oserio FTG-588 User manual

User Manual
FTG-588 Body Composion & Cardio Scale
Please keep the instrucon manual at hand all the me
for future reference.

1
Explanaon of the Graphic Symbols
SN-135-00001
Designaon of the serial number of every
product,applied at the product.
(Number as an example)
“Please note the accompanying documents“
or “Observe operang instrucons”
Idenficaon of manufacturer of medical
product including address
Charder Electronic Co., Ltd.
No.103, Guozhong Rd.,
Dali Dist.,Taichung City,
412 Taiwan (R.O.C.)
“Electro-medical appliance“ with
aachment for type BF
Dispose of old appliances separately from
your household waste!Instead, take them to
communal collecon points.
Carefully read this operaon manual before
setup and commissioning, even if you are
already familiar with oserio scales.

Warning
2
Charder Electronic Co., Ltd.
No.103, Guozhong Rd., Dali Dist., Taichung City 41262 Taiwan
Tel: +886-4-2406 3766
Fax: +886-4-2406 5612
Website: www.oserio.com E-mail: [email protected]
Copyright© Charder Electronic Co., Ltd. All rights reserved.
This user manual is protected by internaonal copyright law.
All content is licensed, and usage is subject to wrien authorizaon
from Charder Electronic Co., Ltd. (hereinaer Charder) Charder
is not liable for any damage caused by a failure to adhere to
requirements stated in this manual.
Charder reserves the right to correct misprints in the manual
without prior noce, and modify the exterior of the product for
quality purposes without customer consent.
During measurement, this product will send a low level impercepble
electrical current throughout the body. Individuals with implanted
medical devices, such as:
1. Pacemakers
2. Electronic lungs and other electronic medical life support equipment
3. ECG products
must not use this product, as the electric current
may affect the implanted device.
This product is not a medical device and should not
be used for diagnosis or treatment.
Copyright Noce

Table of Contents
Product Descripon
2.1 Overview
2.2 Inserng Baeries
7
8
How to Use
3.1 Self-calibraon
3.2 Conducng measurement
3.3 Measurement Results Explained
3.4 About Bioelectrical Impedance Measurement
9
9
11
14
Caring for your product
4.1 Use & Storage
4.2 Service and maintenance
16
16
Troubleshoong
5.1 Error Messages 17
Product Specificaons
6.1 Product Informaon
6.2 EMC Guidance and Manufacturer's Declaraon
18
19
Before Use
1.1 General Informaon
1.2 Connecng to o'Care app on smartphone
4
6
3

Before Use
1.1 General Informaon
4
Thank you for choosing this oserio product. Before use, please read this
user manual carefully, and keep it in a safe place for reference.
It contains important instrucons regarding proper usage.
Intended Use
This product is intended to measure the weight and bioelectrical
impedance of children or adults who can stand unassisted,
using input data to calculate subject's body composion.
General Handling
Product should be placed on stable, flat, solid, non-slippery surface.
Place the product in an area free from direct sunlight, heang
equipment,high humidity, or extreme temperature change.
Never submerge in water.
Usage on so surfaces (ex: carpet) may result in inaccurate results.

5
Before Use
1.1 General Informaon
During measurement, this machine will send a low level
impercepble electrical current throughout the body.
Individuals with implanted medical products, such as:
Pacemakers.
ECG products.
Electronic lungs and other electronic medical life support equipment.
should not use this product, as the electric current may affect
the implanted product.
Warning
Disposal
All baeries contain toxic compounds; baeries should be disposed
of via designated competent organizaons. Baeries should not be
incinerated.
This product is not to be treated as regular household waste, but
should be taken to a designated collecon points for electronics.
Further informaon should be provided by local waste disposal
authories.
Usage of Results
The FTG-588 is not a diagnosc product.
BIA results are calculated based on impedance values validated
with representave populaon studies and stascal analysis.
As such, the technique is best suited for tracking progress for an
individual over a period of me, or for categorizing large groups of
people, rather than used as a one-me analysis. Accuracy of results
is highly dependent on proper measurement procedure.
Please follow instrucons carefully for best results.
Pregnant women should use the weight and heart rate funcon only.
Body composion calculaons may be of limited accuracy.

Before Use
1.2 Connecng to o'Care app on smartphone
6
The FTG-588 is designed to be used with the o'Care smartphone app,
making it easy to track body composion results for as many users as
needed.
An iOS or Android device (with operaonal Bluetooth and Wi-Fi) is
required to download the o'Care app, and retrieve measurement
results from the product.
Aer installaon, product and app is ready for use. Create a user profile
as instructed by o'Care. The FTG-588 will automacally pair and sync
with your smartphone if the o'Care app is open during measurement.
Google Play
(Android Devices)
App Store
(iOS Devices)

7
Product Descripon
2.1 Overview
LED screen
Measurement plaorm
Feet
Baery cover

Product Descripon
1.2 Inserng Baeries
8
Ensure baeries are inserted in correct orientaon. If baeries are
inserted incorrectly, product will not funcon. If product will not be
used for a long period of me (> 3 months), remove the baeries
before storage.
Insert 3 AAA baeries
Replace baery cover
Open baery housing cover
Remove baery cover
1.
2.
3.
NOTE:

9
How to Use
3.1 Self-calibraon
3.2 Conducng measurement
The product may require a quick self-calibraon before being used for the
first me to ensure accuracy.
1. Place product on stable, flat, solid, non-slippery surface (no carpet).
2. Step on measurement plaorm. Weight will be displayed on screen.
3. Step off from measurement plaorm. Aer product turns off
automacally aer a short period of me, self-calibraon is complete.
Weight measurement in process.
Remove shoes and socks, and ensure soles
of feet are clean. Stand on product for
measurement.
Try to stand as sll as possible.
Place product on stable, flat, solid, non-slippery
surface (no carpet). To ensure accuracy,
we recommend performing self-calibraon
if product is moved.Open o'care app on
smartphone and log-in. Results will be
automacally transferred aer measurement,
so it is important to select the correct user.
STEP ON
1.
2.
3.

How to Use
3.2 Conducng measurement
10
Heart rate measurement in process.
Impedance measurement in process.
Aer measurement compleon, screen will
alternate display of weight and heart rate.
Product will send results to smartphone.
(please open o'Care app prior to measurement,
to allow product to automacally pair and sync)
Aer result transfer is complete, product will
automacally shut down.
1. If o'care app is not open on smartphone, results will not be transferred.
Product will automacally shut down 30 seconds aer compleon
of heart rate measurement.
2. Ensure that Bluetooth is enabled on smartphone.
3. If you only need to measure weight and heart rate, smartphone
transfer is not needed.
4.
5.
6.
Syncing measurement results

11
How to Use
3.3 Measurement Results Explained
Body fat percentage is useful in determining the specific cause of weight
loss or gain. Average percentages differ according to specified groups and
categories, most significantly by gender. Although no universally accepted
published ranges or cut-off points for body fat percentage currently exist,
it is sll an important value in assessing change in body composion and
health.
Body Fat Percentage
Basal metabolic rate is the minimum required energy to sustain the body's
vital funcons while at rest. These funcons include breathing, blood
circulaon, regulaon of body temperature, cell growth, brain funcon,
and nerve funcon. BMR tends to decrease with age or reducon in weight,
and is posively correlated with increase in muscle.
Basal Metabolic Rate (BMR)
BMI is a commonly used index by the World Health Organizaon (WHO), ulizing
height and weight to classify underweight, normal, over, and obesity in adults.
Body Mass Index (BMI)
Category BMI (kg/m2) Risk of obesity-related disease
Under
Normal
Over
Obese I
Obese II
Obese III
< 18.5
18.5-24.9
24.9-29.9
30.0-34.9
35.0-39.9
> 40
Low
Average
Slightly Increased
Increased
High
Very High
Abdominal fat can be divided into visceral and subcutaneous fat. Visceral
obesity can occur even if your weight or BMI is within normal standards.
It's possible to be thin on the outside, but fat on the inside . Visceral fat
level has high correlaon with risk of a variety of obesity-related diseases.
Visceral Fat Level
1
Dudeja V, Misra A, Pandey RM, Devina G, Kumar G, Vikram NK. BMI does not accurately preduct
overweight in Asian Indians in northern India. Br J Nutr. 2001;86:105-112
1
1

How to Use
3.3 Measurement Results Explained
12
Your calculated metabolism is compared to average BMR for your age and gender group.
Body Age
Higher bone mineral content may be an indicator of higher bone density.
Bone Mineral Mass
Increase in muscle mass increases BMR, which in turn allows the body to
burn calories more quickly.
Muscle Mass
Askew EW Present Knowledge in Nutrion (7th ed) 1996, p.98-107
Lesser GT, Markofsky J. Body water compartments with human aging using fat-free mass
as the reference standard. 1979. Am J Physiol, 236, p.R215-R220.
Cameron CW, Guo SS, Zeller CM, Reo NV, Siervogel RM. Total body water for white adults 18
to 64 years of age: The Fels Longitudinal Study. 1999. Kidney Internaonalk Vol.56 Issue 1, p.244-252
Moore FD, Haley HB, Bering EA, Brooks L, Edelman I. Further observaons on total body water.
Changes of body composion in disease. 1952. Surg Gynecol Obstet, 95, p.155-180
2
3
4
5
Body water refers to the water contained in the ssues, blood, bones, and
elsewhere. Body water in a healthy (non-obese) adult can fluctuate by
roughly 5% daily, influenced by physiological acvity and consumpon of
food and drink . Due to larger size and muscle mass, healthy adult men
tend to have more body water than women (on average) .
Body Water
Typically, children have a higher percentage of body water than adults,
and body water levels reportedly decrease further around middle age as
part of the aging process . In addion, various diseases can affect body
water percentage .Therefore, BIA esmaons should be used with
parcular cauon if subject's body water differs significantly from
the representave populaons used to formulate BIA algorithms.
2
2
4
5
3

13
How to Use
3.3 Measurement Results Explained
Skeletal muscle mass can be developed acvely through proper nutrion
and training, thus making this value an important indicator for evaluaon
of fitness progression.
Skeletal Muscle
The overall health score is calculated using body composion readings.
It works on a percentage basis, with 100 being the highest possible
score aainable.
Health Score
The product uses patented heart rate measurement technology to
measure your heart rate as part of the weighing process.
Heart Rate
The total amount of protein in the body.
Protein
While a high body fat percentage can increase the risk of obesity-related
diseases, a high muscle percentage is not inherently associated with health
risks.
Muscle Percentage

How to Use
3.4 About Bioelectrical Impedance Measurement
14
The FTG-588 uses Bioelectrical Impedance Analysis (BIA)
to calculate body composion. At its core, BIA operates
by treang the human body as an electrical conductor with
in an alternang current circuit, from which the alternang
current resistance and impedance is measured.
The measurement current flows from one lower limb through the lower
abdomen and then into the other lower limb, and the bioelectrical
impedance is measured. For reference, the impedance measurement
methods for the legs are shown in the diagram.
Impedance
Using a combinaon of exisng populaon data and in-house research,
body composion analysis formulas can calculate results based on the
Impedance, Height, Gender, Age, and Weight of the subject.
These algorithms are formulated with reference to "gold standard"
measurements such as Dual-Energy X-ray Absorpometry (DXA) to
confirm viability and accuracy.
1.Do not exercise or perform strenuous physical tasks before measurement.
Strenuous physical tasks and exercise can result in a temporary change in
body composion measurements. As BIA analyzes electrical impedance in
the body, acvies that might affect impedance (e.g. increased
perspiraon, dehydraon, blood circulaon) may affect measurement
accuracy.
Kushner RF, Clinical characteriscs influencing bioelectrical impedance analysis measurements, 1996
6
L
A
Before measurement, please take note of the following:
For best results, body composion analysis via BIA should be conducted
under specific condions. Inconsistent measuring condions will affect the
accuracy and validity of BIA results, and interpretaon of body composion.
The informaon below regarding the effect of various factors on measurement
results is largely sourced from related research by Kushner et al .
Measurement Rules
6

15
How to Use
3.4 About Bioelectrical Impedance Measurement
2. Affect of food and drink on measurement results.
Ingeson of food and drink can affect impedance and weight, and thus
analysis results. This change generally lasts 2-5 hours aer each meal.
For most accurate results, BIA measurements should ideally be
conducted in a fasng state (e.g. before breakfast) .
7. Measure height accurately.
Inaccurate height input will affect esmaon of body composion.
8. Perform the measurement in the morning.
As a general rule, BIA measurements should be performed in the morning to
minimize the influence of acvity throughout the day on measurements .
3. Do not shower or bathe directly before measurement.
Perspiraon can result in a temporary change in body composion
measurements, as the accuracy of BIA depends largely upon interpretaon
of measured impedance values, which are affected greatly by hydraon levels.
4. Perform the measurement under normal temperature condions (24-28°C)
Extreme temperatures (both hot and cold) can result in temporary
physiological changes. For example, excessive sweang due to heat
can cause increased impedance measurements, resulng in a higher fat
calculaon. For best results, measurements should be conducted in an
environment between 24-28°C.
5. Remove shoes and socks before measurement.
Shoes and socks will interfere with the electric current,
making measurement inaccurate or in some cases, impossible.
6. Avoid physical contact with other people during measurement.
Because BIA measures the impedance encountered as the electric
current travels through the subject's body, if another individual is touching
the subject, the electric current may pass through the other individual,
causing inaccuracy in measurement results.
R Gallagher, M & Walker, Karen & O'Dea, K. The influence of a breakfast meal on the assessment of
body composion using bioelectrical impedance. European journal of clinical nutrion. 52. 94-7.
7
Oshima Y & Shiga T. Within-day variability of whole-body and segmental bioelectrical impedance
in a standing posion, European Journal of Clinical Nutrion 2006, 60, 938-941
8
7
8

Caring for your product
4.1 Use & Storage
4.2 Service and maintenance
16
The FTG-588 does not contain user-maintained parts. Service and
maintenance not described in this user manual should be performed
only by authorized technicians.
1. Product should be stored in clean, cool, dry locaon when not in use,
away from direct sunlight and extreme temperatures.
2. This product is not a toy. Children should not be allowed to play with it.
3. Avoid corrosive liquids and materials. Do not use detergents or cleaners
to clean the product. This may damage the coang protecng the
electrodes used for body composion measurement.
4. Wipe the plaorm and display using clean so cloth. Avoid rough,
scky cloth, to prevent scratching the measurement plaorm and
screen panels.

17
Troubleshoong
5.1 Error Messages
Low baery warning
Replace baeries
Overload or unstable weight
Total load exceeds product's maximum
capacity. Stay sll and avoid movement
during measurement.
Data transfer error
Data sent from smartphone to product
resulted in error. Try measurement again
Data transfer error
Data sent from product to smartphone
resulted in error. Try measurement again
Heart Rate measurement error
Stay sll and avoid movement during
heart rate measurement.

Product Specificaons
6.1 Product Informaon
18
Temperature: 5 C~35 C
Relave Humidity: 30%~85%
Weight
Body Mass Index (BMI)
Body Fat Percentage
Visceral Fat Level (0~50)
Basal Metabolic Rate
Body Age
Body Water
Bone Mineral Mass
Muscle Percentage
Muscle Mass
Skeletal Muscle Percentage
Protein
Health Score
Heart Rate
Model
Baery Product Weight
FTG-588 Body Composion & Cardio Scale
3 AAA baeries 1.6kg
Dimensions Product: 290(W) x 300(D) x 25(H) mm
Screen: 66(W) x 32(D)
Operaon
Environment
Storage
Environment
Temperature: -20 C~60 C
Relave Humidity: 10%~95%
Measurement
Sensors
Measurement
Output
(displayed on
o'Care app)
4 weight sensors
Bioelectrical Impedance Analysis
Capacity /
Graduaon
5~180 kg x 0.1 kg
11~396 lb x 0.2 lb

The FTG-588 Body Composion & Cardio Scale is intended for use in the
electromagnec environment specified below. The customer or the user
of the product should assure that it is used in such an environment.
The product uses RF
energy only for its internal
funcon. Therefore, its RF
emissions are very low and
are not likely to cause any
interference in nearby
electronic equipment.
Group 1 RF emissions CISPR 11
The product is suitable for
use in all establishments,
including domesc
establishments and those
directly connected to the
public low-voltage power
supply network that
supplies buildings used for
domesc purposes.
Class BRF emissions CISPR 11
Class A Harmonic emissions IEC
61000-3-2
Compliance Voltage fluctuaons/flicker
emissions IEC 61000-3-3
19
Product Specificaons
6.2 EMC Guidance and Manufacturer's Declaraon
Guidance and manufacturer’s
declaraon-electromagnec emissions
Emission test Compliance Electromagnec
environment-guidance
The FTG-588 Body Composion & Cardio Scale is intended for use in the
electromagnec environment specified below. The customer or the user of the
product should assure that it is used in such an environment.
Guidance and manufacturer’s declaraon-electromagnec
emissions
Table of contents
Other oserio Scale manuals

oserio
oserio FEP-103 SERIES User manual

oserio
oserio MEG-213 User manual

oserio
oserio BBP-703 Series User manual

oserio
oserio BHG-208 User manual

oserio
oserio MEP-263 SERIES User manual

oserio
oserio FEG-113 Series User manual

oserio
oserio FSC-330 User manual

oserio
oserio FLG-351 Series User manual

oserio
oserio BTG-365 Series User manual

oserio
oserio MAG-605 User manual