E3X-SD/-NA
3
Ratings and Specifications
Amplifier Units
✽1. When there are 8 or more E3X-NA Amplifiers mounted side-by-side, the response time will be 350 μs max.
✽2. Mutual interference prevention is effective when E3X-SD/-NA-series Amplifiers are gang-mounted without other E3X-series Amplifiers.
✽3. Water-resistant models and models with connectors have a dielectric strength of 500 VAC.
✽4. Add 10 g for water-resistant models.
Amplifier Unit Connectors (Wire-saving Connectors)
Type
Digital display and direct key setting Bar display and adjuster setting
Standard models Standard models High-speed detection
models Water-resistant models
Model E3X-SD@E3X-NA@E3X-NA@FE3X-NA@V
Item
Light source (wavelength) Red, 4-element LED (625 nm) Red LED (680 nm)
Power supply voltage 12 to 24 VDC ±10%, ripple (p-p): 10% max.
Power consumption/
Current consumption
960 mW max.
(Power supply voltage: 24 V,
Current consumption: 40 mA max.)
(Power supply voltage: 12 V,
Current consumption: 80 mA max.)
960 mW max. (Current consumption: 40 mA max.)
Control output
Open-collector output (NPN or PNP)
Load power supply: 26.4 V max.,
Load current: 50 mA max.
(Residual voltage: 1.5 V max.)
Light-ON/Dark-ON mode selector
Open-collector output (NPN or PNP)
Load power supply: 26.4 V max.,
Load current: 50 mA max.
(Residual voltage: 1 V max.)
Light-ON/Dark-ON mode selector.
Response time Operate or reset: 200 μs max. (✽1) Operate: 20 μs max.
Reset: 30 μs max.
Operate or reset:
200 μs max. (✽1)
Sensitivity adjustment UP/DOWN direct key setting, teaching
with/without a workpiece, automatic teaching 8-turn sensitivity adjuster (with indicator)
Protection circuits
Power supply reverse polarity protection,
output short-circuit protection,
output reverse polarity protection
Power supply reverse polarity protection,
output short-circuit protection
Timer function --- No timer, OFF-delay timer; or Timer selector (timer time: 40 ms (fixed))
Mutual interference
prevention Up to 5 Amplifiers (optically synchronized) (✽2) None Up to 5 Amplifiers (optical-
ly synchronized) (✽2)
Ambient illumination
Receiver side
Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Number of gang-mounted
Amplifiers 16 max. (The ambient temperature specification depends on the number of gang-mounted Amplifiers.)
Ambient temperature
range
Operating: Groups of 1 to 3 Amplifiers: −25°C to 55°C
Groups of 4 to 11 Amplifiers: −25°C to 50°C
Groups of 12 to 16 Amplifiers: −25°C to 45°C
Storage: −30°C to 70°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 MΩ. min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute (✽3)
Vibration resistance Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2, for 3 times each in X, Y and Z directions
Degree of protection IEC 60529 IP50 (with Protective Cover attached)
IEC 60529 IP66
(with Protective Cover at-
tached)
Connection method Pre-wired (standard cable length: 2 m), or connector
Weight (packed state) (✽4) Pre-wired model: Approx. 100 g, Model with connector: Approx. 55 g
Material Case Polybutylene terephthalate (PBT)
Cover Polycarbonate (PC) Polyethersulfone (PES)
Accessories Instruction manual
Item Model E3X-CN11 E3X-CN12
Rated current 2.5 A
Rated voltage 50 V
Contact resistance
20 mΩmax. (20 mVDC max., 100 mA max.)
(The above figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the
cable.)
Number of insertions Destruction: 50 times (for connection to the Amplifier Unit and the adjacent Connector)
Material Housing Polybutylene terephthalate (PBT)
Contact Phosphor bronze/gold-plated nickel
Weight (packed state) Approx. 55 g Approx. 25 g