Only CENTRALSEC User manual

SECURITY SYSTEM
User Manual

SE
CURITY
History
Version Date Changes
2.0 2017-03-08

Índice
INTRODUCTION ............................................................................................... 5
INTRUSION – interior peripheral and partial zones .............................................. 5
SECURITY – 24 hour zones ............................................................................... 6
ONLY SECURITY SYSTEM UNITS ........................................................................ 7
FEATURES ....................................................................................................... 8
FUNCTIONALITIES ........................................................................................... 9
24-hour security .............................................................................................. 9
24-Hour alarm routines .................................................................................... 9
Intrusion........................................................................................................ 10
CONTROLS AND INDICATIONS ......................................................................... 11
KEYPAD OVERVIEW ......................................................................................... 13
CONFIGURATION ............................................................................................ 14
MASTER MENU ............................................................................................... 14
Master code ................................................................................................... 14
Adding user codes ........................................................................................... 15
Deleting user codes ......................................................................................... 15
Defining the duress code ................................................................................. 16
Switching on/off the Automatic arming at night .................................................. 16
Switching the presence simulator on/off ............................................................ 16
Switching on/off Confirmed Alarm ..................................................................... 16
Programming phone numbers ........................................................................... 17
Defining Time and Date ................................................................................... 17
Changing the master code ............................................................................... 18
Exit the master menu ...................................................................................... 18
SYSTEM OPERATION ....................................................................................... 19
Arm and disarm the alarm ............................................................................... 19
Night mode .................................................................................................... 19
Partial mode ................................................................................................... 20
Restore Water supply ...................................................................................... 20
Restore Gas supply ......................................................................................... 20
Presence simulator .......................................................................................... 21
Confirmed alarm ............................................................................................. 22
Adding remote controls.................................................................................... 22
Removing remote controls ............................................................................... 22
Adding expansion units .................................................................................... 23
Removing expansion units ............................................................................... 23
COMMAND THROUGH TELEPHONE .................................................................... 24
Call to security central ..................................................................................... 24
Functions with user code ................................................................................. 24
Functions with master code .............................................................................. 25
INTEGRATION WITH AUTOMATION SYSTEM ....................................................... 26
Scenario “Leaving home” ................................................................................. 26
Scenario “Night” ............................................................................................. 27

SE
CURITY
Command “Partial” .......................................................................................... 27
Command “Close blinds” .................................................................................. 27
Command “Switch off lights” ............................................................................ 27
Programming of actions in case of alarm ............................................................ 28
Language selection ......................................................................................... 29
Adjusting the OLED display brightness ............................................................... 29
Software versions ........................................................................................... 29

INTRODUCTION
The ONLY Security system allows you to enjoy your home
knowing that you are always protected against leakage of gas
or water smoke or fire and intrusion. It also allows you to
control the major systems over the phone from wherever you
are.
If the security system is installed with ONLY automation the
system allows a number of extra features thanks to its total
integration with the rest.
The system has the following features:
• 24 hour protection against smoke and water and gas leaks
• Automatic protection against intrusion at night
• Full protection in your absence with simulated people in the
house
1)
• Manoeuvre to dissuade the intruder
1)
• Button for personnel emergency telephone call
• Two-way communication through telephone with voice
messages
• Control by phone of gas and water valves.
• Control by phone of lights blinds air conditioning and
other functions
1)
• Technical alarms
1) When installed with ONLY automation
This manual explains the features and how to use the system
from the standpoint of the user.
INTRUSION – interior, peripheral and partial zones
A good project of intrusion detection includes not only interior
protection but also peripheral protection. An intruder once
inside the house already destroyed something and it is good
policy to avoid it.
The ONLY security and automation systems together offer the
possibility of dissuading the intruder because any security
detector can also command any output of the automation
system.

SE
CURITY
Therefore a detector can also turn on lights switch on the
irrigation close all shutters or gates apart from the telephone
call to the owner or to the 24 hour security central.
For that the project engineer must predict the zones likely to
be used by the intruder protect them with detectors and plan
the dissuasion actions.
The ONLY security system divides the intrusion zones in
interior peripheral and partial.
Interior zones are the zones that must be protected when
people are not at home. Besides both kinds of zones are
divided in immediate and delayed zones. The delayed ones
are intended for zones of entry in the house allowing the user
the necessary time to enter his code opposed to the
immediate ones that immediately trigger the alarm.
eripheral zones are all those that should be armed during
the night when people are at home and sleeping. It’s for
example the magnetic contacts or even volumetric detectors
of other zones of the house not visited during the night.
artial zones are all those that must be protected even when
there are people at home. They are for example volumetric
detectors in garages or other outbuildings that usually are not
visited by people in the house during the day or night.
SECURITY – 24 hour zones
Security is not only intrusion detection; it is also protection of
goods and persons against accidental damage. A timely
warning of smoke can save lives as well as the closing of a
gas valve when leakage is detected.
The ONLY security central includes the command of the gas
and water valves to automatically avoid greater damage.
The smoke or fire detectors when triggered cause a very noisy
alarm calling all telephone numbers besides opening all the
shutters in order to facilitate the escape if necessary.
Movement detector
s
Entrance ways
Magnetic contacts on doors

ONLY SECURITY SYSTEM UNITS
The ONLY security system is composed by 4 different types of
units:
CENTRALSEC security central
C-4ZON-D-RF 4-zone expansion unit with RF receiver
OT-16SD security keyboard with OLED display
H-TX3B-RF RF remote-control
The CENTRALSEC is an 8-zone security central with telephone
dialler (PSTN) relays to drive valves to cut water and gas
supply as well as internal and external sirens. It features as
well an interface to the ONLY automation bus to allow
integration with domotics.
The C-4ZON-D-RF is a 4-zone expansion unit. It is intended
to connect up to 4 zone detectors and communicates with the
central through the security bus.
Up to 8 expansion units can be used in the system totalling
up to 40 different zones. It is equipped with a RF receiver.
The OT-16SD is a security keyboard with OLED that allows
users to interface with the system. Through them it is
possible to arm and disarm the system visualize certain
events define new users or change some system
parameters.
The H-TX3B-RF is a key-chain RF remote-control intended to
arm and disarm the system. It may also generate a personal
emergency call via telephone or be used to control other
automation units.

SE
CURITY
FEATURES
ONLY proposes a number of innovative features that improve
application and usability.
In order to avoid false alarms ONLY proposes the function
confirmed alarm: the sirens only sound in case of two or
more detections. Still the telephone communication takes
place at the first detection.
During the night when no more movement is detected inside
the house the system arms automatically in Night Mode
arming only the peripheral zones. In the morning as soon as
movement is detected in interior zones the alarm disarms
automatically. During the night it is possible to leave the
house without disarming the alarm if at least one interior
detector detects movement automatically rearming a bit
later.
When the house is also provided with the ONLY automation
system the user can choose arming the alarm with or
without simulation of people at home. When activated the
security central repeats the moves of the users made in the
house the day before simulating the occupation. Obviously
only the buttons defined by the user will be stored so that not
all the circuits of the house are used.
When power fails it is impossible to open a motorized shutter
because the motor blocks the movement. For that reason the
security system generates a special command that opens all
the shutters of the house in case of smoke or fire detection so
that escape is possible because it is likely to happen that
power goes off after a while. This function requires no
programming.
The telephone dialler allows not only the control and
verification of the state of the security system but also the
control of automation functions. The central can also be
connected to a 24-hour call centre using the Contact ID
protocol.

FUNCTIONALITIES
The system was conceived to operate automatically as much
as possible.
It differentiates between security zones (active 24 hours) and
intrusion zones (active when alarm is armed).
24-hour security
The security central or the expansion units verify continuously
the state of all the security detectors connected and report
any change immediately.
The following alarm routines are executed on trigger:
24-Hour alarm routines
Smoke - all sirens sound
- all shutters are open (with automation)
- all phone numbers are dialled
- gas valve immediately closed
- water valve immediately open and water
detection is disabled
Gas - gas valve immediately closed
- telephone numbers dialled with message
“gas leakage detection”
Water - water valve immediately closed
- telephone numbers dialled with message
“water leakage detection”
Panic - call to 24-hour central and to telephone
number memorized on position 6 with
message “Personal emergency”
The security central also verifies the presence of mains
supply. The central makes a call 30 minutes after mains
failure with the message “mains failure”. On the contrary it
also calls when the mains is back with the message “mains is
back”.
The alarm routines are interrupted when a valid user code or
remote control signal are detected.

SE
CURITY
Intrusion
The security central and the expander units check at all times
the status of the attached detectors reporting any changes to
the central.
In disarmed mode no intrusion detection causes an alarm.
If the system is armed the central identifies whether an
intrusion alarm is confirmed or not by analysing the number
of zones detected in a given time.
This information is reported to the user by voice message in
case of an alarm.
Upon determination of a single detection in a zone a non-
confirmed alarm is activated.
If the confirmed alarm function is activated the alarm
routine is as follows:
Total Mode - call to all telephone numbers
- message “Intrusion detection”
Night Mode - call to all telephone numbers
- message “Intrusion detection”
Partial Mode - call to all telephone numbers
- message “Intrusion detection”
This routine lasts for a period of alarm time defined by the
installer with a minimum of 3 minutes. If nobody switches the
alarm off (enter a valid code or pressing the disarm button on
the remote control) during this time the alarm will repeat the
routine but this time with activated sirens.
If in the meantime there is a detection in another zone a
confirmed alarm is activated:
Total mode - call to all telephone numbers
- message “Intrusion detection”
- switches on all sirens
Night mode - call to all telephone numbers
- message “Intrusion detection”
- switches on all sirens
Partial mode - call to all telephone numbers
- message “Intrusion detection”
- switches on all sirens
The routine is interrupted if a valid user code is entered or a
disarm button on the remote control is pressed.

CONTROLS AND INDICATIONS
The CENTRALSEC is equipped with a number of keys and LEDs
that inform and enable controlling of some of the features of
the system.
A – Power indication: green=230V red=battery
B – Water indication: blinking red = OFF
C – Gas indication: blinking red = OFF
D – Smoke/Fire alarm indication: red = ALARM
E – Indication LEDs 1 to 8
F – Status indication: green=disarm red=arm total
orange=arm night
G – Tamper indication: red = Tamper
H – Fault indication: red = fault detected
I – Expansion unit indication: red = triggered
J – Total alarm scenario key
K – Night alarm scenario key
L – Add key to add expansion units or RF remotes
M – OK key to acknowledge situations
The LEDs 1 to 8 inform different things depending on the
situation according the following table:

SE
CURITY
Indications
1 2 3 4 5 6 7 8
Zone 1
open
Zone 2
open
Zone 3
open
Zone 4
open
Zone 5
open
Zone 6
open
Zone 7
open
Zone 8
open
Centralsec
lid
Centralsec
zone
Expander
lost
Expander
zone
Keyboard
lost
- - -
Phone
line
System
voltages
Low
battery
Change
battery
Memory
test
Date
time
- -
In the case of an alarm the CENTRALSEC keeps an indication
on the zone that triggered the alarm that will be shown to the
user after entering a valid code.
The CENTRALSEC has the following indications:
-When the alarm was caused on a local zone the STATUS LED
blinks and the respective zone LED is ON.
-When the alarm was caused on an expansion zone the
EXPANSION LED blinks and the respective unit number is
shown on LEDs 1 to 8.
On the keyboard in case of an alarm the icon is shown on
the display simultaneously the internal beeper of the keypad
sounds.
The user will have to disarm the alarm with a valid code and
later it is necessary to validate each one of the occurred
events with button before being able to rearm the alarm.
The example in the figure besides indicates an intrusion alarm
triggered by zone 1 of the control panel.

KEY AD OVERVIEW
Navigation buttons inside menus.
Back
Up
Down
Next/Enter
Menu button for language selection display brightness change
and software versions visualization.
Buttons to select the Arming mode - Total, Night e
artial - pressed just after typing in the user code.
Arming in total mode does not requires to press the respective
button after the code.
Button is also used to configure the scenario activated
automatically when exit times finishes (e.g. switch-off lights
move rolling shutters down etc.).
Button can be used to activate a scenario like “arriving
home in the evening”.
Button sends a message ON/UP to the automation BUS that
can be used to switch on lights move blinds or roller shutters
up or others.
0..9
Numeric buttons to introduce user master or service code.
Button DOWN that can be used to configure a general
command blinds or roller shutters down.
Button OFF that can be used to configure a general command
to switch off all the lights.

SE
CURITY
CONFIGURATION
All system configuration can be done using the keyboard (OT-
16SD). Zone configuration and other technical parameters
must be configured by the installer using the keyboard or
using a specific application installed on a computer via the
RS232 connector.
This chapter explains how to set up the user settings using the
keyboard.
The system can only be operated after a valid code has been
entered. The number of digits of this code grants access to
normal users or to the system manager.
From the factory the system has the following definitions:
• Master code: 123456
• User code: 2580
Important note:
After installing the security system factory codes must be
modified.
MASTER MENU
The master menu allows the responsible for the installation to
define the following parameters:
• add and delete user codes
• define the duress code
• turn on or off the automatic night arming
• turn on or off the confirmed alarm
• turn on or off the simulator of people at home
• change phone numbers
• define date and time
• change the master code
While navigating in the menus the key cancels the action
and leaves the menu the key confirms the action. Any
change already confirmed is kept.
Master code
To access the master menu enter the 6-digit master code as
follows: ex. 123456
The keyboard will sound a confirmation beep and the list of
possible options is shown:
• Users
• Duress code
• Automatic arming
• Simulator

• Alarm confirmed
• Phone numbers
• Date and time
• Master code
Adding user codes
If no user code is yet defined the central has the code 2580.
When the first user code is defined the default code 2580 no
longer works. This code is reserved and cannot be used.
You can add up to 32 user codes in order to be able to identify
the operation of different persons in the event register.
To add a new user code select the option “Users” press key
select “New” press key type-in the desired 4-digit code
using the numeric keys in the keypad press to accept and
enter the code once more to confirm. A confirmation beep is
played if both entries are equal and the message “Code
accepted!” is shown.
If the entered code is not the same or if the used digits are of
an already existing code then the user is prompted to repeat
the process of a new code creation.
Deleting user codes
To delete a user code one by one select “Users” press key
select “Delete one by one” press enter the 4-digit code
you wish to delete press and repeat it once more to
confirm. A confirmation beep is played if the entry is correct
and the message “Code deleted!” is shown.
To erase all user codes select “User codes” press key
select “Delete all” press select “Yes” a confirmation beep
is played and the message “Codes deleted!” is shown.

SE
CURITY
Defining the duress code
The duress code should be entered instead of the user code
when the user is under threat or when requiring personal
assistance. This code disarms the system and makes a
personal emergency call to the telephone number saved on
memory 6.
To define the duress code select the option “Duress code”
press key type-in the desired 4-digit code using the
numeric keys in the keypad press to accept and enter the
code once more to confirm. If both entries are equal a
confirmation beep is played and the message “Code
accepted!” is shown.
Switching on/off the Automatic arming at night
Your installer can set the night period usually between 00:00
and 06:00. To activate the function automatic arming at night
select the option “Automatic arming” press key the
activation is signalized with
.
To deactivate this function select “Automatic arming” and
press
again
.
Switching the presence simulator on/off
To activate the function presence simulator select the option
“Simulator” press key the activation is signalized with
.
To deactivate this function select “Simulator” and press
again
.
Switching on/off Confirmed Alarm
To activate the function confirmed alarm select the option
“Alarm confirmed” press key the activation is signalized
with
.
To deactivate this function select “Alarm confirmed” and
press
again
.

rogramming phone numbers
To set or delete a phone number select "Phone numbers" and
press the key .
In the Phone Numbers submenu options 1 2 3 4 5 and
EMG are available representing the possible memories for
phone numbers.
Each memory location already has a fixed call type as
follows:
• #1 - normal voice call
• #2 - normal voice call
• #3 - normal voice call
• #4 - normal voice call
• #5 - normal voice call
• EMG - normal voice call for emergency or panic
Select the desired memory location press key and through
the alphanumeric keypad enter the phone number. To
confirm press key and the message "Phone stored" is
shown.
If you want to delete an existing phone number you have to
select the desired memory location press key scroll the
number till the last digit using key and press key to
delete the number digit by digit. When the number is totally
deleted press key the message “Phone stored” is displayed
to confirm the deletion.
Defining Time and Date
If the date and time is not defined it is not possible to
register events required to be able to verify what happened
behind. When arming the alarm without having defined date
and time you will hear an error sound indicating the failure
and on the display it will be shown the failure message “Date
and time”.
To set the date and time (e.g. January 8 2016 09:53) select
the “Date & time” option from the master menu and press key
. Enter the hour (e.g. 09) and minutes (e.g. 53) with 2-
digits always in the 24H format. Enter now the 4-digit year
(e.g. 2016) followed by the 2-digit month (e.g. 01) then also
the 2-digit day (e.g. 08).
Finally set the desired time zone
(GMT) using the key (e.g. 0 for Portugal) and press key
to finish.

SE
CURITY
Changing the master code
To change the master code select the "Master Code" option
press key and enter the 6-digit code. Repeat the code to
confirm it. If correct a confirmation beep will sound and the
message "Code Accepted!" is shown.
If the entered code is not the same you will need to re-enter
the code until it is valid.
Exit the master menu
To exit the master menu at any point press key .

SYSTEM O ERATION
Arm and disarm the alarm
When the system is disarmed enter a valid user code:
e.g.: 2580
A confirmation beep will sound and the exit time starts to run:
the keyboard will beep once per second while the counting
down time is shown on the display.
By default this time is 40 seconds.
If you enter a valid user code during the exit time then the
exit time stops and the system remains disarmed.
After the exit time finishes the alarm arms in TOTAL mode.
If you arrive home and the alarm is armed you will listen a
beep once per second: this is the entry time running.
By default this time is 40 seconds.
You must enter a valid user code to stop the entry time and
disarm the alarm otherwise the intrusion alarm will trigger
when the entry time finishes.
Exit time and entry time are programmable by the OLED
keypad or by the PC application.
Night mode
The night mode allows protection of the house arming only
the peripheral and partial zones allowing the circulation inside
the house.
If the function Automatic Night Arm is enabled you don’t
need any action: the alarm will arm during the defined night
period or after you go to bed. The night period is definable by
the PC application or by the OLED keypad and it is defined by
default as 0:00 to 06:00.
You can also arm the system in Night mode, at any time if
you press the key right after entering the code. A more
discreet beep will sound and the exit timer will appear on the
OLED keypad until the alarm is armed.
If someone arrives home and the alarm is armed in Night
mode it will start counting the entry time during which the
user has to enter his code.
The user may rearm the alarm immediately by pressing the
key right after entering the code. If the automatic arming is
enabled then the alarm will rearm 10 minutes later.

SE
CURITY
In the morning the alarm remains armed in night mode even
after the night period as finished until the first interior
detection. After that the system automatically disarms.
artial mode
The partial mode as the name suggests allows partial
protection of the house i.e. only certain areas of the house
will be protected when the alarm is activated (e.g. Garage).
To arm in partial mode enter a valid user code then press
key
within 2 seconds
. A more discreet beep will sound
until the alarm arms.
Restore Water supply
The water cut relay is activated when water leakage is
detected for more than 30 seconds. This time is necessary to
prevent the water supply to be cut when for example
cleaning the floor.
To restore water supply you must either restore it with a
phone call (see Command through telephone) or enter the
Master Code.
Restore Gas supply
The gas cut relay is activated automatically when a gas
leakage is detected.
VERY IM ORTANT: make sure you request assistance from
specialized personnel to solve this problem. Gas leakage has
a high risk of explosion.
Once a specialized technician has solved the leakage problem
restore the gas supply by making a phone call (see Command
through telephone) or enter the Master Code.
This manual suits for next models
3
Table of contents