Onyx ONYX-122 User manual

Slim Medical Panel PC ONYX-122
ONYX-122
11.6” Intel®CoreTM 2 Duo
Processor
High Brightness
Slim Medical Panel PC
ONYX-122 Manual 1st Edition
Nov. 2010

Slim Medical Panel PC ONYX-122
Copyright Notice
This document is copyrighted, 2010. All rights are reserved. The
original manufacturer reserves the right to make improvements to
the products described in this manual at any time without notice.
No part of this manual may be reproduced, copied, translated, or
transmitted in any form or by any means without the prior written
permission of the original manufacturer. Information provided in
this manual is intended to be accurate and reliable. However, the
original manufacturer assumes no responsibility for its use, nor
for any infringements upon the rights of third parties, which may
result from its use.
The material in this document is for product information only and
is subject to change without notice. While reasonable efforts have
been made in the preparation of this document to assure its
accuracy, ONYX Healthcare Inc., assumes no liabilities resulting
from errors or omissions in this document, or from the use of the
information contained herein.
ONYX Healthcare Inc. reserves the right to make changes in the
product design without notice to its users.

Slim Medical Panel PC ONYX-122
Acknowledgments
Intel®Core™ Duo are registered trademarks of Intel®
Corporation.
IBM, PC/AT, PS/2 are trademarks of International Business
Machines Corporation.
Microsoft®Windows is a registered trademark of Microsoft®
Corporation.
RTL is a trademark of Realtek Semi-Conductor Co., Ltd.
C&T is a trademark of Chips and Technologies, Inc.
UMC is a trademark of United Microelectronics Corporation.
ITE is a trademark of Integrated Technology Express, Inc.
All other product names or trademarks are properties of
their respective owners.

Slim Medical Panel PC ONYX-122
Packing List
Before you begin installing your Bedside Terminal, please make
sure that the following items have been shipped:
ONYX-122Medical Station
HDD screws
Utility CD-ROM (Please insert the ONYX-122 CD-ROM into
external CD-ROM drive.) which Contains User’s Manual (in
PDF format), Drivers and Utilities
If any of these items are missing or damaged, you should contact
your distributor or sales representative immediately.
Headquarters
Onyx Healthcare Inc.
2F, No.135, Lane 235, Pao-Chiao Rd.,
Hsin-Tien City, Taipei 231, Taiwan, R.O.C.
TEL: +886-2-8919-2188
FAX: +886-2-8919-1699
http://www.onyx-healthcare.com

Slim Medical Panel PC ONYX-122
Worldwide Offices:
Onyx Healthcare, USA Inc.
2663 Saturn street, Brea, CA92821, USA
Tel : +1-714-996-1800
Fax: +1-714-996-1811
Onyx Healthcare EUROPE B.V.
Ekkersrijt 4002, 5692 DASon, The Netherlands
Tel : +31-(0)499-462020
Fax: +31-(0)499-462010
Onyx Healthcare Technology GmbH
An der Trift65d
63303 Dreieich , Germany
TEL: +49-(0)61033-7479-00
Fax : +49-(0)61033-7479-49
Onyx Healthcare (SU ZHOU) INC.
Room 12, 2F, Building B, No.5 Xing Han Street, Suzhou Industrial
Park, Jiang Su Province, China
Tel: +86-512-67625700
Fax: +86-512-67617337
Email: [email protected]

Slim Medical Panel PC ONYX-122
Onyx Healthcare Singapore PTE LTD
57 Genting Lane, #07-00, Singapore 349564
Tel: +65-67498749
Fax +65-67461595
Email: [email protected]

Slim Medical Panel PC ONYX-122
Safety & Warranty
1. Read these safety instructions carefully.
2. Keep this user's manual for later reference.
3. Disconnect this equipment from any AC outlet before cleaning. Do not
use liquid or spray detergents for cleaning. Use a damp cloth.
4. For pluggable equipment, the power outlet must be installed near the
equipment and must be easily accessible.
5. Keep this equipment away from humidity.
6. Put this equipment on a reliable surface during installation. Dropping it
or letting it fall could cause damage.
7. The openings on the enclosure are for air convection. Protect the
equipment from overheating. DO NOT COVER THE OPENINGS.
8. Make sure the voltage of the power source is correct before
connecting the equipment to the power outlet.
9. Position the power cord so that people cannot step on it. Do not place
anything over the power cord.
10. All cautions and warnings on the equipment should be noted.
11. If the equipment is not used for a long time, disconnect it from the
power source to avoid damage by transient over-voltage.
12. Never pour any liquid into an opening. This could cause fire or
electrical shock.
13. Never open the equipment. For safety reasons, only qualified service
personnel should open the equipment.

Slim Medical Panel PC ONYX-122
14. If any of the following situations arises, get the equipment
checked by service personnel:
a. The power cord or plug is damaged.
b. Liquid has penetrated into the equipment.
c. The equipment has been exposed to moisture.
d. The equipment does not work well, or you cannot get it to
work according to the user’s manual.
e. The equipment has been dropped and damaged.
f. The equipment has obvious signs of breakage.
15. DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED
ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS
BELOW -20° C (-4°F) OR ABOVE 60° C (140° F). IT MAY DAMAGE
THE EQUIPMENT.
16. External equipment intended for connection to signal
input/output or other connectors, shall comply with relevant UL /
IEC standard (e.g. UL 1950 for IT equipment and UL 60601-1 /
IEC 60601 series for systems – shall comply with the standard
IEC 60601-1-1, Safety requirements for medical electrical systems.
Equipment not complying with UL 60601-1 shall be kept outside
environment, as defined in the standard.
Caution:
It may cause the danger of explosion if battery is incorrectly
replaced. Replace only with same or equivalent type recommended
by the manufacturer.

Slim Medical Panel PC ONYX-122
Classification
1. Degree of production against electric shock: not classified
2. Degree of protection against the ingress of water: IPX1
3. Equipment not suitable for use in the presence of a flammable
anesthetic mixture with air or with oxygen or nitrous oxide.
4. Mode of operation: Continuous
5. Type of protection against electric shock: Class I equipment

Slim Medical Panel PC ONYX-122
FCC
This device complies with Part 15 FCC
Rules. Operation is subject to the
following two conditions: (1) this device
may not cause harmful interference, and (2)
this device must accept any interference
received including interference that may
cause undesired operation.

Slim Medical Panel PC ONYX-122
UL Module Description
Onyx-122 AC modules are developed to suitable
for the Classification Mark requirement

Slim Medical Panel PC ONYX-122
Safety Symbol Description
The following safety symbols are the further explanations for your
reference.
Medical equipment with respect to electric
shock, fire and mechanical hazards only in
accordance with UL 60601-1, and
CAN/CSA C22.2 NO. 601.1
Attention, consult ACCOMPANYING
DOCUMENTS.
Ground wire
Protective Ground wire.
Medical equipment with respect to electric
shock, fire and mechanical hazards only in
accordance with UL 60601-1, and
CAN/CSA C22.2 NO. 601.1

Slim Medical Panel PC ONYX-122
Below Table for China RoHS Requirements
產品中有毒有害物質或元素名稱及含量
Onyx Panel PC/ Workstation
有毒有害物質或元素
部件名稱 鉛
(Pb)
汞
(Hg)
鎘
(Cd)
六價鉻
(Cr(VI))
多溴聯苯
(PBB)
多溴二苯醚
(PBDE)
印刷電路板
及其電子元件 × ○○○○○
外部信號
連接器及線材 × ○○○○○
外殼 × ○○○○○
中央處理器
與記憶體 × ○○○○○
硬碟 × ○○○○○
液晶模組 × ○○○○○
光碟機 × ○○○○○
觸控模組 × ○○○○○
電源 × ○○○○○
O:表示該有毒有害物質在該部件所有均質材料中的含量均在
SJ/T 11363-2006 標準規定的限量要求以下。
X:表示該有毒有害物質至少在該部件的某一均質材料中的含量超出
SJ/T 11363-2006 標準規定的限量要求。
備註:
一、此產品所標示之環保使用期限,系指在一般正常使用狀況下。
二、上述部件物質中央處理器、記憶體、硬碟、光碟機、觸控模組為選購品。

Slim Medical Panel PC ONYX-122
Contents
Chapter 1 General Information
1.1 Introduction ......................................................................1-2
1.2 Feature.............................................................................1-3
1.3 Specification.....................................................................1-4
1.4 Dimension ........................................................................1-8
Chapter 2 Hardware Installation
2.1 Safety Precautions...........................................................2-2
2.2 A Quick Tour of the ONYX-122......................................2-3
2.3 Removing the rear maintenance cover............................2-4
2.4 2.5”Hard Disk Drive(HDD) Installation.............................2-4
Chapter 3 Award BIOS Setup
3.1 System Test and Initialization..........................................3-2
3.2 Award BIOS Setup...........................................................3-3
Chapter 4 Driver Installation
4.1 Installation........................................................................4-3
Appendix A Programming the Watchdog timer
A.1 Programming..................................................................A-2
A.2 ITE8712 Watchdog timer initial Program ......................A-5
Appendix B I/O Information
B.1 I/O Address Map.............................................................B-2

Slim Medical Panel PC ONYX-122
B.2 Memory Address Map.....................................................B-2
B.3 IRQ Mapping Chart .......................................................B-3
B.4 DMA Channel Assignments............................................ B-5
Appendix C Miscellanea
C.1 General Cleaning Tips....................................................C-2
C.2 Cleaning Tools................................................................C-3
C.3 Scrap Computer Recycling ...........................................C-5

Slim Medical Panel PC ONYX-122
Chapter 1 General Information 1-1
General
Information
Chapter
1

Slim Medical Panel PC ONYX-122
Chapter 1 General Information 1-2
1.1 Introduction
The ONYX-122 is a Slim Medical Panel PC with Intel®CoreTM 2
Duo ULV processor-based computer that is designed to serve as a
point of care station. It is a PC-based system with 11.6” WXGA
color TFT LCD display, Zero Noise solution; integrated multimedia
functions make them the perfect platforms to build comprehensive
lifestyle computing applications.
The ONYX-122 includes all the features of a powerful computer into
a slim and attractive chassis. The ONYX-122 has 200 nits TFT
displays with Full HD 1366 x 768 resolution and integrate with high
brightness LCD. It supports 2.5” Hard Disk Drive storage function
and one Mini-PCI for WLAN expansion. Moreover, they feature
flexible I/O ports, such as four USB2.0, one RS-232 and one
optional isolated COM, one Gigabit Ethernet, one PS/2 keyboard/
mouse, and two speakers.
Convenient operation, Silent, compact, mobility and highly
integrated multimedia system let you to focus on healthcare utility,
interactive information displays, automation control systems,
general desktop usage, multimedia recreation, and other medical
requirements.

Slim Medical Panel PC ONYX-122
Chapter 1 General Information 1-3
1.2 Feature
11.6” WXGA colorTFT LCD
Easy To Use, Compact, Simple Design
Fanless, Zero Noise
High Contrast Ratio, Wide Viewing Angle For Medical Imaging
Intel® Core™ 2 Duo ULV Processor
Resistive Touchscreen (Optional)
802.11a/b/g/n Wireless Antenna (Optional)
USB & COM Isolation (Optional)

Slim Medical Panel PC ONYX-122
Chapter 1 General Information 1-4
1.3 Specification
Hardware Specifications
Display ONYX-122: 11.6” WXGA color TFT LCD
System
Memory 200-pin DDRII SODIMM x 1, Max. 2GB(optional)
CPU Board Intel® CoreTM 2 Duo Processor 1.6GHz
Drive Bay 2.5” Hard Disk Drive (optional)
Expansion Mini-PCI x 1
Button Brightness: “+” / ”-“; Sound: “+” / ”-“; Power SW
I/O RS-232 x 1, COM isolation x 2 (optional)
USB 2.0 x 4, USB isolation x 1 (optional)
10/100/1000 Base-TX x 1
PS/2 keyboard/ mouse x 1
Audio Line out
LCD Specifications
Model Name ONYX-122
Display Type 11.6” WXGAcolor TFT LCD
Max. Resolution 1366 x 768
Max. Colors 262K colors
Dot Size (mm) 0.1875 x 0.1875
Luminance (cd/m2) 200 (TYP)
90°(H)
Viewing Angle
50°(V)

Slim Medical Panel PC ONYX-122
Chapter 1 General Information 1-5
Contrast Ratio 500 : 1
Brightness Control Yes
Back Light MTBF 15,000 Hrs
Note: All ONYX's LCD products are manufactured with High precision
technology. However, there are a small number of defective pixels in all
LCD panels that are not able to change color. This is a normal occurrence
for all LCD displays from all manufacturers and should not be noticeable or
objectionable under normal operation. ONYX LCD panels are qualified for
industry standard conditions in the following: total 7 dead pixels on a
screen or if there are 3 within 1 inch square area of each other on the
display.
Mechanical Specifications
Architecture Plastic casing and metal construction
Front Bezel IP65 Plastic bezel with resistive touch screen
Color Pearl White
Mounting / Holder Panel mount, VESA 75mm
Construction 3mm ABS + PC TYPE Plastic housing
Dimension
(W x H x D)
11.8”x 8.2”x2.2” (300*205*55.2mm)
Carton Dimension 19.1” x 10.3” x 15.7” (486*262*400mm)
Net Weight 5.94lb (2.7kg)
Gross Weight 10.12 lb (4.6 kg)
Packing Filler PE
Table of contents
Other Onyx Touch Panel manuals
Popular Touch Panel manuals by other brands

Avalue Technology
Avalue Technology OFP-21W38 Quick reference guide

AMX
AMX Modero Viewpoint MVP-5200i Operation/reference guide

Kingdy
Kingdy IP Series user manual

Elo TouchSystems
Elo TouchSystems SRK-MPPC Series user manual

Avalue Technology
Avalue Technology SID-21WR2 Quick reference guide

Advantech
Advantech IPPC-4001 Series user manual