the case.
• Please do not dismantle, repair or modify this product.
• Please process as industrial waste when you abandon this product.
• When you work on wiring and put on and take off cables, CIDRW head, please perform it after switching off this product.
• Provide enough space around this product for ventilation.
•Please avoid installing this product near the machinery (a heater, a transformer, large-capacity resistance) that has high
the calorific value. hen you felt abnormality to this product, and having switched it off.
Confirm the effects of radio waves on medical devices. The following guideline is from JAISA (Japan
Automatic Identification Systems Association).
This product is a reader-writer that uses radio waves for RFID equipment. The application
and location of this product may affect medical devices. The following precaution must be
observed in the application of the product to minimize the effects on medical devices.
Any person with an implanted medical device must keep the area where the device is
implanted at least 22 cm away from the antenna of a stationary or modular RFID device.
Precautions for Safe Use

10
INTRODUCTION
Precautions in using the product
CIDRW System
User’s Manual
INTRODUCTION
Please observe the following precautions to prevent failure to operate, malfunctions, or undesirable effects on
product performance.
■About installation Site
Do not install this product in the locations subject to the following conditions.
• Place where direct sunshine strikes.
• Place with corroded gas, dust, metallic powder, and salinity.
• Place with condensation due to rapid temperature fluctuations.
• Place with condensation due to high humidity.
• Place where vibration and impact more than being provided by specification are transmitted directly
to main body.
• Place with spray of water, oil, and chemical medicine.
• The working temperature is within the range stipulated in the specifications.
■About depositoty Site
• Please follow the save ambient temperature / humidity, and keep this product.
■About wiring
• Use the power supply voltage specified in this cocument.
• Ensure correct polarity when connecting to the +/- power supply terminals.
• Do not run high-voltage lines and power lines though the same conduit.
• To avoid static-induced failure, wear a wrist band or equivalent means to release a static charge
before touching a terminal or a signal line within a connector.
• In using this product in EU association states, the cable for DC power supply to this product must not
be extended over 3m.
• When you put on and take off a CIDRW head, please do not add excessive power to a connector.
• Please connect the correct CIDRW head to the amplifier unit.
■About cleaning
• Use alcohol to clean this product.
• Never use an organic solvent such as thinner, benzene, acetone or kerosene, as it will attack resin
components or case coating.
■Power and Graound Cables
• Use an appropriate ground. An insufficient ground can affect this product operation or result in dam-
age to this product.
■About the communication range and time
• Do the communication test with Transponder in the installation environment because the metal,
noise and ambient temperature around CIDRW head damage to the communication range and time.
• Install CIDRW head and ID tag in the appropriate distance because the communication range can
change by the difference of ID tag specifications.
Precautions for Correct Use

11
CIDRW System
User’s Manual
INTRODUCTION
Precautions in using the product
INTRODUCTION
■About mounting
• This product communicates with ID Tags using the 134 kHZ frequency band. Some transceivers,
motors, monitoring equipment, and power supplies (power supply ICs) generate electrical waves
(noise) that interfere with communications with ID Tags, If you are using the product in the vicinity of
any of these devices, check the effect on communications in advance.
• In order to minimize the effects of noise, ground nearby metal bodies with a grounding resistance not
exceeding 100 ohms.
• When mounting CIDRW Heads, tighten the screws tightly.(Recommended 0.6N·m)
• When multiple CIDRW Heads are mounted next to each other, communications performance could
be impaired by mutual interference. Read and follow the information in this manual on mutual inter-
ference when installing multiple heads.
Refer to page 126.
■Screw Locking Adhesive
• Screw locking adhesive (screw lock) may cause deterioration and cracking of resin parts; do not use
it for screws in resin parts or anywhere where resin washers are used.
■Communications with the Host Device
Communicate with the host device only after confirming that the CIDRW Controller has started. Also,
unstable signals may occur at the host interface when the CIDRW Controller is started. When initializ-
ing operation, clear the reception buffer at the host device or take other suitable methods to clear
unwanted signals.
■Startup Precaution
Never turn OFF the power supply while the CIDRW Controller is starting, including when power is
turned ON, when the mode is changed, or when the CIDRW Controller is being reset. Doing so may
damage the CIDRW Controller.

12
INTRODUCTION
Precautions in using the product
CIDRW System
User’s Manual
INTRODUCTION
Reading this Manual
Visual Aids
Indicates an explanation of a point that must be observed to ensure that the product is capable of its proper functions and perfor-
mance. Read this information carefully and follow the cautions. If the product is used incorrectly, data or the equipment itself
could be destroyed.
Indicates summaries of points of particular importance relating to product performance, e.g., points to note during operation and
advice on how to use the product.
Indicates the number of a page where related information can be found.
Indicates information for reference when you encounter a problem.
Indicator Status
The following symbols are used to show the status of the indicators on the CIDRW Controller and Amplifier
Units.
OFF
Flashing
ON

13
CIDRW System
User’s Manual
INTRODUCTION
Table of Contents
INTRODUCTION
Table of Contents
Table of Contents
SECTION 1 Introduction 1
To Users of the V700-L21 CIDRW Controller 4
Applicable Standards 5
Applicable SEMI Standards 7
Safety Precautions 8
Precautions for Safe Use 9
Precautions for Correct Use 10
Reading this Manual 12
Table of Contents 13
SECTION 2 Product Outline 15
What Is a CIDRW System 16
Features 17
System Configuration 18
Component Names and Functions 19
Flowchart for Getting Started 24
SECTION 3 Installation and Connections/Wiring 29
Installation 30
Connections and Wiring 35
SECTION 4 Preparing for Communications 51
Setting the Communications Conditions for the CIDRW Controller 52
Setting the Communications Conditions for Amplifier Units 65
Setting the Communications Conditions for Link Units 67
Communications Test 68
SECTION 5 Reading from/Writing to ID Tags 73
When SECS Is Used 74
When SECS Is Not Used 85

14
INTRODUCTION
Table of Contents
CIDRW System
User’s Manual
INTRODUCTION
Table of Contents
SECTION 6 Troubleshooting 99
When SECS Is Used 100
When SECS Is Not Used 106
SECTION 7 Appendix 113
Specifications and Dimensions 114
System Configuration Examples 119
Characteristic Data According to Conditions of Use 121
ID Tag Memory Maps 151
Regular Inspection 152
SECS Protocol Specifications 153
ASCII Code Table 158
Protective Construction 159
SECTION 8 Revision History 162

16
SECTION 1
What Is a CIDRW System
CIDRW System
User’s Manual
SECTION 1
Product Outline
What Is a CIDRW System
The CIDRW system writes data to, and reads data from, the carrier IDs (ID Tags) mounted on the carriers
(FOUP) in semiconductor manufacturing processes without contacting these ID Tags. CIDRW is the
abbreviation of Carrier ID Reader/Writer and this abbreviation is used throughout this manual.
Reading and writing information such as models, process instructions, lots, and inspection results to and from
ID Tags makes it possible to manage work instruction information from a host device.
Example: Management of information in semiconductor and wafer manufacturing processes
ID Tag
(holder is separate)
CIDRW Head
Reading and writing
information
• Model information
• Process instruction
information
• Completion
information
• Lot information
• Inspection results
Etc.
Host
Amplifier Unit
CIDRW Controller

17
CIDRW System
User’s Manual
SECTION 1
Features
SECTION 1
Product Outline
Features
■CIDRW Systems That Conform to SEMI Standards (SEMI E99, E5, E4)
List of Applicable Standards
• SEMI E99 THE CARRIER ID READER/WRITER FUNCTIONAL STANDARD
• SEMI E5 EQUIPMENT COMMUNICATION STANDARD 2 MESSAGE CONTENT (SECS II)
• SEMI E4 EQUIPMENT COMMUNICATION STANDARD 1 MESSAGE TRANSFER (SECS I)
SEMI is the acronym for Semiconductor Equipment and Materials International.
SECS is the acronym for SEMI Equipment Communications Standard.
The V640-HAM11-V3 or V640-HAM11-L will automatically detect the model and read/write data for RI-TRP-
DR2B(-30) and RI-TRP--WR2B(-30) ID Tags manufacturer by Texas Instruments.
Host
SECS I/II
CIDRW Controller
V700-L22
Amplifier Unit
V640-HAM11-V3
CIDRW Head
V640-HS61
ID Tag
RI-TRP-DR2B(-30)
RI-TRP-WR2B(-30)
(Made by Texas
Instruments)
CIDRW System Conforming to SEMI Standards
RS-232C RS-232C
• V640-HAM11-V3
• V640-HAM11-L
Host
SECS I/II
CIDRW Controller
V700-L22
Amplifier Unit
V640-HAM11-L
CIDRW Head
V640-HS62
ID Tag
RI-TRP-DR2B(-30)
RI-TRP-WR2B(-30)
(Made by Texas
Instruments)
CIDRW System Conforming to SEMI Standards
RS-232C RS-232C
The V640-HS61 CIDRW Head can be connected to V640-HAM11-V3 Amplifier Units to communi-
cate with ID Tags.
The V640-HS62 CIDRW Head can be connected to V640-HAM11-L Amplifier Units to communicate
long-distance with ID Tags. The functions of the V640-HAM11-L Amplifier Unit are the same as the
functions of the V640-HAM11-V3 Amplifier Unit.

18
SECTION 1
System Configuration
CIDRW System
User’s Manual
SECTION 1
Product Outline
System Configuration
When SECS Is Used
Communications with the host device is possible using the SECS protocol.
When SECS Is Not Used
Communications with the host device follow the OMRON proprietary protocol.
The Amplifier Units are connected directly to the host device without using a CIDRW Controller.
Refer to the following page for connection examples for more than one Amplifier Units or for connection examples for
using the V700-L11 Link Unit.
page 119
Using Link Units (V700-L11) to make connections makes it possible to remove and replace just the rele-
vant Amplifier Unit while leaving the power to the CIDRW system on in the event of a failure or during
maintenance.
The CIDRW Heads are the
antennas for reading the
carrier IDs from the ID Tags
and writing the carrier IDs.
The Amplifier Units con-
trol the CIDRW Heads.
This is a host computer,
equipment controller, etc.
CIDRW Head
V640-HS61
Amplifier Unit
V640-HAM11-V3
CIDRW Controller
V700-L22
Host
Multiple Amplifier Units
are controlled in
response to commands
(SECS) from the host
device.
RS-232C
SECS I/II RS-232C
CIDRW Head
V640-HS62
Amplifier Unit
V640-HAM11-L
CIDRW Controller
V700-L22
Host
RS-232C
SECS I/II RS-232C
The CIDRW Heads are the
antennas for reading the
carrier IDs from the ID Tags
and writing the carrier IDs.
The Amplifier Units con-
trol the CIDRW Heads.
This is a host computer,
equipment controller, etc.
CIDRW Head
V640-HS61
Amplifier Unit
V640-HAM11-V3
Host
RS-232C
OMRON proprietary protocol
CIDRW Head
V640-HS62
Amplifier Unit
V640-HAM11-L
Host
RS-232C
OMRON proprietary protocol
This manual suits for next models
6
Table of contents
Other Omron Amplifier manuals

Omron
Omron E3X-DA-N series User manual

Omron
Omron E9NC-TA Series User manual

Omron
Omron E3XDAC21S2M User manual

Omron
Omron F10-C20 User manual

Omron
Omron E3X-SD Series User manual

Omron
Omron E3Z-B61 2M User manual

Omron
Omron SMARTSTEP2 User manual

Omron
Omron E3X-DRT21 User manual

Omron
Omron V640 User manual

Omron
Omron E3X-SD Series User manual

Omron
Omron E3X-DA-S User manual

Omron
Omron V640 Series User manual

Omron
Omron E3NX-FA11AN User manual

Omron
Omron E3X-MDA11 User manual

Omron
Omron K7L-AT50 User manual

Omron
Omron E3X-NA - User manual

Omron
Omron E3X-CN11 User manual

Omron
Omron V600-HA User manual

Omron
Omron E3X-DA-N series User manual

Omron
Omron E3X-NA - User manual