Orima AS1 User manual

www.orima.fi © Copyright Orima-Tuote Oy. Kankaantie 6, FI-16300 Orimattila
Unauthorised use and copying is forbidden.
ISO 9001
BUREAU VERITAS
Certification
No FIHSK10155078A
WALL LADDER
ASSEMBLY AND DIMENSIONING
LADDER PLACEMENT
The best placement for the ladder is the gable where snow loads cannot damage the ladder and
its fastenings. If you intend to install the ladder to the side of the house, we recommend installing
snow guards on both sides of the ladder.
• Choose the leg length so that the rung distance is a minimum of 200 mm measured from the
nearest protruding part (for example the eaves). The legs can be shortened.
• Top rung ± 100 mm from the eaves
• Lowest rung 1100 ± 100 mm from the ground level or other starting point
Placement of wall legs:
• The topmost wall legs are fastened as close to the eaves as possible
• The lowermost wall legs are fastened halfway between the two
lowest rungs
• Maximum distance between wall legs is 3000 mm
• Use an eaves support every time the wall leg length is 50 cm or more.
SUOMESSA TEHTY
The Finnish Quality Since 1960
1
7
15
10
9
9
12
6
13
14
2
3
4
5
11
1
16
10
Ø25
400
450-500
10
9
8 10
WALL LADDER
Installation set AS1
Extra leg set AS1L
Hand rail support
set with tubes AS1T
Back arcs
Climbing protection
Hand rail support
Extension hinge
Side exit
Side fastening
No. Name Code
AS1
pcs.
AS1L
pcs.
1Modular ladder 1,5 m
2,1 m
3,0 m
4,2 m
20010
2 011 0
20050
20070
2Hand rail 20080 2
3Bendable flange 20290 4 2
4 Wall leg 20 cm
25-40 cm
55-70 cm
85-100 cm
115 -13 0 c m
20940
20730
20740
20750
20760
4 2
5Roof ladder fastener 20120 2
6Roof fastener 20130 2
7 Eaves support for over
50cm wall legs
20140 (2)
8Screw M8x16 17031 8 4
9Screw M8x40 17301 10 4
10 Nut M8 17021 18 8
11 Screw 7x50 17271 14 4
12 Hand rail support set* 35620
13 Hand rail roof bridge* 20260
14 Lower arc* 20250
15 Oval plug, black* 20150
16 Hand rail support, tubular* 20540
*Compatible product
200
1100 ± 100 ± 100
max. 3000
19.11.2 018

www.orima.fi
© Copyright Orima-Tuote Oy. Kankaantie 6, FI-16300 Orimattila
Unauthorised use and copying is forbidden.
ISO 9001
BUREAU VERITAS
Certification
No FIHSK10155078A
WALL LADDER
INSTALLATION INSTRUCTIONS
FASTENING THE WALL LEGS
When fastening wall legs, choose the fastening accessories according to the wall material. The legs are always fastened to the wall’s support structures
whenever possible. Install the wall legs so that they are a little wider apart compared to the ladder rails to make the ladder more laterally stable.
FASTENING THE HAND RAILS
Fasten the hand rails whenever possible.
EAVES SUPPORT FASTENER 20140
WOODEN FRAME OR PANEL WALL
• Panel thickness min. 20 mm.
• 2 pcs. 7x50 screws/wall leg.
ROOF FASTENER 20130 FOR ROOF
STRUCTURES
• Fasten the hand rails to the roof
fasteners (M8x40 screw + nut).
• Fasten to roof structures by using
1 pc. 7x50 screw/roof faste-
ner. Ensure that the lead-through
is tight-proof.
CLAMB IRON 23070 FOR TILE ROOF
STEP AND ROOF FASTENER 20130
• Fasten the clamb irons between
two tile roof steps using the oval
holes on the sides (M8x16 sc-
rew + nut).
• Fasten the roof fasteners on the
top surface of the clamb iron
(M8x16 screw + nut).
• Fasten the hand rails to the roof
fasteners (M8x40 screw + nut).
• We recommend using the hand
rail support set (35620).
Code pcs..
Clamb iron 23070 2
Roof fastener 20130 2
Screw M8x16 17031 6
Screw M8x40 17301 2
Nut M8 17021 8
Hand rail support set 35620 1
BLOCK, STONE, AND BRICK WALL
• Nylon or metal plug according
to wall material, and 2 pcs.
7x50 screws/wall leg.
• Alternative fastening with app-
licable wedge or chemical an-
chor.
ROOF LADDER FASTENER 20120 FOR
ROOF LADDERS
• Place the roof ladder fastener
around the ladder rail and fas-
ten it to the hand rails (M8x40
screw + nut/hand rail).
BRICK WALL BEFORE BRICKLAYING
• Fasten to bodywork 2 pcs.
7x50 screws/wall leg.
HAND RAIL FASTENER 20260 FOR
ROOF BRIDGE
• Fasten the hand rail fastener to
the bottom of the roof bridge (2 pcs.
M8x16 screw + nut).
• Fasten the hand rails to the sides
of the roof bridge fastener (M8x40
screw nut/hand rail).
Code pcs.
Roof bridge fastener 20260 1
Screw M8x16 17031 2
Screw M8x40 17301 2
Nut M8 17021 4
PAROC FASTENER 20640 FOR
SANDWICH STRUCTURES
• Start by attaching the legs to the
Paroc fastener by using 2pcs.
M8x16 screws and nuts/wall
leg.
• Fasten the Paroc fastener to the
wall by using 14 pcs. 4.8x25
roofing screws or 7x50 screw/
fastener.
Use an eaves support fastener whe-
never the wall leg is 50 cm or lon-
ger.
• Fasten the eaves support faste-
ner to the topmost wall leg pair
(M8x40 screw + nut).
• Fasten to eaves by using 2 pc.
7x50 screw/fastener.
• Fasten to bodywork whenever
possible.
2
450-500
450-500
450-500
19.11.2 018

www.orima.fi © Copyright Orima-Tuote Oy. Kankaantie 6, FI-16300 Orimattila
Unauthorised use and copying is forbidden.
ISO 9001
BUREAU VERITAS
Certification
No FIHSK10155078A
SIDE FASTENING
SAFETY EQUIPMENT FOR LADDERS
Wall ladders that rise to 8 m or higher must be equipped with a safety rail
or back arc.
CLAMB IRON 23070 FOR TILE ROOF
STEP AND ROOF FASTENER 20130
• Fasten the clamb irons between
two tile roof steps using the oval
holes on the sides (M8x16 sc-
rew + nut).
• Fasten the roof fasteners on the
top surface of the clamb iron
(M8x16 screw + nut).
• Fasten the hand rails to the roof
fasteners (M8x40 screw + nut).
• We recommend using the hand
rail support set (35620).
Code pcs..
Clamb iron 23070 2
Roof fastener 20130 2
Screw M8x16 17031 6
Screw M8x40 17301 2
Nut M8 17021 8
Hand rail support set 35620 1
SAFETY RAIL
• Distance of the safety rail’s lo-
wer end from the ground min.
1.9 m.
• Install the ladder’s wall legs clo-
ser to one another than the nor-
mal 3 m interval.
Code
Exit arc 2.6 m 33870
Safety rail 3 m 33800
Extension set 33840
Rung clamp set 33860
Fall arrester 33880
For more details, see the installation
instructions for access rails at
www.orima.fi
3
WALL LADDER
ACCESSORIES
SUPPORTING THE HAND RAILS
AS1T
HAND RAIL SUPPORT SET, TUBULAR
• Use this when hand rails are not
fastened. Shorten the hand rail if
necessary.
• Fasten the cut end of the support to
the hand rail.
• Fasten the support’s other end to
the ladder rail by using a bendab-
le flange.
AS1T Code pcs.
Hand rail support, tub. 20540 2
Bendable flange 20290 2
Screw M8x16 17031 4
Screw M8x40 17301 4
Nut M8 17021 8
SIDE FASTENING SET 20270
• Distance from wall: 200 mm.
• Use applicable fastening accesso-
ries to fasten to a wall (see previous
page, Fastening the wall legs).
• Distance between side fastenings
max. 2.4 m.
20270 Code pcs.
Pull bar 373269-1 1
Support bar 373269-2 1
Threaded bar M10
RST
17534 1
Washer M10 17961 1
Nut M10 RST 17374 2
EXIT ARC SET FOR SIDES 33780
• Height and width 1 m.
• Can be mounted for exiting to the
right or to the left.
33780 Code pcs.
Side exit arc 33770 1
Arc fastener set 33220 1
Extension set 33840 1
Rung clamp set 33860 1
Detachable carriage 33810 1
Hand rail set for side 20890
Fall arrester 33880
HAND RAIL SUPPORT SET 35620
• Fasten the hand rail supports
in place at the middle holes
(M8x40 screw + nut).
• Drill mounting holes in the hand
rails and ladder rails.
• Fasten the support set.
35620 Code pcs.
Hand rail support 20410 4
Screw M8x40 17301 6
Nut M8 17021 6
BACK ARCS
When using back arcs, the ladder’s
hand rails must be installed inverted!
• Installation interval for back arc
is 900 mm.
• The lowermost safety arc at
~2.5 m from the starting level.
• Install the ladder’s wall legs clo-
ser to one another than the nor-
mal 3 m interval.
BACK ARC SET 1,8 m
SDS Code pcs.
Back arc 24010 3
Vertical bar 24020 8
Back arc installation set 35271 3
BACK ARC ADDITIONAL SET 0,9 m
SDSL Code pcs.
Back arc 24010 1
Vertical bar 24020 4
Back arc installation set 35271 1
900
~2500
~1900
200
570
1000
850
1000
<2400
19.11.2 018

www.orima.fi
© Copyright Orima-Tuote Oy. Kankaantie 6, FI-16300 Orimattila
Unauthorised use and copying is forbidden.
WALL LADDER
USAGE, MAINTENANCE
AND GUARANTEE
USAGE
All buildings must offer a passageway to the roof so that all objects, such as
the chimney, battens, roof safety, lead-throughs, and electronic equipment
can be checked and serviced in a safe manner. Orima®wall ladders provi-
de a safe passage to the building’s roof.
Once the ladder’s rise exceeds 8 m, you should equip your ladder with
safety rails or back arcs. The Orima®wall ladders can be used as an at-
tachment point for a lifeline.
The ladder and the fastenings can withstand a minimum vertical point load
of 2.6 kN and a minimum vertical total load of 3.9 kN per every three met-
res. The wall ladder’s hand rail and its fastening can withstand a minimum
0.5 kN horizontal outward force.
MAINTENANCE AND INSPECTION
Yearly maintenance and inspection procedures for Orima®wall ladders:
• Visual checking of general appearance, such as damage on ladder
structures due to snow loads or other strain, damage to paint coatin-
gs, visible corrosion, loose fastenings, and so on.
• Grip and tightness of fastening points, joints, and fastening equip-
ment
• Checking the roof fastenings and lead-throughs for tightness
• Removing excess snow load from the roof as required
• Clearing the ladder of snow, ice, and other dirt
• Touch-up painting of damaged coatings and replacing or repairing
damaged or faulty parts.
GUARANTEE AND QUALITY
GUARANTEE: Under the warranty terms, Orima® guarantees
that the factory-treated product will not rust during the warranty
period due to a manufacturing or material defect. Orima-Tuo-
te ensures that the product fulfills and withstands the functional
requirements and regulations set for it when the installation,
maintenance and inspection measures have been carried out
in accordance with the instructions and regulations. The war-
ranty period is 50 years.
ISO 9001:2015: This product has been manufactured un-
derthe controls established by a Bureau Veritas Certificati-
on approved management system that conforms with ISO
9001:2000. Bureau Veritas Certification Certificate Number
FIHSK10155078A.
VTT VERIFICATION CERTIFICATE VTT-VA-00001-18:
Product and intended use:
Orima®Wall ladder, prefabricated accessory for roofing – lad-
ders for mounting the roof of a building or another level.
Performance levels:
1. DIMENSIONS: Width of rung 400 mm, diameter 25 mm,
step interval 300 mm, distance between rung and wall > 200 mm
2. THICKNESS OF COATING: Zn 20 μm + powder stove painting min 60 μm
3. LOAD AND TORQUE CAPACITY:
STATIC LOAD CAPACITY: 2.6 kN load Bend at 1.5 kN load
Rung Load capacity Max 5 mm
Side support Load capacity 1/100 of length of support
interval, max 10 mm
Ladder mounting and support Load capacity –
TORQUE CAPACITY: 50 Nm torsional strength test
Ladder rung mounting Load capacity
DYNAMIC LOAD CAPACITY: 100 kg load from falling mass, dropping height
2,500 mm
Ladder Load capacity
Vertical safety rail Load capacity
4. CORROSION: Loading and durability class at 240 h condensate test C4 fair
(requirement for prefabricated accessories for roofing: C3 medium).
4
ISO 9001
BUREAU VERITAS
Certification
CLIMBING PROTECTION
• Hung on a rung.
• For locking, a hole for a long
shackle padlock.
Code
Climbing protection 0.9 m 20400
Climbing protection 2.1 m 20440
Climbing protection 2,1 m
for ladder with safety rails
20340
EXTENSION HINGE SET 35630
The height of the extension hinge must not exceed 2 m. The ladder is locked
in the up position by using a long shackle padlock.
• Assemble the hinge (M8x25 screw + 2 pcs. M8 nuts)
• Fasten the hinge to the holes at the uncut end of the ladder (M8x40 sc-
rew + nut).
• Drill the other holes onto the rails of the lower ladder.
• Fasten the hinge’s lower part to the holes you drilled (M8x40 screw +
nut).
35630 Code pcs.
Extension hinge 1/2 20470 4
Screw M8x25 17041 2
Screw M8x40 17301 8
Nut M8 17021 12
WALL LADDER
ACCESSORIES
CLIMBING PROTECTION
Used in buildings and other places where it is necessary to stop, for
example, children from climbing the ladder.
3. 4.
2.
1.
50
W
A
R
R
A
N
T
Y
Y
E
A
R
S
ROOF SAFETY PRODUCTS
& LADDERS
19.11.2 018
100
31
12
This manual suits for next models
2