manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Panamax
  6. •
  7. Surge Protector
  8. •
  9. Panamax MX5102 User manual

Panamax MX5102 User manual

Other manuals for MX5102

2

Other Panamax Surge Protector manuals

Panamax MAX 5300 User manual

Panamax

Panamax MAX 5300 User manual

Panamax M4T User manual

Panamax

Panamax M4T User manual

Panamax MAX 4310 User manual

Panamax

Panamax MAX 4310 User manual

Panamax MD2-RCA User manual

Panamax

Panamax MD2-RCA User manual

Panamax In-Wall Home Theater Power Management User manual

Panamax

Panamax In-Wall Home Theater Power Management User manual

Panamax ML4200 User manual

Panamax

Panamax ML4200 User manual

Panamax MR4000 User manual

Panamax

Panamax MR4000 User manual

Panamax PF Power Max-In-Wall MIW-SURGE-1G User manual

Panamax

Panamax PF Power Max-In-Wall MIW-SURGE-1G User manual

Panamax M4315-PRO User manual

Panamax

Panamax M4315-PRO User manual

Panamax MAX 5400-EX User manual

Panamax

Panamax MAX 5400-EX User manual

Panamax MOD-AT2 User manual

Panamax

Panamax MOD-AT2 User manual

Panamax MIW-VGA User manual

Panamax

Panamax MIW-VGA User manual

Panamax MIW-SURGE User manual

Panamax

Panamax MIW-SURGE User manual

Panamax MAX 5100-PM User manual

Panamax

Panamax MAX 5100-PM User manual

Panamax MX5102 User manual

Panamax

Panamax MX5102 User manual

Panamax MIW-XT User manual

Panamax

Panamax MIW-XT User manual

Panamax M8-HT User manual

Panamax

Panamax M8-HT User manual

Panamax M4300-PM User manual

Panamax

Panamax M4300-PM User manual

Panamax MIP-15LT User manual

Panamax

Panamax MIP-15LT User manual

Panamax MAX 5410 User manual

Panamax

Panamax MAX 5410 User manual

Panamax MIW-SURGE User manual

Panamax

Panamax MIW-SURGE User manual

Panamax MFP-400 User manual

Panamax

Panamax MFP-400 User manual

Panamax M4LT-EX Instruction Manual

Panamax

Panamax M4LT-EX Instruction Manual

Panamax PM8-AV User manual

Panamax

Panamax PM8-AV User manual

Popular Surge Protector manuals by other brands

Philips Theatre Director SPP4200WA/17 Owner's manual & warranty

Philips

Philips Theatre Director SPP4200WA/17 Owner's manual & warranty

M-system MMA instruction manual

M-system

M-system MMA instruction manual

CyberPower CSP600WSU user manual

CyberPower

CyberPower CSP600WSU user manual

UTP BALUN SP-VD08 user manual

UTP BALUN

UTP BALUN SP-VD08 user manual

ELAC ProteK PR91-W Setup guide

ELAC

ELAC ProteK PR91-W Setup guide

Tsubaki TSM4000M1 instruction manual

Tsubaki

Tsubaki TSM4000M1 instruction manual

CyberPower B1006T user manual

CyberPower

CyberPower B1006T user manual

QVS PP134C Specification sheet

QVS

QVS PP134C Specification sheet

Davis Instruments Radio Surge Protector user guide

Davis Instruments

Davis Instruments Radio Surge Protector user guide

CyberPower B300WRC1 user manual

CyberPower

CyberPower B300WRC1 user manual

M-system MGD-24 instruction manual

M-system

M-system MGD-24 instruction manual

OBO Bettermann ÜSM-20-230I1PE65 installation instructions

OBO Bettermann

OBO Bettermann ÜSM-20-230I1PE65 installation instructions

CyberPower CSP604T user manual

CyberPower

CyberPower CSP604T user manual

CyberPower CSP706T user manual

CyberPower

CyberPower CSP706T user manual

Mitsubishi Electric LITOL LTM-125RF manual

Mitsubishi Electric

Mitsubishi Electric LITOL LTM-125RF manual

Intermatic PS3000 installation instructions

Intermatic

Intermatic PS3000 installation instructions

Siemens SICROWBAR 7VV3003 operating instructions

Siemens

Siemens SICROWBAR 7VV3003 operating instructions

Joslyn Surgitron I 1260 Installation, operation and maintenance manual

Joslyn

Joslyn Surgitron I 1260 Installation, operation and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

www.panamax.com
• Linear Noise Filtration
Technology (Lift)
• 600VA UPS 2 Outlets
• Surge Protection with
• Automatic Voltage
• Monitoring (AVM)
• Dual Learning IR
• Output Controls
• Rack Mounting Kit
MX5102
WITH BATTERY BACKUP FOR YOUR
HOME THEATER SYSTEM
COMPLETE POWER MANAGEMENT
MX5102
COMBINES POWER MANAGEMENT, SURGE PROTECTION WITH AVM
AND BATTERY BACKUP TO PROVIDE THE COMPLETE SOLUTION!
Features
Panamax’s MX5102 is specially designed and engineered for home theater systems.
In addition to power management the battery backup prevents processor controlled
devices and hard drive based sources from losing critical data and set up
configurations, as well as allowing for a proper shut down procedure.
MX5102 SPECIFICATIONS
Outlet Bank 2
Four switched outlets with Linear
Filtration Technology (LiFT) controlled
by the front panel Power Button or the
DC Trigger input. Bank 2 will turn on
immediately and turn off after 5
seconds. Its output is noise isolated
from all other banks.
Outlet Bank 1
Two always on outlets with Linear
Filtration Technology (LiFT). Power
will only be turned off under a fault
condition. Its output is noise
isolated from all other outlet banks.
LAN Jack
Protection circuit for one 10/100
baseT Ethernet line. Incoming
LAN line MUST be plugged into
the LINE jack. Patch cord to the
equipment MUST be plugged
into the EQUIP jacks. 8 wire
protection, 50V clamping.
Phone Jack
Protection circuit for one standard
telephone or pay-per-view lines.
Phone circuit is auto-resetting.
Incoming phone cord MUST be
plugged into the LINE jack. Patch
cords to the equipment (satellite
receiver, digital video recorder,
telephone, etc.) MUST be plugged
into the EQUIP jacks. 2-wire
protection, 270V clamping.
Universal TV Coaxial Jacks
3 pairs of bidirectional
protection circuits optimized for
satellite, cable, and antenna TV
signal lines.
Voltage Sense
Trigger Input
3.5mm (1/8”)
Mini-Plug jack.
1690 Corporate Circle, Petaluma, CA. 94954 • 800-472-5555 • 707-283-5900
Fax 707-283-5901 • www.panamax.com
L616 REV. C 10/09
© 2009 Panamax Inc. Panamax and the Panamax logo are registered US trademarks of Panamax.
MADE IN CHINA
C US
LISTED
3 Year
Product
Warranty
2 Year
Battery Warranty
$5,000,000
Lifetime Limited
Connected
Equipment
Policy
FRONT/BACK PANELS FEATURES
MX5102
WEIGHTS & MEASUREMENTS, QUANTITIES, UPC’S
FOR ORDERING & SHIPPING
SINGLE MODEL MX5102
Dimensions Weight
L 17” x H 4” x W 13” 27 lbs.
SINGLE UNIT CARTON
Dimensions Weight UPC
L 22.25 x H 9.25” x W 17.5” 29 lbs. 050616-008501
MODEL: MX5102
MX5102 prevents critical equipment from losing setup configuration,
stored data and hard-disk crashes. Shuts off projection equipment
via IR control to allow the projector bulbs to go through a proper
cool-down cycle before shutting off.
DC Trigger Input
Jacks 3.5mm (1/8”) mono mini-plug
Voltage and Polarity 3 - 18V DC, bidirectional
Current Requirement 4.6 mA @3V, 58 mA @24V
LAN Circuits
Clamping Level 50V
Jacks RJ-45
Wires Protected 8-Wires
Telephone Circuit
Fuseless/Auto-resetting Yes
Clamping Level 270V
Suppression Modes Metallic & Longitudinal
Jacks RJ-11
Wires Protected 2-Wire, Pins 4 & 5
Cable and Satellite Circuits
HD 1080 i/p Ready Yes
Bi-directional Yes
Shielded Yes
Clamping Level 75V
Frequency Range 0MHz - 2.2 GHz
Insertion Loss < 0.5 dB
Connections Female “F”, Gold Plated
Specifications subject to change due to product upgrades
and improvements.
AC Power
Line Voltage 120V, 60Hz
Total Current Capacity 12 A
Energy Dissipation 1800 Joules
Catastrophic Surge Circuit Yes
Thermal Fusing Yes
Overvoltage Shutoff, fast rise 150 ± 5 V
Overvoltage Shutoff, slow rise 132 ± 5 V
Undervoltage Shutoff 90 ± 5 V
EMI/RFI Noise Filtration
30dB min from 100kHz-2MHz
50dB max @ 270kHz
UPS Output
Voltage 120 ± 5% Simulated Sine Wave
Frequency 60 Hz ± 1%
UPS Output Capacity 600VA 360W @ 0.6pf
UPS Backup Time 3 minutes at full load
Transfer Time < 10ms
Power Switch
Press the power button to
turn the unit ON or OFF.
Digital Voltmeter/UPS Status Display
During normal operation, the digital LED voltmeter indicates the
incoming line voltage. If line voltage drops below 90VAC, or
exceeds 132VAC, the Unsafe Voltage LED will flash, and during
battery backup (UPS) mode the display will indicate the
estimated minutes of battery backup time.
Removable Battery
Access Panel
Easy to remove for battery
access and replacement.
Unsafe Voltage
Indicator
This LED will illuminate
in red to warn the user
that an unsafe voltage
level is occuring.
Wiring Fault Indicator
This LED will illuminate
in red to warn the user
that a wiring problem
such as a bad/missing
ground or reversed wiring
exists within the AC
receptacle. If illuminated,
disconnect all equipment
and contact an electrician
to insure outlet is
properly wired.
Meter Dimmer /UPS Test Button
A quick press of the button will cycle the meter and front panel
through several levels of brightness. Press and hold the button to
initiate an UPS test cycle. During UPS mode, pressing the button
will turn off the internal warning buzzer.
AC Power Cord
10 ft.
Outlet Bank 3
Two switched, high-current outlets controlled by the
front panel Power Button or the DC Trigger input. Bank
3 has a 5 second turn on delay and turns off
immediately. The High Current outlet provides power
from a low impedance noise filtration circuit that does
not limit the current to your equipment. Its output is
noise isolated from all other outlet banks.
IR Control Section
Indicator LED’s – Indicates status IR Output Jacks – Standard 1/8” (3.5mm) mono
jack for connection to an IR flasher (IR flashers not included).
Circuit Breakers
Resettable circuit breakers provide
optimal overload protection.
Outlet Banks 1, 2,3
and 4 Indicators
Illuminated blue when
respective outlet bank
is always on.
Outlet Bank 4
Two always on, battery
powered, surge protected
outlets for connected
equipment ensure temporary
uninterrupted operation of
connected equipment during
a power failure.