15
ERROR INDICATION
ƔIn case of errors, attempt the following measures.
Error
indication Description Remedy
EEPROM is broken or reached the end of its
working life. 3OHDVHFRQWDFWRXURႈFH
EEPROM writing error
Load of the sensing output 1 is short-circuited
FDXVLQJDQRYHUFXUUHQWWRÀRZ Turn OFF the power and check the load.
Load of the sensing output 2 is short-circuited
FDXVLQJDQRYHUFXUUHQWWRÀRZ
&RPPXQLFDWLRQHUURUZKHQ WKH DPSOL¿HUVDUH
mounted in cascade.
Verify that there is no loose or clearance between
DPSOL¿HUV
Communication error between the upper com-
PXQLFDWLRQXQLWDQGDPSOL¿HUV
Verify that there is no loose or clearance between
WKHXSSHUFRPPXQLFDWLRQXQLWDQGDPSOL¿HUV
16
SPECIFICATIONS
Type Series connection type
NPN output PNP output
Model No. FX-502 FX-502P
Supply voltage 12 to 24V DC % Ripple P-P10% or less
Power consumption
(Note 1)
Normal operation: 960mW or less (current consumption 40mA or less at 24V supply voltage)
Eco mode: 680mW or less (current consumption 28mA or less at 24V supply voltage)
Sensing output
(Sensing output 1 / 2)
NPN open-collector transistor
• Maximum sink current: 50mA (Note 1)
• Applied voltage: 30V DC or less
(Between sensing output and 0V)
• Residual voltage: 2V or less (Note 2)
[At 50m
A (Note 1)
sink current]
PNP open-collector transistor
• Maximum source current: 50mA (Note 1)
• Applied voltage: 30V DC or less
(Between sensing output and +V
)
• Residual voltage: 2V or less (Note 2)
[At 50m
A (Note 1)
source
current]
Output operation Switchable either Light-ON or Dark-ON
Short-circuit protection
Incorporated
Response time +63ȝVRUOHVV)$67ȝVRUOHVV67'ȝVRUOHVV/21*PVRUOHVV
8/*PVRUOHVV+<35PVRUOHVV6HOHFWDEOH
External input
• Signal condition
High: +8V to +V DC or Open
Low: 0 to +1.2V DC (at 0.5mA source current)
• ,QSXWLPSHGDQFH$SSUR[Nȍ
• Signal condition
High: +4V to +V DC (at 3mA sink current)
Low: 0 to +0.6V DC or Open
• ,QSXWLPSHGDQFH$SSUR[Nȍ
Protection IP40 (IEC)
Ambient temperature
-10 to +55°C (If 4 to 7 units are mounted in cascade: -10 to +50°C or if 8 to 16 units are
mounted in cascade: -10 to +45°C) (No dew condensation or icing allowed)
Storage: -20 to +70°C
Ambient humidity 35 to 85% RH, Storage: 35 to 85% RH
Material Enclosure: Polycarbonate, Key: Polyacetal, Protective cover: Polycarbonate
Weight (Main body only)
Approx. 15g
Accessory FX-MB1 $PSOL¿HUSURWHFWLRQVHDOVHW
Notes:1) 50mA max. if 5 or more series connection types are connected together.
2) In case of using the quick-connection cable (cable length 5m) (optional).
3) Cables are not accessories. Be sure to use cables in table below.
<Series connection type>
Cable
Cable length 1m Cable length 2m Cable length 5m
Main cable Sub cable Main cable Sub cable Main cable Sub cable
);Ƒ CN-74-C1 CN-72-C1 CN-74-C2 CN-72-C2 CN-74-C5 CN-72-C5
17
CAUTIONS
ƔThis product has been developed / produced for industrial use only.
Ɣ 0DNHVXUHWKDWWKHSRZHUVXSSO\LV2))ZKLOHDGGLQJRUUHPRYLQJWKHDPSOL¿HUV
ƔTake care that if a voltage exceeding the rated range is applied, or if an AC
power supply is directly connected, the product may get burnt or be damaged.
ƔTake care that short-circuit of the load or wrong wiring may burn or damage
the product.
ƔDo not run the wires together with high-voltage lines or power lines, or put
them in the same raceway.This can cause malfunction due to induction.
Ɣ 7KHVSHFL¿FDWLRQPD\QRWEHVDWLV¿HGLQDVWURQJPDJQHWLF¿HOG
ƔVerify that the supply voltage variation is within the rating.
ƔIf power is supplied from a commercial switching regulator, ensure that the frame
JURXQG)*WHUPLQDORIWKHSRZHUVXSSO\LVFRQQHFWHGWRDQDFWXDOJURXQG
ƔIn case noise generating equipment (switching regulator, inverter motor, etc.)
LVXVHGLQWKHYLFLQLW\RIWKLVSURGXFWFRQQHFWWKHIUDPHJURXQG)*WHUPLQDO
of the equipment to an actual ground.
Ɣ 7KHXOWUD ORQJ GLVWDQFH 8/* +<35 PRGH LV PRUHOLNHO\WREHDႇHFWHGE\
extraneous noise since the sensitivity of that is higher than the other modes.
Make sure to check the environment before use.
Ɣ 'RQRWXVHGXULQJWKHLQLWLDOWUDQVLHQWWLPH+63)$6767'VHF/21*
8/*+<35VHFDIWHUWKHSRZHUVXSSO\LVVZLWFKHG21
ƔBe sure to using the quick connection cable (optional) as cable. When you ex-
tend the cable, be sure to use cables which have 0.3mm2or more of conductor
cross-section area. Extension up to total 100m is possible. However, in order
to reduce noise, make the wiring as short as possible.
ƔMake sure that stress by forcible bend or pulling is not applied to the sensor
FDEOHMRLQWDQG¿EHUFDEOH
ƔThis product is suitable for indoor use only.
ƔAvoid dust, dirt, and steam.
ƔTake care that the product does not come in contact with oil, grease, organic
solvents such as thinner, etc., strong acid or alkaline.
Ɣ 7KLVSURGXFWFDQQRWEHXVHGLQDQHQYLURQPHQWFRQWDLQLQJLQÀDPPDEOHRUH[-
plosive gasses.
ƔNever disassemble or modify the product.
ƔThis product adopts EEPROM. Settings cannot be done 100 thousand times
or more because of the EEPROM’s lifetime.
13
OPTICAL COMMUNICATION
ƔWhen the setting of data bank loading / saving, copy setting, or copy action
VHWWLQJLVFRQGXFWHG YLD RSWLFDO FRPPXQLFDWLRQV FDVFDGH WKH VXE DPSOL¿HUV
ULJKWVLGHWRWKHPDLQDPSOL¿HUDVIROORZV
However, in case using data bank loading / saving, use FX-502ƑRUFX-505Ƒ-C2
DVPDLQDPSOL¿HU
Ɣ ,IDQDPSOL¿HULVXQGHUDQ\RIWKHIROORZLQJFRQGLWLRQVWKHVHWWLQJRIGDWDEDQN
loading / saving, or copy setting cannot be carried out.
• Copy lock setting is set to copy lock ON “ .”
• Digital display is blinking
• ([WHUQDOLQSXWVHWWLQJRIPDLQDPSOL¿HULVVHWWR“ .” (Only data-
bank loading / saving)
ƔWhen communication protocol of a
sub amplifier is set to communication
emission halt “ ” the setting
of data bank loading / saving, or copy
setting cannot be carried out to sub
DPSOL¿HUVVXEVHTXHQWWRWKHPHQWLRQHG
DPSOL¿HU
ƔMake sure to mount closely like follows
since interference prevention function is
conducted by optical communication.
Main
DPSOL¿HU 6XEDPSOL¿HUV
Communication direction
Ɣ :KHQWKLV SURGXFW DQG RWKHU SURGXFWV HJ ¿EHUVHQVRUDPSOL¿HUVSUHVVXUH
sensor controllers, etc.) are connected together in cascade, install those prod-
XFWVVRWKDWWKH\DUHLQRUGHURI*URXS$%'DQG&DVVKRZQLQWKHULJKW¿J-
XUH7KLVSURGXFWLVLQFOXGHGLQ*URXS'
*URXS
A
*URXS
B
*URXS
D
*URXS
C
Communication direction
*URXS Model No.
AFX-301Ƒ&RQYHQWLRQDOYHUVLRQXQLW
FX-301BƑGƑHƑLS-401Ƒ
BFX-301Ƒ0RGL¿HGYHUVLRQXQLW
FX-305ƑFX-301Ƒ-C1
CLS-403ƑDPS series
DFX-500 series
Ɣ $VIRUWKHSURGXFWVWKDWDUHORFDWHGEHWZHHQGLႇHUHQWJURXSVDႈ[WKHDPSOL-
¿HUSURWHFWLRQVHDO FX-MB1 (optional) on the communication window of each
corresponding product.
ƔWithin each group, identical models should be connected in a lump.
ƔIn case conducting copy setting of this device and other FX-500 series togeth-
er, functions which are incorporated in this device will be copied but functions
which are not incorporated in this device will not be copied.
14
INTERFERENCE PREVENTION FUNCTION
Ɣ 7KLVGHYLFHLQFRUSRUDWHVDQLQWHUIHUHQFHSUHYHQWLRQIXQFWLRQE\VHWWLQJGLႇHUHQWHPLW-
ting frequencies from an interference prevention function by optical communication.
ƔFor Interference prevention function setting procedure, refer to <PRO5> in
“PRO MODE OPERATION MANUAL.”
Ɣ 3RVVLEOHQXPEHURI DPSOL¿HUV IRU LQWHUIHUHQFH SUHYHQWLRQ IXQFWLRQLVGLႇHUHQW
as shown in table below.
Response time
Interference
prevention function setting
H-SP FAST STD /21* 8/* +<35
0248812
Ɣ ,QFDVHSXWWLQJLQPRUHDPSOL¿HUVWKDQOLPLWRILQWHUIHUHQFHSUHYHQWLRQIXQFWLRQ
SXWWKHDPSOL¿HUSURWHFWLRQVHDOWRDPSOL¿HUZKLFKLVDGMDFHQWRIHQGRIDQDPSOL-
¿HUWKDWWKHLQWHUIHUHQFHIXQFWLRQLVYDOLGRUVHW2))LQFRPPXQLFDWLRQSURWRFRO
VHWWLQJRIWKHHQGRIDPSOL¿HUWKDWWKHLQWHUIHUHQFHSUHYHQWLRQIXQFWLRQLVYDOLG
([DPSOH3XWWLQJLQRIWKLVGHYLFHDQGVHW67'RIUHVSRQVHWLPHVHWWLQJ
• Possible number of interference prevention is 4.
3XWWKH DPSOL¿HU SURWHFWLRQ VHDOVWKDQGWKDPSOL¿HUVDQGEHWZHHQWK
DQGWKDPSOL¿HUVRUFKDQJHWKHFRPPXQLFDWLRQSURWRFROVHWWLQJRIWKDQG
8th to OFF since interference prevention works from 1st to 4th, from 5th to
8th and 9th to 12th.
Communication direction
Interference
prevention
possible
range
Put a protection seal between
WKDQGWKDPSOL¿HU
Or set communication protocol
setting in 4th to OFF.
Put a protection seal between
WKDQGWKDPSOL¿HU
Or set communication protocol
setting in 8th to OFF.
Interference prevention
possible range
Interference prevention
possible range
Ɣ ,QFDVHPRXQWLQJ PRUH DPSOL¿HUV ZKRVH UHVSRQVH WLPH VHWWLQJ DUH GLႇHUHQW
SXWSURWHFWLRQVHDOEHWZHHQDPSOL¿HUVWKDWKDYHGLႇHUHQWUHVSRQVHWLPHVHWWLQJ
RUVHWFRPPXQLFDWLRQSURWRFROVHWWLQJRIWKHXSSHUDPSOL¿HUWR2))
ƔFor communication protocol setting procedure, refer to <PRO4> in “PRO
MODE OPERATION MANUAL.”
Panasonic Industrial Devices SUNX Co., Ltd.
https://panasonic.net/id/pidsx/global
Please visit our website for inquiries and about our sales network.
PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2019