Panasonic IO-Link SC-LG-CEF User manual

2023.1 panasonic.net/id/pidsx/global
IO-Link Configuration Tool
SC-LG-CEF
Conguration Tool
User’s Manual
WUME-SCLGCT-3

WUME-SCLGCT-32
(MEMO)

WUME-SCLGCT-3 3
Thank you for using SC-LG-CEF Conguration Tool.
SC-LG-CEF Conguration Tool is an application that can collect measurement data from Pan-
asonic IO-Link master SC-LG2-CEF-P and IO-Link devices connected to the IO-Link master,
set up various parameters, and load data.
Notes
1) No part of this manual may be reproduced or reprinted in any form or by any means without
prior written permission from Panasonic.
2) The contents of this manual are subject to change without notice for future improvement.
3) This manual has undergone strict quality control; but should you discover any dubious infor-
mation, mistakes, misplaced pages, or missing pages, please contact your local dealer.
4) CC-Link IE Field is a registered trademark of Mitsubishi Electric Corporation and a trademark
managed by CC-Link Partner Association.
5) GX Works3 is a registered trademark or trademark of Mitsubishi Electric Corporation.
6) Windows is a registered trademark or trademark of Microsoft Corporation in the United States
and/or other countries.
7) Ethernet is a registered trademark of FUJIFILM Business Innovation Corp..
8) IO-Link is a registered trademark of PROFIBUS User Organization.
9) The ownerships of all other trademarks belong to their respective owners.

WUME-SCLGCT-34
Manual Conguration
1 Before Using This Product
This chapter explains the terminology, the functions of this
software tool, the software license agreement for the soft-
ware tool.
2 Preparation This chapter explains the system environment, system
overview, and connections.
3 Name and Function of
Each Window
This chapter explains the name and function of each con-
guration window.
4 Other Functions
This chapter explains the master addition, removal, and as-
signment functions, project creation and saving functions,
network number setting function, and other functions.
5 Messages This chapter explains conrmation dialog boxes.

WUME-SCLGCT-3 5
Contents
Manual Conguration··········································································4
1 Before Using This Product ·····························································1-1
1.1 Handling Precautions·································································· 1-2
1.2 Terminology ·············································································· 1-2
1.3 Overview·················································································· 1-3
1.4 Software License Agreement ························································ 1-4
2 Preparation·················································································2-1
2.1 System Environment··································································· 2-2
2.2 System Overview ······································································· 2-3
2.2.1 System Connection Diagram·····················································2-3
2.3 Setup on the Programmable Controller (GX Works3) Side ·················· 2-4
3 Name and Function of Each Window················································3-1
3.1 Operating Procedure ·································································· 3-2
3.2 Login Window ··········································································· 3-3
3.3 Start Window············································································· 3-4
3.4 Master Port Conguration Window················································· 3-5
3.4.1 Master Port Conguration·························································3-5
3.4.2 Select Device Window ·····························································3-8
3.5 Master Information Window························································ 3-10
3.6 Device Monitoring Window························································· 3-11
3.7 Device Setup Window ······························································· 3-12
3.8 Device Diagnosis Window·························································· 3-13
3.9 Device Information Window························································ 3-14
3.10 Option Window ······································································ 3-15
3.11 Version Information Window······················································ 3-16
4 Other Functions ···········································································4-1
4.1 Master Addition Function ····························································· 4-2
4.2 Master Removal Function ···························································· 4-3
4.3 Master Assignment Function ························································ 4-3
4.4 Device Settings Copy / Paste Function ··········································· 4-4
4.5 Project Creation Function ···························································· 4-4
4.6 Project Saving Function······························································· 4-5
4.7 IODD Management Function ························································ 4-5
4.8 Network Number Setting Function ················································· 4-6
4.9 Language Switching Function ······················································· 4-7
4.10 Exit Function ··········································································· 4-7
5 Messages···················································································5-1
5.1 Messages················································································· 5-2

WUME-SCLGCT-36
(MEMO)

1-1
1 Before Using This Product
1.1 Handling Precautions·································································· 1-2
1.2 Terminology ·············································································· 1-2
1.3 Overview·················································································· 1-3
1.4 Software License Agreement ························································ 1-4

1.1 Handling Precautions
WUME-SCLGCT-31-2
1.1 Handling Precautions
■The following symbols are used to indicate safety information that must be observed.
Indicates an action that is prohibited.
Indicates an action that must be taken.
Indicates a matter that requires caution.
Information
Indicates supplemental information.
Reference Indicates reference to details about the subject in question.
Caution
Indicates points to be noted when the product is operated.
1.2 Terminology
Term Description
CC-Link IE
Field related
Master station A station that controls the entire network. This station can perform cyclic
transmission and transient transmission to all stations.
Slave station
A generic name of all stations other than master stations (local stations,
remote I/O stations, remote device stations, and intelligent device sta-
tions)
SC-LG2-CEF-P
An IO-Link master compliant with CC-Link IE Field.
This master connects IO-Link devices using e-CON connectors.
PNP connection is based on the I/O interface specications of IO-Link
devices.
CC-Link IE Field net-
work
A high-speed and large-capacity open field network using Ethernet
(1000BASE-T)
Cyclic transmission
A function that periodically exchanges data between stations on the
same network in the data link layer
Transient transmission
A function that uses the read/write instructions of the program at the lo-
cal station to read and write data from / to remote stations and commu-
nicate with remote stations via peripheral devices in the data link layer
Memory map
A memory map where the functions of the communication unit are al-
located to link devices. The master station can use the functions of
the communication unit by accessing the link devices allocated on the
memory map.
Link device Internal devices held by the unit (RX, RY, RWr, and RWw)
Network number
A unique number that is assigned to identify each network when mul-
tiple networks are created.
Duplicate numbers cannot be set among all networks.
Station number
A unique number that is assigned to identify each network unit that is
connected to a network.
Duplicate numbers cannot be set among all network units within a net-
work.
Intelligent device sta-
tion
A station that cyclically transmits bit-based I/O signals and word-based
I/O data to the master station. This station returns responses to tran-
sient transmission requests from other stations.

1.3 Overview
WUME-SCLGCT-3 1-3
Term Description
IO-Link re-
lated
Process data (PD)
Cycle data. Process data is automatically transmitted during normal op-
eration.
IEC 61131-9
One of the international certications handling PLC standards that spec-
ies an I/O connection technology standardized for communication with
sensors or actuators
IODD Describes the device's own information and settings
IO-Link A digital communications protocol that connects sensors or actuators to
remote I/O, PLC, etc.
IO-Link device Performs one-to-one and point-to-point IO-Link communications with
the IO-Link master
IO-Link master Plays a role as a gateway to transfer data between each IO-Link device
and each of the systems connected to high-level buses
Port An IO-Link communication channel port
1.3 Overview
SC-LG-CEF Conguration Tool has the following functions.
●IO-Link master detection function
This function detects IO-Link master SC-LG2-CEF-P on the CC-Link IE Field network via a
programmable controller (PLC).
● IO-Link master port conguration function
This function congure a port for IO-Link master SC-LG2-CEF-P that is detected.
●Function for communicating with IO-Link devices via IO-Link master
The following processing can be performed on IO-Link devices connected to IO-Link master
SC-LG2-CEF-P that is detected.
• Reading process data from IO-Link devices and setting some data
• Monitoring the IO-Link device detection status
• Checking diagnosis information for IO-Link devices
●Other functions
Project saving function, language switching function, and other functions

1.4 Software License Agreement
WUME-SCLGCT-31-4
1.4 Software License Agreement
Panasonic Industrial Devices SUNX Co., Ltd. (“PIDSX”) grants to you a license to use this Soft-
ware on condition that you accept this Agreement. You must read this Software License Agree-
ment (this “Agreement”) carefully before using this Software. Only in case that you accept this
Agreement, you may start your use of this Software.
Your unsealing the package of this Software, or your downloading, installing or launching this
Software or the like shall be deemed as your acceptance of this Agreement.
The Software includes not only proprietary computer programs owned by or licensed by PIDSX
but also open source software programs. As for the open source software programs, refer to the
detailed terms and conditions thereof shown in the installation package of the Software. Should
a discrepancy arise between any of the terms of this Agreement and any open source software
program license statement, the open source software program license statement shall take pre-
cedence over this Agreement.
Article 1 Grant of License
PIDSX hereby grants to you a non-exclusive license to use this Software only in com-
bination with PIDSX product(s) specied in the manual of this Software (the “Product”)
in accordance with the terms of this Agreement. You may not use this Software in con-
nection with products of any third party other than PIDSX.
Article 2 Restrictions
You may NOT:
(1) Modify, reverse engineer, decompile, or disassemble this Software,
(2) Use this Software by methods or for purposes other than those specied in the
manual of this Software provided by PIDSX, nor
(3) Distribute, rent, lease or otherwise transfer this Software to any third party; pro-
vided, however, that you may assign the rights to use this Software under this
Agreement along with the Product on the condition that the assignee agrees to
be bound by all the terms of this Agreement. In the case of such assignment, you
must deliver any and all the copies of this Software and all the accompanying ma-
terials to the assignee and you may not retain any copies of this Software includ-
ing backups.
Article 3 Disclaimer
3-1.
PIDSX MAKES NO WARRANTY OR REPRESENTATION OF ANY KIND, EXPRESS,
IMPLIED OR STATUTORY, WITH RESPECT TO THIS SOFTWARE, INCLUDING BUT
NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR
PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD PARTY RIGHTS.
3-2. UNDER NO CIRCUMSTANCES SHALL PIDSX BE LIABLE FOR ANY DAMAGES
(INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR SPECIAL
DAMAGES WHATSOEVER) ARISING OUT OF THE USE OF THIS SOFTWARE, IN-
ABILITY TO USE THIS SOFTWARE, DEFECTS IN THIS SOFTWARE (e.g., BUGS,
SECURITY HOLES, AND MALFUNCTION), OR OTHERWISE IN CONNECTION
WITH THIS SOFTWARE.
Article 4 Term
4-1. This Agreement shall come into eect upon your unsealing the package of this Soft-
ware, or your downloading, installing or launching this Software or the like.
4-2. PIDSX may terminate this Agreement immediately, if you breach any of the provisions
of this Agreement.
4-3. You shall, at your own costs, return, delete or destroy this Software and any of its cop-
ies within four (4) weeks after termination of this Agreement.

1.4 Software License Agreement
WUME-SCLGCT-3 1-5
Article 5 Export Control
You shall comply with all laws and regulations regarding export control under any
competent jurisdiction, including but not limited to the Japanese Foreign Exchange
& Foreign Trade Control Law, the export control regulations based on resolutions of
the United Nations Security Council, etc. If any license or appropriate approval from a
governmental authority is required under the applicable laws, you may not export this
Software without such approval to any countries either directly or indirectly. Further-
more, you shall neither use nor sell this Software for military purposes either directly or
indirectly.
Article 6 Intellectual Property Rights
Except the open source software program, all intellectual property rights in this Soft-
ware, including the copyright, belong to PIDSX and/or the licensors of PIDSX.
Article 7 Upgrade of this Software
7-1. Release of future upgrades or updates of this Software is not guaranteed and left to
the sole discretion of PIDSX. Furthermore, PIDSX may charge fees for upgrading or
updating of this Software.
7-2. If any upgrades or updates are provided to you either for fees or for free, such up-
grades or updates shall be deemed as a part of this Software and shall be governed
by this Agreement, unless PIDSX designates otherwise at the time of provision of such
upgrades or updates.
Article 8 Limitation on Liability
AGGREGATE LIABILITIES OF PIDSX IN CONNECTION WITH THIS AGREEMENT
OR THIS SOFTWARE SHALL IN NO EVENT EXCEED TEN THOUSAND (10,000)
YEN.
Article 9 Governing Law and Jurisdiction
9-1. This Agreement shall be governed by the laws of Japan.
9-2. Should any dispute arise from or in connection with this Agreement, Nagoya District
Court, Japan shall exclusively have jurisdiction over such dispute.
This Software consists of the following types of software.
(1) Software developed independently by PIDSX
(2) Software owned by a third party and licensed to PIDSX
(3) Open source software licensed on conditions of such open source software
PIDSX makes no warranty, including implied warranties of merchantability and/or tness for par-
ticular purpose to software in category (3) above. For details, Please refer to the detailed terms
and conditions thereof shown in the installation package of this Software.

WUME-SCLGCT-31-6
(MEMO)

2-1
2 Preparation
2.1 System Environment··································································· 2-2
2.2 System Overview ······································································· 2-3
2.2.1 System Connection Diagram·····················································2-3
2.3 Setup on the Programmable Controller (GX Works3) Side ·················· 2-4

2.1 System Environment
WUME-SCLGCT-32-2
2.1 System Environment
SC-LG-CEF Conguration Tool operates in the following system environment.
●Compatible operating systems:
Microsoft®Windows®10 Pro 32bit, 64bit
●Processor: Atom 1.33GHz or faster processor
●Memory: 2GB minimum
●Display: 1,024 × 768 or higher resolution with at least 256 colors
●Interface: 1Gbps
●Hard disk: Maximum 500MB free space required
●CD or DVD drive: Not required
●.NET Framework 4.6.2 onwards
Download and install .NET Framework from Microsoft®download center if it is not already installed.
●Microsoft Visual C++ 2017 SP1
Redistributable Package (x86) must be installed separately.
●Adobe Reader
To display the Manual from the Help menu, Adobe Reader must be installed separately.
●Programmable controller (PLC) and CC-Link IE Field master unit
●GXWorks3
GXWorks3 must be installed separately because SC-LG-CEF Configuration Tool controls
SC-LG2-CEF via sequencer manufactured by Mitsubishi Electric Corporation.
Reference
For information about compatible PLCs and CC-Link IE Field master units, refer to the website of
CC-Link Partner Association (https://www.cc-link.org/en/).
The following models have been tested and conrmed to connect properly as of December 2021.
• QJ71GF11-T2
• LJ71GF11-T2
• RJ71EN71
• RJ71GF11-T2

2.2 System Overview
WUME-SCLGCT-3 2-3
2.2 System Overview
This system enables SC-LG-CEF Conguration Tool to transfer measured values and other
data from IO-Link devices (such as sensors) via a programmable controller (PLC) and CC-Link
IE Field network.
The main functions of the system are the IO-Link master setup function and the IO-Link device
data monitoring / setting function.
2.2.1 System Connection Diagram
This system is explained as below.
IO-Linkデバイス
IO-Linkマスタ
CCIEF
Master
CPU
PC
PLC
The PC and PLC are connected with an Ethernet or USB cable.
The SC-LG2-CEF-P is used as IO-Link masters.
IO-Link devices including other manufacturers' products are used as IO-Link devices. The IODD
file associated with each IO-Link device must be imported into SC-LG-CEF Configuration
Tool.
Caution
● Download the IODD les from the website of the IO-Link device manufacturer or the
IODDnder website (https://ioddnder.io-link.com/).
● The IODD les of Panasonic IO-Link devices can be downloaded from our website
(https://panasonic.net/id/pidsx/global).
IO-Link masters
IO-Link devices

2.3 Setup on the Programmable Controller (GX Works3) Side
WUME-SCLGCT-32-4
2.3 Setup on the Programmable Controller (GX Works3) Side
This section explains how to set up parameters for IO-Link master SC-LG2-CEF-P.
The parameter setting method diers according to the master station unit.
The parameter setting method is explained below, using Mitsubishi Electric Corporation's
RJ71EN71 as an example.
Reference
For details, refer to the instruction manual of the master station unit that you use.
● Example of RJ71EN71(CCIEF) unit parameter settings
Station type: Master station
Network No.: 1
<Network conguration settings>
Station number: 1
RX / RY settings (starting / ending): 1000 / 106F
RWw / RWr settings (starting / ending): 1000 / 1083
<Refresh settings>
Link side CPU side
Device
name
Starting
address
Ending
address
Device
name
Starting
address
SB 00000 001FF SB 00000
SW 00000 001FF SW 00000
RX 01000 0106F X 01000
RY 01000 0106F Y 01000
RWr 01000 01083 W 01400
RWw 01000 01083 W 00400

2.3 Setup on the Programmable Controller (GX Works3) Side
WUME-SCLGCT-3 2-5
●Setting up RJ71EN71(CCIEF) unit parameters
Set up parameters in the engineering software (GX Works3) at the master station.
1. In the Navigation window, select Module Information and then RJ71EN71(CCIEF).
Reference
For details on how to set up the master station, refer to the instruction manual of the master station
unit that you use.
2. Set up the contents of Required Settings for module parameters as shown below.

2.3 Setup on the Programmable Controller (GX Works3) Side
WUME-SCLGCT-32-6
3. Double-click <Detailed Setting> in Network Conguration Settings.
4. The CC IE Field Conguration dialog box will be displayed.
In the Module List, select SC-LG2-CEF-P under CC IE Field Module (Panasonic Indus-
trial Device SUNX) and drag and drop it into the station list or network conguration diagram.
SC-LG2-CEF-P will be added.
Station list
Network
conguration
diagram Drag and drop
If CSP+ for SC-LG2-CEF-P has not been registered, "SC-LG2-CEF-P" will not be displayed
in the Module List. Register CSP+ in advance.
If CSP+ for SC-LG2-CEF-P cannot be registered, use and set CSP+ for general intelligent
device stations.
Reference
For information about how to download CSP+, refer to the SC-LG2-CEF-P User's Manual (our web-
site: https://panasonic.net/id/pidsx/global).

2.3 Setup on the Programmable Controller (GX Works3) Side
WUME-SCLGCT-3 2-7
5. Set up a CC IE Field conguration as shown below.
6. After setting up the conguration, click the Close with Reecting the Setting menu to close
the CC IE Field Conguration dialog box.

2.3 Setup on the Programmable Controller (GX Works3) Side
WUME-SCLGCT-32-8
7. Double-click <Detailed Setting> in Refresh Settings.
8. A refresh parameter setting window will be displayed. Specify settings as below.
Table of contents
Other Panasonic Tools manuals

Panasonic
Panasonic EY7460LN2S User manual

Panasonic
Panasonic EY75A4 User manual

Panasonic
Panasonic 4414 User manual

Panasonic
Panasonic EY7460 - DRILL DRIVER 21.6V User manual

Panasonic
Panasonic EY3641 User manual

Panasonic
Panasonic EY3551 - 18V WOOD SAW User manual

Panasonic
Panasonic EY3654 - 7.2V CAULKING GUN User manual

















