Osram BY-M03B User manual

BY-M03B
25*4in1 matrix moving head zoom
User manual
P
le
a
se
rea
d
t
he
ins
t
r
u
ction
s ca
refu
ll
y before use

2
TABLE OF CONTENTS
1.
S
af
ety
I
nst
r
uctions
..................................................................................................... 2
2. Technical Specifications
...........................................................................................4
3. How To Control The Unit
.......................................................................................5
4. How to control unit with Artnet ................................................................................16
5
. Trouble shooting
......................................................................................................18
6.
Fixture Cleaning
.......................................................................................................19
statement
The product has well capability and intact packing when leave factory.
All of the user should comply with warning item and manual, any misuse cause
of the damages are not included in our guarantee, and also can not be
responsible for any malfunction & problem owing to ignore the manual.
1.
S
af
ety
I
nst
r
uctions
Please keep this User Guide for future consultation. If you sell the unit to another user,
be sure that they also receive this instruction booklet.
Unpack and check carefully there is no transportation damage before using the
unit.
Before operating, ensure that the voltage and frequency of power
supply match the power requirements of the unit.
It’s important to ground the yellow/green conductor to earth in order to
avoid electric shock.
The unit is for indoor use only. Use only in a dry location.
The unit must be installed in a location with adequate ventilation, at
least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.
Disconnect main power before replacement or servicing.
Make sure there are no flammable materials close to the unit while operating as it is
fire hazard.
Use safety cable when fixes this unit. DO NOT handle the unit by taking its head only,
but always by taking its base.
Maximum ambient temperature is Ta: 40℃. DO NOT operate it where the

3
temperature is higher than this Unit surface temperature may reach up to 85℃. DO
NOT touch the housing bare-hand during its operation. Turn off the power and allow
about 15 minutes for the unit to cool down before replacing or serving.
In the event of serious operating problem, stop using the unit immediately.Never
try to repair the unit by yourself. Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest authorized technical
assistance center. Always use the same type spare parts.
DO NOT touch any wire during operation as high voltage might be causing electric
shock.
Warning:
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain
or moisture.
DO NOT open the unit within five minutes after switching off.
The housing, the lenses, or the ultraviolet filter must be replaced if
they are visibly damaged.
Caution:
There are no user serviceable parts inside the unit. DO NOT open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact your nearest dealer.
Installation:
The unit should be mounted via its screw holes on the bracket. Always ensure that the
unit is firmly fixed to avoid vibration and slipping while operating. And
make sure that the structure to which you are attaching the unit is secure and is able
to support a weight of 10 times of the unit’s weight. Also always use a safety cable that
can hold 12 times of the weight of the unit when installing the fixture.
The equipment must be fixed by professionals. And it must be fixed at a place where is
out of the touch of people and has no one pass by or under it.

4
2. Technical Specifications
Light Sources: 25x 4in1 RGBW LED
LENS Beam Angle: 6.5-60°
Power Consumption: 484W
Power Voltage: AC 100-240V, 50/60Hz
Dimension: 40*31*47CM
Net Weight: 14Kgs
Control
Control Modes: DMX512,Artnet control
DMX mode :13/ 24/88/113 Channels
Artnet mode : 75/100 channels
Pan/Tilt
Pan/Tilt: infinite rotation
Pan/Tilt Resolution: 8/16 bit
Construction
Display: 180°reversible LCD Display
Data In/Out socket: 3-pin & 5-pin XLR sockets
Powercon in
Protection Rating: IP20
Features
Dimmer:0~100% smooth dimming ; Two dimmers model in optional( delay or
without delay)
Outstanding color macro effect
Fast,quiet operation and flicker free
Led temperature protection & Speed of fan run automatic based on the temperature
of the head.
Single led control, zoom effect, Artnet control , infinite Pan and tilt rotation.

5
3. Lux Date
4. How To Control The Unit
Th
e
D
M
X512 is
w
id
ely
used
in
intellig
ent
ligh
ti
ng
co
n
tr
ol,with a DMX 512
controller.connect several lights together,dmx in and dmx out,
3
p
in
XLR
co
nn
ectors
:
Pin
1:
G
ND
,
Pin
2:
Nega
tive
s
ig
n
a
l
(-),
Pin
3:
P
o
s
itive
s
i
gna
l
(+)

6
Display:
MENU To select the programming functions
DOWN To go backward in the selected functions
uP To go forward in the selected functions
ENTER To confirm the selected functions
Set DMX
Address Code
1 Press "Menu" to "Set DMX Address",and press"ENTER" keys to enter into
2 Show "Set DMX Address DMX Address:001",Press the "UP and DOWN"
keys to amended
3 Press "ENTER"keys to save and Exit,Press the"MENU"Keys does not save and Exit
4 . Press ‘left’ and ‘right’ to reverse the display
Menu
Address
Address001~XXX
Set DMX
Address

7
Dmx Value
ALL…
Display DMX
Value
LED
Temperature
XXXC/F
Fixture
Hours
Current Hours
Total Hours
Last Hours
Ethernet IP
X.X.X.X
X.X.X.X
IP Address
IP Mark
Software
Version
VX.X.X…
Software
Version
Option Config
Pan Tilt
Pan Reverse
Tilt Reverse
Pan-Degree
Encoder
Pan Tilt Speed
ON/OFF
ON/OFF
540/360
ON/ OFF
Speed 1~ 4
Service
Password
XXXX
Password
Code=123
RDM PID
0-131071
RDM PID
IP Address
Manual Set
Art-Net On IP2
Art-Net On IP10
IP Mask
X.X.X.X
IP Mask
Universe
·OFF,1-255
Art Universe
LED Address
1-512
LED Address
Source Select
DMX Only
Art-Net
DMX&Art-Net
Signal Select
DMX、Art、
DMX and Art
Display
Shutoff
2-60m
Reverse
ON/OFF
Lock On
ON/OFF

8
Temperature
C/F
Celsius
Fahrenheit
Reset Default
ON/OFF
Reset To
Factory Default
Manual Control
Manual
PAN
…...
White All
Password=XXX
…
White All =XXX
Test Channel
PAN
…
White All
Calibration
Password
PAN
TILT
ZOOM
Rotation
Password=XXX
PAN=XXX
PAN=XXX
ZOOM=XXX
Rotation =XXX
Reset
Reset ALL
Reset All Motors
DMX Mode Set
Standard
Shape RGB
Shape
RGBW
DMX&Net
RGB
DMX&Net
RGBW
Standard Mode
Shape Mode With RGB
Shape Mode With RGBW
Shape Mode With RGB While DMX&Art-Net select
Shape Mode With RGBW While DMX&Art-Net select
1.When DMX mode is DMX&NetRGB or DMX&NetRGBW, DMX&Artnet under
Option Config /Source select should be selected. LED1-LED25 (RGBW)
control by Artnet, and the rest controlled by DMX.
2. When DMX Mode set is DMX&NET RGB or DMX&NET RGBW. DMX&Artnet
under source select was choosed. LED R/G/B/W will be controlled by the
Artnet.LED address means from which channel begin to control. LED
address=10, means control Red of first LED from channel 10 , channel 11
control Green of first LED, channel 12 control control Blue of first LED,channel

9
12 control White of first LED, channel 14 control RED of second LED.
DMX channel´s functions and values (24/88/113DMX channels):
Mode/Channel
Value
Function
Standard
Sha
pe
RG
B
Shap
e
RGB
W
DMX
&Net
RGB
DMX&
Net
RGBW
1
1
1
control by DMX
1
1
PAN Movement 8bit :
0-255
Pan Movement
2
2
2
2
2
Pan Fine 16bit
0-255
Fine control of Pan movement
3
3
3
3
3
TILT Movement 8bit :
0-255
Tilt Movement
4
4
4
4
4
Tilt Fine 16bit
0-255
Fine control of Tilt movement
5
5
5
5
5
Speed Pan/Tilt movement:
0-225
max to min speed
226-255
no function
6
6
6
6
6
PAN Ritation :
0-127
No function
128-189
PAN Rotation Forward min to max speed
190-193
PAN Rotation Stop
194-255
PAN Rotation Reverse min to max speed
7
7
7
7
7
TILT Ritation :
0-127
No function
128-189
TILT Rotation Forward min to max speed
190-193
TILT Rotation Stop
194-255
TILT Rotation Reverse min to max speed
8
8
8
10
10
Zoom :
0-255
Zoom adjustment

10
9
9
9
9
9
STORBE
0-31
Led trun off
32-63
Led turn on
64-95
Strobe effect slow to fast
96-127
Led turn on
128-159
Pulse-effect in sequences
160-191
Led turn on
192-223
Random strobe effect slow to fast
224-255
Led turn on
10
10
10
10
10
Dimmer intensity:
0-255
Intensity 0 to 100%
11
11
11
11
11
Dimmer Mode:
0-20
Mode1
21-40
Mode2
41-60
Mode3
61-80
Mode4
81-100
Mode5
100-255
Mode1
12
12
12
12
12
LED Gamma:
0-59
Gamma 2.0
60-119
Gamma 2.2
120-179
Gamma 2.4
180-239
Gamma 2.6
240-255
Gamma 2.8
13
Rainbow:
0-7
No function
8-39
RED to YELLOW
40-71
YELLOW to GREEN
72-103
GREEN to CYAN
104-135
CYAN to BLUE
136-167
BLUE to MAGENTA

11
168-199
MAGENTA to RED
200-231
RED to WHITE
232-255
Crossfading colours from slow to fast
14
Color Presets:
0-4
No function
5--9
White1
10--14
White2
15-19
White3
20-24
White4
25-29
White5
30-34
White6
35-39
Color1
40-44
Color2
45-49
Color3
50-54
Color4
55-59
Color5
60-64
Color6
65-69
Color7
70-74
Color8
75-79
Color9
80-84
Color10
85-89
Color11
90-94
Color12
95-99
Color13
100-104
Color14
105-109
Color15
110-114
Color16
115-119
Color17
120-124
Color18
125-129
Color19
130-134
Color20

12
135-139
Color21
140-144
Color22
145-149
Color23
150-154
Color24
155-159
Color25
160-164
Color26
165-169
Color27
170-255
Reserved
15
Color Presets Dimmer:
0-255
Dimmer 100 to 0%
16
Chase Patterns:
0-5
No function
6-10
Number'0'
11-15
Number'1'
16-20
Number'2'
21-25
Number'3'
26-30
Number'4'
31-35
Number'5'
36-40
Number'6'
41-45
Number'7'
46-50
Number'8'
51-55
Number'9'
56-60
A
61-65
B
66-70
C
71-75
D
76-80
E
81-85
F
85-90
G
91-95
H
96-100
I

13
101-105
J
106-110
K
111-115
L
116-120
M
121-125
N
126-130
O
131-135
P
136-140
Q
141-145
R
146-150
S
151-155
T
155-160
U
161-165
V
166-170
W
171-175
X
176-180
Y
181-185
Z
186-190
0'-'9'
191-195
A'-'Z'
196-200
0'-'Z'
201-205
Patter function1
206-210
Patter function2
211-215
Patter function3
216-220
Patter function4
221-225
Patter function5
226-230
Patter function6
231-235
Patter function7
236-240
Patter function8
241-245
Patter function9
246-250
Patter function10
251-255
Patter function11

14
17
Chase Patterns Direction:
0-49
↑Chase Up
50-99
←Chase Left
100-149
↓Chase Down
150-255
→Chase Right
18
Chase Speed:
0-125
Fast to Slow Backward
126-130
Stop(Speed=0)
131-255
Slow to Fast Forward
19
Chase Fade:
0-255
Fade Chase
20
Red LED -all arrays :
0-255
Red ( 0-Black , 255-100% Red )
21
Green LED-all arrays :
0-255
Green ( 0-Black , 255-100% Green )
22
Blue LED -all arrays :
0-255
Blue ( 0-Black , 255-100% Blue )
23
White LED -all arrays :
0-255
White ( 0-Black , 255-100% White )
24
13
13
13
13
Lamp on/off, reset, internal programs:
0-79
Normal
80-99
All motor reset
100-255
Normal
14
14
control by ART_NET
1
1
Red LED -array 1 :
0-255
Red ( 0-Black , 255-100% Red )
15
15
2
2
Green LED-array 1 :
0-255
Green ( 0-Black , 255-100% Green )
16
16
3
3
Blue LED -array 1 :
0-255
Blue ( 0-Black , 255-100% Blue )
17
4
White LED -array 1 :

15
0-255
White ( 0-Black , 255-100% White )
17
18
4
5
Red LED -array 2 :
0-255
Red ( 0-Black , 255-100% Red )
18
19
5
6
Green LED-array 2 :
0-255
Green ( 0-Black , 255-100% Green )
19
20
6
7
Blue LED -array 2 :
0-255
Blue ( 0-Black , 255-100% Blue )
21
8
White LED -array 2 :
0-255
White ( 0-Black , 255-100% White )
20
22
7
9
Red LED -array 3 :
0-255
Red ( 0-Black , 255-100% Red )
21
23
8
10
Green LED-array 3 :
0-255
Green ( 0-Black , 255-100% Green )
22
24
9
11
Blue LED -array 3 :
0-255
Blue ( 0-Black , 255-100% Blue )
25
12
White LED -array 3:
0-255
White ( 0-Black , 255-100% White )
23
26
10
13
Red LED -array 4 :
0-255
Red ( 0-Black , 255-100% Red )
24
27
11
14
Green LED-array 4 :
0-255
Green ( 0-Black , 255-100% Green )
25
28
12
15
Blue LED -array 4 :
0-255
Blue ( 0-Black , 255-100% Blue )
29
16
White LED -array 4 :
0-255
White ( 0-Black , 255-100% White )
26
30
13
17
Red LED -array 5 :
0-255
Red ( 0-Black , 255-100% Red )
27
31
14
18
Green LED-array 5 :
0-255
Green ( 0-Black , 255-100% Green )
28
32
15
19
Blue LED -array 5 :
0-255
Blue ( 0-Black , 255-100% Blue )

16
33
20
White LED -array 5 :
0-255
White ( 0-Black , 255-100% White )
29
34
16
21
Red LED -array 6 :
0-255
Red ( 0-Black , 255-100% Red )
30
35
17
22
Green LED-array 6 :
0-255
Green ( 0-Black , 255-100% Green )
31
36
18
23
Blue LED -array 6 :
0-255
Blue ( 0-Black , 255-100% Blue )
37
24
White LED -array 6:
0-255
White ( 0-Black , 255-100% White )
32
38
19
25
Red LED -array 7 :
0-255
Red ( 0-Black , 255-100% Red )
33
39
20
26
Green LED-array 7 :
0-255
Green ( 0-Black , 255-100% Green )
34
40
21
27
Blue LED -array 7 :
0-255
Blue ( 0-Black , 255-100% Blue )
41
28
White LED -array 7:
0-255
White ( 0-Black , 255-100% White )
86
110
73
97
Red LED -array 25:
0-255
Red ( 0-Black , 255-100% Red )
87
111
74
98
Green LED-array 25 :
0-255
Green ( 0-Black , 255-100% Green )
88
112
75
99
Blue LED -array 25 :
0-255
Blue ( 0-Black , 255-100% Blue )
113
100
White LED -array 25:
0-255
White ( 0-Black , 255-100% White )
When channel mode is DMX&ARTNET RGB or DMX&ARTNET RGBW. The
yellow parts are (RGBW of LED1-LED25) channels controlled by Artnet, rest
channels controlled by DMX.

17
5.How to control Unit with ArtNet
1. Setting IP Address, choose
Manual set
to manual input IP address, better choose
ON IP2
or
ON IP10
auto set.
2. IP Mask ,
input
255.0.0.0
3. Universe
choose
OFF
or
1
4. Source select ,input signal selection, there are three options:
DMX only →input signal is DMX
Art-Net →input Art-Net signal
DMX & Art-Net →Simultaneous input DMX & Art-Net signal
Notice:
If Select DMX only or Art-Net, Channels mode only can choose Standard or
Shape RGB or Shape RGBW. Then only have DMX or Art-Net signal separately
control Pan/Tilt, Dimmer and RGBW, etc.
If select DMX & ArtNet , means simultaneously controlled by DMX and Art-Net,
and Art-Net only control RGBW Channels, DMX control others channels, meantime,
CH MODE only can choose DMX & Artnet RGB or
DMX & Net RGBW
.
For example,if now choose DMX & Artnet RGB CH Mode, then CH 1 - CH13 are
controlled by DMX, RGB matrix controlled by Art-Net.
↓ ↓
→
DMX Controller
Pan/Tilt,dimmer
Strobe etc.
Art-Net controller
R/G/B/W image data
DMX only
Art-Net
Standard
Shape RGB
Shape RGBW
Signal input
CH MODE
DMX & Art-Net
DMX & Net RGB
DMX&Net RGBW

18
→
5. When fixtures signal input select Art-Net or DMX & Art-Net, means selected Art-Net
controller to control fixtures. But Art-Net controller also need set the same IP address, IP
MARK as fixtures.
Setting via menu
Information
→
Ethernet IP
→select search fixture’s
IP Address
,
IP MARK
information.
6. Trouble shooting
F
ollo
w
ing
a
r
e
a
few
c
o
mm
on
p
r
oble
m
s
th
a
t
m
a
y occu
r
d
uring
ope
r
a
tion
. He
r
e
a
r
e
s
o
m
e
s
ug
g
es
tion
s
fo
r
ea
s
y
tr
ou
b
leshooting
:
A.
The
un
it
does
no
t
work
, no
li
ght
a
n
d
t
he
f
a
n
d
o
es
no
t
w
o
r
k
1.
Ch
eck
th
e
c
on
nect
ion of
p
owe
r
a
nd
m
a
in
fu
s
e
.
2.
M
eas
ure
th
e
m
a
ins
volt
a
g
e
on
th
e
m
a
i
n
co
nn
e
ct
o
r
.
3.
Ch
eck
th
e
pow
er
on
LED
.
B.
N
o
t
responding
t
o
D
MX
c
on
t
ro
ll
er
1.
D
M
X
LED
s
h
ou
ld
b
e
on.
If
no
t,
che
ck
D
M
X
co
n
nectors,
ca
b
l
es
to
s
ee
if
link
p
r
ope
r
ly
.
2.
If th
e
D
M
X
LE
D
i
s
on
a
nd no
r
espons
e
t
o
th
e
c
h
a
nn
el,
che
ck
th
e
a
dd
r
ess
s
etti
ng
s a
nd
D
M
X
p
ol
a
r
ity
.
3.
If
y
ou
h
a
ve
i
nter
m
ittent D
M
X
s
ig
n
a
l
p
r
oble
m
s
,
che
ck
th
e
p
ins
on
c
onn
ecto
r
s
or
on
PCB
of
th
e
u
nit
or
the
p
r
ev
iou
s
on
e.
4.
Tr
y
to
us
e
a
no
th
er
D
M
X
co
ntroller
.
5.
Ch
eck
if
th
e
D
M
X
ca
b
le
s
r
un
ne
a
r
or run
a
lon
g
s
id
e
t
o
h
ig
h
volta
g
e
c
a
b
les
th
a
t
m
a
y
c
a
us
e
d
a
m
a
g
e
or
in
terfer
ence
to D
M
X
inter
face
circui
t.
C
. One
of
the
cha
nn
el
s
is
no
t
w
o
r
k
ing
w
el
l
1.
Th
e
s
tep
p
er
moto
r
m
ig
h
t
b
e
dam
a
g
ed
or
the
c
a
b
le
c
on
nect
ed
to th
e PCB
is
b
r
oken.
2.
Th
e
m
oto
r
’
s
d
r
ive
IC
on
th
e
PCB
m
ig
h
t
b
e
o
ut
of
co
ndition.

19
7. Fixture Cleaning
Th
e
clean
ing
o
f
inter
na
l
a
nd
ex
ter
na
l
optica
l
lens
es
a
nd/or
m
ir
r
ors
m
u
s
t
b
e
c
a
rr
ied
ou
t
p
eriodica
lly to optim
iz
e
ligh
t
ou
tput
.
Cle
a
nin
g
f
r
eq
uency
d
e
p
end
s
on
t
h
e
environm
ent
in
w
hich
t
h
e
f
ixture
ope
r
a
tes
:
d
a
m
p
,
s
m
oky o
r
p
a
r
tic
ula
r
ly
d
ir
ty
s
urr
ound
ing
c
a
n
c
a
us
e
g
r
eat
er acc
um
ula
tio
n
of
d
ir
t
on
th
e
u
nit’
s optics
.
Cle
a
n
with
s
oft
clo
th
u
s
ing
no
r
m
a
l
g
l
a
ss
clea
ni
ng
fluid
.
A
lw
a
y
s
d
r
y
th
e
parts
ca
r
ef
ully
.
Cle
a
n
th
e
ex
ter
na
l
optic
s
a
t
leas
t
ev
ery
20
days. Cle
a
n
th
e
in
ter
na
l
opti
cs
a
t
lea
s
t
ev
ery
30/60
days.
Table of contents
Other Osram Dj Equipment manuals

Osram
Osram KREIOS PAR162W VNSP IP 100-240V User manual

Osram
Osram Claypaky AXCOR PROFILE 600 TEATRO User manual

Osram
Osram BY-P23B User manual

Osram
Osram BY-P12 User manual

Osram
Osram ADB Stagelight LEXPERT PROFILE L User manual

Osram
Osram BY-P06 User manual

Osram
Osram Clay Paky MYTHOS User manual

Osram
Osram M51 User manual

Osram
Osram KREIOS PROFILE 80W WW User manual

Osram
Osram ARCHISHAPE 2.0 Linear User manual