Onwa KEC-30 User manual

˵Ã÷Êé
˵Ã÷Êé
R
KEC-30
KEC-30
ELECTRONIC FLUXGATE COMPASS
OPERATOR`S MANUAL


FEATURES 2
SYSTEM CONFIGURATION 3
1 OPERATION 4
1.1 Controls 4
1.2 Turning the power on/off 5
1.3 Panel Illumination, Display contrast 5
1.4 Display 6
1.5 Function setting 9
1.5.2 Auto Heading Adjust 10
1.5.3 Manual Heading Adjust 12
1.5.4 Heading Alignment Setting 12
1.5.5 Language Setting 13
1.5.6 Time Setting 13
1.5.7 Output Setting 14
FOREWORD 1
2 INSTALLATION & MOUNTING CONSIDERATIONS 16
2.1 Fluxgate Compass Unit 16
2.1.1 16Outdoor installation
2.1.2 Desktop mounting 17
2.1.3 Bulkhead mounting 18
2.2 Display Unit 19
2.2.1 Desktop, Overhead mounting 20
2.3 Wiring 22
2.2.2 Flush mount 21
1.5.8 Factory Default Setting 15
1.5.1 Heading Display 9
CONTENTS

3 MAINTENANCE, TROUBLESHOOTING 23
3.1 Preventive maintenance 23
3.2 Troubleshooting 24
INTERCONNECTION DIAGRAM 27
DISPLAY UNIT SIZE 29
FLUXGATE SENSOR SIZE 30
CONNECTING CABLES 28
C-BRACKET SIZE CHART 31
THE SPECIFICATIONS OF KEC-30 25
CONTENTS

SAFETY INSTRUCTIONS
WARNING
Do not openthe equipment.
Only qualified personnelshould work
inside the equipment.
Do not disassembleor modify the
equipment.
Fire,electrical shock orserious injury
can result.
Immediately turn offthe power at
the switchboard ifthe equipment is
emitting smoke orfire.
Continued use ofthe equipment can
cause fire orelectrical shock.Contact
a ONWA agent for service.
Use the properfuse.
Use of awrong fuse candamage the
equipment or causefire.
Be sure thepower supply is
compatible with theequipment.
Incorrect power supplymay cause the
equipment to overheat.
The useable temperaturerange for
the antenna unitis -25 to 70 ;
-15 to 55 for the displayunit.
Use of theequipment out ofthose
ranges may damagethe equipment.
Safety Instructions for the Operator
Safety Instructions for the Installer
WARNING
Do not openthe cover unlesstotally
familiar with electricalcircuits and
service manual.
Improper handling canresult in
electrical shock.
Turn off the power at the switchboard
before beginning the installation.
Fire or electricalshock can result if the
power is lefton.
Be sure thatthe power supplyis
compatible with thevoltage rating
of the equipment.
Connection of anincorrect power
supply can causefire or equipment
damage.
Use the properfuse.
Use of awrong fuse candamage the
equipment or causefire.
NOTICE
Observe the following compass safe
distances to prevent interference to
a magnetic compass:
0.4 m 0.3 m
1.2 m 1.2 m
Display unit
Standard
Compass
Steering
Compass
Processor

FOREWORD
Thanks you for purchasing the ONWA KEC-30
Your equipment is designed and constructed to meet the rigorous demands of
the marine environment. However, no machine can perform its intended
function unless properly installed and maintained.
Please carefully read and follow the operation, installation and maintenance
procedures set forth in this manual.
We would appreciate feedback from you.
Thank you for considering and purchasing ONWA.
Electronic Fluxgate Compass.
1

The KEC-30 is a designed with ONWA`s advanced
LCD high definition display technology. This compass a wide range
of applications for any type of ships
The main features are
Perfect for use as heading sensor for Radar/ARPA, AIS, ECDIS,
scanning sonar
There are no mechanical parts such as gimbals or rotating motor, thus the
compass is free from routine maintenance
Chinese and English menu display
Electronic Fluxgate Compass
It uses a fluxgate magnetic sensor in conjunction with a microprocessor to
display accurate heading.
The KEC-30 can correct magnetic deviation manually or automatically.
provides
at sea and vehicles on land.
2
FEATURES

SYSTEM CONFIGURATIONSYSTEM CONFIGURATION
The KEC-30 consists of a Display unit and a Fluxgate Sensor unit.
Fluxgate Sensor unit
KFG-25
Display unit
KEC-30
External GPS data input
The heading signal output
DC10.5V~40V
KEC-30 ELECTRONIC COMPASS
MENU
PWR
KEC-30
ENT
ESC DIM
DISP
3

1. OPERATION1. OPERATION
MENU: Open Menu
Omnipad: Select the menu item
ENT: To identify or modify
the selection
KEC-30 ELECTRONIC COMPASS
MENU
PWR
KEC-30
ENT
ESC DIM
DISP DIM: Adjust LCD brightness
and contrast
DISP: Select the display
mode
PWR: To switch on/off the
unit
4
ESC: Exit the menu item.
1.1 Controls

1.3 Panel Illumination, Display contrast
1. Press the [DIM] key.
Dialog box for adjustment of panel illumination, display contrast
2. Press or to adjust LCD display brightness and panel illumination.
3. Press or to adjust
4. Press the [ESC] key
LCD display contrast.
to confirm and exit.
1.2 Turning the power on/off
Turning the Power On, press [PWR] once to switch on the unit with a
"beep" sound.
Turning the Power Off, Press and hold [PWR] key until the unit turn off.
5
BRILL (18)
CONTRAST
2
32
(063)
EXIT: [ESC]
R
Electronic Fluxgate Compass
KEC-30
Ver : 1.0
TURNING OFF
IN 3 SEC

1.4 Display
There are three display screen, press the [DISP] key to cycle.
6
210 240
W
300
330
N
30
N
60
E
120
150
S
HDT:
224
SOG:
COG:
N 22 45.108 E 115 47.203
211
04Kt
224
220 230 240 250 260
COG:
kt
HDT:
200 210
SOG:
04
3D 2011-01-31 03:36
211
HDT:
COG:SOG:
kt
N 22 45.108 E 115 47.203
224
3D 2011-01-31 03:36
04211

3D 2011-01-31 03:36
of display
The shows , date, time
and position-fixing status.
Modes
Navigation data display
navigation data display magnetic heading, COG, SOG
7
Note: beside the a NMEA0183 input is needed for displaying
all other navigation data.
magnetic heading
Date
Course Over Ground
Position data
Speed Over Ground
Location Status Time
Boat's heading
HDT:
COG:SOG:
kt
N 22 45.108 E 115 47.203
224
No external data input display
When not connected to an external GPS unit. Navigation data will not be displayed
to show only the current .magnetic heading
HDG:
COG:SOG:
kt
224
No navigation data display screen
04211

Compass display
The compass display shows heading by compass direction. The compass rotates
with heading.
Steering display
The steering display shows heading in digital and analog form. SOG and COG
are also indicated.
Azimuth Scale
Heading tag
8
224
220 230 240 250 260
COG:
kt
HDT:
200 210
SOG:
210 240
W
300
330
N
30
N
60
E
120
150
S
HDT:
224
SOG:
COG:
N 22 45.108 E 115 47.203
04
3D 2011-01-31 03:36
211
211
04kt

1.5 Function setting
Menu function provides automatic and manual orientation rectification azimuth
Angle, language, fixed supplement, time setting, the setting, etc.
1.5.1 Heading Display
,
orientation.
factory default
In the menu select "HEADING DISPLAY" and press [ENT] key.
The following window appears:
Choose when TURE, If external input NMEA data contain Lon/Lat information
KEC30 would use it to calculate "Magnetic Variation" to show HDT direction
otherwise show HDG direction.
Choose when MAGNETIC whether Input any voyage data Are show HDG
9
MENU
AUTO HEADING ADJUST
MANUAL HEADING ADJUST
HEADING ALIGNMENT SETTING
LANGUAGE SETTING
TIME SETTING
OUTPUT SETTING
FACTORY DEFAULT SETTING
HEADING DISPLAY TRUE
MENU
AUTO HEADING ADJUST
MANUAL HEADING ADJUST
HEADING ALIGNMENT SETTING
LANGUAGE SETTING
TIME SETTING
OUTPUT SETTING
FACTORY DEFAULT SETTING
HEADING DISPLAY MAGNETIC
TRUE

AUTO HEADING ADJUST
Auto heading adjusting !
Please keep constant speed less
than 2 minutes for each turn
Cancel [ESC] OK [ENT]
1.5.2 Auto Heading Adjust
In the menu select and press [ENT] key.
The following window appears:
The compass has been calibrated during manufacture. This calibration will be
satisfactory for almost all installations. If you have a steel vessel, or some
other factor which causes the compass to perform poorly, the calibration
procedure will adjust compass characteristics to compensate.
The calibration should only be done if the compass is known to be inaccurate.
If the KEC-30 display as constant offset (e.g. the compass reads 3 degrees
high on all bearings), simply rotate the Fluxgate Sensor case to align
bearings with the ships compass. It is not necessary to re-calibrate the
compass as described below.
If the KEC-30 has inconsistent variation on different headings, the following
calibration procedure can be carried out. This procedure should only be done
in calm waters with adequate sea room.
"AUTO HEADING ADJUST"
10

If correction fails the following message appear:
The message goes away after 6 seconds.
In case of correction fails repeat the above steps until the correction is successful.
Press [ENT] to confirm make corrections, return to the main screen message
will appear to make corrections, while the main screen of data per second
update.
210 240
W
300
330
N
30
N
60
E
120
150
S
HDG:
224
SOG:
COG:
Auto heading adjustment failed!
11
210 240
W
300
330
N
30
N
60
E
120
150
S
HDG:
224
SOG:
COG:
Auto heading adjusting....
04kt
211
210 240
W
300
330
N
30
N
60
E
120
150
S
HDG:
224
SOG:
COG:
Auto heading adjustment success!
04kt
211
04kt
211
Steer the vessel in clockwise direction with constant speed less than 2
minutes per each circle until the following correction success message appear.
If correction success the following message appear:

1.5.3 Manual Heading Adjust
Manual is a supplement to the type of single orientation
parabola 10 degrees. But this method could
Compensation
only be done by
qualified personnel.
to adjacent
1. In the menu select and press [ENT] key.
The following window appears:
"MANUAL HEADING ADJUST"
2. Use up, down key to hen use
left, right key to increase or decrease the
select the direction angle need to be modified, t
number of angle in Degree. The
highest may adjust 10 .
3. Press [ENT] key to save.
Note:
shows each azimuth are unlikely to maintain consistent.
Anyway ship's magnetic compass and electronic fluxgate compass
Cancel [ESC] OK [ENT]
MANUAL HEADING ADJUST
120 +00
150 +00
180 +00
210 +00
240 +00
270 +00
300 +00
330 +00
0+00
30 +00
60 +00
90 +00
1.5.4 Heading Alignment Setting
Adjustment of heading might be needed during the installation. Usually a fixed
error in all direction would exist. It is due to the mechanical error when fixing
the fluxgate sensor KFG-25. The function "Degree Amend" is used to correct
this error.
select "HEADING ALIGNMENT SETTING"1. In the menu and press
[ENT] key. The following window appears:
2.
3. Press or to
4. Press [ENT] key
Move the cursor to the corresponding field.
change the direction and angle in degree.
The highest may adjust 99 .
to save or press [ESC] to quit without save.
Cancel [ESC] OK [ENT]
Heading alignment setting
224 0 (224 )0
+
12

2.
3. Press [ENT] key t
Move the cursor to "English" or "Chinese"
o confirm save or press [ESC] to quit without save.
13
TIME SETTING
Cancel [ESC] OK [ENT]
+00:00
1.5.6 Time Setting
When the equipment connect GPS data, can display the time on the
In the menu
1. In the menu option to and press [ENT] key.
The following window appears:
external
Navigation data display mode.
"TIME SETTING" to enter the corresponding time difference.
select "TIME SETTING"
2. Press or key to move the cursor
3. Press or key to modify the
4. Press [ENT] key .
Note: If the change successful. The UTC in the top right corner will turn
into LTC.
to the field need to be modified.
time difference.
to save or press [ESC] to quit without save
Cancel [ESC] OK [ENT]
LANGUAGE SETTING
ENGLISH
1.5.5 Language Setting
Suitable for different users. Can choose Chinese / English display menus.
1. In the menu options and press [ENT] key.
The following window appears:
, select "LANGUAGE SETTING"

14
1.5.7 OUTPUT SETTING
OUTPUT : 1 X NMEA0183: HDG, HDT, HDM
a) Output data includes the following three
HDT: True heading
HDM: Magnetic heading
HDG: Magnetic heading & Magnetic variation value
Cancel [ESC] OK [ENT]
OUTPUT SETTING
HDT
4800 9600 19200
38400
25ms
Type
Baud rate
Interval
HDM HDG
100ms 200ms
1000ms
b)
Three types of outputs can select singly or output together ,the optional
interval is 25ms, 100ms, 1,000ms(1s), The standard interval is 200ms,
three can output together .
c) 48
The optional speed of output, the standard is 00, the optional one is
9600, 19200 and 38400
1000
4800
9600
19200
38400
25
100
200
1000
25
100
200
1000
100
200
1000
25
25
100
200
Relation baud rate and output interval
Baud rate
Output interval
Available sentences
No output
Up to two sentences can
be output.
Up to three sentences can
be output
HDT or HDM
Up to three sentences can
be output
Up to two sentences can
be output.
Up to three sentences can
be output.
Note: When an error message occurs, the above sentences
may be changed.

1.5.8 Default Settings
1. In the menu options and press
[ENT] key. The following window appears:
Factory
For any reason need to reset all settings to factory default setting you can do
as following instruction.
to select "FACTORY DEFAULT SETTING"
2. Press the [ENT] key to load factory default setting or press [ESC] to quit
without any change.
Note: When you select to load factory default setting all saved settings
would be cleared. This action can not reversible.
FACTORY DEFAULT
Restore to
factory default setting !
Cancel [ESC] OK [ENT]
15
Remark:
If no external navigational data input or magnetic variation data is not included
in the external input data then:
1) HDT outputs magnetic bearing instead of true heading data.
2) The magnetic variation data in HDM would be 0 .
""
"" ""
Table of contents
Other Onwa Marine Equipment manuals
Popular Marine Equipment manuals by other brands

Magnadyne
Magnadyne M6100CD Installation and operation manual

Seastar Solutions
Seastar Solutions HF6010 Supplement Instructions

Seiwa
Seiwa SWx 900 Installation guides

Humminbird
Humminbird Trolling Motor 360 Imaging installation guide

Satel
Satel ACSP SPP-401 quick start guide

KVH Industries
KVH Industries TracPhone V7-HTS installation guide

Selden
Selden Furlex 200 TD Assembly manual

Harken
Harken 1618 Midrange Installation sheet

Raytheon Anschütz
Raytheon Anschütz NautoPilot 5000 Series Operator's manual

MEDC
MEDC HORN DB3 Technical manual

AB Marine
AB Marine Gori installation instructions

COBHAM
COBHAM SAILOR FleetBroadband Series Training manual