manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ORiNG
  6. •
  7. Network Router
  8. •
  9. ORiNG RGS-92222GCP-NP Series User manual

ORiNG RGS-92222GCP-NP Series User manual

35.50
44.00
8.00 20.00
24.00
32.0
5.50
R3.25
25.50
2.50
4.30
17.80
30.20 82.00
342.00
58.8
ACPower SWITCH
49.0
3.0
AC100-240V
50-60HZ
PW1
44.00
431.00
G2 G4 G6 G8
G1 G3 G5 G7
LINK/ACT
Console
RGPS-92222GCP-NP-E
R.M.
Ring
Reset
10/100/
1000T
Fault
100/1000X
G10 G12 G14 G16
G9 G11 G13 G15
G18 G20 G22
G17 G19 G21 G23
G24
PW1
14.2
Quick Installation Guide
Version 1.0
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
RGS-92222GCP-NP Series
QIG RGS-92222GCP-NP Series 1907-2-29-RGS92222GCPNP-1.0
The which consist of , and
, are managed Ethernet switches designed for
industrial applications. uring 22 10/100/1000Base-T(X) ports, 2
Gigabit combo ports and 2 100/1000Base-X SFP ports, the series is
able to meet the needs for high port density and high-speed, long-
distance transmission. The is an enhanced model
with dual DC inputs and relay output. With complete support for Ethernet
redundancy protocols such as O-Ring (recovery time < 30ms over 250 units
of connection) and MSTP (RSTP/STP compatible), the series can protect
your mission-critical applications from network interruptions or temporary
malfunctions with its fast recovery technology. Featuring a wide operating
temperature from -40 C to 75 C, the device can be managed centrally and
conveniently via Open-Vision, web browsers, Telnet and console (CLI)
configuration, making it one of the most reliable choice for highly-managed
and Fiber Ethernet power substation and rolling stock application.
RGS-92222GCP-NP series RGS-92222GCP-NP
RGS-92222GCP-NP-E
RGS-92222GCP-NP-E
Feat
oo
Dimension
Panel Layouts
1. Console port
2. Reset button
3. Power indicator
4. Ring status LED
5. RM status LED
6. LAN ports
Front View
Rear View
Installation
Rack-mounting
Step 1:
Step 2:
Install left and right front mounting brackets to the switch using four screws on each side.
With front brackets orientated in front of the rack, fasten the brackets to the rack using two
more screws.
Network Connection
Package Contents
MANAGED
Rack-Mount
GIGABIT
SWITCH
Managed Gigabit Ethernet Switch
1
2 3 4 569
10
11 12
7. LED for Ethernet ports link/act status
8. LED for Ethernet ports Speed indicator
9. First Gigabit combo port
10. Second Gigabit combo port
11. SFP ports
12. LNK/ACT LED for SFP ports
13. Fault indicator
1 2
1. Power switch
2. AC power input (100V~240V
/ 50~60Hz)
3. Dual DC power inputs
The switch provides standard Ethernet ports. According to the link type, the switch uses CAT
3,4,5,5e UTP cables to connect to any other network devices (PCs, servers, switches,
routers, or hubs). Please refer to the following table for cable specifications.
Cable Types and Specifications:
Cable Type Max. Length Conn ector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm U TP UTP 100 m (328 ft) RJ-45
1000BASE-T Cat. 5 / Cat. 5e 100-ohm UTP UTP 100 m (3 28 ft) R J-45
With 10/100BASE-T(X) cables, pins 1 and 2 are used for transmitting data, and pins 3 and 6 are
used for receiving data. The device also supports auto MDI/MDI-X operation. You can use a
cable to connect the switch to a PC
For pin assignments for different types of cables, please refer to the following
tables.
Contents
QIG
CD
Console Cable
RGS-92222GCP-NP
or
RGS-92222GCP-NP-E
RGS-92222GCP-NP
Rack-mounted
kit (L&R)
Pictures Number
X1
X1
X1
X1
X1
Power Cable X1
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Elevated Operating Ambient: If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Safety & Warnings
Reduced Air Flow:
Mechanical Loading:
Circuit Overloading:
Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
44.00
443.70 58.00
42.70
26.70 24.00
24.00
30.20
3.90
R3.50
19.00
3.70
4.30
17.80
30.20 238.00
15.90
6.60
200.00
G2 G4 G6 G8
G1 G3 G5 G7 G9 G11 G13 G15
G10 G12 G14 G16
G17 G19 G21 G23
G18 G20 G22 G24
LINK/ACT
Console
10/100/
1000T
AC100-240V
50-60HZ
215.5 49.0
3.0
RGS-92222GCP-NP
Reset
R.M.
Ring
PWR
G23 G25 G26
100/1000X
AC 100-240V
50-60 HZ
G2 G4 G6 G8
G1 G3 G5 G7 G9 G11 G13 G15
G10 G12 G14 G16
G17 G19 G21 G23
G18 G20 G22 G24
LINK/ACT
Console
10/100/
1000T
RGS-92222GCP-NP
Reset
R.M.
Ring
PWR
G23 G24 G25 G26
100/1000X
7 8
10/100Base-T(X) RJ-45 port
Pin Number Assignment
#1 TD+
#2 TD-
#3 RD+
#6 RD-
1000Base-T RJ-45 port
Pin Number Assignment
#1 BI_DA+
#2 BI_DA-
#3 BI_DB+
#4 BI_DC+
#5 BI_DC-
#6 BI_DB-
#7 BI_DD+
#8 BI_DD-
RGS-92222GCP-NP-E
Rack-mounted
kit (L&R)
X1
RGS-92222GCP-NP
RGS-92222GCP-NP-E
G24
G23 G25 G26G24
PW2
PW3
G2 G4 G6 G8
G1 G3 G5 G7
LINK/ACT
Console
RGPS-92222GCP-NP-E
R.M.
Ring
Reset
10/100/
1000T
Fault
100/1000X
G10 G12 G14 G16
G9 G11 G13 G15
G18 G20 G22
G17 G19 G21 G23
G24
PW1
G23 G25 G26G24
PW2
PW3
1
2 3 4 56911 12
7 8 10
13
RGS-92222GCP-NP-E
RGS-92222GCP-NP
ACPower SWITCH
AC100-240V
50-60HZ
PW1
1 2 3
RGS-92222GCP-NP-E
RGS-92222GCP-NP
V+ V- V- V+
3A@24V
DCPower 48V
PW2 PW3
V+ V- V- V +
3A@24V
DCPower 48V
PW2 PW3
QIG Quick Installation Guide
PRINTED ON RECYCLED PAPER
Version 1.0
Quick Installation Guide
Resetting
To reboot the switch, press the button for 5 seconds.
To restore the switch configurations back to the factory defaults, press the button for 10
seconds.
Reset
Reset
Specifications
ORing Switch Model
Physical Ports
Technology
Ethernet Standards
10/100/1000Base-T(X) with
Ports in RJ45 Auto MDI/MDIX
Switch Properties
Security Features
Device Binding security feature
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
Single 802.1x and Multiple 802.1x
MAC-based authentication
QoS assignment
Guest VLAN
MACaddresslimit
TACACS+
VLAN (802.1Q) to segregate an secure network traffic
Radius centralized password management
SNMPv3 encrypted authentication and access security
Https / SSH enhance network security
Web and CLI authentication and authorization
Authorization (15 levels)
IP source guard
22
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX,
IEEE 802.3z for 1000Base-X,
IEEE 802.3ab for 1000Base-T,
IEEE 802.3x for Flow control,
IEEE 802.3ad for LACP (Link Aggregation Control Protocol )
IEEE 802.1p for COS (Class of Service)
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol)
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
Switch latency: 7 us
Switch bandwidth: 52Gbps
Max. Number of Available VLANs: 4095
VLAN ID Range : VID 1 to 4094
IGMP multicast groups: 128 for each VLAN
Port rate limiting: User Define
MAC Table 8K
Processing Store-and-Forward
Priority Queues 8
Jumbo frame Up to 9.6K Bytes
Environmental
-40to85C(-40to185F)
oo
Storage Temperature
Operating Temperature
Physical Characteristic
Dimension(WxDxH)
Weig ht (g ) 2850g
5% to 95% Non-condensing
Operating Humidity
Regulatory Approvals
Enclosure 19 inches rack mountable
443.7 (W) x 200 (D) x 44 (H) mm
(17.47x7.87x1.73inches)
FCC Part 15, CISPR (EN55022) class AEMI
EN61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-4 (EFT)
EN61000-4-5 (Surge)
EN61000-4-6 (CS)
EN61000-4-8
EN61000-4-11
EMS
Warranty
5 years
Warranty
5 years
Managed Gigabit PoE Ethernet Switch
RGS-92222GCP-NP
Gigabit Combo port with
10/100/1000Base-T(X) and
100/1000Base-X SFP ports
2
100/1000Base-X with SFP port 2
-40to75C(-40to167F)
oo
IEC60068-2-27Shock
IEC60068-2-32Free Fall
IEC60068-2-6Vibration
EN60950-1Safety
Console cable
Use the provided DB-9 cable (RS-232 cable) to connect the switch to a PC with the DB-
9 connector attached to the switch console port and the DB-9 female connector to the
PC.
PC pin out (male)
assignment
RS-232 with DB 9
female connector
Pin#2RD Pin#2TD
Pin #3 TD Pin #3 RD
Pin #5 GND Pin #5 GND
RS-232 Serial Console Port
Software Features
IEEE 802.1D Bridge, auto MAC address learning/aging and MAC address (static)
Multiple Registration Protocol (MRP)
MSTP RSTP/STP compatible)
RedundantRing(O-Ring)withrecoverytimelessthan30msover250units
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging
IGMP v2/v3 Snooping
IP-based bandwidth management
Application-based QoS management
DOS/DDOS auto prevention
Port configuration, status, statistics, monitoring, security
DHCP Server/Client
DHCP Relay
Modbus TCP
DNS client proxy
SMTP Client
NTP server
(
Network Redundancy O-Ring, Open-Ring, O-Chain, MRP, Fast Recovery, MSTP (RST/PSTP compatible)
RS-232 in DB-9 connector with console cable. 115200bps, 8, N, 1
Power
Power consumption(Typ.) 22 Watts
Overload current protection Present
Overload current protection 100~240VAC with power socket
MANAGED
Rack-Mount
GIGABIT
SWITCH
10/100 Base-T(X) MDI/MDI-X
Pin Number MDI port MDI-X port
1TD+(transmit)RD+(receive)
2TD-(transmit)RD-(receive)
3 RD+(recei ve) TD+(transmit)
4NotusedNotused
5NotusedNotused
6 RD-(receive) TD-(transmit)
7NotusedNotused
8NotusedNotused
1000Base-T MDI/MDI-X
Pin Number MDI port MDI-X port
1 BI_DA+ BI_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5 BI_DC- BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8BI_DD-BI_DC-
Wiring
AC Power Connection
Both RGS-92222GCP-NP and RGS-92222GCP-NP-E can be powered by AC electricity.
Simply insert the AC power cable to the power connector at the back of the
switch and turn on the power switch. The input voltage is 100V~240V / 50~60Hz.
DC Power Connection
The RGS-92222GCP-NP-E supports dual DC power
supplies, Power Supply 1 (PWR1) and Power Supply 2
(PWR2). The connections for PWR1, PWR2 and the RELAY
are located on the terminal block. The input voltage is
36V~72VDC.
STEP 1:
STEP 2:
Insert the negative/positive wires into the V-/V+ terminals, respectively.
To keep the DC wires from pulling loose, use a small flat-blade
screwdriver to tighten the wire-clamp screws on the front of the terminal block
connector.
Relay contact
Grounding
The RGS-92222GCP-NP-E provides two sets of relay contacts on the 6-pin terminal
block to detect user-configured events. The two wires attached to the fault contacts
form an open circuit when a user-configured when an event is triggered. If a user-
configured event does not occur, the fault circuit remains closed.
The RGS-92222GCP-NP-E provides grounding and wire routing to help limit the
effects of noise due to electromagnetic interference (EMI). Run the ground connection
from the ground screws to the grounding surface prior to connecting devices.
ORing Industrial Networking Corp.
Copyright© 2015 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oring-networking.com
E-mail: [email protected]
Configurations
After installing the switch and connecting cables, start the switch by turning on power.
The green power LED should turn on.
LED indication table
1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is
192.168.10.1
2. Log in with default user name and password (both are ). After logging in, you should see
the following screen. For more information on configurations, please refer to the user manual. For
information on operating the switch using ORing’s Open-Vision management utility, please go to
ORing website.
admin
LED Color Status Descriptio n
Green On System power on
PWR
Green Blinking Upgrading firmware
R.M Green On Ring Master
On Ring enabled
Ring Green
Blinking Ring structure is br oken
Fault Amber On Errors (For port malfunctioning)
10/100/ 1000Base-T( X) RJ45 port
On Port connected
Link/Act Green
Blinking Transmitting data
Green On Port is running at 1000Mbps
Amber On Port is running at 100Mbps
Speed
Green / Amber Off Port is running at 10Mbps
100/1000 Base-X SFP port
On Port connected
Link/Act Green
Blinking Transmitting data
RGS-92222GCP-NP-E
Fault contact
Relay None Relay output to carry capacity of 1A at 24VDC
100~240VAC with power socke, and dual 48VDC
(36 ~72VDC) power inputs at 6-pin terminal block
23 Watts
ReversePolarityProtectionon
DC input(s) -Present
4360g
441(W)x342(D)x44(H)mm
(17 x 13.46 x 1.73 inches)
RGS-92222GCP-NP Series
RGS-92222GCP-NP Series
V+ V- V- V+
3A@24V
DC Power 48V
PW2 PW3

Other ORiNG Network Router manuals

ORiNG CPGS-9080-C User manual

ORiNG

ORiNG CPGS-9080-C User manual

ORiNG IAR-620 User manual

ORiNG

ORiNG IAR-620 User manual

ORiNG RGPS-7244GP-P User manual

ORiNG

ORiNG RGPS-7244GP-P User manual

ORiNG TGPS-9164GT-M12X-BP2-MV User manual

ORiNG

ORiNG TGPS-9164GT-M12X-BP2-MV User manual

ORiNG TGXPS-1080-M12-MV Series User manual

ORiNG

ORiNG TGXPS-1080-M12-MV Series User manual

ORiNG TGPS-9164GT-M12 User manual

ORiNG

ORiNG TGPS-9164GT-M12 User manual

ORiNG TGXS-1080-M12-MV Series User manual

ORiNG

ORiNG TGXS-1080-M12-MV Series User manual

ORiNG IAR-630-D User manual

ORiNG

ORiNG IAR-630-D User manual

ORiNG IAR-630-C User manual

ORiNG

ORiNG IAR-630-C User manual

ORiNG TGAR-W1061 Plus-3G-M12 User manual

ORiNG

ORiNG TGAR-W1061 Plus-3G-M12 User manual

ORiNG IES-P3073GC Series User manual

ORiNG

ORiNG IES-P3073GC Series User manual

ORiNG TPS-3082GF-MM-M12-QODC User manual

ORiNG

ORiNG TPS-3082GF-MM-M12-QODC User manual

ORiNG TES-3082GT-M12-BP1 User manual

ORiNG

ORiNG TES-3082GT-M12-BP1 User manual

ORiNG RGPS-7244GP User manual

ORiNG

ORiNG RGPS-7244GP User manual

ORiNG TES-180-M12 User manual

ORiNG

ORiNG TES-180-M12 User manual

ORiNG IES-1080A User manual

ORiNG

ORiNG IES-1080A User manual

ORiNG IES-3242GC User manual

ORiNG

ORiNG IES-3242GC User manual

ORiNG IES-3080 Series User manual

ORiNG

ORiNG IES-3080 Series User manual

ORiNG RGS-PR9000 User manual

ORiNG

ORiNG RGS-PR9000 User manual

ORiNG IES-2050A User manual

ORiNG

ORiNG IES-2050A User manual

ORiNG IR-710 User manual

ORiNG

ORiNG IR-710 User manual

ORiNG RGPS-R9244GP+-P Series User manual

ORiNG

ORiNG RGPS-R9244GP+-P Series User manual

ORiNG IGCS-E131GP User manual

ORiNG

ORiNG IGCS-E131GP User manual

ORiNG TGS-9200-M12-BP2 User manual

ORiNG

ORiNG TGS-9200-M12-BP2 User manual

Popular Network Router manuals by other brands

Micro control systems MCS-WIRELESS-3G Installation and reference guide

Micro control systems

Micro control systems MCS-WIRELESS-3G Installation and reference guide

HP FlexNetwork HSR6800 Configuration guide

HP

HP FlexNetwork HSR6800 Configuration guide

B&B Electronics EIR203 quick start guide

B&B Electronics

B&B Electronics EIR203 quick start guide

Hootoo HT-TM02 TripMate Nano user guide

Hootoo

Hootoo HT-TM02 TripMate Nano user guide

H3C S5500-SI Series Operation manual

H3C

H3C S5500-SI Series Operation manual

HP J2600A installation guide

HP

HP J2600A installation guide

Juniper T320 Hardware guide

Juniper

Juniper T320 Hardware guide

Pakedge RT-3100 quick start guide

Pakedge

Pakedge RT-3100 quick start guide

DeWalt DCW600 manual

DeWalt

DeWalt DCW600 manual

Linksys RV082 Quick installation

Linksys

Linksys RV082 Quick installation

Belkin High Speed ADSL2+ user manual

Belkin

Belkin High Speed ADSL2+ user manual

ENJsoft WifiAn-Mini user manual

ENJsoft

ENJsoft WifiAn-Mini user manual

Enterasys Matrix-V V2H124-24P Quick reference guide

Enterasys

Enterasys Matrix-V V2H124-24P Quick reference guide

qpcom QP-S108 user manual

qpcom

qpcom QP-S108 user manual

TP-Link TL-ER604W datasheet

TP-Link

TP-Link TL-ER604W datasheet

AUTOHELM NMEA BRIDGE user guide

AUTOHELM

AUTOHELM NMEA BRIDGE user guide

Kodak Carousel S-AV B instruction manual

Kodak

Kodak Carousel S-AV B instruction manual

Cisco 815 Hardware installation guide

Cisco

Cisco 815 Hardware installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.