
A-433E3X-DA-N
E3X-DA-N
General
• The four types of teaching given below are available.
• Once setting is made, operation is performed in the preset status thereafter. When a teaching error occurs, the level indicators
flash in red. Restart setting from the beginning.
Maximum Sensitivity Setting
One-point without-object teaching
Note: If one-point teaching is not available because the difference in level is too
fine, try two-point teaching.
Operation Mode Selector
There is no operation mode selector for twin-output models.
Two-point With/Without-object Teaching
Note: With and without work may be in any order.
Pin-point teaching (for positioning)
When teaching is performed (SET mode)
SET
CH1 CH2
Twin-output models only Select the channel to be adjusted using the channel selection switch.
Set the mode selector to .
SET
Proce-
dure
Operation
1 Set the mode selector to SET.
2Press the TEACH button for 3
seconds min.
3
Setting is completed when the
red-lit level indicators turn to
green. Then they return to the
digital incident level display.
4 Set to RUN mode.
Proce-
dure
Operation
1 Set the mode selector to SET.
2Press the SET button once
(about 1 s).
3
Setting is completed when the
red level indicators are turned
ON. They then return to the digi-
tal incident level display.
4 Set to RUN mode.
5The threshold is automatically
set with the object.
Operating mode
Operation
Light ON L ON
Dark ON D ON
SET
3s
TEACH
(red)
(green)
RUN
SET
1s
TEACH
(red)
RUN
Object
ON
Output
(Factory-set)
L
D
Proce-
dure
Operation
1Set the mode selector to SET.
2With the work present, press the
SET button once (about 1 s).
3The level indicators are lit red.
4If no work is pending, press the
SET button once (about 1 s).
5
Setting is completed when the
green indicators are turned ON.
Then they return to the digital in-
cident level display.
6Set to RUN mode.
Proce-
dure
Operation
1Set the mode selector to SET.
2If no work is pending, press the
SET button once (about 1 s).
3The level indicators are lit red.
4
Place the object in the desired
position, and press the TEACH
button for 3 seconds min.
5
Setting is completed when the
green indicators are turned ON.
Then they return to the digital in-
cident level display. (Red indica-
tors start flashing if setting is not
OK.)
6 Set to RUN mode.
SET
Object
1s
TEACH
(red)
1s
TEACH
(green)
RUN
SET
1s
TEACH
(red)
Object
3s
TEACH
(green)
RUN