INSTRUCTION MANUAL
Digital Display Pressure Sensor
DP-00□(Z)
CMJE-DP0 No.0052-51V
Thank you very much for purchasing Panasonic products.
Read this Instruction Manual carefully and thoroughly for
the correct and optimum use of this product. Kindly keep
this manual in a convenient place for quick reference.
WARNING
●Never use this product as a detection device for
personnel protection.
●
In case of using devices as detectors for personnel
protection, use products which meet laws and stan-
dards, such as OSHA, ANSI or IEC etc., for person-
nel protection applicable in each region or country.
●
This product is used for noncorrosive gas. The
product shall not be used for liquid or corrosive gas.
Never use fluids having inflammability, toxicity,
etc., that affect the human body, either.
●A product intended for use in Japan conforms to
the Japanese Measurement Act. Do not use a
product intended for use overseas in Japan.
1
APPLICABLE STANDARDS / REGULATIONS
●This product complies with the following stan-
dards / regulations.
<European Directive>
EMC Directive
●Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
2PART DESCRIPTION
Connecting connector
Pressure port
(M5 female thread)
Mode selection key
Digital display unit
OVER mark
OFF mark
ON mark
Key lock
mark
Setting value DOWN key
Setting value UP key
3PIPING
●When using this product, connect a joint available
in the market to the pressure port. At the time, the
tightening torque should be 1.0N·m or less.
4MOUNTING
Sensor mounting bracket MS-DP1-1
●When mounting this product with sensor mount-
ing bracket, etc., the tightening torque should be
0.5N·m or less.
M3 (length 6mm) screws with washer
(Accessory with MS-DP1-1)
Sensor mounting bracket
MS-DP1-1
Panel mounting bracket MS-DP1-8
<How to mount>
1. Fit the panel mounting adapter on the front side
of the sensor. Mounting direction of the panel
mounting adapter differs depending on the
mounting direction of the panel mounting bracket.
●For horizontal adjacent mounting
• Mount the panel mounting adapter and the
panelmountingbracketsothatthexinghooks
are vertical.
Panel mounting
adapter
Fixing hooks Fixing hooks
Panel mounting
bracket
●For vertical adjacent mounting
• Mount the panel mounting adapter and the
panelmountingbracketsothatthexinghooks
are horizontal.
Panel mounting adapter
Fixing hooks
Fixing hooks
Panel mounting
bracket
2. Insert to the panel, in condition 1.
3. Insert the panel mounting bracket from the rear
side of the sensor till it touches the panel.
<Dimensions of panel cutout>
●For single mounting (Unit: mm)
55 or more
55 or more
31 0
-
0.4
31 0
-
0.4
(Panel thickness: 1 to 3)
●For adjacent mounting (Unit: mm)
X
31 0
-
0.4
When n pieces are mounted
X = 31 × n + 3.5 × (n - 1)
Note: In case of adjacent mounting, be sure to keep apart from each other
in 55mm or more as well as for single mounting.
<How to remove>
●Pull out the panel mounting bracket while pushing
the removing levers out.
Panel mounting bracket
Removing lever
Removing lever
Notes: 1) Take care that it the sensor is forcibly pulled, the sensor itself or
the panel mounting bracket may break.
2) Do not reuse the panel mounting adapter which has been used
once.
5WIRING
How to connect
●Insert the cable with con-
nector CN-14A-C□ into this
product’s connection con-
nector section as shown in
therightgure.
How to disconnect
●Pressing the release lever
of the cable with connector,
pull out the connector.
Release lever
Cable with connector
CN-14A-C□
<Recommended product>
Contact:
SPHD-001T-P0.5
Housing: PAP-04V-S
[Manufactured by JST Mfg. Co., Ltd.]
Note: Do not pull by holding the cable without pressing the release lever,
as this can cause cable break or connector break.
<Connector pin arrangement>
1 2 3 4
Connector
pin No.
Terminal name
1 +V
2 Comparative output
3 No connection (Note)
4 0V
Note: Open or, Connect to 0V.
6I/O CIRCUIT DIAGRAMS
NPN output type
Main circuit
(Brown) +V
(Black) Comparative output
(White) No connection
(Note)
(Blue) 0V
Load +
12 to 24V DC±10%
−
PNP output type
(White) No connection
(Note)
+
12 to 24V DC±10%
−
Main circuit
(Brown) +V
(Black) Comparative output
(Blue) 0V
Load
Note: Open or, Connect to 0V.
7
OUTPUT MODE AND OUTPUT OPERATION
●The EASY mode, hysteresis mode or window
comparator mode can be selected as the output
mode.
For details, refer to <Detailed setting mode> in
“
12
Menu setting mode.”
EASY mode
●The comparative output ON / OFF state can be
controlled in this mode.
Pressure
P-1
0
ON
OFF
Comparative
output
H (Hysteresis)
H:Hysteresisxed(4digits)
(10 digits or more when the product is for overseas use and used in units of psi.)
Hysteresis mode
●The comparative output ON / OFF state can be
controlled with randomly set hysteresis in this
mode.
0
Pressure
P-2
P-1
ON
OFF
Comparative
output
H (Hysteresis)
H: 2 digits or more
(5 digits or more when the product is for overseas use and used in units of psi.)
Window comparator mode
●In this mode, the ON or OFF state of the compar-
ative output is controlled with a pressure in the
set range.
Pressure
0
ON
OFF
Comparative
output
H (Hysteresis)
P-2
P-1
H (Hysteresis)
H:Hysteresisxed(4digits)
(10 digits or more when the product is for overseas use and used in units of psi.)
8ERROR INDICATION
Error
indication Description Remedy
The load is short-circuited
causing an overcurrent to
ow.
Turn OFF the power and
check the load.
Pressure is applied during
zero point adjustment.
Applied pressure at the
pressure port should be
brought to atmospheric
pressure and zero-point
adjustment should be done
again.
The applied pressure ex-
ceeds the upper limit of the
displayed pressure range. Applied pressure range
should be brought within
the rated pressure range.
The applied pressure ex-
ceeds the lower limit (back
pressure) of the displayed
pressure range.
When other error massage is displayed, contact us.
9SPECIFICATIONS
●Model No.
DP-00 1 2 -3-4-5
1: 1: Low pressure type, 2: High pressure type
2:
None: For outside of Japan, Z: For inside of Japan
3: None: NPN output type, P: PNP output type
4:
None: With cable with a connector, J: Without attachment
5: None: Without attachment
H1: With sensor mounting bracket
H2: With panel mounting bracket
Type Low pressure type High pressure type
Pressure type Gauge pressure
Rated pressure range
-100.0 to +100.0kPa 0.000 to +1.000MPa
Displayable / settable
pressure range
-101.0 to +101.0kPa -0.010 to +1.010MPa
Pressure resistance
500kPa 1.5MPa
Applicableuid Air, Non-corrosive gas
Supply voltage 12 to 24V DC ±10% Ripple P-P 10% or less
Current consumption
30mA or less
Comparative
output
<NPN output type>
NPN open-collector transistor
• Maximum sink current: 50mA
• Applied voltage: 30V DC or less
(between comparative output and 0V)
•
Residual voltage: 2V or less (at 50mA sink current)
<PNP output type>
PNP open-collector transistor
• Maximum source current: 50mA
• Applied voltage: 30 V DC or less
(between comparative output and + V)
•
Residual voltage: 2 V or less (at 50mA source current)
Output operation
Selectable either NO or NC, with key operation
Hysteresis
Refer to “
7
OUTPUT MODE AND OUTPUT OPERATION”
Repeatability ±0.2% F.S.
(within ±4 digits)
±0.4% F.S.
(within ±4 digits)
Response time 2.5ms / 25ms / 250ms Selected by key operation
Protection IP40 (IEC)
Ambient temperature
0 to +50°C (No dew condensation)
Storage: -10 to +60°C
Ambient humidity 35 to 85% RH, Storage: 35 to 85% RH
Pollution degree 2
Overvoltage category
I
Usable altitude 2,000m or less
Temperature
characteristics
(+20°C standard)
+10 to +40°C:
Within ±1% F.S.
0 to +50°C:
Within ±2.5% F.S.
+10 to +40°C:
Within ±2% F.S.
0 to +50°C:
Within ±5% F.S.
Material
Enclosure: PBT, LCD display: Acryl
Pressure port: Brass-nickel plating
Mounting screw section: Brass, O-ring: Nitrile rubber (NBR)
Key section: Polycarbonate
Weight
(Main body only) Approx. 25g
Accessories
CN-14A-C2 (Cable with a connector, 2m long) (optional for Jtype): 1 pc.
MS-DP1-1 (Sensor mounting bracket) (only H1 type): 1 pc.
MS-DP1-8 (Panel mounting bracket) (only H2 type): 1 pc.
10
CAUTIONS
●This product has been developed / produced for
industrial use only.
●The product shall be used only within the rated
pressure range.
●
Do not apply pressure exceeding the pressure resis-
tance. Otherwise, destruction of diaphragm occurs,
preventing the product to perform normal operation.
●Make sure that the power supply is OFF while
performing the wiring operation.
●Verify that the supply voltage variation is within
the rating.
●
If power is supplied from a commercial switching reg-
ulator, ensure that the frame ground (F.G.) terminal of
the power supply is connected to an actual ground.
●In case noise generating equipment (switching
regulator, inverter motor, etc.) is used in the vicini-
ty of this product, connect the frame ground (F.G.)
terminal of the equipment to an actual ground.
●Do not use during the initial transient time (0.5
sec.) after the power supply is switched ON.
●
When extending the cable, use a cable whose con-
ductor cross-sectional area is 0.3mm
2
or more. The
cable can be extended to up to 10m in total length.
●
Do not run the wires together with high-voltage lines
or power lines or put them in the same raceway.
This can cause malfunction due to induction.
● Thespecicationmaynotbesatisedinastrong
magneticeld.
●This product is suitable for indoor use only.
●Take care that an excessive stress is not applied
to the unit. Otherwise, pressure values may vary.
●
Take care that strong impact such as fall is not giv-
en to this product. Otherwise, it may be destroyed.
●Avoid dust, dirt, and steam.
●When cleaning, wipe off with a soft cloth that does
not make dirt.
●Take care that the product does not come into
contact with organic solvents such as thinner.
●Take care that the product does not come into
contact with oil or grease.
●Take care that the product does not come into
contact with strong acid or alkaline.
●Do not insert wire into the pressure port. Other-
wise, destruction of diaphragm occurs, preventing
the product to perform normal operation.
●Make sure that stress by forcible bend or pulling
is not applied to the sensor cable joint.
●Never disassemble or modify the product.
11
FACTORY SETTINGS
Type Low pressure type High pressure type
Operation setting EASY mode
NO / NC setting NC NO
Threshold value -50.0 0.500
Pressure unit kPa MPa
Display color Red when ON, White when OFF
Response speed 2.5ms
12
MENU SETTING MODE
Display during output operation
Output OFF Output ON
*: Settings of output operation and display colors can be changed in "Dis-
play color setting mode" of "Setting mode."
Threshold value setting mode
RUN mode
After 10 sec.
After 10 sec.
or
1 sec.
1 sec.
2 sec.
2 sec.
*: Displayed only when hysteresis mode / window comparator mode is
set.
Zero point adjustment mode
RUN mode
When adjustable
When unadjustable
2 sec.
3 sec.
Key lock setting / release mode
<Setting of key lock>
1 sec.
1 sec.
2 sec.
<Release of key lock>
1 sec.
1 sec.
2 sec.
*: The key lock mark appears for 1 sec. when key operation is performed
in RUN state with the key lock set (turns OFF in RUN state).
Detailed setting mode
2 sec.
RUN mode
Pressure unit setting mode (Note 1)
Operation setting mode
Settings initializing mode
NO / NC setting mode
mmHg (Note 3)
psi
barkgf/cm2
kPa (Note 2)
EASY mode
No Yes
NO NC
Hysteresis
mode
Window compar-
ator mode
2 sec.
1 sec.
1 sec.
1 sec.
1 sec.
2 sec.
2 sec.
2 sec.
Response speed setting mode
2.5ms 25ms 250ms
1 sec.
2 sec.
Display color setting mode
Red when ON
White when OFF
White when ON
Red when OFF
Always red
Always white
1 sec.
2 sec.
1 sec.
Notes: 1) The pressure unit setting mode is not displayed in the product
intended for use in Japan.
2) “MPa” is used for high pressure type.
3) “mmHg” is used only for low pressure type.
4) When setting change has been made, do not turn OFF the pow-
er supply within 5 sec. after returning to RUN mode.
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Ofce)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
For sales network, please visit our website.
© Panasonic Industrial Devices SUNX Co., Ltd. 2015
PRINTED IN JAPAN

Other Panasonic Accessories manuals

Panasonic HG-F Series User manual

Panasonic

Panasonic HG-F Series User manual

Panasonic HL-C235CE-W Series User manual

Panasonic

Panasonic HL-C235CE-W Series User manual

Panasonic SF4C Series User manual

Panasonic

Panasonic SF4C Series User manual

Panasonic WX-LA20 User manual

Panasonic

Panasonic WX-LA20 User manual

Panasonic LA-511 User manual

Panasonic

Panasonic LA-511 User manual

Panasonic AR42P9W - Plasma Panel anti-glare Filter User manual

Panasonic

Panasonic AR42P9W - Plasma Panel anti-glare Filter User manual

Panasonic LM10 User manual

Panasonic

Panasonic LM10 User manual

Panasonic MA3X703 User manual

Panasonic

Panasonic MA3X703 User manual

Panasonic HL-G1 A-C5 Series User manual

Panasonic

Panasonic HL-G1 A-C5 Series User manual

Panasonic Schottky Barrier Diodes MA3X721 (MA721) User manual

Panasonic

Panasonic Schottky Barrier Diodes MA3X721 (MA721) User manual

Panasonic MA Motion Sensor Series User manual

Panasonic

Panasonic MA Motion Sensor Series User manual

Panasonic HL-G1-A-C5 Series User manual

Panasonic

Panasonic HL-G1-A-C5 Series User manual

Panasonic KX-HNS104FX User manual

Panasonic

Panasonic KX-HNS104FX User manual

Panasonic MALS180XG User manual

Panasonic

Panasonic MALS180XG User manual

Panasonic MA2J1150G User manual

Panasonic

Panasonic MA2J1150G User manual

Panasonic EE23 User manual

Panasonic

Panasonic EE23 User manual

Panasonic MA3SD29FG User manual

Panasonic

Panasonic MA3SD29FG User manual

Panasonic SF-C14EX User manual

Panasonic

Panasonic SF-C14EX User manual

Panasonic MA24D58 User manual

Panasonic

Panasonic MA24D58 User manual

Panasonic WV-PB5504A User manual

Panasonic

Panasonic WV-PB5504A User manual

Panasonic MA2SE010G User manual

Panasonic

Panasonic MA2SE010G User manual

Panasonic MA2Z748 User manual

Panasonic

Panasonic MA2Z748 User manual

Panasonic Light Emitting Diodes LN222RPX User manual

Panasonic

Panasonic Light Emitting Diodes LN222RPX User manual

Panasonic HG-S Series User manual

Panasonic

Panasonic HG-S Series User manual

Popular Accessories manuals by other brands

Keithley 2000-Scan instruction manual

Keithley

Keithley 2000-Scan instruction manual

Di-soric OKTTI 55 M 30 FG3LK-IBS manual

Di-soric

Di-soric OKTTI 55 M 30 FG3LK-IBS manual

Daga Flexyheat NC Directions for use

Daga

Daga Flexyheat NC Directions for use

Banner TCNM-ACM-OM110 installation manual

Banner

Banner TCNM-ACM-OM110 installation manual

Axis 0734-001 installation instructions

Axis

Axis 0734-001 installation instructions

Hunter LIT-293 manual

Hunter

Hunter LIT-293 manual

Giropes Baxtran TC15 user manual

Giropes

Giropes Baxtran TC15 user manual

GRASS VALLEY 8964FS - datasheet

GRASS VALLEY

GRASS VALLEY 8964FS - datasheet

Siemens IR270CT user manual

Siemens

Siemens IR270CT user manual

HoMedics ARMH-210 instruction manual

HoMedics

HoMedics ARMH-210 instruction manual

Bang & Olufsen BEOLINE Guides & online training

Bang & Olufsen

Bang & Olufsen BEOLINE Guides & online training

Autonics BY Series product manual

Autonics

Autonics BY Series product manual

Campbell CS100 product manual

Campbell

Campbell CS100 product manual

U-Turn SECURE 3 Series manual

U-Turn

U-Turn SECURE 3 Series manual

Bose ShowMatch DeltaQ SMGSB Safety and installation guide

Bose

Bose ShowMatch DeltaQ SMGSB Safety and installation guide

Apogee Instruments SU-200 owner's manual

Apogee Instruments

Apogee Instruments SU-200 owner's manual

Vega MINITRAC 31 Quick setup guide

Vega

Vega MINITRAC 31 Quick setup guide

Velleman DB5 user manual

Velleman

Velleman DB5 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.