stop the search, enjoy the ride
VARISPEED L7
The frequency inverter for lifts
Advanced Industrial Automation
The Omron-Yaskawa L7 Varispeed frequency inverter is built with
the focus firmly on reliability, ease-of-use and smooth performance.
Designed specifically for the lift market, the L7 series ensures that
lifts exceed the ride quality and safety demands of the market.
Available in power ratings from 3.7kW up to 55kW, the Varispeed L7
offers a cost-effective solution for all your lift requirements.
The Varispeed L7 is based on years of experience in inverter design,
and uses the latest proven technology to provide reliability and safety.
Furthermore, lift-specific features have been developed in response
to market needs. These standard features include direct control
of motor brake and motor contactor, short floor operation, door
opening control and hardware base block. In addition, both open
loop and closed loop vector control is available in the Varispeed L7,
providing the optimum speed regulation to suit the application.
Ease of use has been considered from the outset. An LCD
operator is available to provide plain text set-up and
monitoring of the inverter, while a non-rotating auto-tuning
function ensures the inverter can obtain all of the required
motor information without the need to decouple the motor
from the gearbox. Option cards are available to integrate
the L7 series into communication networks such
as CANopen, DeviceNet or Profibus-DP.
DeviceNet is a registered trademark
of Open DeviceNet Vendors Association.
Made to drive lifts
High performance
The L7 provides best ride comfort through precise speed
regulation and best levelling accuracy through unique
slip compensation.
High reliability
Omron-Yaskawa’s frequency inverters are currently being
used in over 100,000 lifts around the world! The L7 ensures
3 million full load starts during its lifetime.
Ease of use
The L7 inverter has all the relevant lift, function and sequence
parameters. This allows the inverter to be easily adjusted
to every controller sequence available on the market, making
it ready for immediate use. Non-rotating auto-tuning measures
all the necessary motor equivalent circuit data at start-up,
so there is no need to disconnect the lift for acquiring data
on vector control. This also saves your setting up time.
In addition, the PC commissioning tool SYSDrive Configurator
ensures easy set-up.
Cost effective
The high current rating of the L7, even at high temperatures,
enables you to choose the same kW rating for inverters and
motors. The dedicated lift functionality saves you time during
installation and start-up. The L7’s four built-in relays provide
output signals that eliminate the need for extra components
in the lift controller panel. The relays control the motor brake
and contactors directly.
Safety built in
Even in the event of a power failure the L7 will continue
to bring the lift to a correct stop using a battery or an UPS
(uninterruptible power supply); the choice is yours.
The L7 features advanced IGBT protection, with five levels
of over-current protection available before an over-current
failure occurs. A brake and contactor control/supervision
circuit guarantees safe operation.
Key features
•High rated output current
•Direct control of motor brake and contactor
•Dedicated Lift sequence
•Emergency evacuation (battery operation)
•Short floor operation
•Door opening control
•Auto-tuning at standstill
•Connectivity to all popular field busses
•PCconfiguration and commissioning tool
General specifications of L7 frequency inverter series
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.europe.omron.com
For the Middle East, Africa and other countries in Eastern Europe, Tel: +31 (0) 23 568 13 00 www.europe.omron.com
Authorised Distributor: Automation and Drives
• Programmable logic controllers • Networking
• Human-machine interfaces • Inverter drives • Motion control
Industrial Components
• Electromechanical relays • Timers • Counters • Sockets
• Programmable relays • Low voltage switch gear • Power supplies
• Temperature & process controllers • Solid-state relays
• Panel indicators • Level controllers • Industrial switches • Pushbutton switches
Sensing and Safety
• Photoelectric sensors • Proximity sensors • Rotary encoders
• Vision systems • RFID systems • Safety switches
• Safety relays • Safety sensors
Austria
Tel: +43 (0) 1 80 19 00
www.omron.at
Belgium
Tel: +32 (0) 2 466 24 80
www.omron.be
Czech Republic
Tel: +420 267 31 12 54
www.omron.cz
Denmark
Tel: +45 43 44 00 11
www.omron.dk
Finland
Tel: +358 (0) 9 549 58 00
www.omron.fi
France
Tel: +33 (0) 1 49 74 70 00
www.omron.fr
Germany
Tel: +49 (0) 2173 680 00
www.omron.de
Hungary
Tel: +36 (0) 1 399 30 50
www.omron.hu
Italy
Tel: +39 02 32 681
www.omron.it
Netherlands
Tel: +31 (0) 23 568 11 00
www.omron.nl
Norway
Tel: +47 (0) 22 65 75 00
www.omron.no
Poland
Tel: +48 (0) 22 645 78 60
www.omron.com.pl
Portugal
Tel: +351 21 942 94 00
www.omron.pt
Russia
Tel: +7 095 745 26 64
www.russia.omron.com
Spain
Tel: +34 913 777 900
www.omron.es
Sweden
Tel: +46 (0) 8 632 35 00
www.omron.se
Switzerland
Tel: +41 (0) 41 748 13 13
www.omron.ch
Turkey
Tel: +90 (0) 216 474 00 40
www.omron.com.tr
United Kingdom
Tel: +44 (0) 870 752 08 61
www.omron.co.uk
Although we strive for perfection, Omron Europe BV and/or its subsidiary and affiliated companies do not warrant
or make any representations regarding the correctness or completeness of the information described in this document.
We reserve the right to make any changes at any time without prior notice.
SF4P_Varispeed_L7_EN_INT01_1003
Model: CIMR-L7 L744P0 L745P5 L747P5 L74011 L74015 L74018 L74022 L74030 L74037 L74045 L74055
Applicable motor output (kW) 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55
Rated output current at 45° (A) 11 14 18 27 34 41 48 65 80 96 128
Rated output current at 55° (A) 10.2 13.1 16.8 25.2 31.7 38 44.8 60.8 74.7 89.6 119.3
Rated output current 10kHz, at 45° (A) 10.2 13.0 16.7 25.1 31.6 38.1 44.6 48.8 60.0 72.0 96.0
Carrier frequency
Maximum output voltage 3-phase 380V-480V (limited by input voltage)
Rated input voltage and frequency 3-phase 380V-480V, 50/60Hz
Speed accuracy Vector control with PG: 0.01%
Open loop vector control: 0.2%
Braking transistor Built-in Optional
Control I/O 8 Digital inputs (PNP/NPN), 1 analogue input, 4 relay outputs, 3 option ports
5kHz default (adjustable up to
10kHz with derating)
8kHz default
(adjustable up to 15kHz with derating)

Other manuals for L7

1

This manual suits for next models

22

Other Omron DC Drive manuals

Omron SMARTSTEP 2 SERIES User manual

Omron

Omron SMARTSTEP 2 SERIES User manual

Omron OMNUC FND Series User manual

Omron

Omron OMNUC FND Series User manual

Omron SIGMA-5 User manual

Omron

Omron SIGMA-5 User manual

Omron Varispeed E7 User manual

Omron

Omron Varispeed E7 User manual

Omron SYSDRIVE 3G3MV-AB001 User manual

Omron

Omron SYSDRIVE 3G3MV-AB001 User manual

Omron NJ-series User manual

Omron

Omron NJ-series User manual

Omron SJDE-APA-OY User manual

Omron

Omron SJDE-APA-OY User manual

Omron SYSMAC CXONE-ALC-EV2 Series User manual

Omron

Omron SYSMAC CXONE-ALC-EV2 Series User manual

Omron R88M-K Series User manual

Omron

Omron R88M-K Series User manual

Omron SMARTSTEP SERVO DRIVE Quick guide

Omron

Omron SMARTSTEP SERVO DRIVE Quick guide

Omron SJDE-ANA-OY User manual

Omron

Omron SJDE-ANA-OY User manual

Omron Omnus FND-X Series User manual

Omron

Omron Omnus FND-X Series User manual

Omron W-SERIES User manual

Omron

Omron W-SERIES User manual

Omron SMARTSTEP User manual

Omron

Omron SMARTSTEP User manual

Omron SYSDRIVE 3G3JV User manual

Omron

Omron SYSDRIVE 3G3JV User manual

Omron 3G3RX Series User manual

Omron

Omron 3G3RX Series User manual

Omron SIGMA-5 User manual

Omron

Omron SIGMA-5 User manual

Omron SMARTSTEP 2 R7D-BP01H Quick guide

Omron

Omron SMARTSTEP 2 R7D-BP01H Quick guide

Popular DC Drive manuals by other brands

Bosch Active Line Original operating instructions

Bosch

Bosch Active Line Original operating instructions

oventrop Aktor M operating instructions

oventrop

oventrop Aktor M operating instructions

elero VariEco L RH Operating and assembly instructions

elero

elero VariEco L RH Operating and assembly instructions

CENTENT CN0124 operating manual

CENTENT

CENTENT CN0124 operating manual

Eurotherm Drives 590 DRV Digital product manual

Eurotherm Drives

Eurotherm Drives 590 DRV Digital product manual

GFA ELEKTROMAT ST 9.24-25.00 installation instructions

GFA

GFA ELEKTROMAT ST 9.24-25.00 installation instructions

ABB BUE Maintenance Guide

ABB

ABB BUE Maintenance Guide

MR TAPMOTION TD ISM operating instructions

MR

MR TAPMOTION TD ISM operating instructions

Moons' MSSTAC6 user manual

Moons'

Moons' MSSTAC6 user manual

Lenze L-force 8400 Series Mounting instructions

Lenze

Lenze L-force 8400 Series Mounting instructions

Masterflex P/S 850-3010 operating manual

Masterflex

Masterflex P/S 850-3010 operating manual

MRMC QUAD BOX quick start guide

MRMC

MRMC QUAD BOX quick start guide

ML Accessories 24DC100M Installation & maintenance manual

ML Accessories

ML Accessories 24DC100M Installation & maintenance manual

Nidec Unidrive M100 Installation sheet

Nidec

Nidec Unidrive M100 Installation sheet

Leroy-Somer GEARLESS Z2 Installation and Maintenance

Leroy-Somer

Leroy-Somer GEARLESS Z2 Installation and Maintenance

YASKAWA GA50U Series Installation & Primary Operation

YASKAWA

YASKAWA GA50U Series Installation & Primary Operation

Rtelligent 3R110PLUS user manual

Rtelligent

Rtelligent 3R110PLUS user manual

Danfoss VLT AutomationDrive FC 300 instruction manual

Danfoss

Danfoss VLT AutomationDrive FC 300 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.