ROOM AIR CONDITIONING
June 2013
Panasonic Corporation of North America
Air Conditioning Group
1690 Roberts Blvd., NW, Suite 110, Kennesaw, GA 30144
WWW.PANASONIC.COM/AIRCON
Use of the AHRI Certified™ mark indicates
a manufacture's participation in the
certification program.
For verification of certification for individual
products, go to www.ahridirectory.org
Because its products are subject to continuousimprovements, Panasonic reserves the right to modify productdesign and specifications without notice and withoutincurring anyobligations.
©Copyright 2013, Panasonic Air Conditioning Products.
Caution Related to Safety Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the damage and deterioration in safety due to usage of other refrigerant.
JUNE 2013
Quality
Management
System
Certificate
Environmental
Management
System
Certificate
Certified toISO 14001: 2004
Cert.No.: MY-ER 0112
Certified to ISO 9001: 2008
Panasonic HA Air-Conditioning (M)
Sdn.Bhd.
Cert. No.: MY-AR1010
Certified to ISO 14001:20 04
Panasonic HA Air-Conditioning (M)
Sdn.Bhd.
Cert. No.: MY-ER0112
Certified toISO 9001: 2008
Cert.No.: MY-AR 1010
Panasonic has employed ECONAVI (Human Detection Technology) on its air conditioner beginning in 2007 and perfected the feature
since its launch. Panasonic is now introducing ECONAVI air conditioner to the US market.
ECONAVI's smart technology monitors and senses when there are people in the room and determines
how much activity is occurring, then automatically adjusts the temperature setting accordingly for optimum operation.
The low activity detection mode monitors the room, decreasing cooling when there is less movement, while the absence detection
feature switches to a slightly less powerful cooling mode when there is no one in the room at all.
ECONAVI with Intelligent Eco Sensors
ECONAVI in coolingmode: *The target temperature setby ECONAVIwill be restoredautomaticallyto the set temperature whena new condition is detected.
ECONAVI detects human
absence in the roomand
raises the target temperature.
Absence Detection
No one is in the room.
Detects absence.
Gradually modulates
cooling power by setting
the new target temperature
(set temp +4˚F)
DETECT CONTROL
Set Temperature Cooling Power
Legend:
Fan Speed
125
4
+4°F
-2°F
Set Temperature
Absent
Exit Room OutLow activityEnter Room Normal activity
High activity
3
Present
20min. 20min.
+2°F
-4°F 1 Hour
+4°F
-4°F
Max Medium FanSet Speed Set Speed Set Speed
Remark: Set temperature on remote control display remains unchanged.
Heating Power
HOW DOES ECONAVI HUMAN ACTIVITY WORK?
ECONAVI detects changes in
activity levels and reduces the
cooling power by adjusting
set temperature.
Activity Detection
Level of activity is
decreased. Detects low
activity.
Reducescoolingpowerby
settingnew target
temperature
(settemp +2˚F)
CONTROLDETECT
Adjustscooling and
heatingpower to your
activities.
Activity Detection
Human
Activity Sensor
Reduces coolingand heating
powerwhen you are notin the
room.
Absence Detection
EXTERIOS
Serving the US Ductless
market since 1983
SEER
28.5
Features
Cool/Dry
Mode
Heat Mode
Microprocessor control ensures that the
temperature and humidity levels in the room are
always comfortable.
Microprocessor-Controlled
Operation
ECONAVI features intelligent Human Activity
Sensor and new technologies that can detect
human activity and absence, and optimize air
conditioner operation according to room
conditions.
ECONAVI
Panasonic’s infrared Remote Control with and
easy-to-read LCD Display, gives the user the
capability to adjust & set: temperature, sweep
(louver control), fan speeds, timer and more, for
complete automatic operation.
Wireless Remote Control
Convenient microprocessor control automatically
adjusts fan speed to High, Medium or Low.
According to room temperature to maintain a
comfortable airflow throughout the room.
5 Fan Speeds and Automatic
Fan Operation
The air sweep function moves the louver up and
down in the air outlet, directing air in a “sweeping”
motion around the room and providing comfort in
every corner.
2 air
guides
Air Sweep Control
Louver can be manually set to the desired angle
by remote control.
Louver Control
After setting the temperature and functions
you desire, just relax. If the room temperature
is higher than the set temperature, cooling
operation begins. If the room temperature
is lower than the set temperature, heating
operation begins. During normal thermostat
cycle operation, cooling and heating operations
automatically change in accordance with set
temperature, time and room temperature
(Single Zone Heat Pump unit only).
Automatic Heating and
Cooling Changeover
The remote control unit allows you to set a
wide variety of timer-based operations. Such
functions include automatic ON/OFF with a timer
setting, same time ON/OFF every day, ON timer,
OFF timer and Combination timer.
24-hour Clock with ON/OFF
Program Timer
Automatic Restart Function
after Power Failure
LOW, low fan speed for extra quiet operation.
Quiet Mode
Self-Diagnosing Function
The circulation volume of the refrigerant is
controlled by a pulse type electric control valve.
In order to attain optimum efficiency, when the
power is switched ON, the opening degree of the
electric control valve is controlled between 90
and 480 step.
Electric Refrigerant Control
Valve
By coupling compressor and fan operation,
intermittent operation can be precisely controlled
according to room temperature, so that air is
efficiently dehumidified.
Dry Mode
Right from the start, air is warm and comfortable.
The Hot Start Heating System prevents any cold
blasts at the beginning while the heat pump is
warming up (Heat pump unit only).
Hot Start Heating System
Condensers can take a beating from exposure to
salty air, rain and other corrosive factors.
Panasonic has extended the life of its
condensers with an original anti-rust coating.
Blue Fin Condenser
Room Freeze Protection mode helps prevent
plumbing damage due to sub-Freezing
Temperature. This mode automatically turns on
the compressor for heat pump operation if the
room temperature falls to about 46°F.
*This function may not be performed if the unit is
not powered, or if the unit is unable to operate
such as in protection mode. Please consult with
the HVAC installers.
Room Freeze Protection
Panasonic Adds a "NEW Air Conditioner" Line-up...
Setting Another Milestone in the History of Ductless Split.
No.1* High Energy Efficiency*
Breakthrough technology such as the inverter, enables the highest energy efficiency* in the
industry. Thanks to this exceptional performance, you can enjoy more comfort.
*CS/CU-XE9PKUA as of March 2013
LOW
AMBIENT
OPERATION
SEER
28.5
Powerful Heating at Low Ambient
Inverter Technology
Heating is still possible even if the temperature drops as low as 0˚F for reliable heating in the
middle of the harshest winter.
Panasonic's inverter technology provides optimum power control and extremely efficient
operation by changing the power supply frequency. The result is speedy, flexible operation using
less electricity.
Innovative Inverter Technology
The inverter constantly adjusts the compressor rotation speed to provide optimum
performance at all times. After reaching the set temperature, an inverter air conditioner
continues to operate with minimum power to avoid unnecessary electricityconsumption.
Conventional non-inverter air conditioners can only operate ataconstant speed,switching the
compressorON and OFFto maintain thesettemperature, which wastes electricity.
20dB
30dB
40dB
50dB
60dB
80dB
Leavestouch together
Whispervoice
In a library
In a office
In a subway
Normalconversation
Inverter Compressor
Panasonic’s Inverter Compressor can achieve high efficiency under
highload conditions.With accumulated productionof 200 Million
compressors, extremely high quality andreliability areproven.
High Efficiency &
High Reliability Material
for longer life span andto
withstand high pressure.
High Efficiency Motor
for wide operating voltage.
Optimum Shape
Muffler
for quiet operation.
Indoor Unit
CS-XE9PKUA / CS-XE12PKUA
12,000Btu/h
Maximum capacity 8,700Btu/h
Rated capacity 2,800Btu/h
Minimum capacity
Even Wider Output Power Range
The graph shows CS-XE9PKUA's wide power
output range during cooling. * This is maximum elevation difference when the indoor unit is located above the outdoor unit.
*Image of output power fluctuation
Advantages of Inverter Control
Comparing inverter and non-inverter air conditioners to cars.
The accelerator can't be adjusted, so you spend a long
time to get comfortable, then soon become uncomfortable.
Keeps the temperature
comfortable all the time.
Adjusts the accelerator and
thus runs more economically.
Reaches the comfortable
zone quickly.
START
Runs at a fixed speed, so it takes
longer to reach the comfort zone.
The room gets too cold,
then too warm.
Uncomfortable
Comfortable
Uncomfortable
Non-inverter air conditioner
Inverter air conditioner
Cooler
Less Cool
Room temperature
Setting Temperature
Model No.
Room Freeze Protection
XE9PKUA XE12PKUA
Unit Model No. Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
CS-XE9PKUA CU-XE9PKUA CS-XE12PKUA CU-XE12PKUA
Performance & Electrical Ratings
Capacity Cooling Btu/h 8,700(2,800~12,000) 11,500(2,800~14,000)
Heating Btu/h 12,000(3,000~18,000) (10,600 at 17˚F) 13,800(3,000~23,000) (13,500 at 17˚F)
Moisture Removal High Pints/H 1.3 2.3
Dry Air Flow High CFM 405 530
SEER Cooling 28.5 25.5
EER Cooling 16.1 14.35
HSPF Heating 12.5 12.0
Power Supply V, Phase, Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz
Running Amps Cooling A 2.5/2.8 3.8/4.2
Heating A 4.0/4.5 5.2/5.8
Power Input Cooling W 540(150-850) 800(150-1,050)
Heating W 860(150-1,650) 1,150(150-2,100)
Back-up Heater kW --- ---
Fuse or Circuit BreakerCapacity
A 15 20
Features
Controls Microprocessor Microprocessor
Low Ambient Control Equipped Equipped
Wireless Remote Controller Included Included
Wired Remote Controller (optional) CZ-RD516C CZ-RD516C
Fan Speeds 5 Speeds + Auto 5 Speeds + Auto
Timer 24hr Program 24hr Program
Air Deflection Horizontal Manual Manual
Vertical Automatic Automatic
Air Filter Washable + Anti Microbial Filter Washable + Anti Microbial Filter
Refrigerant R-410A R-410A
Refrigerant Control Electric Expansion Valve Electric Expansion Valve
Operation Sound In(Hi / Lo/ Q-Lo)dB-A 42 / 25 / 20 45 / 28 / 20
Outdoor(Hi) dB-A 48 49
Refrigerant Piping Type Flare Flare
Discharge in. 1/4” 1/4”
Suction in. 3/8” 1/2”
Refrigerant Pipe Length Ft. Max. 66 Max. 66
Elevation Difference* Outdoor Above Ft. Max. 49 Max. 49
Outdoor Below Ft. Max. 49 Max. 49
Dimensions & Weight Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Height in. 11-5/8” 27-3/8” 11-5/8” 27-3/8”
Width in. 34-9/32” 34-15/32” 34-9/32” 34-15/32”
Depth in. 10-1/16” 12-5/8” 10-1/16” 12-5/8”
Net Weight Lbs. 24 97 24 97
Wireless Remote
Controller
Specifications
Outdoor Unit
CU-XE9PKUA
CU-XE12PKUA
Special CoatingLayer
(FinCross-section)
Coolair doesn't reach
you directly so your
hands and feet don't
get cold.
Warmfeet and no direct
breeze on your face
meaneven more
comfort.
Cooling Mode
2 air guides to improve the air flow direction
Heating Mode
Water Air Salt content
Base material Corrosion-resistant layer
2 air
guides
This feature allows the system to automatically
resume operation at its preset program, after
power is restored from a power failure when
the remote control is in the room.
Unit is equipped with Self-Diagnosing Function
with remote controller. This makes it easier to
diagnose malfunctions, reducing service labors.

This manual suits for next models

1

Other Panasonic Air Conditioner manuals

Panasonic CS-F24DD1ES User manual

Panasonic

Panasonic CS-F24DD1ES User manual

Panasonic CS-MC90KE User manual

Panasonic

Panasonic CS-MC90KE User manual

Panasonic CU-RE24HKE User manual

Panasonic

Panasonic CU-RE24HKE User manual

Panasonic CS-TE12HKE-5 User manual

Panasonic

Panasonic CS-TE12HKE-5 User manual

Panasonic CS-PS12PKV-6 User manual

Panasonic

Panasonic CS-PS12PKV-6 User manual

Panasonic CS-C18DKD User manual

Panasonic

Panasonic CS-C18DKD User manual

Panasonic CS-RE9HKE User manual

Panasonic

Panasonic CS-RE9HKE User manual

Panasonic S-36PU1E5A Manual

Panasonic

Panasonic S-36PU1E5A Manual

Panasonic CW-XC125HU User manual

Panasonic

Panasonic CW-XC125HU User manual

Panasonic S-20YM3HPQ User manual

Panasonic

Panasonic S-20YM3HPQ User manual

Panasonic CS-XU9UKH-8 User manual

Panasonic

Panasonic CS-XU9UKH-8 User manual

Panasonic CS-MKE7NKU Installation and user guide

Panasonic

Panasonic CS-MKE7NKU Installation and user guide

Panasonic CW-C53GK User manual

Panasonic

Panasonic CW-C53GK User manual

Panasonic CS-A12CTP User manual

Panasonic

Panasonic CS-A12CTP User manual

Panasonic CS-D34DTH5 User manual

Panasonic

Panasonic CS-D34DTH5 User manual

Panasonic CS-YE9QKE User manual

Panasonic

Panasonic CS-YE9QKE User manual

Panasonic CS-TE25TKEW User manual

Panasonic

Panasonic CS-TE25TKEW User manual

Panasonic CS-PS9QKA User manual

Panasonic

Panasonic CS-PS9QKA User manual

Panasonic CS-LZ18ZKA User manual

Panasonic

Panasonic CS-LZ18ZKA User manual

Panasonic CS-E9SD3UAW User manual

Panasonic

Panasonic CS-E9SD3UAW User manual

Panasonic CS-XE9EKE User manual

Panasonic

Panasonic CS-XE9EKE User manual

Panasonic CS-C9DKZW User manual

Panasonic

Panasonic CS-C9DKZW User manual

Panasonic CS-W12CTP Manual

Panasonic

Panasonic CS-W12CTP Manual

Panasonic CS-PA18JKD User manual

Panasonic

Panasonic CS-PA18JKD User manual

Popular Air Conditioner manuals by other brands

LG L5UC728FA0 installation manual

LG

LG L5UC728FA0 installation manual

Frigidaire CRA073PU11 use & care

Frigidaire

Frigidaire CRA073PU11 use & care

Mitsubishi Electric MSZ-DM25VA operating instructions

Mitsubishi Electric

Mitsubishi Electric MSZ-DM25VA operating instructions

Innova IGZCAPS NI Series owner's manual

Innova

Innova IGZCAPS NI Series owner's manual

Hitachi RAK-18QXD Service manual

Hitachi

Hitachi RAK-18QXD Service manual

MegaLife NEBULA GREEN R32 Use and Installation Instructions

MegaLife

MegaLife NEBULA GREEN R32 Use and Installation Instructions

OMAS Air-Fi AFT7 Installer and User Instruction Manual

OMAS

OMAS Air-Fi AFT7 Installer and User Instruction Manual

Seifert 87622082USL user manual

Seifert

Seifert 87622082USL user manual

Airxcel Marvair ComPac II AVHDA90 Installation & operation manual

Airxcel

Airxcel Marvair ComPac II AVHDA90 Installation & operation manual

Stealth Designer SC-24CC-UM quick start guide

Stealth

Stealth Designer SC-24CC-UM quick start guide

Haier AU362XHERA installation manual

Haier

Haier AU362XHERA installation manual

Mitsubishi Electric MSC-GE20VB operating instructions

Mitsubishi Electric

Mitsubishi Electric MSC-GE20VB operating instructions

Hitachi RAS-10NHZ4(H) instruction manual

Hitachi

Hitachi RAS-10NHZ4(H) instruction manual

Carrier DB-O Series Use and maintenance

Carrier

Carrier DB-O Series Use and maintenance

Whirlpool BHAC1000XS0 Use & care guide

Whirlpool

Whirlpool BHAC1000XS0 Use & care guide

EINHELL Split 3500 EQ C+H operating instructions

EINHELL

EINHELL Split 3500 EQ C+H operating instructions

Mitsubishi Electric MXZ-2D33VA-E1 Service manual

Mitsubishi Electric

Mitsubishi Electric MXZ-2D33VA-E1 Service manual

Lennox LIFHC012021T431E-1 owner's manual

Lennox

Lennox LIFHC012021T431E-1 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.