Optogate device. The Optogates were designed for professional applications
and to be used by experienced sound engineers and technicians.
The Optogates work with 48V phantom power. Just switch on the 48V on the
console and the Optogate is active. The phantom power passes through the
Optogate and to the microphone. If you use dynamic mics you can "remote
control" the unit with the phantom power switch. The microphone is switched
on when the phantom power is switched off. Before turning on or off the
phantom power please mute the channel in order to prevent switching noise.
The PB-05 M and D models have a small bypass button on the top of the
unit which when pressed will pass audio uninterrupted. It is like a panic
button for the Artist. Make sure you switch it back when mute function is
desired. Or the Monitor engineer with out having to go on stage can switch
the phantom power off to that channel and then on again which will restore
the units function. The PB-05E however can not power condenser mics, only
dynamic mics and do not have a switch but they can be bypassed by turning
off phantom power to that channel.
You have already found 3 LED devices on one side, depending on what model
you choose. The middle device is a red status LED. It indicates if somebody is
in front of the unit and the microphone is switched on. The outer LED’s are
the infrared transmitter and the receiver. The transmitter will send 16 pulses
per second if the phantom power is switched on. The Optogate will switch the
mic on if there is any signal reflected from a surface back to the receiver.
The receiver uses a small code in order to reduce false triggering from
random infrared signals on the stage like par cans, moving lights etc.
The distance from the mic to the performer in which the unit opens and
closes is adjustable with the help of a 12-turn spindle potentiometer inside.
On all units the distance will increase by turning the pot to the Right for a
maximum distance of about 4 feet and will decrease the distance by turning
the pot to the Left for a minimum of 2 inches. Please be aware that some
dark materials are not able to reflect infrared signals back very well, which in
turn might decrease the distance. Please experiment with the potentiometer
to fine-tune the distance together with the performer before using live. It
also would be helpful to have your show lighting active while adjusting. The
width of the sensor is about 15 degrees wide from the unit. The mic will be
switched off if the artist moves out of this angle.

When you turn the pot to the left eventually you will hear a light click of a
spring. You cannot overturn the pot. You are now at the shortest distance
range. When you start to turn the pot clockwise, you will find that the
distance range will change very slowly in the first few turns. After a few
turns, the distance will change more rapidly until you reach the maximum
range. If you turn the potentiometer clockwise (right) out of the
useable area, the mic will be switched on completely. If this
happens, just turn the pot slightly to the left until the Optogate
works again.
We suggest that the engineer work with each performer to explain the
operation of the unit and then set the range of the Optogate to fit his or her
mic technique and stage set-up. As a rule the closer the performer is to the
mic, the better the results will be due to eliminating the concert lighting
variables.
The Optogates PB-05M and PB-05D, work well with dynamic mics and
condenser mics up to 10 mA current draw. You may find out that the switch-
off time of the indicator led can be a bit different from the real audio switch
time depending of the mic type. A small pwm routine in the Optogate is
responsible for it in order to prevent switching noise. The spindle pot will
adjust to a wide range of mics. The distance range of the Optogate can
change a bit when the ambient light changes. Like every other infrared
device on the market the Optogate units do not work correctly if direct
sunlight or other very high power infrared signals hits the sensor. That is in
the "nature" of the infrared technology due to the random high power
infrared spectrum in the sunlight. You can try it at home with any IR remote
control. No infrared sensor of CD-players, TV’s etc. will work in direct
sunlight. If direct sunlight hits the sensor of the Optogate the distance will
decrease until the mic will be switched off. The unit will work again if
somebody moves between the sun and the sensor. Normally you can use the
Optogates on almost every open-air stage without any problems. It is always
a good idea to check the range of your Optogates when changing venues,
especially outdoors with direct sunlight.
Remember the PB-05 E is the same as the Pro except it is designed to only
work with Dynamic Microphones and does not have a bypass button.
Bypassing is accomplished by turning OFF the phantom power to that mic.

PB-07
On this model the sensor is on the flat side.
You can attach the included plastic clip and the 4 mm screw on your PB-07.
You can use any 4 mm screw up to 5 mm inside of the PB-07 case. Do not
use longer screws as to prevent touching the connectors and damaging
them. Clip the PB-07 to the mic stand and the clip will disappear behind the
stand. The PB-07 can be connected directly to a gooseneck
microphone as well. The PB-07 is ideal for lead and back-up vocals,
acoustical instruments, talk-back mics, lecterns and podiums.
If you use a console with less than 48V phantom power or if your condenser
mic needs more than 10 mA then just send the Optogate to us and we will
modify it to work with your equipment, without any cost.
The Optogate devices were developed for use with professional equipment
and should be used by only professional system engineers and operators.
Please be aware that we are not responsible for any hazards or damages due
to the using of the Optogate devices. The Optogate devices are registered
under the number DE54933725 WEEE as B2B
devices. We also declare that they conform to the CE and ROHS for the
European market.
NOTE:
Removal of face plates and/or tampering with electronics voids warranty.
If you have further questions please don’t hesitate to contact us:
Phone: 805.766.0069
Email:
info@optogatesolutions.com
This manual suits for next models
1
Table of contents