ETHERNET CABLE
CONNECTIONS
Connect a network cable to the camera
using the RJ45 input and connect the
other end of the cable to your network
switch or recorder.
Check the status of the
network connection
by looking at the link
indicator and activ-
ity indicator LEDs. If
the LEDs are not lit check your network
connection. The green link LED indicates
a network connection and the orange
activity LED flashes to indicate network
activity.
POWER
This camera is compatible with 12vDC,
24vAC and Power over Ethernet (PoE).
Connect power to the camera using the
terminal connector blocks. If you are con-
necting 12vDC power, verify the polarity
of the power connection.
CONTENTS
INSTALLATION
1. Apply template sticker to desired
camera location
2. Drill anchor holes using included
mounting template
3. Remove mounting template
4. Insert anchors
5. Mount camera
6. Adjust camera view
7. Secure Lid / dome
NOTE: If the camera will be exposed
to inclement weather, OpenEye
recommends sealing around the
camera base, or connection to
accessory and accessory connection
to mounting surface with waterproof
caulking.
ASSIGNING AN
IP ADDRESS
OpenEye IP cameras are set to DHCP
by default. If a DHCP server is not
detected after 4 minutes, the camera
will default to IP address 192.168.51.2.
If you are not using a DHCP server,
NCM will allow you to batch configure a
static IP address.
The IP address for the camera network
on your Apex recorder is 192.168.51.1.
Selecting multiple cameras and entering
IP address 192.168.51.2 will set an
IP address on all selected cameras,
starting at 192.168.51.2 and increase
per camera.
1. Open Network Camera Manager
2. Select applicable camera(s)
3. Input starting IP address, Subnet
Mask, Gateway, DNS
4. Apply changes
5. Wait 60 seconds before refreshing
NCM
OE-C7624 Dome
Camera
Camera
Maximum Resolution 4MP
Frame Rate at
Maximum Resolution
30 FPS @ 4MP - H.264
/ H.265
Total Streams Up to 3 simultaneous
streams
ONVIF ONVIF Profile S / G / T
Compliant
Day/Night True Day / Night
Wide Dynamic Range True WDR
Environmental and Power
Power
Consumption 13.68W Max
Input Voltage 12vDC / 24vAC / PoE
PoE Class 0
IP Rating IP66
Operating
Temperature -40 ~ 131 °F (-40 ~ 55 °C)
PRODUCT FEATURES
Quick Start
Guide
2-Pin Terminal
Power Block
Self-Tapping
Screws &
Plastic Anchors
Security Torx
Tool
4-Pin Terminal
Alarm Block
NOTE: To change this IP address please
refer to your Apex recorder manual.
NOTE: NCM requires entry in all fields.
NOTE: OpenEye IP cameras ship
without a default password.
DEFAULT USERNAME
AND PASSWORD
The admin user password can be
set using the following methods:
1. OpenEye recorders running Apex
2.1 or newer will automatically set a
new unique password if:
• Connected to an M-Series
recorder with a built in PoE
switch.
NOTE: The NCM software manual can be
found at https://www.openeye.net/
ncm-manual
CONNECTING TO THE
IP CAMERA
To access the camera setup menu, you
need to open Network Camera Manager
(NCM) utility. NCM is pre-installed on
all OpenEye Recorders, and is also
available for download on the OpenEye
website for installation on your personal
computer or laptop.
1. Open Network Camera
Manager.
2. Locate your camera on the
Network Camera Manager list.
3. To open the web browser, select
the camera and click Load.
• Connected to a network
switch through the
camera network port
and selected then added in
setup, if a new password has
not already been set.
2. Connect to the camera directly
through a Web Browser and follow
the onscreen prompts.
3. Use the Network Camera Manager
(NCM) Utility.
Username: admin
CAUTION: Risk of explosion of battery is replaced
by an incorrect type. Dispose of used batteries ac-
cording to the instructions.
The product is intended to be supplied by a UL
Listed Power supply suitable for use at (Tma =
55 degree C) whose output meets SELV/ES1
and LPS/PS2, and is rated (1) 12Vdc, 1.2A min.,
(2) 24Vac, 50/60Hz or 50-60Hz, 0.55A min., (3)
48Vdc, 0.255A min.