sp-0
sp-1
sp-2
sp-3
ev-m
ev-1
ev-2
psel
u-no
bps
len
sbit
prty
sdwt
mspu
hbu
hbl
hbh
hsu
hsl
hsh
ocu
ocl
och
Multi-SP
Heater current 1 value monitor
Leakage current 1 monitor
Communications writing
Heater current 1 value monitor
Heater burnout detection 1
Heater Overcurrent Detection 1
Leakage current 1 monitor
HS alarm 1
Set point 0
Set point 1
Set point 2
Set point 3
Number of multi-SP uses
Event input 1 allocation
Event input 2 allocation
Protocol selection
Unit No.
Communications baud rate
Data bits
Stop bits
Communications parity
Send wait time
Multi-SP use
HBA ON/OFF
Heater burnout latch
Heater burnout hysteresis
HS alarm use
HS alarm latch
HS alarm hysteresis
Heater Overcurrent Use
Heater Overcurrent Latch
Heater Overcurrent Hysteresis
0 to 3
0.0 to 55.0
0.0 to 55.0
ON, OFF
0.0 to 55.0
0.0 to 50.0
0.0 to 55.0
0.0 to 55.0
0.0 to 50.0
Set point lower limit to set point upper limit
Set point lower limit to set point upper limit
Set point lower limit to set point upper limit
Set point lower limit to set point upper limit
0 to 2
0 to 10
0 to 10
Compoway/F(Sysway)、Modbus
0 to 99
1.2, 2.4, 4.8, 9.6, 19.2, 38.4,57.6
7, 8
1, 2
None, even, odd
0 to 99
ON, OFF
ON, OFF
ON, OFF
0.1 to 50.0
ON, OFF
ON, OFF
0.1 to 50.0
ON, OFF
ON, OFF
0.1 to 50.0
0
OFF
0.0
50.0
0
0
0
0
1
0
1
Compoway/F
1
9.6
7
2
Even
20
OFF
ON
OFF
0.1
ON
OFF
0.1
ON
OFF
0.1
NA
A
A
NA
A
A
A
A
A
EU
EU
EU
EU
NA
NA
NA
NA
NA
kbps
Bits
Bits
NA
ms
NA
NA
NA
A
NA
NA
A
NA
NA
A
Operation
level
Adjustment
level
Initial setting
level
Communi-
cations
setting
level
Advanced
function
setting
level
Level Setting
Display
Set value/monitor value Default Unit
• Die Kommunikationseinstellungen (z. B. Kommunikationsgeschwindigkeit) müssen mit denen
des Zentralrechners übereinstimmen.
• Folgende Kommunikationsprotokolle werden unterstützt: CompoWay/F (Sysway) und Modbus.
■Kommunikations (RS-485,RS-232C)
• Les réglages des communications (par exemple la vitesse de communication) doivent être les
mêmes que ceux de l'ordinateur hôte.
• Les protocoles de communication suivants sont pris en charge : CompoWay/F (Sysway) et
Modbus.
■Communication (RS-485,RS-232C)
• Bezüglich Einzelheiten für den Betrieb des Temperaturreglers, schlagen Sie bitte im Bedienungshandbuch nach.
• Schlagen Sie im ntlp:confirm Handbuch name:ntlp E5CN/AN/EN/GN Communications User's Manual
(E5CN/AN/EN/GN Kommunikationen Bedienerhandbuch) für Einzelheiten zu den Kommunikationen nach.
•
Pour plus de détails sur le fonctionnement de la commande de température, reportez-vous au Manuel d'utilisation.
•
Pour plus de détails concernant les communications, reportez-vous au Manuel d'utilisation des communications E5CN/AN/EN/
GN.
■ Ereignis-Eingänge
■
Alarm für das Ausbrennen der Heizung/
Alarm zur Erkennung von Überstrom der Last/HS-Alarm (Stromwandler1)
E5GN
Digitaler Regler
Kommunikation
Ereignis-Eingänge
Alarm für das Ausbrennen der Heizung
Alarm zur Erkennung von Überstrom der Last
HS-Alarm (Stromwandler1)
Bedienungsanleitung
Vielen Dank, dass Sie sich für ein Produkt von OMRON
entschieden haben. Um den sicheren Betrieb dieses
Gerätes zu gewährleisten, darf es nur von qualifiziertem
Personal mit Fachkenntnissen über elektrische Geräte
bedient werden. Lesen Sie dieses Handbuch
aufmerksam durch, bevor Sie das Gerät in Betrieb
nehmen, und bewahren Sie anschließend das
Handbuch in Greifnähe auf.
OMRON CORPORATION
©All Rights Reserved
Übergang zum Kommunikations-Einstellebene
Die Taste mindestens drei Sekunden drücken, um vom Betriebsebene zum
Konfigurationsebene umzuschalten; die Taste noch einmal drücken, um zum
Kommunikations-Einstellebene zu schalten.
Finden des Erkennungsstroms für Einphasenstrom.
• Verwenden Sie die folgende Formel zur Etablierung eines Wertes für den Erkennungsstrom:
Wenn mehr als ein Heizer an CT angeschlossen ist, verwenden Sie den Ausbrennstrom des
Heizers mit dem kleinsten Strom als Ausbrennwert. (Wenn alle Heizer den gleichen Stromwert
verwenden, den Wert verwenden der für einen Heizer als Ausbrennwert gilt.)
•Sicherstellen, daß die folgenden Bedingungen erfüllt werden:
Heizer von weniger als 10.0 A: Normaler Heizwert -- Heizer-Ausbrennwert
≥
1 A
Die Erkennungsfunktion ist unzuverlässig für Stromstärken von weniger als 1 A.
Heizer von 10.0 A oder mehr: Normaler Heizwert -- Heizer-Ausbrennwert
≥
2.5 A
Die Erkennungsfunktion ist unzuverlässig für Stromstärken von weniger als 2.5 A.
•Der Erkennungsstrom kann auf einen Wert zwischen 0.1 und 49.9 A eingestellt werden.
Heizungs-Ausbrennen wird nicht erkannt, wenn der Erkennungsstrom auf 0.0 oder 50.0 gestellt
ist. Durch Einstellung des Wertes auf 0.0 wird der Heizungs-Ausbrennwert ausgeschaltet; durch
Einstellung auf 50.0 wird der Alarm eingeschaltet.
•Der Aggregatwert der Normalstromwerte der Heizer sollte nicht mehr als 50.0 A betragen. Wenn
der Wert 55.0 A überschreitet, zeigt der "Heizstrommonitor" Parameter "ffff".
Die getrennt erhältlichen CTs verwenden: E54-CT1 oder E54-CT3.
Erkennungseinstellung = Normaler Heizstromwert + Heizungs-Ausbrennstromwert
2
■ Entrée événement
E5GN
Contrôleur numérique
Communication
Entrée événement
Alarme de dysfonctionnement de l’élément chauffant
Alarme de détection de surintensité dans le élément chauffant
Alarme HS (TC1)
Nous vous remercions d'avoir acheté ce produit OMー
RON. Afin de garantir une utilisation du produit en toute
sécurité, seul un professionnel qualifié en matière
d'électricité et connaissant les dispositifs électriques
peut le manipuler. Lisez soigneusement ce manuel
avant d'utiliser le produit et conservez-le près de vous
lors de son utilisation.
OMRON CORPORATION
©All Rights Reserved
Passage au niveau de configuration de la communication
Maintenez la touche enfoncée pendant au moins 3 secondes pour passer du
niveau des opérations au niveau de configuration initiale; appuyez à nouveau
sur la touche pour passer au niveau de configuration de la communication.
■
Alarme de dysfonctionnement de l’élément chauffant/
Alarme de détection de surintensité dans le élément chauffant/Alarme HS (TC1)
Recherche du courant de détection pour l'alimentation monophasée
• Utilisez la formule suivante pour introduire une valeur de détection de courant:
Si plus d'une résistance est connectée au CT, utilisez le courant de claquage de la résistance
en prenant le courant le plus bas comme valeur de claquage (si tous les résistances utilisent la
même intensité de courant, utilisez la valeur applicable à une résistance comme valeur de
claquage).
•
Assurez-vous que les conditions suivantes sont remplies :
Résistances de moins de 10.0A : valeur du courant de la résistance en condition normale - valeur du courant
de claquage de la résistance ≥ 1A
La fonction de détection n'est pas fiable pour des courants inférieurs à 1A.
Résistances de 10.0A ou plus : valeur du courant de la résistance en condition normale - valeur du courant
de claquage de la résistance ≥ 2.5A
La fonction de détection n'est pas fiable pour des courants inférieurs à 2.5A.
• La valeur de détection de courant peut être comprise entre 0.1 et 49.9A. Le claquage de
résistance ne sera pas détecté si la valeur de détection de courant est égale à 0.0 ou à 50.0.
Introduire la valeur 0.0 aura pour effet de mettre l'alarme de claquage de résistance hors fonction;
introduire la valeur 50.0 aura pour effet de mettre l'alarme de claquage de résistance en fonction;
•
L'ensemble des valeurs du courant normal des résistances ne devrait pas dépasser 55.0A. Si la
valeur est supérieure à 55.0A, le paramètre « état du courant des filaments » indiquera "ffff".
Utilisez les CT disponibles séparément : E54-CT1 ou E54-CT3.
Configuration de la détection = Valeur du courant de la résistance en condition normale + valeur du courant de claquage du élément chauffant
2
Maintenez les touches
+ enfoncées pendant
au moins 3 secondes
Umschaltung der Einstellebenen
Passage d'un niveau à un autre
La commande s'arrête.
Contrôle en cours
Contrôle interrompu
Changement de niveau
Niveau des
opérations
Niveau de
réglage des
communications
Niveau de
réglage initial
Affiché uniquement
pour les modèles
avec communications.
Niveau de
protection
Niveau de
réglage
Sous tension
Niveau de réglage
de la fonction
avancée
Saisissez
le mot de
passe
(-169).
Appuyez sur
(durant
moins d'une
seconde).
Appuyez sur
(durant moins d'une
seconde).
Appuyez
sur
durant au
moins une
seconde.
Maintenez les touー
ches + enー
foncées pendant
au moins 1 seconー
de
drücken
(kürzer als 1 Sekunde)
mindeー
stens 3 Seー
kunden
gedrückt
halten
mindeー
stens 1 Seー
kunde
gedrückt
halten
und mindeー
stens 1 Sekunde
gedrückt halten
und mindestens 3 Seー
kunden gedrückt halten
Maintenez la
touche enー
foncée penー
dant au moins
3 secondes
Maintenez la
touche enー
foncée penー
dant au moins
1 seconde
• The communications settings (e.g., communications speed) must be the same as those of the
host computer.
• The following communications protocols are supported: CompoWay/F (Sysway) and Modbus.
■Event input
Transition between levels
• Refer to the User's Manual (Cat. No. H156) for details on Temperature Controller Operation.
• Refer to the E5CN/AN/EN/GN Communications User's Manual (Cat. No. H158) for details on communications.
E5GN
Digital Controller
Communication
Event Input
Heater Burnout Alarm/Heater Overcurrent Detection Alarm
Heater Short Alarm (CT1)
■
Heater Burnout Alarm/Heater Short Alarm (CT1)
■
Communication (RS-485,RS-232C)
Establishing a value for the detection current for Single phase Power
• Use the following formula to establish a value for the detection current:
• When more than one heater is connected to the CT, use the burnout current of the heater using
the smallest current as the burnout value. (If all the heaters use the same size current, use the
value applicable to one heater as the burnout value.)
• Ensure that the following conditions are satisfied:
Heaters of less than 10.0A: Normal heater current value - Heater burnout current value
≥
1A
The detection function is unreliable for currents of less than 1A.
Heaters of 10.0A or more: Normal heater current value - Heater burnout current value
≥
2.5A
The detection function is unreliable for currents of less than 2.5A.
• The detection current can be set to anything from 0.1 to 49.9A. Heater burnout will not be
detected if the detection current is set to 0.0 or 50.0. Setting the value to 0.0 will have the effect
of switching the heater burnout alarm off; setting the value to 50.0 will have the effect of
switching the alarm on.
• The aggregate of the heaters' normal current values should not be more than 50.0A. If the value
exceeds 55.0A, the "heater current monitor" parameter will show "ffff".
CTs: E54-CT1 or E54-CT3. (available separately)
Detection setting = Normal heater current value + Heater burnout current value
2
Press
(less than 1 second)
Hold down
for at least
1 second
Hold down
for at least
3 seconds
Hold
+ M down
for at least 1 second
Hold
+ M down
for at least 3 seconds
Control will stop.
Control in progress
Control stopped
Level change
Operation
level
Communication
setting level
Initial setting level
Displayed only for models
with communications.
Protect level
Adjustment
level
Press :
(less than
1 second).
Press :
(less than
1 second).
Advanced function
setting level
Input
password
(-169).
■
Options Settings List (Only parameters for option unit are listed.)
Thank you for purchasing the OMRON E5GN tempera-
ture controller. Read this manual carefully before using
the controller and always keep it close at hand while the
controller is in use.
OMRON CORPORATION
©All Rights Reserved
Instruction Manual
EN
Contact input
No-contact input
Number of inputs
Functions
Input specifications
2 points max.
Multi-SP Set Point Setting, RUN/STOP, AUTO/MANUAL, Program Reset/Start,
Direct/Reverse Operation, 100%AT execute/cancel, 40%AT execute/cancel, Setting
Change Enabled/Disabled, Communications Writing Enabled/Disabled, Latch Cancel
ON:1kΩ max., OFF:100kΩ min.
ON:residual voltage1.5V max., OFF:leakage current 0.1mA max.
ON terminal current:Approx. 7mA(short-circuit)
Transition to Communication setting level
Press the key for at least three seconds to move from the operation
level to the initial setting level; press the key once again to move to
the communication setting level.
Power on
1178067-3A
GN5
Die Regelung wird angehalten
Regelung findet statt
Regelung gestoppt
Pegeländerung
Betriebsebene
Konfigurationsebene
Kommunikations-
einstellebene
Wird nur für Modelle mit
Kommunikationen angezeigt.
Schutzebene
Parameter-Ebene
Einstellebene der
erweiterte
Konfiguration
Geben
Sie das
Passwort
(-169) ein.
■
Optionen – Einstellungsliste (Nur Parameter für die Option Unit sind aufgelistet.)
■
Liste des réglages des options (Ne sont listés que les paramètres pour l'unité optionnelle.)
DE
Manuel d'instruction
FR
Drücken Sie
auf
(kürzer als
1 Sekunde).
Drücken Sie
mindestens
1 Sekunde
lang auf .
Eingeschaltet
Multi-SP
Heizungsstrom 1 Wert kontrollieren
Kriechstrom 1 kontrollieren
Kommunikation schreiben
Heizungsstrom 1 Wert kontrollieren
Heizung Ausbrennen Erkennung 1
Erkennung von Überstrom der Last 1
Kriechstrom 1 kontrollieren
HS-Alarm 1
Einstellungspunkt 0
Einstellungspunkt 1
Einstellungspunkt 2
Einstellungspunkt 3
Anzahl der Multi-SP-Verwendungen
Ereigniseingangszuweisung 1
Ereigniseingangszuweisung 2
Protokollwahl
Kommunikationseinheit Nr.
Kommunikationsgeschwindigkeit
Kommunikationsdatenlänge
Kommunikationsstoppbit
Kommunikationsparität
Sendewartezeit
Multi-SP-Verwendung
HBA EIN/AUS
Heizung Ausbrennen Riegel
Heizung Ausbrennen Hysterese
HS-Alarm Verwendung
HS-Alarm Riegel
HS-Alarm Hysterese
Verwendung von Überstrom Alarm
Riegel des Überstroms Alarm
Hysterese des Überstroms Überstrom alarms
Betriebspegel
Einstellpegel
Ursprünglicher
Konfiguratioー
nsebene
Kommuni-
kations-
einstellpegel
Einstellpegel
für
erweiterte
Funktion
0
OFF
0.0
50.0
50.0
0
0
0
0
1
0
1
Compoway/F
1
9.6
7
2
Gerade
20
OFF
ON
OFF
0.1
ON
OFF
0.1
ON
OFF
0.1
Nicht erhältlich
A
A
Nicht erhältlich
A
A
A
A
A
EU
EU
EU
EU
Nicht erhältlich
Nicht erhältlich
Nicht erhältlich
Nicht erhältlich
Nicht erhältlich
kbps
Bits
Bits
Nicht erhältlich
ms
Nicht erhältlich
Nicht erhältlich
Nicht erhältlich
A
Nicht erhältlich
Nicht erhältlich
A
Nicht erhältlich
Nicht erhältlich
A
m-sp
ct1
lcr1
cmwt
ct1
hb1
oc1
lcr1
hs1
sp-0
sp-1
sp-2
sp-3
ev-m
ev-1
ev-2
psel
u-no
bps
len
sbit
prty
sdwt
mspu
hbu
hbl
hbh
hsu
hsl
hsh
ocu
ocl
och
0 bis 3
0,0 bis 55,0
0,0 bis 55,0
ON, OFF
0,0 bis 55,0
0,0 bis 50,0
0,0 bis 55,0
0,0 bis 55,0
0,0 bis 50,0
Einstellungspunkt Untergrenze zu Einstellungspunkt Obergrenze
Einstellungspunkt Untergrenze zu Einstellungspunkt Obergrenze
Einstellungspunkt Untergrenze zu Einstellungspunkt Obergrenze
Einstellungspunkt Untergrenze zu Einstellungspunkt Obergrenze
0 bis 2
0 bis 10
0 bis 10
Compoway/F(Sysway), Modbus
0 bis 99
1.2, 2.4, 4.8, 9.6, 19.2, 38.4,57.6
7, 8
1, 2
Keine, gerade, oder ungerade
0 bis 99
ON, OFF
ON, OFF
ON, OFF
0,1 bis 50,0
ON, OFF
ON, OFF
0,1 bis 50,0
ON, OFF
ON, OFF
0,1 bis 50,0
Pegel Einstellung
Display
Wert einstellen/Wert kontrollieren
Voreinstellung
Einheit
Kontakteingang
Kontaktloser Eingang
Max. 2 Punkte
Multi-SP., Bankauswahl (nur bei Modellen mit dem Suffix "H"), RUN/STOP, AUTO/
MANUELL, Programm zurückstellen/starten, Direkter/umgekehrter Betrieb,
100%AT aktiviert/deaktiviert, 40%AT aktiviert/deaktiviert,Einstellungsänderung
aktiviert/deaktiviert, Schreiben der Kommunikationen aktiviert/deaktiviert, Riegel Abbruch
ON:Max. 1kΩ , OFF:Min. 100kΩ
ON:Restspannung Max. 1.5V , OFF:Leckstrom Max. 0.1mA
Klemmenstrom EIN:Ca.7mA(Kurzschluss)
Anzahl der Eingaben
Funktionen
Eingangsspezifikationen
SP multiple
Indicateur de la valeur du courant de l’élément chauffant 1
Indicateur de courant de fuite 1
Ecriture de communications
Indicateur de la valeur du courant de l’élément chauffant 1
Détection du dysfonctionnement de l’élément chauffant 1
Détection de surintensité dans le élément chauffant 1
Indicateur de courant de fuite 1
Alarme HS 1
Consigne 0
Consigne 1
Consigne 2
Consigne 3
Nombre d’entrées consignes utilisées
Assignation de l’entrée événement 1
Assignation de l’entrée événement 2
Sélection du protocole
No de l'unité
Vitesse de communication
Longueur des données
Bit d'arrét
Parité
Durée d'attente de l'envoi
Utilisation du SP multiple
Activation/désactivation HBA
Acquittement du dysfonctionnement de l’élément chauffant
Hystérésis du dysfonctionnement de l’élément chauffant
Utilisation de l’alarme HS
Verrou de l’alarme HS
Hystérésis de l’alarme HS
Utilisation surintensité élément chauffant
Verrou de surintensité dans le l'élément chauffant
Hystérésis de la surintensité dans le l'élément chauffant
Niveau de
fonctionnement
Niveau
d’ajustement
Niveau de
sélection
initiale
Niveau de
réglage
des
communications
Niveau de
réglage
des
fonctions
0
OFF
0.0
50.0
50.0
0
0
0
0
1
0
1
Compoway/F
1
9.6
7
2
Paire
20
OFF
ON
OFF
0.1
ON
OFF
0.1
ON
OFF
0.1
Non disponible
A
A
Non disponible
A
A
A
A
A
EU
EU
EU
EU
Non disponible
Non disponible
Non disponible
Non disponible
Non disponible
kbps
Bits
Bits
Non disponible
ms
Non disponible
Non disponible
Non disponible
A
Non disponible
Non disponible
A
Non disponible
Non disponible
A
m-sp
ct1
lcr1
cmwt
ct1
hb1
oc1
lcr1
hs1
sp-0
sp-1
sp-2
sp-3
ev-m
ev-1
ev-2
psel
u-no
bps
len
sbit
prty
sdwt
mspu
hbu
hbl
hbh
hsu
hsl
hsh
ocu
ocl
och
de 0 à 3
de 0,0 à 55,0
de 0,0 à 55,0
ON, OFF
de 0,0 à 55,0
de 0,0 à 50,0
de 0,0 à 55,0
de 0,0 à 55,0
de 0,0 à 50,0
Limite inférieure de la Consigne sur la limite supérieure de la Consigne
Limite inférieure de la Consigne sur la limite supérieure de la Consigne
Limite inférieure de la Consigne sur la limite supérieure de la Consigne
Limite inférieure de la Consigne sur la limite supérieure de la Consigne
0 to 2
0 to 10
0 to 10
Compoway/F(Sysway), Modbus
0 to 99
1.2, 2.4, 4.8, 9.6, 19.2, 38.4,57.6
7, 8
1, 2
Aucune, paire, impaire
0 to 99
ON, OFF
ON, OFF
ON, OFF
de 0,1 à 50,0
ON, OFF
ON, OFF
de 0,1 à 50,0
ON, OFF
ON, OFF
de 0,1 à 50,0
Niveau Réglage
Affichage
Valeur définie/valeur au moniteur
Par défaut
Unité
Entrée cantact
Entrée sans cantact
2 points maxi.
SP multiple., Sélection de banc (uniquement pour les modèles à suffixe "-H"),
RUN/STOP, AUTO/MANUEL, Remise à zéro/Démarrage du programme,
Fonctionnement direct/inversé, 100%AT Exécution/Annulation, 40%AT Exécution/
Annulation, Changement de réglage activé/désactivé, Ecriture de communications
activée/désactivée, Annulation du verrou
ON:1kΩ maxi., OFF:100kΩ min.
ON:tension résiduelle 1.5V maxi., OFF:courant de fuite 0.1mA maxi.
Courant aux bornes activé:environ 7mA(Court-circuit)
Nombre d'entrées
Fonctions
Spécifications d'entrée