This installation guide describes the hardware of the
eWON COSY 131 and explains how to get started
with the embedded web site.
nstallation Guide
G 022 / Rev. 1.4

Table of Contents
1. Product Summary .............................................................................................................
1.1. ntroduction ...................................................................................................................................... 4
1.2. Concept of the eWON COSY 131 Family ................................................................................... 4
1.3. General specification of the hardware platform ..................................................................... 4
1.4. Typical applications ........................................................................................................................ 4
1.5. Type and Part Numbers ................................................................................................................. 5
2. Safety, Environmental & Regulatory Information ........................................................... 6
2.1. Scope ................................................................................................................................................ 6
2.2. Power supply .................................................................................................................................... 6
2.3. Applicable Directives, Standards and Compliance ................................................................ 6
2.3.1. Applicable European Directives ........................................................................................ 6
2.3.2. Applicable Safety Standards ............................................................................................. 7
2.3.3. FCC Compliance .................................................................................................................. 7
2.3.4. Certifications .......................................................................................................................... 7
2.4. Field implementation & environmental conditions .................................................................. 7
2.4.1. ngress Protection .................................................................................................................. 7
2.4.2. Mounting Recommendations ............................................................................................ 7
2.4.3. Cabling rules ........................................................................................................................ 10
2.4.4. Environmental conditions .................................................................................................. 10
2.4.5. Earthing ................................................................................................................................. 10
2.5. Battery ............................................................................................................................................. 10
3. Hardware description .................................................................................................... 11
3.1. Label ................................................................................................................................................ 11
3.2. Mechanical dimensions ............................................................................................................... 13
3.3. Overal description ........................................................................................................................ 13
3.3.1. Front ....................................................................................................................................... 13
3.3.2. Upper side ........................................................................................................................... 14
3.3.2. Status LED panel (COSY 131 – All version): ..................................................................... 14
3.3.3.1. Status LED panel (COSY 131 - WiFi) ............................................................................ 15
3.3.3.2. Status LED panel (COSY 131 - Cellular 3G+) ........................................................... 15
3.4. Radio communication models ................................................................................................... 16
3.4.1. COSY 131 with internal WiFi modem ............................................................................... 16
3.4.2. COSY 131 with internal 3G+ Penta modem .................................................................. 17
3.5. LAN Switch Specifications ........................................................................................................... 18
3.5.1. Boot process ........................................................................................................................ 18
. COSY IP Address & Access to the Web Configuration ................................................ 19
4.1. Factory Default P settings ........................................................................................................... 19
4.2. Powering ON .................................................................................................................................. 19
4.3. Setting the eWON COSY LAN P Address .................................................................................. 19
4.4. eWON COSY's Web nterface .................................................................................................... 21
5. Troubleshooting .............................................................................................................. 2
5.1. Normal Boot Process ..................................................................................................................... 24
5.2. Resetting the eWON COSY 131 .................................................................................................. 24
5.3. First Level Reset (user reset) ......................................................................................................... 24
Page 2 / 30 eWON COSY 131 | G 022

Table of Contents
5.4. Second Level Reset (factory reset) ........................................................................................... 24
5.5. Reset mpact Matrix ...................................................................................................................... 25
Appendix A - Connector Pinout & Related Specifications ............................................. 26
A.1 - Main Connector ......................................................................................................................... 26
A.2 - Specification of the External Power Supply ........................................................................... 27
A.3 - Digital Output & Digital nputs .................................................................................................. 27
A.4 - Used Wireless Frequencies ......................................................................................................... 29
Revision .............................................................................................................................. 30
Revision History ..................................................................................................................................... 30
Page 3 / 30 eWON COSY 131 | G 022

Chapter 1
Product Summary
1. Product Summary
1.1. Introduction
The present nstallation Guide describes the hardware of the eWON COSY 131 family.
The eWON Cosy 131 family is a set of 3 industrial gateways/routers.
The eWON Cosy 131 is fully compatible with the Talk2M cloud connectivity services
(www.talk2M.com).
1.2. Concept of the eWON COSY 131 Family
The Cosy 131 is available in 3 different versions depending on their communication
interface:
•Ethernet Switch Cosy 131 Ethernet
•WiFi & Ethernet Switch Cosy 131 WiFi
•3G+ & Ethernet Switch Cosy 131 Cellular 3G+
1.3. General specification of the hardware platform
Characteristic Value
Design ndustrial design (24 VDC power supply, D N Rail
mounting, extended temperature)
Processor ARM9
Clock Backed up real time clock (RTC)
Backup battery lifetime has 10 years expectancy
Ethernet nterface LAN Ethernet port 10/100 Mbps
Digital nput 2
Digital Output 1
Mounting Latch for D N rail EN50022-compliant
1. . Typical applications
•Remote Access of Ethernet devices using Talk2M connection
•ndustrial VPN router
Page 4 / 30 eWON COSY 131 | G 022

Chapter 1
Product Summary
1.5. Type and Part Numbers
The available part numbers are:
Part Number Type Description
EC61330_00MA COSY 131 LAN/WAN – Ethernet Only Switch 4-Ports
EC6133C_00MA COSY 131 LAN/WAN, W F – Ethernet Switch + WiFi
EC6133D_00MA COSY 131 LAN/WAN -3G+ Penta - Ethernet Switch + 3G+
Table: List of the available part numbers
- Note -
The MA suffix means Multiple languages A (ENG, FR, E, SP)
The part number syntax is explained in 3.1. Label
Page 5 / 30 eWON COSY 131 | G 022

Chapter 2
Safety, Environmental & Regulatory nformation
2. Safety, Environmental & Regulatory Information
2.1. Scope
The present heading addresses Safety, Environmental & Regulatory nformation for the
eWON Cosy 131 family.
2.2. Power supply
The external power supply is a third party device that is not part of this certification.
The device shall be supplied by a LPS power supply certified according to EC/UL60950-1 or
Class 2 per NEC (See annex A.2. Specification of the External Power Supply for detailed
information).
2.3. Applicable Directives, Standards and Compliance
The product described in the present nstallation Guide complies with the CE, R&TTE
directives and the FCC regulations related to the wireless modems.
The product described in the present nstallation Guide belongs to class A nformation
Technology Equipment ( TE). n a domestic environment this product may cause radio
interference in which case the user may be required to take appropriate measures.
2.3.1. Applicable European Directives
The product described in the present nstallation Guide is in conformity with the following EC
directives:
•RoHS Directive 2011/65/EU
•EMC Directive 2004/108/EC
•R&TTE Directive 1999/5/EC (for versions includind RF modems)
The product conforms to the corresponding R&TTE articles:
RF spectrum efficiency (Art 3.2); EMC (Art. 3.1b); Safety (Art. 3.1a)
•REACH Directive 2006/121/EC
•For COSY 131, Cellular 3G+ only: to comply with R&TTE directive
•Antenna must be mounted on a grounded plate
•RF suppressors must be mounted on the power supply cable in the following
order, starting at 3cm of the connector and going to the power supply:
Wurth Elecktronik 742-717-33
Wurth Elecktronik 742-716-22
Wurth Elecktronik 742-711-11
Page 6 / 30 eWON COSY 131 | G 022

Chapter 2
Safety, Environmental & Regulatory nformation
2.3.2. Applicable Safety Standards
The product described in the present nstallation Guide is in conformity with the following
safety standards:
•EC/EN 60950-1
•UL 60950-1
•CSA-C22.2 No 60950-1-07
2.3.3. FCC Compliance
The product described in the present nstallation Guide complies with Part 15 of the FCC
Rules. Operating is subject to the following two conditions:
•This device may not cause harmful interference, and
•This device must accept any interference received, including interference that may
cause undesired operation.
2.3. . Certifications
The product described in the present nstallation Guide has been certified by authorized
bodies:
•UL Certificate Of Compliance (CoC) for Ordinaty Locations # E350576 for a TMRA of
60°C
•CB certificate # DK-42240-UL
These certificates can be downloaded as PDF files on the eWON Support web site:
http://support.ewon.biz/official-documents
2. . Field implementation & environmental conditions
2. .1. Ingress Protection
The eWON COSY 131 has an P20 protection grade. Therefore, the eWON COSY is NOT suited
for outdoor mounting. t has to be integrated in an electrical cabinet, protected from
excessive heat, humidity and dust. Do not push any sharp object into the air vents or
openings of the equipment.
2. .2. Mounting Recommendations
The normal mounting position of the eWON COSY is wall mounted on a horizontal Omega
type D N-rail (EN 50022).
•Mounting the unit on DIN-rail
Pull the slide lock (located at the bottom of the unit's back-side) downwards and
present the unit in front of the D N rail. Tilt the eWON upwards in order to hang it on the
upper edge of the D N rail by its hook. Gently tilt the unit downwards until it finds its
original position. Pull the slide lock upwards to fix and lock the unit on the D N rail.
Page 7 / 30 eWON COSY 131 | G 022

Chapter 2
Safety, Environmental & Regulatory nformation
•Removing the unit from DIN-rail
Release the unit by pulling the slide lock downwards while gently tilting the unit
upwards. Free the unit by unhooking it from the upper rail edge. See 2.4.2 Mounting
instructions
The product is intended to be mounted vertically, label on the right side
Installation on DIN-rai Wall mounting position
1 S M card slot
2 D N rail mounting braket
3 Screw holes intended to receive M4 screws with an 8mm diameter head
Page 8 / 30 eWON COSY 131 | G 022
1
1
2
3
3

Chapter 2
Safety, Environmental & Regulatory nformation
To ensure a proper ventilation of the equipment, a free gap of at least 2 cm must be
respected in front of all upper & lower ventilation openings of the unit.
A free gap of at least 1 cm must be respected on each side of the unit.
- Caution -
In any other mounting position than the one explained here above, the specified temperature
has to be derated to -25°C to +40°C.
Page 9 / 30 eWON COSY 131 | G 022

Chapter 2
Safety, Environmental & Regulatory nformation
2. .3. Cabling rules
Shielded cables must be used for Ethernet and USB connectivity to comply with the EMC
requirements.
USB cable must be
•shorter than 3m;
•USB 2.0 type
•Maximum current per contact : 0.5A (or better)
•“A” plug connected to the eWON
2. . . Environmental conditions
The equipment will operate properly within the following environmental limits if it has been
correctly mounted according to the above mentioned recommendations:
Operating T° -25°C to +70°C
Relative Humidity 10 to 95% non-condensing
Operating altitude Up to maximum 2000m
Storage temperature -40 to +70 °C
Storage Humidity 10 to 95% non-condensing
Storage altitude Up to maximum 3000m
2. .5. Earthing
Earthing the eWON is necessary to eliminate unwanted transients (lightning protection) and
to conform to the EMC requirements. Therefore, a functional earth (FE) terminal is available
on the main connector as shown in A.2. Specification of the External Power Supply, Connect
this terminal directly to allow impedance ground. Shielded cables have to be used for
Ethernet and USB to comply with the EMC requirements.
2.5. Battery
The COSY contains a CR2032 battery. This battery is used to maintain the real time clock up-
to-date even when the unit is not powered.
- Caution -
Risk of explosion if battery is replaced by an incorrect type.
The battery is not attended to be replaced on consumer's side. The product shall be returned
to manufacture for replacement.
Page 10 / 30 eWON COSY 131 | G 022

Chapter 3
Hardware description
3. Hardware description
3.1. Label
The identification label of the eWON COSY 131 is placed on the right hand side of the
housing. The different parts of the label are described below:
eWON COSY 131 Ethernet Label Description
PN Part Number
(see syntax table below)
SN
Serial number on the form
YYWW-SSSS-PP
YY = Year of production
WW = Week of production
SSSS = sequential mfg order
PP = product type
MAC MAC address of the Ethernet
adapter
Rating Power supply requirements
Marks CE, UL,... logos if applicable
Marks Description
Conformité Européenne or European Conformity (EC)
0682 Notified Body Number, warrantor of the CE Mark validation
UL Listed (Underwriters Laboratories)
FCC Federal Communications Commission
Page 11 / 30 eWON COSY 131 | G 022

Chapter 3
Hardware description
Label can have variant marks depending of models
eWON COSY 131 WiFi eWON COSY 131 – 3G Penta
EC6133m_ccLL[suffix]
Position(s) Description Acceptable values
EC name of the family EC for eWON COSY
6 number corresponding to the HW platform. 6 for “Cosy 131” platform
1 is communication options 1. 1 One Ethernet
3 s communication options 2. 3 Three Ethernet
3 field communication option. 3 USB
m modem communication option.
0 No modem
C WiFi
D HSUPA Modem
cc is one or more digits or letters
that correspond to software options 00 = no software option
LL Defines the firmware language MA UK + FR + DE + SP
[suffix] can have an optional “/” character
Defines the compliances of the unit S
compliance with the
UL/ EC/EN 60950
standard
Page 12 / 30 eWON COSY 131 | G 022

Chapter 3
Hardware description
3.2. Mechanical dimensions
3.3. Overal description
3.3.1. Front
# Description
1 Reset button
2 Status LEDs panel
3LAN/WAN Ethernet ports and corresponding status LEDs
(Red: WAN / Green: LAN)
4 USB slot
5 SD card slot *
•SD Card is not supported for the moment
Page 13 / 30 eWON COSY 131 | G 022

Chapter 3
Hardware description
3.3.2. Upper side
Connector
1 Main connector including power input terminal, 1DO and 2 D
For more information about the connector see in A.1. Main Connector
3.3.2. Status LED panel (COSY 131 – All version):
Label Description
BI1 Button B 1 input
Green ON = Reset being pressed
PWR Power
Green ON = Power is present
USR User
Green ON+OFF slowly = Unit is OK
RED pattern = special attention required
KEY Digital N 1 – Green = ON: Signal on input 1 detected
See. Digital Output & Digital nputs
DI2 Digital N 2 – Green = ON: Signal on input 2 detected
See. Digital Output & Digital nputs
T2M Talk2M - Green ON = Talk2M VPN connection established
See. Digital Output & Digital nputs
@nternet
Green ON = nternet is configured on the eWON COSY
Page 14 / 30 eWON COSY 131 | G 022
1

Chapter 3
Hardware description
3.3.3.1. Status LED panel (COSY 131 - WiFi)
# Mark Description
1/ SMA male connector for W F antenna
2ST Modem status
Green ON = WiFi connected
3Reception signal level
Red ON = Poor signal
Reception signal level
Red ON = Signal is OK
5Reception signal level
Red ON = Good signal
3.3.3.2. Status LED panel (COSY 131 - Cellular 3G+)
# Mark Description
1/ SMA female connector for GSM antenna
2ST Modem status
Green ON = Modem connected
3Reception signal level
Red ON = Poor signal
Reception signal level
Red ON = Signal is OK
5Reception signal level
Red ON = Good signal
Page 15 / 30 eWON COSY 131 | G 022

Chapter 3
Hardware description
3. . Radio communication models
- Warning -
This device is intended to be used in fixed or mobile applications only (not for portable
applications). The antenna used for this transmitter has to be installed in a space providing a
safe distance of at least 20 cm without encountering any person and must not be co-located
or operating in conjunction with any other antenna or transmitter.
3. .1. COSY 131 with internal WiFi modem
Cosy 131 – Wifi
Item Value(s)
Protocols and Frequencies EEE802.11b/g/n, 2.4GHz - Channels: 1 to 11(inclusive)
Antenna Connector Type RP-SMA
Antenna
(included in the delivery)
Charact. Value(s)
mpedance 50 Ohms
nput Power > 17 dBm, EEE 802.11b
> 15 dBm, EEE 802.11g/n
Tightening
Torque
0.5 Nm. In the absence of a torque
wrench, a soft manual tightening is
sufficient.
Device conformity has been tested with the reference antenna: Pulse W1030.
•The product complies with the R&TTE directive, the FCC, the C and Japan regulations
related to the Wifi communications.
•Absolute maximum antenna gain as per FCC's rules and regulations, 47CFR:
Part 15C : 2.14dBi
•Modifications cannot be made by the user if it influences the normal behavior of the
device.
•The user shall be informed about modem identification numbers according to their
national authorities.
This product contains part identified as follows by national authorities:
– FCC I : QOQWF111
– IC I : 5123A-BGTWF111
– RRA I : KCC-CRM-BGT-WF111
– GITEKI (MIC) I : 209-J00061
Page 16 / 30 eWON COSY 131 | G 022

Chapter 3
Hardware description
3. .2. COSY 131 with internal 3G+ Penta modem
Cosy 131 – Cellular 3G+
Item Value(s)
Protocols and Frequencies GSM/GPRS/EDGE - 850, 900, 1800, 1900 MHz
UMTS/HSUPA - 800/850, 900,AWS 1700,1900,2100 Mhz
Class 5 bands GPRS/EDGE Class 33
Antenna Connector Type SMA
Antenna
(not included in the delivery*)
Charact. Value(s)
mpedance 50 Ohms
VSWR
<= 5:1 Absolute max. to avoid permanent
damage
<= 2:1 Limit to fulfill all regulatory
requirements
nput Power > 33 dBm (2W) peak power in GSM
> 24 dBm average power in WCDMA
Tightening
Torque
0.5 Nm. In the absence of a torque
wrench, a soft manual tightening is sufficie
Device conformity has been tested with the reference antenna: Taoglas TG.09.0113
As see in 2. .1 Mounting instructions SIM Card Tray is at the rear of the COSY 131
(*) 3G antenna has to be purchased separately, 3G penta band antenna is available from
eWON with FAC90501_0000 as reference
•The product complies with the R&TTE directive, the FCC, the C and Japan regulations
related to the GSM modems.
•Absolute maximum antenna gain as per FCC's rules and regulations, 47 CFR :
– Part 22H : 5.22dBi;
– Part 27 : 3.31dBi;
– Part 24E : 6.45dBi.
•Modifications cannot be made by the user if it influences the normal behavior of the
device.
•The user shall be informed about modem identification numbers according to their
national authorities:
This product contains part identified as follows by national authorities:
– FFC I : RI7HE910
– IC I : 5131A-HE910
– GITEKI (MIC) I : 005-100269
– JATE I : A 12-0318001
Page 17 / 30 eWON COSY 131 | G 022

Chapter 3
Hardware description
3.5. LAN Switch Specifications
3.5.1. Boot process
During the (re)boot process, the eWON prevents the switch feature from working. This means
that it might require little time starting from the power on (or the reboot request) to get the
LAN switch to be fully operational.
When an eWON router is configured to operate a certain way, it is part of the strategy, if no
other method worked, to reboot itself. This is the ultimate eWON strategy to try restoring the
requested communication channels and be consistent with requested configuration.
Page 18 / 30 eWON COSY 131 | G 022

Chapter
COSY P Address & Access to the Web
Configuration
. COSY IP Address & Access to the Web Configuration
.1. Factory Default IP settings
Characteristics Value(s)
LAN P Address 10.0.0.53
LAN Subnet Mask 255.255.255.0
Gateway 0.0.0.0
.2. Powering ON
Power on the unit and wait approximately 25 sec. until the boot process is finished.
After a successful boot process the USR LED is flashing green ON & OFF slowly.
f the USR LED is flashing RED according to a given pattern, it indicates that the boot process
was interrupted due to a problem. Most frequent problems include :
•a duplicate P address was detected on the LAN Network
USR LED flashing pattern is RED 1x short, 1x long
For the other LED patterns in case of error, please refer to the General Reference
Guide RG-001.
.3. Setting the eWON COSY LAN IP Address
You can easily establish your first communication with your eWON COSY by using our
companion tool eBuddy which can be downloaded from http://support.ewon.biz/software
Connect one of the LAN-ports (by default, port No. 1 is always a LAN port) of your COSY with
your PC point-to-point or through a network where there is no risk that the eWON's default
P-address (10.0.0.53) would conflict with another connected device.
Start the eBuddy application. This one scans the network through the Ethernet adapter and
retrieves the connected eWON, including its P address, Subnet Mask and serial number. The
application also allows you to change the default P address without being necessarily in
the same network range.
Page 19 / 30 eWON COSY 131 | G 022

Chapter
COSY P Address & Access to the Web
Configuration
Start the eBuddy utility on your PC
n the home page,
select Set P Address
Fill in the Serial Number of your COSY
or click on Browse and select it.
The Serial Number of the COSY is on
its label, see in 3.1.Label
Click Next
Enter a new LAN P address
and Subnet Mask.
Click Next
Page 20 / 30 eWON COSY 131 | G 022
Other manuals for Cosy 131 Cellular 3G+
2
This manual suits for next models
2
Table of contents
Other eWON Network Router manuals