● This product has been developed / produced for industrial use only.
● Make sure that the power supply is OFF while adding or removing the ampliers.
● Take care that if a voltage exceeding the rated range is applied, or if an AC
power supply is directly connected, the product may get burnt or damaged.
● Take care that short circuit of the load or wrong wiring may burn or damage the product.
●Do not run the wires together with high-voltage lines or power lines or
put them in the same raceway.
This can cause malfunction due to induction.
● The specication may not be satised in a strong magnetic eld.
● Verify that the supply voltage variation is within the rating.
● If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
●In case noise generating equipment (switching regulator, inverter mo-
tor, etc.) is used in the vicinity of this product, connect the frame ground
(F.G.) terminal of the equipment to an actual ground.
●The ultra long distance (U-LG) mode is more likely to be affected by
extraneous noise since the sensitivity of that is higher than the other
modes. Make sure to check the environment before use.
● Do not use during the initial transient time (0.5 sec.) after the power supply is switched ON.
● Make sure to use the quick-connection cable (optional) for the connection of the controller.
Extension up to total 100m is possible with 0.3mm2 or more, cable.
However, in order to reduce noise, make the wiring as short as possible.
● Make sure that stress by forcible bend or pulling is not applied to the sensor cable joint.
● This product is suitable for indoor use only.
● Avoid dust, dirt, and steam.
●Take care that the product does not come in contact with oil, grease,
organic solvents such as thinner, etc., strong acid or alkaline.
● This product cannot be used in an environment containing inammable
or explosive gasses.
● Never disassemble or modify the product.
● This product adopts EEPROM. Settings cannot be done 100 thousand
times or more, because of the EEPROM’s lifetime.
CAUTIONS
20
SPECIFICATIONS
19
Type Digital laser sensor amplier
Item
Model No.
LS-403
Supply voltage 12 to 24V DC±10% Ripple P-P 10% or less
Power consumption
Normal operation: 950mW or less (current consumption
40mA or less at 24V supply voltage)
Eco mode: 780mW or less (current consumption 33mA or
less at 24V supply voltage)
Output
(Output 1 / 2)
NPN open-collector transistor
• Maximum sink current: 50mA (Note 1)
• Applied voltage: 30V DC or less (between output and 0V)
• Residual voltage: 1.5V or less (Note 2) [at 50mA (Note 1) sink current]
Output operation Switchable either Light-ON or Dark-ON
Short-circuit protection
Incorporated
Response time H-SP: 80μs or less, FAST: 150μs or less, STD: 500μs or
less, U-LG: 4ms or less Selectable with jog switch
Timer function
Changeable in ON-delay, OFF-delay or One-shot delay timer
Switchable either effective or ineffective (timer period: ap-
prox. 0.5ms, approx. 1 to 9,999ms)
Interference
prevention function
Incorporated [Up to four sensor heads can be mounted adjacently (How-
ever, in H-SP mode, up to two sensor heads can be mounted adjacently)]
Ambient temperature
-
10 to +55°C (If 4 to 7 units are cascaded:
-
10 to +50°C, if 8
to 16 units are cascaded:
-
10 to +45°C) (No dew condensa-
tion or icing allowed), Storage:
-
20 to +70°C
Ambient humidity 35 to 85% RH, Storage: 35 to 85% RH
Material
Enclosure: Heat-resistant ABS, Protective cover: Polycarbonate
Jog switch: ABS, MODE key: Acrylic
Weight Approx. 15g (Main body only)
Notes: 1) 25mA max. if 5 or more units are connected in cascade.
2) In case of using the quick-connection cable (cable length 5m) (optional).
3)
Make sure to use the quick-connection cables (optional) given below.
Main cable (4-core):
CN-74-C1 (cable length 1m), CN-74-C2 (cable length 2m), CN-74-C5 (cable length 5m)
Sub cable (2-core):
CN-72-C1 (cable length 1m), CN-72-C2 (cable length 2m), CN-72-C5 (cable length 5m)
4) The values specied above are applied only to the amplier. Regarding the speci-
cations for the applied sensor head, refer to the instruction manual enclosed with
the sensor head.
ERROR INDICATION
17
● In case of errors, attempt the following measures.
Error
indication
Description Remedy
EEPROM is broken or reached
the end of its working life. Please contact our oce.
EEPROM writing error.
Load of the output 1 is short-circuit-
ed causing an overcurrent to ow.
Turn OFF the power and check the load.
Load of the output 2 is short-circuit-
ed causing an overcurrent to ow.
Disconnection error of sensor head.
Check the connection of sensor head.
Communication error when the
ampliers are mounted in cascade.
Verify that there is no loose or clear-
ance between ampliers.
Communication error between the up-
per communication unit and ampliers.
Verify that there is no loose or clearance between
the upper communication unit and ampliers.
●When the setting of data bank loading / saving, or copy setting is con-
ducted via optical communications, cascade the sub ampliers right side
to the main amplier as follows.
● If an amplier is under any of the following conditions, the setting of data
bank loading / saving, or copy setting cannot be carried out .
• In case the digital display is blinking
• In case PRO mode is being set
• In case the communication enable
/ disable setting is set to commu-
nication disable “ ”
● When communication protocol of a sub
amplifier is set to communication halt
“”, the setting of data bank
loading / saving, or copy setting cannot
be carried out to sub ampliers subse-
quent to the mentioned amplier.
●The sensing operation stops during
optical communications.
OPTICAL COMMUNICATION
18
Communication direction
Sub ampliers
Main amplier
Code setting table
●Green digital display (right side is the rst digit)
Code
4th digit
Code
3rd digit
Code
2nd digit
Code
1st digit
Output operation mode Timer mode
Response
time setting
Light-receiv-
ing sensitivity
setting
Output 1 Output 2 Output 1 Output 2
Light-ON
Light-ON
No timer
No timer
80μs or less
(H-SP) Level 3
Dark-ON
O
FF-delay
timer
150μs or less
(FAST) Level 2
Light-ON
Dark-ON
ON-delay
timer
500μs or less
(STD) Level 1
Dark-ON One-shot
delay timer
4ms or less
(U-LG)
Level 4
(U-LG only)
- -
No timer
O
FF-delay
timer
- -
- -
ON-delay
timer
- -
- -
One-shot
delay timer
- -
- - - - - -
- - - - - -
●Red digital display (right side is the rst digit)
Code
4th digit
Code
3rd digit
Code
2nd digit
Code
1st digit
Communica-
tion enable /
disable setting
Hysteresis
setting
Backup
setting
CUSTOM
mode
Output mode
Output 1 Output 2
Communica-
tion enable
H-02 Backup
ON
Response
time setting
Normal
mode
Normal
mode
Communica-
tion disable
H-02 Backup
OFF
Light-receiving
sensitivity
setting
Window
comparator
mode
Communica-
tion enable
H-03
-
Emission
halt setting
Rising dier-
ential mode
Communica-
tion disable
H-03
-
Setting of data
bank loading
Trailing dier-
ential mode
Communica-
tion enable
H-01
-
Code setting
Hysteresis
mode
Communica-
tion disable
H-01
- -
Forced ON
output mode
- - - -
Forced OFF
output mode
- - - -
Normal
mode
Forced ON
output mode
- - - -
Forced OFF
output mode
Panasonic Industry Co., Ltd.
Panasonic Industrial Devices SUNX Co., Ltd.
https://panasonic.net/id/pidsx/global
Please visit our website for inquiries and about our sales network.
Panasonic Industrial Devices SUNX Co., Ltd. 2022
September, 2022 PRINTED IN JAPAN