Specification Data
Panasonic Ventilation Fan
Description
Ventilating fan shall be Low Noise ceiling mount type rated for continuous
run. Fan shall be ENERGY STAR rated and certified by the Home Ventilating
Institute (HVI). Evaluated by Underwriters Laboratories and conform to both
UL and cUL safety standards.
Motor/Blower:
•Totally enclosed DC brushless motor technology, currently more energy
efficient than the minimum ENERGY STAR requirements, rated for
continuous run.
•Power Rating shall be 120 volts and 60 Hz.
•Fan shall be UL listed for tub/shower enclosure when used with
a GFCI branch circuit wiring.
•Motor equipped with thermal cut-off fuse control.
•Removable with permanently lubricated plug–in motor.
Housing:
•Rust proof paint, galvanized steel body.
•Detachable 4" diameter duct adapter.
•Built-in backdraft damper.
•Expandable extension bracket up to 24".
•Double hanger bar system allowing for ideal positioning.
Grille:
•Attractive design using PP material.
•Attaches directly to housing with torsion springs.
Warranty:
•The factory warranty shall be a minimum of 6 years limited warranty on
the motor and 3 year limited warranty on parts.
Typical Specifications:
Ventilating fan shall be of the ceiling mount, ENERGY STAR rated type, with
variable speed of 0-80 CFM and no more than 0.3 sone as certified by the Home
Ventilating Institute (HVI) at 0.1 static pressure in inches water gauge. Power
consumption shall be no greater than 10.6 watts and ENERGY STAR rated with
efficiency rating of no less than 7.8 CFM/watt. The motor shall be totally enclosed
with brushless DC motor engineered to run continuously. Power rating shall be
120v/60Hz. Duct diameter shall be no less than 4”. Fan shall be UL and cUL
liste
Fan shall be California Title 24 compliant.
d for tub/shower enclosure when used with GFCI branch circuit wiring.
DC Motor Technology:
•Allows the fan to run continuously at a pre-set lower level (0 – 70 CFM).
The fan then elevates to a maximum level of operation (80 CFM) when
the switch is turned on.
•When fan faces static pressure, its speed is automatically increased to
ensure that the desired CFM is not compromised, which allows the fan to
perform as rated.
FV-08VKS2 (0-80 CFM)
Panasonic Home & Environment |One Panasonic Way |Secaucus, NJ 07094 |866-292-7292 |www.panasonic.com/building
For Complete Installation Instructions Visit www.panasonic.com/building
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
As of 4/09
®
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0 20 40 60 80 100
Static Pressure (inch w.g.)
FV-08VKS2
20 Feet
40 Feet
60 Feet
80 Feet
100 Feet
70 CFM
60 CFM
50 CFM
40 CFM
30 CFM
4"
14-1/2"
10-1/4" 10-1/4"
14-1/2" or
22-1/2"
7-7/8"
13"
13"
WhisperGreen
Static Pressure in inches w.g. 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25
Air Volume (CFM) 80 82 70 71 60 60 50 50 40 41 30 32
Noise (sones) <0.3 N/A <0.3 N/A <0.3 N/A <0.3 N/A <0.3 N/A <0.3 N/A
Power Consumption (watts) 10.6 16.2 8.6 14.0 7.0 11.8 6.1 10.2 5.6 9.2 4.7 8.2
Energy Efficiency (CFM/Watt) 7.8 5.0 8.7 5.1 9.1 5.1 9.0 4.9 8.4 4.4 7.9 3.9
Speed (RPM) 713 926 686 914 650 889 627 880 621 888 599 877
Current (amps) 0.07 0.11 0.06 0.10 0.05 0.08 0.04 0.07 0.04 0.06 0.03 0.06