A-444 Advanced Photoelectric Sensors
Rating/performance
Amplifier Units
* If 8 or more Units are installed side-by-side, the response time will be 350 s max.
Pre-wired Connector type
Type Standard models High-speed de-
tection models
Mark-detecting
models
Water-resistant
models Standard models
Water-resistant mod-
els (M8 Connector)
Model
NPN
output
E3X-NA11 E3X-NA11F E3X-NAG11 E3X-NA11V E3X-NA6 E3X-NA14V
Item PNP
output
E3X-NA41 E3X-NA41F E3X-NAG41 E3X-NA41V E3X-NA8 E3X-NA44V
Light source (wave
length) Red LED (680 nm) Green LED
(520 nm) Red LED (680 nm)
Power supply volt-
age 12 to 24 VDC ±10%, ripple (p-p): 10% max.
Current consumption 35 mA max.
35 mA max. (at
power supply
voltage 24 VDC)
35 mA max.
Control output Load current 50 mA (residual voltage 1 V max. each) Open collector output type (depends on the NPN/PNP out-
put format) Light-ON/Dark-ON switch selectable
Response time
Operation or re-
set: 200 s max. *
Operating: 20 s
max. Reset: 30 s
max.
200 s max. for operation and reset respectively (See note.)
Sensitivity adjust-
ment 8-turn endless adjuster (with indicator)
Protective circuits
Reverse polarity
protection, out-
put short-circuit
protection, mutu-
al interference
prevention (opti-
cally synchro-
nized)
Reverse polarity
protection, out-
put short-circuit
protection
Reverse polarity protection, output short-circuit protection, mutual interfer-
ence prevention (optically synchronized)
Timer function OFF-delay timer: 40 ms (fixed)
Ambient illuminance Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max.
Ambient temperature Operating: Groups of 1 to 3 Amplifiers: -25 to +55°C, Groups of 4 to 11 Amplifiers: -25 to +50°C, Groups of 12 to
16 Amplifiers: -25 to +45°C Storage: -30 to +70°C (with no icing and condensation)
Ambient humidity Operating/Storage: 35% to 85% RH (with no condensation)
Insulation resistance 20 M min. at 500 VDC
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute 500 VAC at
50/60 Hz for
1 minute
Vibration resistance 10 to 55 Hz with a 1.5 mm double amplitude for 2 hrs each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2for 3 times each in X, Y, and Z directions
Protective structure IEC 60529 IP50 (with Protective Cover attached)
IEC 60529 IP66
(with Protective
Cover attached)
IEC 60529 IP50
(with Protective
Cover attached)
IEC 60529 IP66
(with Protective
Cover attached)
Connection method Pre-wired models (standard length: 2 m) Connector type
M8 connector
Weight (Packed
state) Approx. 100 g Approx. 110 g Approx. 55 g 65 g
Material
Case PBT (polybutylene terephthalate)
Cover Polycarbonate Polyethersul-
fone (PES)
Polycarbonate
Polyethersul-
fone (PES)
Accessories Instruction manual