Rating Label
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the
Pacic Energy, NEO 1.2 Freestanding wood heater.
This heater meets the 2015 U.S. Environmental Protection
Agency's crib wood emission limits for wood heaters sold
after May 15, 2015. Model NEO1.2: 2.9 g/hr.
Under specic test conditions this heater has been shown
to deliver heat at rates ranging from 11,700 to 22,400
Btu/hr.
SAFETY NOTICE: If this stove is not properly installed,
a house re may result. For your safety, follow the
installation instructions. Contact local building or re
ofcials about restrictions and installation inspection
requirements in you area.
Please read this entire manual before you install and use
your new room heater. Failure to follow instructions may
result in property damage, bodily injury, or even death.
EPA Certied Emissions 2.9 grams per hour
LHV Tested Efciency 1 79.6%
HHV Tested Efciency 2 73.7%
EPA BTU Output 3 11,700 to 22,400 btu/hr
Peak BTU/Hr Output 4 29,700
Maximum Wood Length 17 inches
Ideal Wood Length 16 inches
Fuel Seasoned Cord wood
1 Weighted Average Lower Heating Value (LHV) efciency as
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efciency
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required
to vaporize the water in the fuel
3 The range of BTU outputs is based on efciency using CSA
B415 Performance testing of solid-fuel-burning heating appli-
ances and burn rates from the low and high EPA tests using
Douglas Fir dimensional lumber.
4 The Peak BTU/hr is based on efciency using CSA B415
Performance testing of solid-fuel-burning heating appliances,
the Maximum one hour High burn rate from the High Burn EPA
test and the BTU content of cord wood (8600 btu/lb).
Efficiency and BTU Output
Experience will give you the right settings for proper combustion and efcient burning. Remember the correct air inlet
setting is affected by variables such as type of wood, outside temperature, chimney size and weather conditions. With
practice, you will become procient in operating your heater and will obtain the performance for which it was designed.
CERTIFIED FOR CANADA AND U.S.A. - SERIES / SÉRIE: DMODEL / MODÈLE: SUPER 27 SPECTRUM ALDERLEA T5 CLASSIC
LISTED ROOM HEATER, SOLID FUEL TYPE.
ALSO FOR USE IN MOBILE HOMES. TESTED TO/ ÉPROUVÉ SELON: CAN/ULC S627-00 / CONFORMS TO UL 1482-2011
• INSTALL AND USE IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION AND OPERATING
INSTRUCTIONS.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND
INSPECTION IN YOUR AREA.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE (USA. ONLY).
• USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECTOR.
• CAN BE CONNECTED TO A LINED MASONRY CHIMNEY SUITABLE FOR USE WITH SOLID FUELS.
• DO NOT OBSTRUCT THE SPACE BENEATH THE HEATER.
• SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED
WHEN PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.
• DO NOT PASS A CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR CEILING.
• MINIMUM CLEARANCE BETWEEN SINGLE WALL CHIMNEY CONNECTOR AND COMBUSTIBLE MATERI-
ALS-18INCHES/455MM. CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE SHIELDS, WALL
PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS.
• COMPONENTS REQUIRED FOR MOBILE HOME AND ALCOVE INSTALLATION: OUTSIDE AIR KIT.
BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO:
IN CANADA - ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
IN USA - UL-103 HT LISTED CONNECTOR AND CHIMNEY
• USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS.
• APPLIANCE MUST BE INSTALLED WITH PEDESTAL OR LEG KIT ATTACHED.
• OPTIONAL COMPONENTS - FAN KIT, FAN ELECTRICAL RATING: 115V, 60HZ, 1.0 AMP.
• CAUTION: RISK OF EXCESSIVE TEMPERATURES - KEEP ASH DUMP CLOSED DURING FIRING OF THE
HEATER. • DO NOT ROUTE POWER CORD UNDER HEATER.
• OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY.
• KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER.
• REPLACE GLASS ONLY WITH CERAMIC GLASS.
HORIZONTAL CONNECTOR NOT PERMITTED IN MOBILE HOMES
AS TESTED - PIPE SHIELD MAY BE REQUIRED BY LOCAL AUTHORITIES.
* ALCOVE SIZE : DEPTH - 3 FT. / .91 M MAX., HEIGHT 7 FT. / 2.1 M MIN., WIDTH 4 FT. / 1.2 M MIN.
COMBUSTIBLE FLOOR MUST BE PROTECTED BY A CONTINUOUS NON-COMBUSTIBLE MATERIAL EX-
TENDED TO THE FRONT, SIDES AND BACK AS INDICATED.
• THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. - CONSULT
THE OWNER’S MANUAL FOR FURTHER INFORMATION. • IT IS AGAINST FEDERAL REGULATIONS TO
OPERATE THIS WOOD HEATER IN A MANNER INCONSISTANT WITH THE OPERATING INSTRUCTIONS IN
THE OWNER’S MANUAL
WN#16408 ETL#4001507
• INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’OPÉRATION FOURNI AVEC L’APPAREIL..
• CONTACTEZ LES OFFICIELS DE LA CONSTRUCTION OU DE SERVICE D’INCENDIE POUR DES INFORMATIONS QUANT AUX
RESTRICTIONS. PERMIS D’INSTALLATION ET INSPECTIONS DANS VOTRE RÉGION.
• NE RELIEZ PAS CET APPAREIL À UN CONDUIT DE CHEMINÉE DESSERVANT DÉJÀ UN AUTRE APPAREIL (ÉTATS-UNIS SEULE-
MENT).
• UTILISEZ UN RACCORDEMENT NOIR OU CLASSÉ DE 24 MSG ET AVEC UN DIAMÈTRE D’AU MOINS 6 POUCES / 150 mm.
• PEUT ÊTRE CONNECTÉ À UNE CHEMINÉE DE MAÇONNERIE ALIGNÉE PRÊTE À L’EMPLOI AVEC DES COMBUSTIBLES SOLIDES.
• DO NOT OBSTRUCT THE SPACE BENEATH THE HEATER /
• CONSULTEZ LE CODE LOCAL DE CONSTRUCTION ET LES INSTRUCTIONS DU FABRICANT QUANT AUX PRÉCAUTIONS À
PRENDRE LORSQUE VOUS FAITES PASSER UNE CHEMINÉE À TRAVERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE MATÉ-
RIAUX COMBUSTIBLES.
• NE FAITES PAS PASSER UN RACCORDEMENT DE CHEMINÉE À TRAVERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE MATÉ-
RIAUX
• DÉGAGEMENT MINIMAL ENTRE UN RACCORDEMENT DE CHEMINÉE À UN MUR SIMPLE ET TOUT MATÉRIEL COMBUSTIBLE - 18
POUCES / 455 mm. CE DÉGAGEMENT PEUT ÊTRE RÉDUIT EN UTILISANT DES PROTECTEURS DE TUYAUX CLASSÉS, PROTEC-
TEURS DE MUR OU AUTRES MOYENS APPROUVÉS PAR LES OFFICIELS DE LA CONSTRUCTION OU DU SERVICE D’INCENDIE
DE VOTRE RÉGION.
CONNECTEUR HORIZONTAL NON PERMIS DANS MAISONS MOBILES
• L’APPARIEL DOIT COMPORTER UN ENSEMBLE POUR PIEDSTABLE OU SUR PATTES.
• PIÈCES REQUISES POUR INSTALLATION EN MAISON MOBILE OU EN ALCÔVE: NÉCESSAIRE D’APPROVI-
SIONNEMENT D’AIR EXTÉRIEUR ET L’UN DES RACCORDS SUIVANTS: EN COMBINAISON AVEC L’UN DES
SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS:
AU CANADA - LE ULC S-641 CONNECTEUR ENUMERES ET ULC-S-629 ONT ENUMERE CHEMINEE
• PIÈCES EN OPTION - NÉCESSAIRES DE SOUFFLERIE, INDICES ÉLECTRIQUES DE SOUFFLERIE: 115V, 60HZ, 1.0 AMP. LE FIL
ÉLECTRIQUE NE DOIT PAS ÊTRE PLACÉ SOUS LE POÈTE. • LE FIL ÉLECTRIQUE NE DOIT PAS ÊTRE PLACÉ SOUS LE POÊLE
• ATTENTION: RISQUE DE TEMPÉRATURES EXCESSIVES - GARDES LE TIROIR DE CENDRES FERMÉ PENDANT L’ALLUMAGE DU
POÈTE.
• OPÉREZ SEULEMENT LORSQUE LA PORTE D’ALIMENTATION EST FERMÉE. • OUVREZ SEULEMENT POUR ALIMENTER LE FEU.
• GARDEZ LES MEUBLES ET AUTRES MATÉRIAUX COMBUSTIBLES BIEN ÉLOIGNÉS DU POÊLE.
• REMPLACES LA VITRE AVEC UNIQUEMENT DE LA VITRE CÉRAMIQUE.
CONNECTEUR HORIZONTAL NON PERMIS DANS MAISONS MOBILES
TEL QUO ÉPROUVÉ UN PROTECTEUR DE TUYAU PEUT ÊTRE REQUIS PAR LES AUTORITÉS LOCALES
* DIMENSION D’ALCOVE COMBUSTIBLE: PROFONDEUR - 3 PIEDS / .91M, HAUTEUR 7 PIEDS/2.1M, LARGEUR 4 PIEDS/1.2M MINI-
MUM.
LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR UN MATÉRIEL NON-COMBUSTIBLE TOUT D’UNE PIÈCE QUI DOIT
S’ÉTENDRE DE PAR LE DEVANT, LES COTÉS ET L’ARRIÈRE TEL QU’INDIQUÉ.
CET APPRAREIL DE CHAUFFAGE AU BOIS DOIT FAIRE L’OBJETD’ENTRETIENS ET D’INSPECTIONS P
É
RIODIQUES
POUR UN FONCTIONNEMENT AD
É
QUAT. CONSULTEZ LE MANUEL D’UTILISATION POUR PLUS D’INFORMATION.
MADE IN CANADA/
FABRIQUÉ AU CANADA
J F M A M J J A S O N D
2015 2016 2017 2018 2019 2020
DATE OF MANUFACTURE/
DATE DE MANUFACTURE
SUP1-A25050.75
040615
MANUFACTURED BY/
FABRIQUÉ PAR:
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING
AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE
AND INSTRUCTIONS.//
CHAUD LORSQU’EN OPÉRATION. NE PAS TOUCHER, TENEZ LES
ENFANTS ET LES VÊTEMENTS BIEN À L’ÉCART. LE CONTACT PEUT CAUSER DES BRÛLURES
À LA PEAU. CONSULTEZ LA PLAQUE CE CONSTRUCTEUR ET LES INSTRUCTIONS.
CAUTION
DO NOT REMOVE THIS
LABEL S/N- 504
U.S. ENVIRONMENTAL PROTECTION AGENCY.
Certified to comply with 2015 PARTICULATE EMISSION STANDARDS.
Not approved for sale after May15,2020.//
Certifié conforme aux normes sur les
émissions de particules de 2015. Non approuvé pour la vente après le 15 Mai 2020.
3.4 g/hr
A.
18 in. / 455 mm 14 in. / 356 mm
B.
12 in. / 305 mm 8 in. / 200 mm
C.
11 in. / 280 mm 11 in. / 280 mm
D.
27 in. / 685 mm 23 in. / 585 mm
E.
19 in. / 485 mm 15 in. / 380 mm
F.
22 in. / 560 mm 22 in. / 560 mm
A.
14 in. / 356 mm 14 in. / 356 mm
B.
5 in. / 127 mm 5 in. / 127 mm
C.
4 in. / 102 mm 4 in. / 102 mm
D.
22.5 in. / 570 mm 22.5 in. / 570 mm
E.
11.5 in. / 292 mm 11.5 in. / 292 mm
F.
14.5 in. / 370 mm 14.5 in. / 370 mm
A.
16 in. / 405 mm 16 in. / 405 mm
B.
10 in. / 255 mm 8 in. / 200 mm
C.
N/A 8 in. / 200 mm
D.
24.5 in. / 620 mm 24.5 in. / 620 mm
E.
16.5 in. / 420 mm 14.5 in. / 370 mm
F.
N/A 18.5 in. / 470 mm
MINIMUM CLEARANCES TO
COMBUSTIBLE MATERIALS/
DÉGAGEMENTS MINIMALES AUX
MATÉRIAUX COMBUSTIBLES
RACCORD
VERTICAL CONNECTOR
RACCORD
HORIZONTAL CONNECTOR
RESIDENTIAL CLOSE CLEARANCE INSTALLATION
USING DOUBLE WALL CONNECTOR/
INSTALLATION
RÉSIDENTIELLE AVEC DÉGAGEMENT MINIMAL, UTILISANT
UN RACCORD DE MUR DOUBLE
* ALCOVE INSTALLATION
USING DOUBLE WALL
CONNECTOR/
* INSTALLATION
EN ALCÔVE UTILISANT UN
RACCORD DE MUR DOUBLE
RESIDENTIAL INSTALLATION
USING SINGLE WALL CONNECTOR/
INSTALLATION RÉSIDENTIELLE UTILISANT UN
RACCORD DE MUR SIMPLE
IN CANADA G. 18 INCHES / 455 MM
AU CANADA
H. 8 INCHES / 200 MM
I. 8 INCHES / 200 MM
IN U.S.A. G. 16 INCHES / 405 MM
AUX ÉTATS-UNIS
H. 5 INCHES / 127 MM
I. 0 INCHES / 0 MM
MOBILE
HOME INSTALLATION
USING DOUBLE WALL
CONNECTOR/
INSTALLATION
EN MAISON MOBILE UTILISANT
UN RACCORD DE MUR DOUBLE
A. SIDEWALL TO UNIT/
MUR DE CÔTE / APPAREIL
B. BACKWALL TO UNIT/
M
UR DE FOND / APPAREIL
C. CORNER TO UNIT/
COIN / APPAREIL
D. SIDEWALL TO CONNECTOR/
MUR DE CÔTE / RACCORD
E. BACKWALL TO CONNECTOR/
MUR DE FOND / RACCORD
F. CORNER TO CONNECTOR/
COIN / RACCORD
BACK I
HEATER
G
SIDE
H
FRONT
SIDE
H
COTE
COTE
DEVANT
POELE
DOS
RACCORD
VERTICAL CONNECTOR
RACCORD
HORIZONTAL CONNECTOR
ADJACENT WALL
BACK WALL
D
A
SIDE WALL
BE
ADJACENT WALL
F
C
MUR COTE
MUR ARRIERE
MUR ADJACENT
MUR ADJACENT
SUPER-SD1_100517-32 35055.201