manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Omron
  6. •
  7. Timer
  8. •
  9. Omron H2A - User manual

Omron H2A - User manual

This manual suits for next models

1

Other Omron Timer manuals

Omron H3BA-N User manual

Omron

Omron H3BA-N User manual

Omron H5S - User manual

Omron

Omron H5S - User manual

Omron H5F - User manual

Omron

Omron H5F - User manual

Omron H3CR-A8 User manual

Omron

Omron H3CR-A8 User manual

Omron H5CR series User manual

Omron

Omron H5CR series User manual

Omron H5CZ User manual

Omron

Omron H5CZ User manual

Omron H3CR-F - User manual

Omron

Omron H3CR-F - User manual

Omron H3DE-M2 User manual

Omron

Omron H3DE-M2 User manual

Omron H5CN User manual

Omron

Omron H5CN User manual

Omron H3CR User manual

Omron

Omron H3CR User manual

Omron H3CR-A8E User manual

Omron

Omron H3CR-A8E User manual

Omron H5CX User manual

Omron

Omron H5CX User manual

Omron H3BF-N8 User manual

Omron

Omron H3BF-N8 User manual

Omron H5BR Series User manual

Omron

Omron H5BR Series User manual

Omron H2C User manual

Omron

Omron H2C User manual

Omron H3DE User manual

Omron

Omron H3DE User manual

Omron H5CZ User manual

Omron

Omron H5CZ User manual

Omron H5L Series User manual

Omron

Omron H5L Series User manual

Omron H3RN User manual

Omron

Omron H3RN User manual

Omron H5CX User manual

Omron

Omron H5CX User manual

Omron H5AN Series User manual

Omron

Omron H5AN Series User manual

Omron H5F - User manual

Omron

Omron H5F - User manual

Omron H5S-B User manual

Omron

Omron H5S-B User manual

Omron H5CX-N - User manual

Omron

Omron H5CX-N - User manual

Popular Timer manuals by other brands

SATO TM-29 instruction manual

SATO

SATO TM-29 instruction manual

Full Gauge Controls ICEMATIC quick start guide

Full Gauge Controls

Full Gauge Controls ICEMATIC quick start guide

CEI Ultrak T-3 instructions

CEI

CEI Ultrak T-3 instructions

Raindrip R675CT Installation & programming

Raindrip

Raindrip R675CT Installation & programming

Intermatic P1131 owner's manual

Intermatic

Intermatic P1131 owner's manual

Profile 010200280 instruction manual

Profile

Profile 010200280 instruction manual

Gizmo T4 instructions

Gizmo

Gizmo T4 instructions

Tekmar Timer 031 Data brochure

Tekmar

Tekmar Timer 031 Data brochure

Daikin DST301B61 Operation manual

Daikin

Daikin DST301B61 Operation manual

sisel ENDA ETM2432 manual

sisel

sisel ENDA ETM2432 manual

B&Q TE103 Installation and use instructions

B&Q

B&Q TE103 Installation and use instructions

Hozelock AC Plus 2700 instructions

Hozelock

Hozelock AC Plus 2700 instructions

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

GIC

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

Emos EMT400F quick start guide

Emos

Emos EMT400F quick start guide

FarmTek Polaris operating instructions

FarmTek

FarmTek Polaris operating instructions

Citizen ME2 series instruction manual

Citizen

Citizen ME2 series instruction manual

Primex OneVue Sync B100 install guide

Primex

Primex OneVue Sync B100 install guide

Rain Bird Optima PRT-4 owner's manual

Rain Bird

Rain Bird Optima PRT-4 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
Motor Timer H2A
Miniature, High-performance Motor
Timer
Employs high-reliability bifurcated contacts for
output.
Moving
pointer provided in all types for
confirmation
of elapsed time.
Employs time-out and power ON indicators for all
types.
Wide variety of timing ranges from 5 s to 24 hrs.
Ordering Information
Operation/resetting
system
Internal connection
Time-limit
tt
Instantaneous
tt
Mounting
pgy
contact contact
Surface mounting
(see note 2)
T
ime-limit operation/
lf tti
Parallel motor and
lth ti
SPDT --- H2A
p
self-resetting
clutch connection
SPST-NO H2A-H
Note: 1.
Specify both the model number and supply voltage when ordering.
2.
Surface mounting models can be used as a flush mounting type by attaching an exclusive adapter (Y92F-40) to the timer
.
Specifications
Time Ranges
Rated
time
T
ime setting range
T
ime division
50 Hz 60 Hz
5 s
0.2 to 6 s 0.2 to 5 s
0.2 s
10 s
0.5 to 12 s 0.5 to 10 s
0.5 s
30 s
1 to 36 s 1 to 30 s
1.0 s
60 s
2 to 72 s 2 to 60 s
2.0 s
3 min 1/6 to 3 1/2 min 1/6 to 3 min
10.0 s
6 min 1/4 to 7 1/6 min 1/4 to 6 min
15.0 s
12 min 1/2 to 14 min 1/2 to 12 min
30.0 s
30 min 1 to 36 min 1 to 30 min 1.0 min
60 min 2 to 72 min 2 to 60 min 2.0 min
3 hrs
1/6 to 3 1/2 hrs
1/6 to 3 hrs
10.0 min
6 hrs
1/4 to 7 hrs 1/4 to 6 hrs
15.0 min
12 hrs
1/2 to 14 hrs 1/2 to 12 hrs
30.0 min
24 hrs
1 to 28 hrs 1 to 24 hrs
1.0 hrs
Ratings
Rated
supply voltage
100, 1
10, 200, or 220 V
AC (50 Hz), 100/1
10, 200/220 V
AC (60 Hz)
Operating voltage range
85% to 1
10% of rated supply voltage
Power consumption
Approx. 3 V
A
Control outputs
Standard type: 2 A at 250 V
AC, resistive load (cosφ
= 1)
Note:
The front panel of the timer is color-coded to identify the following supply voltage classifications:
100, 1
10 V
: Blue
200, 220 V
: Red
Other classes: Black
H2A H2A
2
Characteristics
Accuracy
of operating time
±
2% max.
〈±
3% max. for the 5-s model)
Setting error ±
5% max.
Reset time
0.3 s max.
Influence of voltage
±
1% max.
Influence of temperature
±
2% max.
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Dielectric strength
2,000 V
AC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts,
between contact and control circuit and between) contacts of dif
ferent polarities)
1,000 V
AC, 50/60 Hz for 1 min (between non-continuous contacts)
V
ibration resistance
Destruction:
16.7 Hz with 4-mm double amplitude
Malfunction:
10 to 55 Hz with 0.5-mm double amplitude
Shock resistance
Destruction:
1,000 m/s
2
(approx. 100G)
Malfunction:
100 m/s
2
(approx. 10G) (5G for lateral shocks)
Ambient temperature
Operating: –10°
C to 50
°C
Ambient humidity
Operating: 45% to 85%
Life expectancy
Mechanical:
1,000,000 operations min. (under no load at operating of 1,800 operations/hr)
Electrical:
See
“Engineering Data”
Motor life expectancy
20,000 hrs
Approved standards
UL (File No. E52800-US), CSA (File No. LR22310-US)
Weight
Approx. 170 g
Engineering Data
Switching operations (x 10 )
3
Load current (A)
Operation
Timing Chart
H2A H2A-H
Rt: Resetting time Rt: Resetting time
H2A H2A
3
Dimensions
Note: All
units are in millimeters unless otherwise indicated.
H2A/H2A-H
Note: F-shaped hook (PHC-1)
for PF085A and L-shaped
hook
(PHc-4) for PL08
are
supplied
with the timer
.
H2A(-H) with Adapter Panel Cutouts
Note: Back
connecting socket US08 and Y
-shaped hook
PHC-3
are supplied with the timers.
Panel Y92F-40 adapter for
flush mounting
(See note)
Accessories (Order Separately)
Track Mounted/Front Connecting Socket
PF085A Mounting
Holes
T
erminal Arrangement
(T
op V
iew)
Mounting Height of
T
imer with Socket
Adapter for Flush Mounting
Y92F-40 Panel Cutouts
Note: PF085A can be
used as a front
connecting
socket.
Two, 4.5 dia.
holes
Eight, M3.5 ×
7 sems Two, 4.5 dia. or M4 holes
Top View
Back Connecting Socket
PL08 (Solder Terminals) Mounting
Holes
T
erminal Arrangement
(Bottom View)
Mounting Height of
T
imer with Socket
Two, 2 dia. holes
Bottom View
H2A H2A
4
Mounting Track (Meets DIN EN50022)
PFP-100N/PFP-50N
(see note)
Note: This
dimension applied to PFP-50N.
End Plate
PFP-M PFP-S
Hold-down Clips (Attached)
PHC-1 For PF085A
Installation
Terminal Arrangement
H2A H2A-H
Precautions
Mounting
When
two or more timers are to be mounted in line, provide a dis
-
tance of more than 5 mm between the two adjacent timers.
When
two or more timers mounted in line are to be continuously en
-
ergized
at the same time after the set time has elapsed, be sure to
limit
the carry current to less than 1 A.
When using the timers at an ambient temperature of more than
40°C,
be sure to reset the
timers immediately after the set time has
elapsed.
Wiring
When
wiring, employ a multi-core cable
having a finished outer di
-
ameter of less than 10.5 mm, or insulated (twisted) wires with less
than
a 3 mm outer diameter
.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To
convert millimeters into inches, multiply by 0.03937. T
o convert grams into ounces, multiply by 0.03527.
Cat. No. L04-E1-8 In the interest of product improvement, specifications are subject to change without notice.
Printed
in Japan
0697-0.5C (0696)
OMRON Corporation
Systems
Components Division
28th Fl., Crystal T
ower Bldg.
1-2-27, Shiromi, Chuo-ku,
Osaka 540 Japan
Phone: 06-949-6012 Fax: 06-949-6021